HomeMy WebLinkAboutDRB140257_DRB140257 Data Sheets_1404248520.pdfTable 3. Roof Field Area (Zone 1) Uplift Design Pressure, p, for Exposure B, Flat or Gable Roof,Θ≤7° (For 60 ft (18 m)<h<90ft(27m),limited to h/w ≤1); Enclosed Building p = 0.00256 Kz Kzt Kd V2 I [(GCp)–(GCpi)] in pounds per ft 2 (psf) Enclosed Building; Roof Zone 1 (Field Area), Effective Wind Area 1 to 10 ft 2; Kzt =1.0;z=h;(GCp)=-1.0forh<90ftand(GCp) = - 1.4 for h ≥90 ft; (GCpi) = 0.18 Mean Roof Height h (ft) Basic Wind Speed, V, 3-sec gust, (mph) ≤85 90 100 110 120 130 140 145 150 160 170 185 Roof Field Area Uplift Design Pressure, p, Exposure B (psf) 0-15 15 17 21 25 30 35 41 43 47 53 60 71 30 15 17 21 25 30 35 41 43 47 53 60 71 60 18 20 25 31 36 43 49 53 57 65 73 86 89 20 23 28 34 41 48 55 60 64 72 82 97 90 27 31 38 46 55 64 74 80 86 97 110 130 100 28 32 39 47 56 66 77 82 88 100 113 134 200 34 39 48 58 69 80 93 100 107 122 138 163 300 39 43 53 65 77 91 105 112 121 137 155 183 400 42 47 58 70 84 98 114 122 131 149 168 199 500 45 50 62 75 89 105 121 130 139 158 179 212 p = 0.000613 Kz Kzt Kd V2 I [(GCp)–(GCpi)] in kilopascals (kPa) Enclosed Building; Roof Zone 1 (Field Area), Effective Wind Area 0.1 to 0.9 m 2; Kzt =1.0;z=h;(GCp)=-1.0forh<27mand(GCp) = - 1.4 for h ≥27 m; (GCpi) = 0.18 Mean Roof Height h (m) Basic Wind Speed, V, 3-sec gust, (m/s) ≤38 40 45 50 55 60 65 70 75 80 85 Roof Field Area Uplift Design Pressure, p, Exposure B (kPa) 0-5 0.7 0.8 1.0 1.2 1.5 1.8 2.1 2.4 2.8 3.2 3.6 10 0.7 0.8 1.0 1.3 1.5 1.8 2.2 2.5 2.9 3.3 3.7 18 0.9 1.0 1.2 1.5 1.8 2.2 2.5 2.9 3.4 3.8 4.3 20 0.9 1.0 1.3 1.6 1.9 2.2 2.6 3.0 3.5 4.0 4.5 27 1.0 1.1 1.4 1.7 2.0 2.4 2.9 3.3 3.8 4.3 4.9 27.4 1.3 1.5 1.8 2.3 2.7 3.3 3.8 4.4 5.1 5.8 6.5 30 1.3 1.5 1.9 2.3 2.8 3.4 3.9 4.6 5.2 6.0 6.7 60 1.6 1.8 2.3 2.8 3.4 4.1 4.8 5.6 6.4 7.3 8.2 90 1.8 2.0 2.6 3.2 3.9 4.6 5.4 6.3 7.2 8.2 9.2 120 2.0 2.2 2.8 3.5 4.2 5.0 5.9 6.8 7.8 8.9 10.0 150 2.1 2.4 3.0 3.7 4.5 5.3 6.2 7.2 8.3 9.4 10.7 Notes: 1. Interpolation is appropriate. 2. Pressure (p), is total net pressure (external and internal). Wind Design 1-28 FM Global Property Loss Prevention Data Sheets Page 7 ©2007 Factory Mutual Insurance Company. All rights reserved. Table 6. Roof Design Outward Pressure Multipliers for Roof Zones 1, 2, and 3 Roof Design Negative Pressure Multipliers Zones 1, 2, 3 for Flat and Gabled Roofs Apply multipliers to pressure values in Tables 3, 4, and 5, as appropriate. Mean Roof Height, h Roof Slope Enclosed Building Partially Enclosed Building 6 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 h ≤60 ft (18 m); and when h/w ≤1for60<h<90ft(18 <h<27.4 m) Θ≤7°1.0 1.68 2.53 1.31 1.99 2.85 7°<Θ≤27°0.92 1.59 2.36 1.23 1.91 2.67 27°<Θ≤45°1.0 1.17 1.17 1.31 1.48 1.48 when h/w>1for60ft<h< 90ft(18<h<27.4 m) See Note 6 below Θ≤10°1.34 2.10 2.86 1.65 2.42 3.18 10°<Θ≤27°0.92 1.59 2.36 1.23 1.91 2.67 27°<Θ≤45°1.0 1.17 1.17 1.31 1.48 1.48 h ≥90 ft (27.4 m) See Note 6 below Θ≤10°1.0 1.57 2.14 1.23 1.80 2.37 10°<Θ≤27°0.68 1.19 1.76 0.92 1.42 1.99 27°<Θ≤45°0.75 0.87 0.87 0.98 1.11 1.11 Zone Notes: 1. Zone 1 except Zone 2 if Θ >7°. 2. Zone 2 except Zone 3 if Θ≤7°andh>60ft(18m). 3. Zone 2 except Zone 3 if Θ >7°and h ≤60 ft (18 m). 4. If a parapet height ≥3 ft (1 m) is provided around the perimeter of the roof with Θ≤7°, treat Zone 3 as Zone 2. 5. 7°=11⁄2 in./12 in. (125 mm/m); 10° = 2 in./12 in. (167 mm/m); 27° = 6 in./12 in. (500 mm/m); 45° = 12 in./12 in. (1 m/m). 6. Partially enclosed building multipliers for roofs are based only on openings affecting the top story. 