HomeMy WebLinkAboutDRB140277_A003 A1.2 CALCS_1407777600.pdfDate JobNumber 1406 7/14/2014 LOT2, BLOCK4, VAILVILLAGETHIRDFILING 401BEAVERDAMCIRCLERESIDENCES VAIL, COLORADO P.O. BOX3340 Vail, Colorado81658 970-476-2201 FAX476-7491 COPYRIGHT-ALLRIGHTSRESERVED. THISDESIGN, INCLUDINGALLDRAWINGS, HAS BEENPREPAREDFORTHESPECIFICCLIENTAND SITEANDASSUCHARETHEINSTRUMENTSOF PROFESSIONALLYCONTRACTEDSERVICESFOR USESOLELYWITHRESPECTTOTHISPROJECT. THISDESIGNREMAINSTHEINTELLECTUAL PROPERTYOFTHEARCHITECT: SNOWDONANDHOPKINS, ARCHITECTS, P.C. ANYREPRODUCTIONORUSEOFTHESE DRAWINGSFOR DISTRIBUTION, INCLUSION, EVALUATIONORCONSTRUCTIONREGARDING ANYOTHERSITE, ORDESIGN, ISSTRICTLY PROHIBITEDWITHOUTPRIORANDEXPRESSED WRITTENCONSENTANDPERMISSIONOFTHE ARCHITECT. INASMUCHASTHEREMODELINGAND/ORREHABILITATIONOFTHE EXISTINGSTRUCTUREREQUIRESTHATCERTAINASSUMPTIONSBE MADEBYTHEARCHITECTREGARDINGEXISTINGCONDITIONS, AND BECAUSESOMEOFTHESEASSUMPTIONSMAYNOTBEVERIFIABLE WITHOUTTHEOWNER'SEXPENDINGSUBSTANTIALSUMSOF MONEYORDESTROYINGOTHERWISEADEQUATEORSERVICEABLE PORTIONSOFTHESTRUCTURE, THEOWNERAGREES, TOTHE FULLESTEXTENTPERMITTEDBYLAW, TOINDEMNIFYANDHOLD HARMLESSTHEARCHITECT, ITSOFFICERS, DIRECTORS, OWNERS, EMPLOYEES, SUB-CONSULTANTS, SUCCESSORSANDASSIGNS FROMANDAGAINSTANYANDALLCLAIMS, DEMANDS, LOSSES, CAUSESOFACTION, DAMAGES, LIABILITIESORCOSTS, INCLUDING REASONABLEATTORNEYS' FEESANDDEFENSECOSTS, WHICHANY OFTHEFOREGOINGPARTIESMAYINCURARISINGOUTOFORIN ANYWAYCONNECTEDWITHTHISPROJECT, EXCEPTINGONLY THOSEDAMAGES, LIABILITIESORCOSTSATTRIBUTABLESOLELYTO THERECKLESSNESSORWILLFULMISCONDUCTBYTHEARCHITECT . DESIGNREVIEW A 1.2 Proposed GRFA Calculations: See Sheet A1.2 Allowable GRFA 10,000 10,000 0.46 4,600 SF 10,000 - 15,000 5,000 0.38 1,900 SF 15,000-30,000 11,589 0.13 1,507 SF Total Allowable GRFA 8,007 SF Total Allowable Primary GRFA (60%) 4,804 SF Total Allowable Secondary GRFA (40%) 3,203 SF Proposed GRFA Unit A (new and proposed construction) Lower Level (existing) 950 SF 52% of 1,827 actual GRFA Lower Level (new) 129 SF 52% of 248 actual GRFA Total Unit A - Lower Level 1,079 SF 52% of 2,075 actual GRFA Main Level (existing) 1,299 SF Main level (new) 184 SF Total Unit A - Main Level 1,483 SF Total Unit A - Primary 2,562 SF 2,242 SF under 60% allowable GRFA Unit B (all new construction) Lower level 687 SF 52% of 1,321 actual GRFA Main level 1,353 SF Upper level 705 SF Total Unit B - Secondary 2,745 SF 458 SF under 40% allowable GRFA Total combined GRFA 5,307 SF 2,700 SF under total allowable GRFA Unit A Garage 528 SF Unit B Garage 528 SF See sheet A1.3 for Basement wall calculations DRB APPROVED 8/6/2014 12:00:00 AM