HomeMy WebLinkAboutDRB140275_2722 Cortina Lane - Sheet - A1-0 - COVER SHEET_1408029120.pdfScale
Date
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
4
1
A5.1
A
3.2
PROJECT DIRECTORY
1
2
3
4
A9.1
A6.1
1
A6.1
1
100
LIVING
1
A4.1
SIM.
SYMBOL LEGEND
ABBREVIATIONS
MATERIAL LEGEND
DRAWING LIST:
VICINITY MAP
ARCHITECT
100
A
BUILDING
SECTION NO.
SECTION CUT
SHEET NO.
DETAIL NO.
DETAIL CUT
SHEET NO.
ROOM NUMBER
EXTERIOR ELEVATION
DOOR MARK
DETAIL CUT
REFERENCE GRID LINE
SPOT ELEVATION
DRAWING REVISION
INTERIOR ELEVATION
WINDOW MARK
Galvanized
Laminated Wood Beam
General Contractor
Hardware
Gypsum Wallboard
Grade
Gypsum
RW
RO
SEW
SECT
SAN
SHLV
Cpt Carpet
Ceramic
CER
SIM
SHT
W/
Reinforce (d)
REINF
FD Floor Drain
With (comb. form)
Required
Round Head Sheet Metal Screw
GA
FDN
FTG
Room
RM
RHSM
REQD
Gauge
Foundation
Footing
WD
W/O
Wood
Without
and Air Conditioning
Heating, Ventilating,
Lavatory
Manufacturer
Laminate
Inside Diameter
Miscellaneous
Mechanical
Not In Contract
Medicine Cabinet
Masonry Opening
Horizontal
On Center
Not to Scale
Oriented Strand Board
Opposite
Outside Diameter
Property
Plywood
Perforated (d)
Prefinished Sheet Metal
Penny (nails, etc.)
Refrigerator
Radius or Riser
Not Applicable
AAD
ADD
AGG
ADJ
AOR
BM
ARCH
ALT
BD
BS
BET
BRG
AFF
CL
BLDG
CAB
CLOS
CMU
CJ
CONC
COL
DP
DIA
DET
CONT
BO
DR
DN
DW
EL
EA
DRWG
DS
EQ
EJ
EXIST
EXT
FE CABT
FOC
FOS
FP
FL
FIN
DIM
GC
GALV
Glass
GLB
GR
GL
Head
HD
HDW
GWB
Highway
Height
HWY
HT
HVAC
GYP
Addendum
Attic Access Door
Aggregate
Adjacent
Area of Refuge
Alternate
Beam
Architectural
Board
Between
Both Sides
Bearing
Above Finished Floor
Interior
Joint
JT
INT
ID
MO
MFG
LAV
LAM
Maximum
Material
MAX
MC
MTL
Minimum
NIC
MISC
MIN
MECH
Cabinet
Building
Centerline
Closet
Concrete
Column
Construction Joint
Detail
Diameter
Damproofing
Continuous
Concrete Masonry Unit
HOR
Bottom Of
Opening
OPG
OC
NTS
d
OD
OSB
OPP
Plate
PL
PFSM
PLWD
PERF
Project
Product
PROD
PROP
PROJ
Drain
Dishwasher
Down
Elevation
Each
Drawing
Downspout
Equal
Existing
Exterior
Expansion Joint
Face Of Concrete
Face Of Stud
Fire Extinguisher Cabinet
Refer
REF
REFR
Floor
Fireproof R
Finish
NA
Dimension
Tounge and Groove
Toilet Paper Holder
Sound- Transmission Class
Vinyl Asbestos Tile
United States Gage
Unless Noted Otherwise
Uniform Building Code
SL
SQ
SPEC
STC
SM
SUB
STRUCT
STL
TV
TEL
SUSP
SUPPL
IE
THK
TEMP
TO
T&B
T&G
TPH
STD
Roof Window
Sewer
Sanitary
Section
Rough Opening
Sliding
Shelves
Similar
Square
Specification
Sheet Metal
Sheet
Steel
Substitute
Structure (al)
Television
Telephone
Suspend (ed)
Supplement (al)
That Is
Thick
Tempered
Top Of
Top and Bottom
Standard
UG
TYP
TS
USG
UBC
UNFIN
U.N.O.
VENT
VIF
VERT
VAR
VAT
WC
V
WT
WIN
WP
Typical
Underground
Tube Steel
Unfinished
Variable
Vertical
Ventilate
Verify In Field
Voltage
Water Closet
Weight
Window
Waterproof
T Tread
FINISHED WOOD
ROUGH FRAMING OR
ROUGH SAWN TRIM
WOOD BLOCKING
CONCRETE
STONE
TILE
GLAZING
FRAME WALL
CONCRETE MASONRY
PARTICLE BD. OR
GLU-LAM WOOD
WOOD FIBER BD.
