HomeMy WebLinkAboutDRB140275_2722 Cortina Lane - Sheet - A6-3 - ROOF DETAILS_1408029120.pdfCUSTOM 5" ROUND GUTTER WITH
ROUND DOWN SPOUTS RE: SPEC
RE: ROOF PLANS FOR LOCATIONS
RE: ROOF PLAN / SECTIONS
GRID
LINE
DRIP EDGE FLASHING
RE: SPEC
STANDING STEAM ROOF
RE: SPEC RE: ROOF PLAN
FOR LOCATIONS
ICE AND WATER SHIELD OVER
METAL FLASHING PROVIDE
50% OVERLAP (DOUBLE
LAYER) FOR FIRST 4' UP EAVE
2X6 DOUG-FIR DECKING
2X6 CEDAR FASCIA RE: ROOF
PLAN FOR LOCATIONS
6x10 ROUGH SAWN DOUG-FIR RAFTER TAILS @
48" O.C. PORTER STAIN COLOR SIERRA BROWN.
RAFTERS SISTERED TO TJI RAFTERS TYP.
INSULATION RE: SPEC & COVER SHEET
RECLAIMED WOOD SIDING (REFER TO
ELEVATIONS FOR LOCATIONS) MIX OF
1X8, 1X10, AND 1X12 SHIP LAP NO
REVEAL SIDING RE: SPEC
EXTEND ROOF SHEATHING TO EDGE OF EAVE
PLATE HEIGHTS AT SECTIONS AND
ELEVATIONS ARE PER A BEVEL PLATE
(RAFTER NOT SEAT CUT)
2.5:12
PER ROOF PLAN
3D DRAINAGE MEDIUM CONT. BEHIND SIDING TO
AIR VENT MATERIAL AT TOP OF WOOD SIDING
SMART MEMBRANE VAPOR BARRIER
TYP. RE: SPEC
PRE FINISHED METAL GUTTER AND
DOWN SPOUT RE: SPEC
PFSM DRIP EDGE FLASHING
RE: SPEC
STANDING STEAM METAL ROOF RE:
SPEC AT 1.5:12
ICE AND WATER SHIELD OVER
METAL FLASHING PROVIDE
50% OVERLAP (DOUBLE
LAYER) FOR FIRST 4' UP FROM
EAVE
2X6 DOUG-FIR DECKING
2X6 CEDAR FASCIA
6X10 ROUGH SAWN DOUG-
FIR RAFTER TAIL RE: RCP &
ELEVATIONS
RAFTERS BIRDS MOUTH CUT TO
ALLOW I-BEAM TO SIT FLUSH
10X10 DOUG-FIR COLUMN @
SHED ROOF OVER DECK AT
MAIN FLOOR
STEEL I-BEAM RE: STRUCT.
RE: ROOF PLAN
KNIFE PLATE WITH SURFACE
MOUNTED THROUGH BOLTS RE:
STRUCT.
KNIFE PLATE WITH SURFACE
MOUNTED THROUGH BOLTS RE:
STRUCT.
12
2.5"
EXTEND ROOF SHEATHING TO EDGE OF EAVE
9 1/4"
3"
4X4 TUBE STEEL FULLY
WELDED TO 8 1/2" X 8 1/2" X
1/2" STEEL CAP W/ KNIFE
PLATE RE: STRUCT.
4X4 TUBE STEEL BEVEL PLATE
GRID
LINE
6X10 RAFTER TAIL ATTACHED
TO WOOD RAFTERS @ 48" O.C.
