HomeMy WebLinkAboutDRB140275_2722 Cortina Lane - Sheet - A3-1 - LOWER LEVEL FLOOR PLAN_1408029120.pdfUP
UP
E24
E26
E28
N44
B.O.W. 46'
+43'-6"
+46.33'
+46.16' +46'
LINE OF BELOW
FINISH GRADE
PERMANENT
SHORING WALL.
APPROX. 981 SF
5.3%
2%
+46.42'
+46.25'
+45'
4.2%
N46
T.O.W 22'
DRIVEWAY = 1,981 SF
LINE OF DECK @ LOWER LEVEL
LINE OF DECK @ MAIN LEVEL
8150
8160
A4.3
A4.1
1
1
A4.2
1
A4.4
1
4' - 4 1/2"
4' - 1 3/4" 4' - 2"
12' - 0"
17' - 1"
3' - 5" 3' - 7"
5' - 1"
5' - 9"
3' - 3 1/2"
5' - 0"
3' - 7 1/4"
1' - 0"
3' - 11"
12' - 5" 12' - 10 1/2"
2' - 2"
3' - 7"
8' - 5 1/2"
8' - 6" 3' - 7"
12' - 3"
3' - 1"
3' - 8 1/2" 4' - 6"
5' - 1"
5' - 2 1/2" 4' - 8"
6' - 4 1/2"
BENCH
5' - 7"
MECH
001
LAUNDRY
002
CLOSET
003
BATH 2
004
BEDROOM 2
005
BEDROOM 3
006
FAMILY ROOM
011
BEDROOM 4
012
BATH 4
013
CLOSET
014
STAIRS
010
BATH 3
009
CLOSET
007
CLOSET
008
LINE OF FLOOR ABOVE
FD
34' - 4"
1' - 3"
5' - 3 3/8"
12' - 11 1/2"
SHOWER
143
LINE OF DECK ABOVE
LINE OF DECK ABOVE
LINE OF GARAGE ABOVE
LINE OF GARAGE ABOVE
BENCH FD
1' - 7"
8' - 9 11/16"
OPENING UNDER STAIRS
FOR KIDS PLAY AREA
AND STORAGE
WASHER DRYER
12' - 10 1/2"
8' - 3 3/4"
9' - 7 1/2"
11' - 3 1/2"
2' - 8 13/16"
34' - 5 1/4"
T.O. FINISHED FLOOR @ 34' - 6"
LINE OF ROOF ABOVE
FRIDGE
2' - 1 1/2"
FLOOR TO CEILING CABINET
LAUNDRY CHUTE FROM
MAIN LEVEL
4' - 0"
3' - 6"
2' - 0"
2' - 0"
BROOM CLOSET
CONC. STEM WALL FOR
STRUCTURAL SLAB @ FRNT
ENTRY RE: STRUCT.
1/2" AIR SPACE BTW CONC.
WALL AND FURRING TYP.
4' - 0"
4' - 0"
GAS METER
PAINTED TO MATCH
STONE VENEER
ELECTRICAL CLOSET
1
1
2
2
3
3
4
4 5
6
6
7
7
8
8
9
9
10
10
A
B
C
D
E
F
G
H
I
Q
Q
Q
RADON MITIGATION SYSTEM
PROVIDE DESIGN-BUILD ENGINEERING AND CONSTRUCTION OF A PASSIVE RADON MITIGATION SYSTEM FOR THE PROJECT TO WHICH AN INLINE FAN
COULD BE ADDED LATER IF REQUIRED PER THE FOLLOWING CRITERIA AND AS REQUIRED TO MAINTAIN RADON LEVELS AT THE MECHANICAL ROOM,
LOWER LEVEL AND HOUSE BELOW EPA AND OTHER GOVERNMENT STANDARDS. THE RADON MITIGATION SUBCONTRACTOR WILL BE RESPONSIBLE
FOR COORDINATING HIS WORK WITH THE VAPOR BARRIER INSTALLATION AND THE ELECTRICIAN FOR AN ELECTRICAL JUNCTION BOXES AT THE
LOCATIONS DETERMINED BY THE RADON MITIGATION SUBCONTRACTOR FOR THE POTENTIAL FUTURE FANS.
