HomeMy WebLinkAboutDRB140314_Leever Residence_A1-0 - COVER SHEET_1410964020.pdfRADON MITIGATION SYSTEM PROVIDE DESIGN-BUILD ENGINEERING AND CONSTRUCTION OF A PASSIVE RADON MITIGATION SYSTEM FOR THE PROJECT TO WHICH AN INLINE FAN COULD BE ADDED LATER IF REQUIRED PER THE FOLLOWING CRITERIA AND AS REQUIRED TO MAINTAIN RADON LEVELS AT THE MECHANICAL ROOM, LOWER LEVEL AND HOUSE BELOW EPA AND OTHER GOVERNMENT STANDARDS. THE RADON MITIGATION SUBCONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH THE VAPOR BARRIER INSTALLATION AND THE ELECTRICIAN FOR AN ELECTRICAL JUNCTION BOXES AT THE LOCATIONS DETERMINED BY THE RADON MITIGATION SUBCONTRACTOR FOR THE POTENTIAL FUTURE FANS. AT A MINIMUM, THE FOLLOWING SYSTEMS/SERVICES WILL BE PROVIDED AS PART OF THE BASE BID BY THE RADON MITIGATION SUB CONTRACTOR. - SEALING OF THE LOWER LEVEL CONCRETE SLAB TO THE FOUNDATION WALLS - SEALING OF ALL PLUMBING AND OTHER PENETRATIONS THROUGH THE CONCRETE SLABS AND THROUGH THE BELOW GRADE PORTIONS OF THE FOUNDATION WALL - LOCATIONS & INSTALLATION OF PIPES, PORTS, AND OPENINGS IN THE SLAB FOR SLAB DEPRESSURIZATION SYSTEM. - PROVIDE PASSIVE VENT PIPE SYSTEM WHICH RUNS FROM THE SLAB PENETRATION LOCATIONS(S) TO THE OUTSIDE IN ACCORDANCE WITH THE EPA STANDARDS. THE VENTS SHALL BE RUN WITHIN THE INTERIOR OR EXTERIOR WALLS TO A LOCATION(S) HIGH ON THE ROOF. COORDINATE VENT LOCATIONS WITH ARCHITECT AND/OR OWNER - PROVIDE POWER ADJACENT TO SLAB VENT PENETRATIONS FOR POTENTIAL FUTURE INLINE FAN LOCATION INCLUDING ALL REQUIRED ROUGH IN WIRING AND JUNCTION BOXES, IN THE EVENT THAT A FAN IS REQUIRED TO BE INSTALLED - PROVIDE PROVISIONS FOR A SYSTEM FAILURE INDICATOR, INCLUDING ALL REQUIRED ROUGH-IN WIRING, AND JUNCTION BOXES, IN THE EVENT THAT A FAN IS REQUIRED TO BE INSTALLED. - PERFORM RADON TESTING AFTER THE HOME/PASSIVE SYSTEM IS COMPLETE TO DETERMINE IF THE HOME PASSES OR IF AN ACTIVE SYSTEM IS REQUIRED IN ORDER TO MAINTAIN RADON BELOW EPA AND OTHER GOVERNMENTAL STANDARDS. - IF AN ACTIVE SYSTEM IS REQUIRED, PERFORM FOLLOW UP RADON TESTING AFTER THE SYSTEM IS COMPLETE TO DETERMINE IF RADON HAS BEEN MITIGATED - PROVIDE AND INLINE FAN IF ACTIVE SYSTEM IS REQUIRED. PROVIDE OTHER EQUIPMENT AND SYSTEM AS REQUIRED TO PROVIDE A FUNCTIONAL RADON MITIGATION SYSTEM FOR THE UNITS. CONTRACTOR TO COORDINATE INSTALLATION OF THE 10 MIL VAPOR BARRIER UNDER THE SLAB INCUDING THE SEALING OF ALL JOINTS, ALL PLUMBING OR MECHANICAL OR OTHER PENETRATIONS AND THE SEALING AND MECHANICAL FASTENING OF THE VAPOR BARRIER TO THE EXTERIOR CONCRETE FOUNDATION WALLS. RE: OUTLINE SPEC FOR MORE DETAILS Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 4 1 A5.1 A 3.2 PROJECT DIRECTORY 1 2 3 4 A9.1 A6.1 1 A6.1 1 100 LIVING 1 A4.1 SIM. SYMBOL LEGEND ABBREVIATIONS MATERIAL LEGEND DRAWING LIST: PROJECT INFORMATION ARCHITECT BERGLUND ARCHITECTS, LLC P.O. Box 2378 210 Edwards Village Blvd Suite A103 Edwards, CO 81632 