RE: STRUCTURAL DRAWINGS
DRIP FLASHING OVER FASCIA RE: SPEC
STANDING SEAM METAL ROOFING
RE: SPEC
5/8" PLYWOOD SHEATHING
INSULATION RE: SPEC
6X10 WOOD RAFTER LAG
BOLTED TO EXTERIOR WALL -
LAG BOLTS TO BE COUNTER
SUNK AND PLUGGED
2X4 BLOCKING
PLYWOOD BLOCKING
EXTEND ROOF SHEATHING
TO EDGE OF ROOF
TYP. EXTERIOR WALL ASSEMBLY RE:
ELEVATIONS / SECTIONS
CANTILEVERED 2X6 T&G
DECKING
VARIES PER OVERHANG
RE: ROOF PLAN
CONTINUOUS 2X8
CUSTOM 5" ROUND GUTTER WITH
ROUND DOWN SPOUTS RE: SPEC
RE: ROOF PLANS FOR LOCATIONS
GRID
LINE
DRIP EDGE FLASHING
RE: SPEC
STANDING STEAM ROOF
RE: SPEC RE: ROOF PLAN
FOR LOCATIONS
ICE AND WATER SHIELD OVER
METAL FLASHING PROVIDE
50% OVERLAP (DOUBLE
LAYER) FOR FIRST 4' UP EAVE
2X6 DOUG-FIR DECKING
2X6 CEDAR FASCIA RE: ROOF
PLAN FOR LOCATIONS
6x10 ROUGH SAWN DOUG-FIR RAFTER TAILS @
48" O.C. PORTER STAIN COLOR SIERRA BROWN.
RAFTERS SISTERED TO TJI RAFTERS TYP.
INSULATION RE: SPEC & COVER SHEET
WOOD SIDING (REFER TO
ELEVATIONS FOR LOCATIONS AND
TYPE) RE: SPEC
EXTEND ROOF SHEATHING TO EDGE OF EAVE
PLATE HEIGHTS AT SECTIONS AND
ELEVATIONS ARE PER A BEVEL PLATE
(RAFTER NOT SEAT CUT)
2.5:12
PER ROOF PLAN
3D DRAINAGE MEDIUM CONT. BEHIND SIDING TO
AIR VENT MATERIAL AT TOP OF WOOD SIDING
SMART MEMBRANE VAPOR BARRIER
TYP. RE: SPEC
T.O. WALL
RE: SECTS AND ELEVS
WOOD SIDING (REFER TO
ELEVATIONS FOR LOCATIONS AND
TYPE) RE: SPEC
GRID
LINE
STANDING SEAM METAL ROOF
RE: SPEC
2X6 T&G DECKING
ICE AND WATER SHIELD CONT. UP WALL 36" MIN.
RE: SPEC
12
2.5"
LAPPED RAFTERS ATTACHED
TO STUDS OR SOLID
BLOCKING RE: STRUCT.
STANDING SEAM METAL ROOF
RE: SPEC
RUN METAL FLASHING UP WALL MIN 6"
EXTEND OVER ROOFING MIN 6"
LAP SELF ADHERING BITUTHANE
FLASHING OVER METAL WALL FLASHING
LAP BLDG PAPER OVER BITUTHANE FLASHING
LAP BLDG PAPER OVER BITUTHANE FLASHING
Scale
Date
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
1 1/2" = 1'-0"
7/14/2014 12:25:57 PM
A6.3
ROOF
DETAILS
2722 CORTINA LANE
7-14-14
BKW
HB
VAIL RIDGE SUBDIVISION, BLOCK B,
LOT 13 , VAIL CO
1 1/2" = 1'-0"
1
ROOF EAVE DETAIL - TYPICAL
1 1/2" = 1'-0"
2
ROOF EAVE DETAIL @ FRONT ENTRY
COLUMN
1 1/2" = 1'-0"
4 ROOF RAKE DETAIL -TYPICAL
1 1/2" = 1'-0"
3
ROOF EAVE DETAIL @ LIVING ROOM
EXPOSED BEAM
REVISION SCHEDULE
# DESCRIPTION DATE
1 1/2" = 1'-0"
5
WALL DETAIL - STONE VENEER @ SHED
ROOF CONNECTION
DRB
APPROVED
8/6/2014 12:00:00 AM