HomeMy WebLinkAboutDRB140309_A0-01 - ADA COMPLIANCE_1410358680.pdf60" min.
18"
x 48" min
48" min.
Y
X
54 min
42" min
42" min
24" min.
24" min.
54" min.
42" min.
48" min
24 min. 42" min.
48" min.
48" min. 1/4"
1/4" to 1/2"
6" max. 36" min
12" min 19" min
33" - 36"
12" 42" min.
54" min.
9" min.
27" min.
29" min.
34" min.
6" max.
min. 8"
17" min. depth
40" min.
17" - 19" 9" min.
27" min.
6" max
8" min. 36" max.
30" min.
48" min.
max. 19"
17" min.
30" min
48" min
30" min
48" min
48" min.
30" min.
17" - 19"
24" max
1.5"
1.25" - 1.5"
1.5"
1.25" - 1.5"
60 min.
60 min
36" min.
12" min. 36" min. 12" min.
60" min.
60" min.
12" min 12"min 36" min
12" min
12" min 34" - 38"
34" - 38"
36" min
36" min
36" min
12" min
54" max*
48" max*
27" or
48" max
30" min
20" max
24 max
10"
30 min
48" min
min 30" 6" min
48" max
18"
18"
42" min.
60" min.
56" min.
17" - 19"
< 27"
20" max 24 max
80" min
4" max. higher then 27"
any amount
clear width 27" or below
27" max.
greater then 12" greater then 12"
27" max.
27" 80"
27" max.
12" max.
12" max.
39" - 41" 39" - 41"
18" min.
24" preferred
PULL SIDE PUSH SIDE
PULL SIDE PUSH SIDE
PULL SIDE PUSH SIDE
Y
Y
max
1
2
X
Y
96" min. for VANS
10
1
(ada) - 4.4 Protruding Objects.
4.4.1 General.
Objects projecting from walls (for
example, telephones) with their leading
edges between 27" and 80"(685mm and
2030mm) above the finish floor shall
protrude no more than 4" (100 mm) into
walks, halls, corridors, passageways, or
aisles (see Fig. 8(a)). Objects mounted
with their leading edges at or below 27"
(685mm) above the finish floor may
protrude any amount (see Fig. 8(a) and
(b)). Free-standing objects mounted on
posts or pylons may overhang 12"
(305mm) maximum from 27" to 80"
(685mm to 2030mm) above the ground or
finished floor (see Fig. 8(c) and (d).
Free-standing objects mounted on posts
or pylons may overhang 12" (305mm)
maximum from 27" to 80" (685mm to
2030mm) above the ground.
(ADA) - 4.2.3 Wheelchair Turning Space.
The space required for a wheelchair to
make a 180-degree turn is a clear space
of 60" (1525mm) diameter (see Fig.3(a)) or
a T-shaped space (see Fig. 3(b)).
(ADA) - 4.7.11 Islands.
Any raised islands in crossings shall be cut through
level with the street or have curb ramps at both sides
and a level area at least 48" (1220mm) long between
the curb ramps in the part of the island intersected by
the crossings.
(ADA) - 4.7.7 Detectable Warnings.
A curb ramp shall have a detectable warning complying
with 4.29.2. The detectable warning shall extend the full
width and depth of the curb ramp.
X
(ADA) - 4.18 Urinals.
4.18.1 General.
Accessible urinals shall comply with 4.18.
4.18.2 Height.
Urinals shall be stall-type
or wall-hung with an elongated rim at a
maximum of 17" (430mm) above the finish
floor.
4.18.3 Clear Floor Space.
A clear floor space 30" x 48" (760mm x
1220mm) shall be provided in front of
urinals to allow forward approach. This
clear space shall adjoin or overlap an
accessible route and shall comply with
4.2.4. Urinal shields that do not extend
beyond the front edge of the urinal rim
may be provided with 29" (735mm)
clearance between them.
(ADA) - 4.22 Toilet Rooms.
4.22.3 Clear Floor Space.
The accessible fixtures and controls
required in 4.22.4, 4.22.5, 4.22.6, and
4.22.7 shall be on an accessible route.
An unobstructed turning space complying
with 4.2.3 shall be provided within an
accessible toilet room. The clear floor
space at fixtures and controls, the
accessible route, and the turning
space may overlap.
ACCESSIBLE ROUTE
LANDING
LEVEL
LANDING
LEVEL
SLOPE (INCHES) (FEET )
10 1
36" min
typ
ELEVATION
wall
curb
min
2" curb
SECTION
vertical ground rail below
27" or
width
any
plans
see
below
max
elevation plan
plans
elevation
TOILET
T.P.
LEVER VALVE
PROTECTED PIPING
clearance
toe
MIRROR
space
floor
clear
(a) 60" Diameter Space (b) T-Shaped Space for 180 Degree Turns
plan elevation
cane range
elevation
PROTRUDING OBJECTS
FIG. 8
36" min
60" min
21' - 0" min
96" min
HORIZONTAL PROJECTION OR RUN RISE
WALK
STREET
MAX RISE MAX. HORIZ. PROJECTION
20'- 0" min
5'- 0" min
X
Y
CL
(a) back wall (b) side wall
plan
(ADA) - 4.19.6 Mirrors.
