HomeMy WebLinkAboutDRB140275_2722 Cortina Lane - Sheet - A6-1 - FOUNDATIONS DETAILS_1408029120.pdfRIGID INSULATION UNDER CONC. SLAB RE: SPEC PRESSURE TREATED WOOD LEDGER PRESSURE TREATED PLATE FURRED 2X4 WALL SET 1/2" OFF CONC. WALL ENTIRE CAVITY FILLED WITH INSULATION RE: SPEC CONC. WALL RE: STRUCT. W.P. MEMBRANE CONT. FROM B.O. FOOTING TO T.O. CONC. RE: SOILS ENGINEER FINISHED FLOOR RE: PLANS 5/8" GWB GRAVEL BED PER SOILS ENGINEER SLOPE T.O. CONRETE SLAB RE: FLOOR PLANS T.O. PLYWOOD RE: FLOOR PLANS INTERIOR INTERIOR EXTERIOR RE: STRUCT RE: STRUCT. STEEL LEDGER RE: STRUCT . GRID LINE SLOPE GRADE @ 10% AWAY FROM BUILDING FOR MIN. 10' PER SOILS ENGINEER STONE VENEER RE:A6.1 AND ELEVATIONS MIN. R-10 RIGID INSULATION/DRAINAGE BOARD RE: SPEC NO VAPOR BARRIER @ LOWER LEVEL/SUBGRADE WALLS 2" RIGID INSULATION @ EDGE OF CONC. SLAB RE: SPEC RECLAIMED SIDING RE: SPEC RE: DETAILS ON A6.3 & ELEVATIONS FOR WALL ASSEMBLY & TRANSITION HEIGHT 3D DRAINAGE MATERIAL CONT. BEHIND SIDING AND STONE VENEER FLASHING EXTENDS UP BEHIND AIR INFILTRATION BARRIER MIN. 4", AND EXTENDS OUT OVER STONE MIN. 3" APPROX. 2" THICK STONE CAP WITH TOP SLOPED MIN 10%. EXTENDS BEYOND APPROX. 1" NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES SLOPE 1/8" : 1'-0" MIN 6" RE: STRUCT. RE: STRUCT. RE: STRUCT. INTERIOR GRID LINE T.O. SLAB RE: FLOOR PLANS 5" FINISH FLOOR RE: FLOOR PLANS AND SPEC STEEL LEDGER RE: STRUCT. COAT W/ DAMPPROOFING TYP. LAP ICE & WATER SHIELD MIN. 6" OVER CONC. FDTN. & EXTEND UP WALL TO MIN. 30" ABOVE T.O. CONC. STONE VENEER ATTACHED PER IRC R703.7 OVER 3D DRAINAGE MATERIAL OVER AIR AND WATER INFILTRATION BARRIER CONT. @ WALL. LAP OVER 30" HIGH ICE & WATER SHIELD WHICH IS CONT. @ BTM WALL. MIRADRAIN DRAINAGE MEDIUM CONT. UNDER B.O. STONE @ CONCRETE LEDGE (OR STEEL ANGLE WHERE APPLICABLE) OR PROVIDE WEEP SO THAT DRAINAGE MEDIUM CAN DRAIN AT BO WALL. CONCRETE SLAB W/ IN FLOOR RADIANT HEAT RE: STRUCT. 3" RIGID FOAM INSULATION CONTINUOUS UNDER SLAB RE: SPEC CONCRETE FOUNDATION WALL RE: STRUCTURAL DRAWINGS CONCRETE FOUNDATION PIER RE: STRUCTURAL DRAWINGS MIRA DRAIN DRAINAGE MEDIUM OVER MIN. R-10 RIGID FOAM INSULATION PANEL RE: SPEC OVER WATERPROOF MEMBRANE. ALTERNATE MIN R-10 COMBINATION INSULATION / DRAINAGE MEDIUM MAY BE PROPOSED PER SPEC. 4" DIA. RIGID PERFORATED PIPE SURROUNDED BY FILTER FABRIC AND A MIN. OF 4 INCHES OF DRAIN GRAVEL SLOPED 1% MIN. TO DAYLIGHT PER SOILS REPORT. RE SOILS REPORT FOR ADDITIONAL FOUNDATION & PERIMETER DRAIN REQUIREMENTS & SPEC W.P. MEMBRANE CONT. FROM B.O. WALL TO T.O. CONC. WALL 10 MIL VAPOR BARRIER TURNS UP WALL MECH FASTEN AND SEAL TO WALL. SEAL ALL JOINTS AND PENETRATIONS