7. Value of ‘‘a’’: a) For h ≤60 ft (18 m), ‘‘a’’ is the smaller of 0.1 times the building lesser plan dimension or 0.4 times h, and never less than 4% of the least horizontal dimension, or 3 ft (0.9 m). Zone 3 is a square with dimensions ‘‘a’’. b) Forh>60ft(18m),‘‘a’’is0.1times the building lesser plan dimension, but not less than 3 ft (0.9 m). Zone 3 is an ell with dimensions ‘‘2a’’. 8. Value of ‘‘h’’: a) For slopes ≤7°, h = eave height b) For slopes > 7°, h = mean roof height 9. Value of ‘‘w’’ is based on the lesser plan dimension. 1-28 Wind Design Page 10 FM Global Property Loss Prevention Data Sheets ©2007 Factory Mutual Insurance Company. All rights reserved. 2.2.7 Minimum Wind Rating for FM Approved Roof System Based on the field of roof area design pressure previously obtained, use Table 8 to determine the minimum FM Approved wind classification rating needed for the entire roof assembly (deck and above-deck system). Table 8. Recommended Rating of Field, Perimeter, and Corner areas for Enclosed Building 2 (Zones 1, 2, and 3) Roof Field Area Design Pressure, p, (psf) 2 Minimum Wind Rating for FM Approved Deck/Above-Deck/Entire 1 Assembly Roof Field Area Roof Perimeter Area Roof Corner Area 15<p≤20 60 75 105 20<p≤25 60 90 120 25<p≤30 60 105 150 30<p≤37.5 75 120 180 37.5 < p ≤45 90 150 225 45<p≤52.5 105 180 270 52.5 < p ≤60 120 195 300 60<p≤67.5 135 225 330 67.5 < p ≤75 150 255 360 75<p≤82.5 165 270 405 82.5 < p ≤90 180 300 435 90<p≤97.5 195 315 480 97.5 < p ≤105 210 345 510 105<p≤112.5 225 360 540 112.5 < p ≤120 240 390 585 120<p≤127.5 255 420 615 127.5 < p ≤135 270 435 660 1 If a minimum 3 ft (0.9 m) high parapet is provided, which is adequately designed for horizontal wind load, treat the corner as a perimeter area. 2 For roofs with higher field area design pressures, or to interpolate needed perimeter and corner ratings when the field requirements are between levels, multiply the needed field area design pressure from Table 3, 4 or 5 (of D.S. 1-28) by a safety factor of 2.0 and the respective pressure coefficient for perimeter and corner areas (see Table 6), and round up to the next highest 15 psf rating interval. 3 Ratings above apply to enclosed buildings, with roof slopes ≤7˚and roof heights ≤60 ft (18 m). For other situations, see the respective tables in this document. 2.3 Wall, Door, and Window Design Design wall panels, doors, windows and their securement to guidelines in this section. Where the effective wind area of a door or window considerably exceeds 10 ft 2 (1 m 2), or 20 ft 2 (2 m 2), for walls over 60 ft or 18 m high, pressures may be reduced in accordance with ASCE 7 to reflect the larger area only. Use impact-resistant glazing or glazing protection, and impact-resistant dock doors rated for small or large missile exposure (as applicable) when located within a windborne debris region (seeAppendixA). Ensure they are satisfactorily tested per Florida Building Code Testing Application Standards (TAS) 201, 202, and 203, or ASTM Standards E1886 and E1996. Some manufacturers of window films are FM Approved (see the Approval Guide Building Materials Volume, Windstorm Resistant Fenestration) for small missile resistance for application on the interior surface of existing windows.Regardless of what design level from Table 1 is chosen, use the basic wind speed map and Appendix A to determine the need for fenestration protection. Determine basic wind speed and Surface Roughness Exposure in accordance with Sections 2.2.1 and 2.2.2 of this data sheet. When significant hills, ridges, or escarpments are present, refer to Section 2.2.4. For wind tunnel testing, refer to Section 2.2.5. The following provides an overview of the methodology to determine inward and outward wall design pressures. 