HomeMy WebLinkAboutDRB140275_2722 Cortina Lane - Sheet - A3-1 - LOWER LEVEL FLOOR PLAN_1408029120.pdfUP UP E24 E26 E28 N44 B.O.W. 46' +43'-6" +46.33' +46.16' +46' LINE OF BELOW FINISH GRADE PERMANENT SHORING WALL. APPROX. 981 SF 5.3% 2% +46.42' +46.25' +45' 4.2% N46 T.O.W 22' DRIVEWAY = 1,981 SF LINE OF DECK @ LOWER LEVEL LINE OF DECK @ MAIN LEVEL 8150 8160 A4.3 A4.1 1 1 A4.2 1 A4.4 1 4' - 4 1/2" 4' - 1 3/4" 4' - 2" 12' - 0" 17' - 1" 3' - 5" 3' - 7" 5' - 1" 5' - 9" 3' - 3 1/2" 5' - 0" 3' - 7 1/4" 1' - 0" 3' - 11" 12' - 5" 12' - 10 1/2" 2' - 2" 3' - 7" 8' - 5 1/2" 8' - 6" 3' - 7" 12' - 3" 3' - 1" 3' - 8 1/2" 4' - 6" 5' - 1" 5' - 2 1/2" 4' - 8" 6' - 4 1/2" BENCH 5' - 7" MECH 001 LAUNDRY 002 CLOSET 003 BATH 2 004 BEDROOM 2 005 BEDROOM 3 006 FAMILY ROOM 011 BEDROOM 4 012 BATH 4 013 CLOSET 014 STAIRS 010 BATH 3 009 CLOSET 007 CLOSET 008 LINE OF FLOOR ABOVE FD 34' - 4" 1' - 3" 5' - 3 3/8" 12' - 11 1/2" SHOWER 143 LINE OF DECK ABOVE LINE OF DECK ABOVE LINE OF GARAGE ABOVE LINE OF GARAGE ABOVE BENCH FD 1' - 7" 8' - 9 11/16" OPENING UNDER STAIRS FOR KIDS PLAY AREA AND STORAGE WASHER DRYER 12' - 10 1/2" 8' - 3 3/4" 9' - 7 1/2" 11' - 3 1/2" 2' - 8 13/16" 34' - 5 1/4" T.O. FINISHED FLOOR @ 34' - 6" LINE OF ROOF ABOVE FRIDGE 2' - 1 1/2" FLOOR TO CEILING CABINET LAUNDRY CHUTE FROM MAIN LEVEL 4' - 0" 3' - 6" 2' - 0" 2' - 0" BROOM CLOSET CONC. STEM WALL FOR STRUCTURAL SLAB @ FRNT ENTRY RE: STRUCT. 1/2" AIR SPACE BTW CONC. WALL AND FURRING TYP. 4' - 0" 4' - 0" GAS METER PAINTED TO MATCH STONE VENEER ELECTRICAL CLOSET 1 1 2 2 3 3 4 4 5 6 6 7 7 8 8 9 9 10 10 A B C D E F G H I Q Q Q RADON MITIGATION SYSTEM PROVIDE DESIGN-BUILD ENGINEERING AND CONSTRUCTION OF A PASSIVE RADON MITIGATION SYSTEM FOR THE PROJECT TO WHICH AN INLINE FAN COULD BE ADDED LATER IF REQUIRED PER THE FOLLOWING CRITERIA AND AS REQUIRED TO MAINTAIN RADON LEVELS AT THE MECHANICAL ROOM, LOWER LEVEL AND HOUSE BELOW EPA AND OTHER GOVERNMENT STANDARDS. THE RADON MITIGATION SUBCONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH THE VAPOR BARRIER INSTALLATION AND THE ELECTRICIAN FOR AN ELECTRICAL JUNCTION BOXES AT THE LOCATIONS DETERMINED BY THE RADON MITIGATION SUBCONTRACTOR FOR THE POTENTIAL FUTURE FANS. AT A MINIMUM, THE FOLLOWING SYSTEMS/SERVICES WILL BE PROVIDED AS PART OF THE BASE BID BY THE RADON MITIGATION SUB CONTRACTOR. - SEALING OF THE LOWER LEVEL CONCRETE SLAB TO THE FOUNDATION WALLS - SEALING OF ALL PLUMBING AND OTHER PENETRATIONS THROUGH THE CONCRETE SLABS AND THROUGH THE BELOW GRADE PORTIONS OF THE FOUNDATION WALL - LOCATIONS & INSTALLATION OF PIPES, PORTS, AND OPENINGS IN THE SLAB FOR SLAB DEPRESSURIZATION SYSTEM. - PROVIDE PASSIVE VENT PIPE SYSTEM WHICH RUNS FROM THE SLAB PENETRATION LOCATIONS(S) TO THE OUTSIDE IN ACCORDANCE WITH THE EPA STANDARDS. THE VENTS SHALL BE RUN WITHIN THE INTERIOR OR EXTERIOR WALLS TO A LOCATION(S) HIGH ON THE ROOF. COORDINATE VENT LOCATIONS WITH ARCHITECT AND/OR OWNER - PROVIDE POWER ADJACENT TO SLAB VENT PENETRATIONS FOR POTENTIAL FUTURE INLINE FAN LOCATION INCLUDING ALL REQUIRED ROUGH IN WIRING AND JUNCTION BOXES, IN THE EVENT THAT A FAN IS REQUIRED TO BE INSTALLED - PROVIDE PROVISIONS FOR A SYSTEM FAILURE INDICATOR, INCLUDING ALL REQUIRED ROUGH-IN WIRING, AND JUNCTION BOXES, IN THE EVENT THAT A FAN IS REQUIRED TO BE INSTALLED. - PERFORM RADON TESTING AFTER THE HOME/PASSIVE SYSTEM IS COMPLETE TO DETERMINE IF THE HOME PASSES OR IF AN ACTIVE SYSTEM IS REQUIRED IN ORDER TO MAINTAIN RADON BELOW EPA AND OTHER GOVERNMENTAL STANDARDS. - IF AN ACTIVE SYSTEM IS REQUIRED, PERFORM FOLLOW UP RADON TESTING AFTER THE SYSTEM IS COMPLETE TO DETERMINE IF RADON HAS BEEN MITIGATED - PROVIDE AND INLINE FAN IF ACTIVE SYSTEM IS REQUIRED. PROVIDE OTHER EQUIPMENT AND SYSTEM AS REQUIRED TO PROVIDE A FUNCTIONAL RADON MITIGATION SYSTEM FOR THE UNITS. CONTRACTOR TO COORDINATE INSTALLATION OF THE 10 MIL VAPOR BARRIER UNDER THE SLAB INCUDING THE SEALING OF ALL JOINTS, ALL PLUMBING OR MECHANICAL OR OTHER PENETRATIONS AND THE SEALING AND MECHANICAL FASTENING OF THE VAPOR BARRIER TO THE EXTERIOR CONCRETE FOUNDATION WALLS. RE: OUTLINE SPEC FOR MORE DETAILS Scale Date Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com 1/4" = 1'-0" 7/14/2014 12:20:41 PM A3.1 LOWER LEVEL FLOOR PLAN 2722 CORTINA LANE 7-14-14 BKW HB VAIL RIDGE SUBDIVISION, BLOCK B, LOT 13 , VAIL CO 1/4" = 1'-0" 1 LOWER LEVEL PLAN 0' 2' 4' 8' 16' REVISION SCHEDULE # DESCRIPTION DATE DRB APPROVED 8/6/2014 12:00:00 AM