TYP. TYPICAL FOUNDATION NOTES: 4" MIN. DRAIN GRAVEL BASE RE: SOILS ENGINEER RECOMMENDATIONS/STRUCT. MIRA DRAIN DRAINAGE MEDIUM OVER WATERPROOF MEMBRANE RE: SPEC BASE BOARD TYPICAL RE: INT. SEALANTJOINT B/W EDGE OF SLAB & WALL TO PREVENT RADON GAS INFILTRATION RE: RADON GAS MITIGATION NOTES PROVIDE 2" RIGID INSULATION HELD DOWN 1/2" @ EDGE OF SLAB W/ BEVEL CUT AS SHOWN P.T BOTTOM PLATE EXTERIOR GRADE OR PATIO SLOPE GRADE @ 10% MIN. SLOPE PATIO @ 1.25% MIN. RE:FLOORPLANS EXTERIOR SLOPE 10% MIN. FOR 10' RE: STRUCT. RE: STRUCT.RE:STRUCT STONE VENEER OVER 3D DRAINAGE MATERIAL OVER AIR AND WATER INFILTRATION BARRIER CONT. @ WALL. LAP OVER 30" HIGH ICE & WATER SHIELD WHICH IS CONT. @ BTM WALL. DRAINAGE MEDIUM CONT. UNDER B.O. STONE OR PROVIDE WEEP SO THAT DRAINAGE MEDIUM CAN DRAIN AT B.O WALL. CONC. SLAB ON GRADE RE: STRUCT INSULATION RE: SPEC INTERIOR EXTERIOR 1/2" EXPANSION JOINT @ EDGE OF GARAGE SLAB WITH BEVEL CUT TOP OF 2" FOAM @ SLAB EDGE CONC. LEDGE RE: STRUCT. GRID LINE 10 MIL VAPOR BARRIER TURNS UP WALL. MECHANICALLY FASTEN AND SEAL TO WALL. SEAL ALL JOINTS AND PENETRATIONS TYP. SMART MEMBRANE VAPOR BARRIER RE: SPEC MIRA DRAIN DRAINAGE MEDIUM OVER WATERPROOF MEMBRANE RE: SPEC PROVIDE MIRADRAIN CONT. @ BOTTOM OF STONE AND/OR WEEPS @ B.O STONE FOR PROPER DRAINAGE TYP. T.O. LEDGE @ 6" MIN. BELOW GRADE RE: ELEV. EXTERIOR GRADE OR PATIO SLOPE GRADE @ 10% MIN. SLOPE PATIO @ 1.25% MIN. RE:FLOORPLANS RE: STRUCT. 1/2" PLYWOOD SHEATHING ON 2X EXTERIOR WALL FRAMING RE: SPEC P.T BOTTOM PLATE LAP ICE & WATER SHIELD MIN. 6" OVER CONC. FDTN. & EXTEND UP TO MIN. 30" T.O. SLAB RE: FLOOR PLANS NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES 2X FLAT FRAME FURRING W/ 1/2" AIRSPACE BTW CONCRETE WALL PROVIDE MIN. R-10 INSULATION/DRAINAGE BOARD WHERE SLAB IS 12" OR MORE BELOW GRADE 1/4" 10" CONC. SLAB W/ IN-FLOOR RADIANT HEAT RE: STRUCTURAL DRAWINGS RIGID INSULATION UNDER CONC. SLAB RE: SPEC PRESSURE TREATED WOOD LEDGER JOIST HANGER FURRED 2X4 WALL SET 1/2" OFF CONC. WALL ENTIRE CAVITY FILLED WITH INSULATION RE: SPEC CONC. WALL RE: STRUCT. W.P. MEMBRANE CONT. FROM B.O. FOOTING RE: SOILS ENGINEER FINISHED FLOOR RE: PLANS 5/8" GWB GRAVEL BED PER SOILS ENGINEER T.O. CONRETE SLAB RE: FLOOR PLANS T.O. PLYWOOD RE: FLOOR PLANS INTERIOR INTERIOR EXTERIOR RE: STRUCT RE: STRUCT. GRID LINE PRESSURE TREATED PLATE 2" RIGID INSULATION MIN. R-10 RE: SPEC NO VAPOR BARRIER @ LOWER LEVEL/SUBGRADE WALLS SLOPE 1/8" : 1'-0" STRUCTURAL PATIO SLAB STEPPED DOWN FROM INT. SLAB RE: STRUCT. 