Loading...
HomeMy WebLinkAboutDRB140275_2722 Cortina Lane - Sheet - A2-0 - OVERALL SITEPLAN_1408029120.pdfBENCHMARK: FOUND SURVEY MONUMENT 1.5" ALUMINUM CAP LS ILLEGIBLE ELEVATION 8117.89' 2" 3" 14" 14" 16" 16" 16" 8" 8" 12" 6" 6" 16" 16" 189.50' S63°29'30"W 139.38' Lot 11 Lot 12 Lot 9 8092 8100 8110 8120 81 3 0 8140 8146 8148 8150 8150 8152 8154 8156 81 5881 60 8160 8160 8162 8164 8166 8166 8168 8170 8170 8170 8172 8174 8176 8178 8180 8180 8182 8184 8186 8188 8 19 0 LOWER LEVEL DECK @ 34' - 4" MAIN LEVEL DECK @ 46' - 5" ROOF EAVE @ 58' - 0 1/8" ROOF EAVE @ 63' - 7 5/8" ROOF EAVE @ 66' - 6 5/8" ROOF EAVE @ 72' - 10 7/8" LOT 13 LOT 12 BUILDING FOOT PRINT = 2,692 SF UNHEATED ASPHALT DRIVEWAY = 1,900 SF E E E ELECTRICAL CLOSET GAS METER LOCATION EXISTING GRADE @ 61' - 7 7/8" ROOF EAVE @ 58' - 0 1/8" *4 *2 EXISTING GRADE @ 26' - 3 1/8" EXISTING GRADE @ 29' - 2 1/8" (5) DECIDUOUS TREES TO BE REMOVED LAWN *1 (2) 9'X19' SURFACE PARKING SPACES ROOF EAVE @ 72' - 10 7/8" FINISHED GRADE @ 53' - 1 7/8" *3 (2) 9' X 18' ENCLOSED PARKING SPACES S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S PHONE PEDESTAL TV PEDESTAL SEWER LIFT STATION PER MECHANICAL ENGINEER EXISTING GRADE @ 39' - 9" P P P P P P P P P P P P P P P P P P P P E G G G G G G G G G G G T T T T T T T T T T T T T T T T T T T T SIDE SETBACK 15' - 0" REAR SETBACK 15' - 0" FRONT SETBACK 20' - 0" SIDE SETBACK 15' - 0" GAS LINE CONNECTION W W W W W W W W WATER TAP CONNECTION 15' SIDE SETBACK NEW WATER LINE CONNECTION DRAINAGE SWALE 15' SIDE SETBACK 15' REAR SETBACK 20' FRONT SETBACK W W W W W W W W W W W W W W W W W W W W W W W W W W W W W UTILITY EASEMENT UTILITY EASEMENT UTITLITY EASEMENT 16' - 0" UTILITY EASEMENT 7' - 0" EXISTING RETAINING WALL PARKING PARKING PARKING N36 E14 E16 E18 E20 E22 E24 E26 E28 E30 E32 E34 E36 E38 E40 E42 E44 E46 E48 E50 E52 E54 E56 E58 E60 E62 E64 E66 E68 E70 E72 E74 E76 E78 E80 E82 E84 E86 E12 E10 E08 E06 E04 E02 E8100 E98 E96 E94 E92 E06 E08 E10 E12 E14 E16 E18 E20 E36 E38 N38 E40 N42 N44 LOWER LEVEL = 34' - 6" MAIN LEVEL = 46' - 6" UPPER LEVEL = 57' - 6" EXISTING TRANSFORMER B.O.W. 46' N46 +43'-6" +46.33' +46.16' +46' +46.16' +46.33' +47.08' +47.5' +52.16' +52' +52.16' +52.33' +50' +53.16' +53.5' +53' +54' E54 E56 E58 E60 E62 E64 E66 E68 E70 E72 E74 E76 E78 E80 E82 E84 E52 LINE OF BELOW FINISH GRADE PERMANENT SHORING WALL. APPROX. 981 SF PERMANENT SHORING WALL W/ STONE VENEER 5.3% 4.7% 2% +45' 5% +46.75' 8% 2.5% +46' 8% +46.16' +46.42' +46.42' +46.25' +45' +43' +45' 4.2% +43' +45' +45' N46 +45' 4.7% 1.3% N40 N34 N32 N30 E34 E32 E30 E28 E26 E24 E22 N28 N26 N24 N22 N12 10% 10% +59' +57' +59'+60' T.O.W 63.25' B.O.W 58.25' B.O.W 53.25' T.O.W 57.25' 6' TALL BOULDER RETAINING WALLS TO BE ENGINEERED BY KRM CONSULTANTS +54' +56' T.O.W 20' B.O.W 16' LIMIT OF DISTURBANCE LIMIT OF DISTURBANCE LIMIT OF DISTURBANCE LIMIT OF DISTURBANCE LIMIT OF DISTURBANCE SNOW STORAGE AREA 688 SF. SHOWN WITH HATCH GENERAL NOTES: LOT SIZE IS .4376 ACRES EQUAL TO 19,064 SF 1.) SEE A2.1 LANDSCAPE PLAN FOR GENERAL LANDSCAPE, GRADING, AND EROSION CONTROL NOTES 2.) EXTERIOR LIGHTING- 1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 20 LIGHTS ARE ALLOWED. 