AT A MINIMUM, THE FOLLOWING SYSTEMS/SERVICES WILL BE PROVIDED AS PART OF THE BASE BID BY THE RADON MITIGATION SUB CONTRACTOR.
- SEALING OF THE LOWER LEVEL CONCRETE SLAB TO THE FOUNDATION WALLS
- SEALING OF ALL PLUMBING AND OTHER PENETRATIONS THROUGH THE CONCRETE SLABS AND THROUGH THE BELOW GRADE PORTIONS OF THE
FOUNDATION WALL
- LOCATIONS & INSTALLATION OF PIPES, PORTS, AND OPENINGS IN THE SLAB FOR SLAB DEPRESSURIZATION SYSTEM.
- PROVIDE PASSIVE VENT PIPE SYSTEM WHICH RUNS FROM THE SLAB PENETRATION LOCATIONS(S) TO THE OUTSIDE IN ACCORDANCE WITH THE EPA
STANDARDS. THE VENTS SHALL BE RUN WITHIN THE INTERIOR OR EXTERIOR WALLS TO A LOCATION(S) HIGH ON THE ROOF. COORDINATE VENT
LOCATIONS WITH ARCHITECT AND/OR OWNER
- PROVIDE POWER ADJACENT TO SLAB VENT PENETRATIONS FOR POTENTIAL FUTURE INLINE FAN LOCATION INCLUDING ALL REQUIRED ROUGH IN
WIRING AND JUNCTION BOXES, IN THE EVENT THAT A FAN IS REQUIRED TO BE INSTALLED
- PROVIDE PROVISIONS FOR A SYSTEM FAILURE INDICATOR, INCLUDING ALL REQUIRED ROUGH-IN WIRING, AND JUNCTION BOXES, IN THE EVENT THAT
A FAN IS REQUIRED TO BE INSTALLED.
- PERFORM RADON TESTING AFTER THE HOME/PASSIVE SYSTEM IS COMPLETE TO DETERMINE IF THE HOME PASSES OR IF AN ACTIVE SYSTEM IS
REQUIRED IN ORDER TO MAINTAIN RADON BELOW EPA AND OTHER GOVERNMENTAL STANDARDS.
- IF AN ACTIVE SYSTEM IS REQUIRED, PERFORM FOLLOW UP RADON TESTING AFTER THE SYSTEM IS COMPLETE TO DETERMINE IF RADON HAS BEEN
MITIGATED
- PROVIDE AND INLINE FAN IF ACTIVE SYSTEM IS REQUIRED. PROVIDE OTHER EQUIPMENT AND SYSTEM AS REQUIRED TO PROVIDE A FUNCTIONAL
RADON MITIGATION SYSTEM FOR THE UNITS.
CONTRACTOR TO COORDINATE INSTALLATION OF THE 10 MIL VAPOR BARRIER UNDER THE SLAB INCUDING THE SEALING OF ALL JOINTS, ALL
PLUMBING OR MECHANICAL OR OTHER PENETRATIONS AND THE SEALING AND MECHANICAL FASTENING OF THE VAPOR BARRIER TO THE EXTERIOR
CONCRETE FOUNDATION WALLS.
RE: OUTLINE SPEC FOR MORE DETAILS
Scale
Date
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
1/4" = 1'-0"
7/14/2014 12:20:41 PM
A3.1
LOWER
LEVEL
FLOOR
PLAN
2722 CORTINA LANE
7-14-14
BKW
HB
VAIL RIDGE SUBDIVISION, BLOCK B,
LOT 13 , VAIL CO
1/4" = 1'-0"
1
LOWER LEVEL PLAN
0' 2' 4' 8' 16'
REVISION SCHEDULE
# DESCRIPTION DATE
DRB
APPROVED
8/6/2014 12:00:00 AM