1" DOOR SILL SET IN BED OF SEALANT OVER COPPER FLASHING NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES 2" RIGID INSULATION HELD DOWN 1/2" @ EDGE OF CONC. SLAB SEE 2/A6.1 FOR TYP. STONE PATIO ASSEMBLY 1 1/2" 2 1/2" 5 1/2" CONC. SLAB W/ IN-FLOOR RADIANT HEAT RE: STRUCTURAL DRAWINGS RIGID INSULATION UNDER CONC. SLAB RE: SPEC PRESSURE TREATED WOOD LEDGER JOIST HANGER FURRED 2X4 WALL SET 1/2" OFF CONC. WALL ENTIRE CAVITY FILLED WITH INSULATION RE: SPEC CONC. WALL RE: STRUCT. RE: SOILS ENGINEER FINISHED FLOOR RE: PLANS 5/8" GWB T.O. CONRETE SLAB RE: FLOOR PLANS T.O. PLYWOOD RE: FLOOR PLANS INTERIOR INTERIOR EXTERIOR RE: STRUCT RE: STRUCT. GRID LINE PRESSURE TREATED PLATE MIN. R-10 RIGID INSULATION/ DRAINAGE MEDIUM RE: SPEC NO VAPOR BARRIER @ LOWER LEVEL/SUBGRADE WALLS PFSM CLAD PANEL RE: ELEVATIONS & SPEC PFSM FLASHING RE: SPEC TURN UP WALL 6" MIN. NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES 8" RE: STRUCT 1/2" 2 1/2" 5 1/2" 3 1/4" 3" STONE PATIO ASSEMBLY OVER STRUCTURAL SLAB. RE: STRUCT. 1" RIGID INSULATION UNDER CONC. SLAB RE: SPEC PRESSURE TREATED PLATE FURRED 2X4 WALL SET 1/2" OFF CONC. WALL ENTIRE CAVITY FILLED WITH INSULATION RE: SPEC CONC. WALL RE: STRUCT. W.P. MEMBRANE CONT. FROM B.O. FOOTING TO T.O. CONC. RE: SOILS ENGINEER FINISHED FLOOR RE: PLANS 5/8" GWB GRAVEL BED PER SOILS ENGINEER SLOPE T.O. CONRETE SLAB RE: FLOOR PLANS T.O. PLYWOOD RE: FLOOR PLANS INTERIOR INTERIOR EXTERIOR RE: STRUCT RE: STRUCT. STEEL LEDGER RE: STRUCT . GRID LINE SLOPE GRADE @ 10% AWAY FROM BUILDING FOR MIN. 10' PER SOILS ENGINEER STONE VENEER RE:A6.1 AND ELEVATIONS MIN. R-10 RIGID INSULATION/DRAINAGE BOARD RE: SPEC NO VAPOR BARRIER @ LOWER LEVEL/SUBGRADE WALLS 2" RIGID INSULATION @ EDGE OF CONC. SLAB RE: SPEC RECLAIMED SIDING RE: SPEC RE: DETAILS ON A6.3 & ELEVATIONS FOR WALL ASSEMBLY & TRANSITION HEIGHT 3D DRAINAGE MATERIAL CONT. BEHIND SIDING AND STONE VENEER FLASHING EXTENDS UP BEHIND AIR INFILTRATION BARRIER MIN. 4", AND EXTENDS OUT OVER STONE MIN. 3" APPROX. 2" THICK STONE CAP WITH TOP SLOPED MIN 10%. EXTENDS BEYOND APPROX. 1" NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES Scale Date Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com 1 1/2" = 1'-0" 7/14/2014 12:25:09 PM A6.1 FOUNDATIONS DETAILS 2722 CORTINA LANE 7-14-14 BKW HB VAIL RIDGE SUBDIVISION, BLOCK B, LOT 13 , VAIL CO 1 1/2" = 1'-0" 1 FOUNDATION DETAIL @ JOIST HANGING FROM CONC. WALL 1 1/2" = 1'-0" 3 FOUNDATION DETAIL - TYPICAL 1 1/2" = 1'-0" 5 FOUNDATION DETAIL @ STAIR WELL 1 1/2" = 1'-0" 2 FOUNDATION DETAIL @ FRONT ENTRY DOOR THRESHOLD 1 1/2" = 1'-0" 6 FOUNDATION DETAIL @ FRONT ENTRY SIDELITE WINDOWS 1 1/2" = 1'-0" 7 FOUNDATION DETAIL @ JOIST BEARING ON CONC. WALL REVISION SCHEDULE # DESCRIPTION DATE DRB APPROVED 8/6/2014 12:00:00 AM