RIGID INSULATION
CARPET
ACOUSTICAL CEILING
STEEL
PLYWOOD
SHEET METAL
BATT INSULATION
GYP. WALL BOARD/
STUCCO/ PLASTER
ALUMINUM OR
SECTION PLAN
SECTION PLAN
ROCK/
SOIL/ COMPACTED FILL
SAND
NON-COMPACTED FILL
CLIENT
Issue Date:
ELEV. 100'-0"
T.O. PWD.
SITE ELEV. = 116'-0"
Power Actuated Fastened
PAF
Issue
Date
PROJECT INFORMATION
International Milling Ltd.
Rio de la Plata 401 Ote.
Col. del Valle, San Pedro Garza Garcia,
N.L.
Mexico, C.P. 66220
Attn: Salvador Vargas Guajardo
Owners Project Manager- Dean Koll
Phone: (970) 376-1297
E-mail: dean@dkollarchitect.com
SURVEYOR
Archibeque Land Consulting, Ltd
Contact: Ted Archibeque
105 Capitol Street
Suite 5 - P.O. Box 3893
Eagle, CO 81631
Phone: (970) 328-6020
SOIL ENGINEER
HP GEOTECH
Contact: Steve Pawlack
5020 Cty Rd 154
Glenwood Springs, CO 81601
Phone: (970) 945-7988
Fax: (970) 945-8454
E-mail: hpgeo@hpgeotech.com
CONTRACTOR
Vail Custom Builders
Contact: Ted Leach
0429 Edwards Access Road
Northstar Center A207
PO Box 2809
Edwards, Colorado 81632
Mobile: (970) 376-0802
Office: (970) 926-8771 x5
E-mail: ted@vailcustom.com
STRUCTURAL ENGINEER
LANDSCAPE ARCHITECT
KRM Consultants Inc.
Contact: Tim Hennum
P.O. Box 4572
Vail, CO 81658
Office: (970) 949-9391
Fax: (970 949-0839
E-mail: tdh@krmconsultants.com
MECHANICAL ENGINEER
CODE: 2012 IRC, 2012 IEC OCCUPANCY TYPE: SINGLE FAMILY HOME
ENERGY CONSERVATION: THE BUILDING COMPLIES WITH THE ENERGY CONSERVATION REQUIREMENT FROM CHAPTER 4 OF THE 2012 INTERNATIONAL ENERGY CODE PER ZONE 6B ADOPTED BY THE TOWN OF VAIL, AND AS
DEMONSTRATED BY REScheck SOFTWARE, AS FOLLOWS:
The following is a summary for the climate zone 6B of Table 402.1.1 requirements of the IEC and as adopted by The Town of Vail, and an outline of the proposed R values of the assemblies of the building which are defined in the Construction Document
Drawings and Specifications:
Maximum Glazing U-Factor of .30 for new single family dwelling units per Town of Vail amendments, this can be a weighted average.
Ceilings & Roofs Insulation - Requirement of R-49 which is reduced to R-38 per 402.2.1 since the construction techniques provide a full R-38 insulation value over the wall top plate.
@ Typical Roof Condition - The design provides a full R-38 insulation value over the wall top plate as follows: Provide R62.4 at roof Cavities with 5/8" plywood over 14” TJIs: Provide R62.4 with 4” minimum of 2# closed cell spray foam
insulation with an R value of 6.6 per inch equaling R26.4 and 10” of blown in cellulose insulation with R3.6 per inch equaling R36.
Basement Walls Insulation - Requires R-15 of continuous insulation or R-19 cavity insulation : Provide R22.6 with R-10 exterior insulation/drainage medium over the typical 8" concrete wall and R-14.4 at 2x4 wood furring with 4" blown in cellulose insulation
with R-3.6 per inch and 5/8" drywall exceeds the requirement.
Exterior Walls Insulation - Requires R-20: Exterior walls with 5.5” cavity: Provide R25.8 with 2” minimum of spray foam insulation @ inside of sheathing with an R value of 6.6 per inch equaling R13.2 and 3.5” of blown in cellulose insulation with R3.6 per
inch equaling R12.6 or approved equal.
Floor Insulation - Requires R-30: The building has been designed with a conditioned and finished basement space.
@ Floor over Outdoor Room & Master Bedroom Overhang - Provide 2" min. spray foam insulation @ underside of floor sheathing w/ an R-Value of 6.6 per inch equaling 13.2 and 12" of blown in cellulose insulation w/ R-3.6 per inch equaling
R-43.2 providing a total insulation value of R-56.4.
Basement Slab - Requires R-15 for 4' horizontally under slab (since the slab is heated). Provide R15 with continuous 3" rigid insulation under the slab and R-10 continuous @ exterior of foundation.
Provide full cavity blown in cellulose sound insulation at all interior walls and at all floor assemblies.
ADDITIONAL REQUIREMENTS PER TOWN OF VAIL CODE AMENDMENTS:
ROOF COVERING: Meets Section 1505.6 of the Town of Vail Code- Standing seam roofing will be installed to meet the required Class A roof or Class A roof assembly.
FIRE SPRINKLER SYSTEM: Building is to be equipped throughout with an automatic sprinkler system installed in accordance with NFPA 13 and the Town of Vail. A monitored fire alarm system will also be provided.