Mirrors shall be mounted with bottom edge
of the reflecting surface no higher than 40"
(1015mm) above the finish floor (see Fig. 31).
Reference Site Plan (sheet A1.00) for Type
A (Accessible Unit) locations.
FIG. 9 (ADA)
FIG. 502.2 & 502.3 (ANSI)
DIMENSION OF PARKING SPACES
FIG. 10 (ADA)
FIG. 503.3 (ANSI)
ACCESS AISLE AT PASSENGER
LOADING ZONES
ADJOINING SLOPE SHALL
NOT EXCEED 1: 20
SLOPE = Y : X
WHERE X IS A
LEVEL PLANE
FIG. 11 (ADA)
MEASUREMENT OF CURB RAMP SLOPE
1:12 TO <1:16 30
30 1:16 TO <1:20 30
40
FIG. 16 (ADA)
COMPONENTS OF A SINGLE RAMP RUN
AND SAMPLE RAMP DIMENSIONS
If X is less than 48"
then the slope of
the flared side
shall not exceed
1:12
flared side
(a)
flared
side
planting or
other
non-walking
surface
(b)
returned
curb
FIG. 13 (ADA)
BUILT - UP CURB RAMP
FIG. 12 (ADA)
SIDES OF CURB RAMPS
rolling with
extended platform
FIG. 17 (ADA)
EXAMPLES OF EDGE PROTECTION
AND HANDRAIL EXTENSIONS
FIG. 39 (a) (ADA)
HANDRAIL
opt.
post
and
base
(a) Side Reach Possible
(b) Forward Reach Required
* Height to heighest
operable parts which are
essential to basic
operation of telephone.
FIG. 44 (ADA)
MOUNTING HEIGHTS AND CLEARANCES
FOR TELEPHONES
(a)
Front Approach - Swinging
Doors
NOTE : X = 12" if
door has both
closer and latch
NOTE : Y = 48" min.
if door has both
closer and latch
NOTE : X = 36" min. If Y = 60"
X = 42" min. If Y = 54"
(b)
Hinge Side Approach - Swinging
Doors
NOTE : Y = 54" min.
if door has closer.
NOTE : Y = 48" min.
if door has closer.
(c)
Latch Side Approach - Swinging
Doors
FIG. 25 (ADA)
MANEUVERING CLEARANCES AT DOORS
NOTE : All doors in alcoves shall comply with
the clearances for front approaches
(d)
Front Approach - Sliding
Doors and Folding Doors
(e)
Slide Side Approach - Sliding
Doors and Folding Doors
(f)
Latch Side Approach - Sliding
Doors and Folding Doors
FIG. 26 (ADA)
TWO HINGED DOORS IN SERIES
FIG. 7 (c & d)
(ADA) CHANGES IN
LEVEL
FIG. 29 (ADA)
GRAB BARS AT WATER CLOSETS
(ANSI A117.1-2003 FIG. 604.5.1 &
604.5.2)
knee clearance
FIG. 31 (ADA)
LAVATORIES CLEARANCE
FIG. 32 (ADA)
CLEAR FLOOR SPACE AT LAVATORIES
clear floor space
FIG. 28 (ADA)
CLEAR FLOOR SPACE AT WATER CLOSETS
equipment
permitted in
shaded area
(a)
Spout Height
and Knee
Clearance
(b)
Clear Floor
Space
FIG. 39 (e) (ADA)
GRAB BAR
(c)
Free - Standing
Fountain or
Cooler
(d)
Built - in Fountain
or Cooler
FIG. 27 (ADA)
DRINKING FOUNTAINS AND WATER COOLERS
not to
exceed
fountain
depth
FIG. 3 (ADA)
WHEELCHAIR TURNING SPACE
Fig. 8 (a)
Walking Parallel to a Wall
Fig. 8 (b)
Walking Perpendicular to a
Wall
Fig. 8 (c)
Free--Standing Overhanging
Object
protect
shaded area
from cross -
traffic
Fig. 8(c-1)
OverHead
Hazards
Fig. 8(d)
Objects Mounted on posts or
pylons
cane hits
post or
pylon
before
person hits
object
cane range this overhang can be
greater than 12" because
no one can approach the
object from this direction
Codes & Regulations Referenced:
ADA (American Disabilities Act 07-01-99 Edition)
FHA (Fair Housing Act 04-01-99 Edition)
FHADM (FHA Design Manual Revised April 1998 Edition)
ANSI (ICC/ANSI A117.1-2003)
Note: Only a portion of applicable codes & regulations
shown, see each applicable code manual for a
complete list of all codes
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
182 WEST MEADOW DRIVE
VAIL, CO 81657
A0.01
ADA
COMPLIANCE
PIETRINI RESIDENCE
Project Number - 1428
08/18/14
DRB SUBMITTAL
DRB
APPROVED
8/20/2014 12:00:00 AM