Loading...
HomeMy WebLinkAboutDRB140266_SKMBT_C25314070810460_1404923100.pdf ,oc Engineering Solutions Since 12-9.519C) CATOR RUMA Mechanical n Electrical O Plumbing 0 Technology 0 Architectural Lighting 0 Commissioning d 1,5•SOCIA1FS CO March 10,2014 PRINCIPALS Michael A.Meints James R.Lazzeri Bruce E.Appel Mr. Brandt Marott Sean T.Convery Kevin B.Miller Director of Engineering Dennis F.Rudko Vail Resorts Wayne A.Trader 675 Lionshead Place MarcusA.Valerius Vail, CO 81657 SR.ASSOCIATES Re: The Arrabelle at Vail Square Mark V.Jelinske Condominium Balcony Gas Piping- Units 343 and 372 Gerard W.O'Brien CRA#2011-297 ASSOCIATES Kelvin K.Doss Dear Brandt: Jeffrey L.Jesse Gregg I.McMullen This letter addresses the design and installation of natural gas piping serving the balconies Bruce D.Osborn of Units 343 and 372 at the Arrabelle at Vail Square. Geri Ann Rosier Jacqueline H.Rudko In Unit 343, it is acceptable to connect a new 3/4" pipe to the existing 2" natural gas riser Robert A.Weber serving the fireplace in this unit and the units above, and route to an accessible gas cock at Blake L.Winter the balcony. The size of the gas pipe serving the balcony is based on a 30,000 BTU/h barbecue. In Unit 372, it is acceptable to connect a 3/4" pipe to the existing 1-1/4" natural gas riser, and route to an accessible gas cock at the balcony. As with Unit 343,the size of the gas pipe serving the balcony is based on a 30,000 BTU/h barbecue. The installation standards should generally conform to the base building specifications and code requirements,and shall provide for the safety of the building occupants. The natural gas system should be thoroughly inspected and tested prior to putting anything back in service. Installation and replacement of gas piping and accessories shall be performed only by a qualified installer. The term qualified is defined as experienced in such work,familiar with precautions required,and has complied with the requirements of the authority having jurisdiction. The installing Contractor shall comply with the requirements of the following codes: o NFPA 54-National Fuel Gas Code,for gas piping materials and components,gas piping installations, and inspection,testing,and purging of gas piping systems. o Town of Vail Local Building Code. o Utility Compliance: Fabricate and install natural gas systems in accordance with local gas utility company. 896 Tabor Street 0 Lakewood,Colorado 80401-4700 0 303.232.6200 420 W.Lincolnway o Cheyenne,Wyoming 82001 0 307.274.3830 www.catorruma.com Mr.Brandt Marott March 10,2014 Engineering Solutions Since 1959 Please note,at the Owner's request, Cator, Ruma and Associates, Co.did not perform a site observation of the existing gas piping installation, and therefore certain assumptions were made in the development of this letter, based on specific input from Vail Resorts. Cator, Ruma is not responsible for code compliance or installation of the proposed work outlined herein. If you have any questions, please do not hesitate to call or email. Sincerely, CATOR,RUMA&ASSOCIATES, CO. David Yeingst, P.E. Sr. Mechanical Engineer DLY/ef P:\Arrabelle\2014033 Gas Piping Revisions\Sup\Docs\2014-033ltr(DLY).o307.14.docx Attachments: cc: File-CATOR,RUMA&ASSOCIATES By Electronic Mail Page 2