PLUMBING: See plumbing documents from Plumbing Contractor
MECHANICAL: See mechanical documents from Mechanical Contractor
ELECTRICAL: See load calculations from electrical contractor for service and electric panel sizing
CODE INFORMATION
BERGLUND ARCHITECTS, LLC
Contact: Hans Berglund or
Keegan Winkeller
P.O. Box 2378
210 Edwards Village Blvd.
Suite A103
Edwards, CO 81632
Office: (970) 926-4301
Fax: (970) 924-4364
E-mail: hans@berglundarchitects.com
keegan@berglundarchitects.com
DESIGN BUILD
DESIGN BUILD
7/14/2014 12:19:36 PM
A1.0
COVER
SHEET
7-14-14
BKW
HB
2722 CORTINA LANE
7-14-14
PROGRESS SET
7-14-14
PROGRESS SET
2722 CORTINA LANE
VAIL RIDGE SUBDIVISION, BLOCK B,
LOT 13 , VAIL CO
A1.0 COVER SHEET
SURVEY
ARCHITECTURAL DRAWINGS
A2.0 OVERALL SITE PLAN
A2.0B SITE PLAN
A2.1 LANDSCAPE PLAN
A2.1B LANDSCAPE DETAILS
A2.2 AREA CALCS
A3.1 LOWER LEVEL FLOOR PLAN
A3.2 MAIN LEVEL FLOOR PLAN
A3.3 UPPER LEVEL FLOOR PLAN
A3.4 ROOF PLAN
A4.1 ELEVATIONS
A4.2 ELEVATIONS
A4.3 ELEVATIONS
A4.4 ELEVATIONS
A4.5 PERSPECTIVES
A4.6 INTERIOR PERSPECTIVES
A4.7 INTERIOR PERSPECTIVES
A6.1 FOUNDATION DETAILS
A6.2 DETAILS
A6.3 ROOF DETAILS
A8.1 WINDOW AND DOOR DETAILS
A10.0 ELECTRICAL SCHEDULE AND NOTES
A10.1 LOWER LEVEL RCP
A10.2 MAIN LEVEL RCP
A10.3 UPPER LEVEL RCP
2722 Cortina Lane, Vail Ridge Subdivision, Block B, Lot 13
Zone District: Two-Family Primary/Secondary Residential ( PS )
Lot is .4376 acres, equal to 19,064 SF
Allowable GRFA
.46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.46 equals 4,600 SF
.38 SF per 1 SF of site area > 10,000 SF of site area 5,000 x 0.38 equals 1,900 SF
.13 SF per 1 SF of site area > 10,000 SF of site area 1,024 x 0.13 equals 542 SF
_______________________________________________________________________
Total Allowed Gross Residential Floor Area (GRFA) for entire lot 7,042 SF
Allowable site coverage is 20% of lot 3,812
SF
Square Footage Summary Habitable SF GRFA SF
Lower Level 1,933 SF 1,020 SF *1
Main Level 1,938 SF 1,938 SF
Upper Level 936 SF 936 SF
Double Height Space 322 SF *2
Garage 154 SF *3
____________________________________________________________________
Total 4,807 SF 4,370 SF
Provided SF Allowed SF
Garage 754 SF 600 SF
Site Coverage 3,064 SF 3,812 SF
GRFA 4,370 SF 7,042 SF
*1 52.8% OF THE LOWER LEVEL WALL IS ABOVE EXISTING OR FINISHED GRADE
WHICHEVER WAS MORE RESTRICTIVE, THEREFORE 52.8% OF THE LOWER LEVEL SF IS
COUNTED AS GRFA (LOWER LEVEL HABITABLE 1,933 SF * .528 = 1,020 SF)
*2 Double Height Space with ceiling height over 16' is counted twice. 322 SF is counted over the
Main level and shown in the GRFA calculation.
*3 154 SF of Garage Area that is over the allowable 600 SF is shown in the GRFA calculation.
Site Coverage
Allowable site coverage is 20% of lot which equals 3,812 SF. 3,064 SF is provided.
Setbacks
20' from front
15' from sides
15' from rear
Patio can extend to 1/2 the distance of the setback
Decks can encroach set back 5'
Roof or architectural projections can encroach 4'
Height
Flat or mansard roofs not to exceed 30'
Sloping roof not to exceed 33'
Garage
Allow 60 sq. ft. 754 SF is provided.
Parking Required per Chapter 10
If a dwelling unit's gross residential floor area is 4,000 square feet or more, but less than 5,500 square
feet: 4 spaces. 2 covered 9' x 18' (in garage) and 2 uncovered 9' x 19' parking spaces are provided.
See Sheet A2.1 for landscape coverage information.
REVISION SCHEDULE
# DESCRIPTION DATE
Conditions of Approval per DRB Approval of 08062014
1) The applicant shall submit a revised landscape plan,
including new plantings on the west side of the
property for staff review and approval.
2) Prior to issuance of a building permit, the applicant
shall provide to staff, for review and approval, evidence
of execution and recordation of all the necessary
easements.
DRB
APPROVED
8/6/2014 12:00:00 AM