20 EXTERIOR LIGHTS 18" ABOVE GRADE ARE PROPOSED. SEE ELEVATIONS AND PLANS FOR TYPE, LOCATION AND NUMBER OF FIXTURES. 3.) ROOF HEIGHT CALCULATIONS (ALSO SHOWN ON ROOF PLAN): MEASURED TO TOP OF SHEATHING ON TOP OF STRUCTURAL ROOF TO FINISHED OR EXISTING GRADE DIRECTLY BELOW (WHICHEVER IS MORE RESTRICTIVE). APPROX. 1" OF ROOFING. *1- ROOF EAVE HEIGHT @ SHEATHING = 8158' - 0 1/8" EXISTING GRADE BELOW EAVE = 8129' - 2 1/8" ROOF HEIGHT = 28' - 10" *2- ROOF EAVE HEIGHT @ SHEATHING = 8158' - 0 1/8" EXISTING GRADE BELOW EAVE = 8126' - 3 1/8" ROOF HEIGHT = 31'- 9" *3- ROOF EAVE HEIGHT @ SHEATHING = 8172'- 10 7/8" FINISH GRADE BELOW EAVE = 8153'- 1 7/8" ROOF HEIGHT = 19' - 9" *4- ROOF EAVE HEIGHT @ SHEATHING = 8172'- 10 7/8" EXISTING GRADE BELOW EAVE = 8161'- 7 7/8" ROOF HEIGHT = 11' -3" 4.) LANDSCAPE AREA CALCULATIONS: LOT SIZE 19,064 SF 10% MAXIMUM DRIVEWAY AND AUOTCOURT COVERAGE ALLOWED ON SITE WITH AVERAGE SLOPE OF 30% OR MORE PER TOWN OF VAIL CODE 12-21-12 DRIVEWAY AND AUTOCOURT PROPOSED 1,900 SF LOT DISTURBANCE ALLOWED 1,906 SF 60% MAXIMUM LOT DISTURBANCE ALLOWED ON SITE WITH AVERAGE SLOPE OF 30% OR MORE PER TOWN OF VAIL CODE 12-21-12 LOT DISTURBANCE PROPOSED 11,367 SF LOT DISTURBANCE ALLOWED 11,438 SF ____________________________________________________________ TOTAL LOT SIZE = 19,064 SF BUILDING FOOTPRINT / 2,692 SF TOTAL HARDSCAPE 2,514 SF ______________________________________________ TOTAL SOFTSCAPE AREA PROVIDED 14,391 SF 5.) SNOW STORAGE CALCULATIONS: IF DRIVE WAY IS NOT HEATED 30% OF THE TOTAL DRIVEWAY ARE MUST BE SNOW STORAGE TOTAL UNHEATED DRIVEWAY AREA= 1,981 SF THEREFORE 594.3 SF IS NEEDED FOR SNOW STORAGE TOTAL SNOW STORAGE AREA PROVIDED= 688 SF, WHICH EXCEEDS THE REQUIREMENT OF 594.3 SF. 6.) TOTAL NUMBER OF TREES BEING REMOVED IS 5: (TREES BEING REMOVED ALSO SHOWN ON LANDSCAPE PLAN) 5 DECIDUOUS 0 CONIFEROUS 7.) SEE MAIN LEVEL FLOOR PLAN FOR ADDITIONAL GRADE / DRIVEWAY / WALL ELEVATION NOTES 8.) SEE A3.1, A3.2, and A3.3 FOR MICRO GRADING AT BUILDING EDGE AND AT DECKS. Scale Date Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com As indicated 8/4/2014 11:23:53 AM A2.0 OVERALL SITEPLAN 2722 CORTINA LANE 7-14-14 BKW HB VAIL RIDGE SUBDIVISION, BLOCK B, LOT 13 , VAIL CO 1/16" = 1'-0" 1 OVERALL SITE PLAN 0' 4' 8' 16' 32' REVISION SCHEDULE # DESCRIPTION DATE 1 1 1 1 Revised boulder walls within building set back to be less than 3' tall, showed 16' utility easement on west property line, moved west deck to be more than 10' from west property line, revised snow storage at autocourt parking, added steep slope site analysis, indicated driveway in not heated, added hardscape calculation. Revised driveway and autocourt to be less than 10% of total site. Reduced limit of disturbance to be less than 60% of total site. DRB APPROVED 8/6/2014 12:00:00 AM