2.3.1 Outward Wall Pressure for Enclosed Building •Determine outward pressure for wall Zone 4 and Θ≤10˚using Tables 9, 10, or 11. •Determine outward pressure for wall Zones 4 and 5 various Θ by applying multipliers in Table 12. Wind Design 1-28 FM Global Property Loss Prevention Data Sheets Page 13 ©2007 Factory Mutual Insurance Company. All rights reserved. WINDLOADCALC.com90 Job NumberB Client's Name Internal Pressure Enclosed Company Height above ground (z) -(ft) Address Standard Wall Height - (ft) 30.0 Preparer Mean Roof Height (h) - (ft) 32.0 Building Width (ft) 58.0 Building Length (ft) 185.0 Roof Slope (x:12) 3.0Flat - No Hill Roof Angle (degrees) 14.040.0 (a) Edge Strip (ft) 5.800.011.600.00.000.0Gable 1-Gable N/A 46.0 173.0 9976 6.0 -12.3Gable 2-Gable N/A 6.0 173.0 9976 6.0 -17.4Gable 3-Gable N/A 6.0 6.0 36 7.2 -30.8 Exposure Version 7MAXIMUM POSITIVE PRESSURE (psf) [Windward]ROOF INFORMATION Parapet Along Roof Perimeter (ft)APPLYING WIND LOAD FOR: ZONE Hill Shape H, (ft) Lh, (ft) x, (ft)BUILDING INFORMATION Wind Velocity (mph)Wind Load Program z, (ft)ManufacturerWIDTH (feet)OPENING ELEVATION (feet)LENGTH (feet)NOA Approval Number JOB INFORMATIONASCE 7-10RoofTech Consultants, Inc.Model NumberWIND LOAD DESIGN INFORMATIONMax Pressure Per NOA End Zone (ft)EFFECTIVE WIND AREA (sqft)MAXIMUM NEGATIVE PRESSURE (psf) [Leeward]INFO.TOPOGRAPHIC FACTOR2004 - 2011 ©Building Permit EditionVail Racquet Club - Bldgs 1 & 2Vail Racquet Club - Bldgs 1 & 214828 W 6th Avenue, Golden, CO 80401R ScottASCE 7-10www.windloadcalc.com5/23/2014 Page1 Windloadcalc.com90EFFECTIVEBROOF TYPE ZONE WIND AREAEnclosed(sqft)0Gable 1-Gable 46.0 173.0 9976 6.04 -12.330000 Standard Wall Height - (ft) 30Gable 2-Gable 6.0 173.0 9976 6.04 -17.360000 Mean Roof Height (h) - (ft) 32Gable3-Gable6.06.0367.15-30.77000058185314.045.811.60.0019.23 -60.45 End Zone (ft) (a) Edge Strip (ft) Parapet Along Roof Perimeter (ft) Building Width (ft) Wind Velocity (mph) Roof Slope (x:12)Total Roof Pressure Roof Angle (degrees) Exposure Building Length (ft)BUILDING INFORMATION Internal Pressure Height above ground (z) -(ft)GABLE ROOF INFORMATIONWIDTH (ft) LENGTH (ft)GABLE PRESSURES NOA INFORMATIONNOA Approval Number Max Pressure Per NOAMAXIMUM POSITIVE PRESSURE (psf) [Windward]MAXIMUM NEGATIVE PRESSURE (psf) [Leeward]Manufacturer Model Number HEATING SAVINGS ITEM DESCRIPTION R-25 OPTION _______________________________ DESIGN TEMPERATURE (F) -10 DEGREE DAYS 9,947 EQUIV. TEMP. DIFF. COOLING ENERGY (KWH/TON) COOLING HOURS SYSTEM EFFICIENCY (%) 80 ROOF AREA (SF) 7,117 NATURAL GAS COST ($/CCF) $0.90 ELECTRICAL COST ($/KWH) 0.07 FUEL INFLATION RATE (%) 5 INSUL. COST ($) $32,500.00 R-VALUE STRUCTURE & FILMS 4 ________________________________ BASE OVERALL R-VALUE 4 R-VALUE INSULATION 25 ________________________________ OVERALL R-VALUE 29 R-VALUE DIFFERENCE 25 C-VALUE DIFFERENCE 0.22 FUEL SAVINGS (THERMS) 5231 FUEL SAVINGS (CCF) 5231 FUELS SAVINGS (KWH) FUEL SAVINGS ($) $4,707.90 APPROX. PAYBACK (YRS)5 EST. 20 YR. SAVINGS $269,644.71 SAVINGS AFTER INVEST. $237,144.71 REPLACE ROOF - BUILDING 1 & 2 VAIL RACQUET CLUB THERMAL INSULATION PAYBACK R-25 THERMAL VALUE - NEW INSULATION