Phone: (970) 926-4301 Fax: (970) 926-4364 hans@berglundarchitects.com 100 A BUILDING SECTION NO. SECTION CUT SHEET NO. DETAIL NO. DETAIL CUT SHEET NO. ROOM NUMBER EXTERIOR ELEVATION DOOR MARK DETAIL CUT REFERENCE GRID LINE SPOT ELEVATION DRAWING REVISION INTERIOR ELEVATION WINDOW MARK Galvanized Laminated Wood Beam General Contractor Hardware Gypsum Wallboard Grade Gypsum RW RO SEW SECT SAN SHLV Cpt Carpet Ceramic CER SIM SHT W/ Reinforce (d) REINF FD Floor Drain With (comb. form) Required Round Head Sheet Metal Screw GA FDN FTG Room RM RHSM REQD Gauge Foundation Footing WD W/O Wood Without and Air Conditioning Heating, Ventilating, Lavatory Manufacturer Laminate Inside Diameter Miscellaneous Mechanical Not In Contract Medicine Cabinet Masonry Opening Horizontal On Center Not to Scale Oriented Strand Board Opposite Outside Diameter Property Plywood Perforated (d) Prefinished Sheet Metal Penny (nails, etc.) Refrigerator Radius or Riser Not Applicable AAD ADD AGG ADJ AOR BM ARCH ALT BD BS BET BRG AFF CL BLDG CAB CLOS CMU CJ CONC COL DP DIA DET CONT BO DR DN DW EL EA DRWG DS EQ EJ EXIST EXT FE CABT FOC FOS FP FL FIN DIM GC GALV Glass GLB GR GL Head HD HDW GWB Highway Height HWY HT HVAC GYP Addendum Attic Access Door Aggregate Adjacent Area of Refuge Alternate Beam Architectural Board Between Both Sides Bearing Above Finished Floor Interior Joint JT INT ID MO MFG LAV LAM Maximum Material MAX MC MTL Minimum NIC MISC MIN MECH Cabinet Building Centerline Closet Concrete Column Construction Joint Detail Diameter Damproofing Continuous Concrete Masonry Unit HOR Bottom Of Opening OPG OC NTS d OD OSB OPP Plate PL PFSM PLWD PERF Project Product PROD PROP PROJ Drain Dishwasher Down Elevation Each Drawing Downspout Equal Existing Exterior Expansion Joint Face Of Concrete Face Of Stud Fire Extinguisher Cabinet Refer REF REFR Floor Fireproof R Finish NA Dimension Tongue and Groove Toilet Paper Holder Sound- Transmission Class Vinyl Asbestos Tile United States Gage Unless Noted Otherwise Uniform Building Code SL SQ SPEC STC SM SUB STRUCT STL TV TEL SUSP SUPPL IE THK TEMP TO T&B T&G TPH STD Roof Window Sewer Sanitary Section Rough Opening Sliding Shelves Similar Square Specification Sheet Metal Sheet Steel Substitute Structure (al) Television Telephone Suspend (ed) Supplement (al) That Is Thick Tempered Top Of Top and Bottom Standard UG TYP TS USG UBC UNFIN U.N.O. VENT VIF VERT VAR VAT WC V WT WIN WP Typical Underground Tube Steel Unfinished Variable Vertical Ventilate Verify In Field Voltage Water Closet Weight Window Waterproof T Tread FINISHED WOOD ROUGH FRAMING OR ROUGH SAWN TRIM WOOD BLOCKING CONCRETE STONE TILE GLAZING FRAME WALL CONCRETE MASONRY PARTICLE BD. OR GLU-LAM WOOD WOOD FIBER BD. RIGID INSULATION CARPET ACOUSTICAL CEILING STEEL PLYWOOD SHEET METAL BATT INSULATION GYP. WALL BOARD/ STUCCO/ PLASTER ALUMINUM OR SECTION PLAN SECTION PLAN ROCK/ SOIL/ COMPACTED FILL SAND NON-COMPACTED FILL STRUCTURAL ENGINEER LANDSCAPE ARCHITECT CLIENTS Issue Date: ELEV. 100'-0" T.O. PWD. SITE ELEV. = 116'-0" Power Actuated Fastened PAF CODE INFORMATION CONTRACTOR Harold Leever II & Emily Leever 1397 Vail Valley Drive, Vail, CO 81657 Phone: (720) 878-3961 E-mail: SLeever@macdermid.com VICINITY MAP SURVEYOR Eagle Valley Surveying, Inc. Contact: Michael J. Post 41199 Highway 6 & 24, Eagle-Vail - P.O. Box 1230 Edwards, CO 81632 Phone: (970) 949-1406 5087 Main Gore Dr N MECHANICAL ENGINEER CIVIL ENGINEER SOILS ENGINEER HP Geotech Contact: David A. Young 5020 County Road 154 Glenwood Springs, CO 81601 Phone: (970) 945-7988 Fax: (970) 945-8454 A. THE CONTRACT DOCUMENTS CONSIST OF ARCHITECTURAL AND STRUCTURAL DRAWINGS, THE AGREEMENT, THE GENERAL NOTES AND THE SPECIFICATIONS. ANY WORK SHOWN IN ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY COVERED IN ALL. ANY DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY. B. CONTRACTOR WILL ASSUME RESPONSIBILITY OF ITEMS REQUIRING COORDINATION AND RESOLUTION DURING THE CONSTRUCTION PROCESS C. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES, AND SHALL BE PREFORMED TO THE HIGHEST STANDARDS OF CRAFTSMANSHIP BY JOURNEYMAN OF THE APPROPRIATE TRADES. D. THESE DOCUMENTS ARE INTENDED TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE ALL WORK DESCRIBED HEREIN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTION ACCORDING TO THE INTENTIONS OF THESE DOCUMENTS. IT IS THE RESPONSIBILITY OF THE ARCHITECT TO PROVIDE DETAILS AND/OR DIRECTIONS REGARDING DESIGN INTENT WHERE IT IS ALTERED BY EXISTING CONDITIONS OR WHERE NEGLECTED IN THE DOCUMENTS. E. ANY MATERIALS PROPOSED FOR SUBSTITUTION OF THOSE SPECIFIED OR CALLED OUT BY TRADE NAME IN THESE DOCUMENTS SHALL BE PRESENTED TO THE ARCHITECT FOR REVIEW. THE CONTRACTOR SHALL SUBMIT SAMPLES WHEN REQUIRED BY THE ARCHITECT. AND ALL SUCH SAMPLES SHALL BE REVIEWED BY THE ARCHITECT BEFORE THE WORK IS PERFORMED. WORK MUST CONFORM TO THE REVIEWED SAMPLES. ANY WORK WHICH DOES NOT CONFORM SHALL BE REMOVED AND REPLACED WITH WORK WHICH CONFORMS AT THE CONTRACTOR'S EXPENSE. SUBCONTRACTORS SHALL SUBMIT REQUESTS AND SAMPLES FOR REVIEW THROUGH THE GENERAL CONTRACTOR WHEN WORK IS LET THROUGH HIM OR HER. REQUIRED VERIFICATIONS AND SUBMITTALS TO BE MADE IN ADEQUATE TIME AS TO NOT DELAY PROGRESS. F. SHOP DRAWINGS MUST BE THOROUGHLY REVIEWED BY CONTRACTOR PRIOR TO SUBMITTING TO ARCHITECT TO MAKE SURE THEY ARE ACCURATE AND MEET DESIGN INTENT. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR HIS OR HER REVIEW WHERE CALLED FOR ANYWHERE IN THESE DOCUMENTS. REVIEW SHALL BE MADE BY THE ARCHITECT BEFORE WORK IS BEGUN, AND WORK SHALL CONFORM TO THE REVIEWED SHOP DRAWINGS, SUBJECT TO REPLACEMENT AS REQUIRED IN PARAGRAPH E ABOVE. ARCHITECT WILL TRY TO IDENTIFY ANY DISCREPENCIES IN SHOP DRAWINGS, BUT CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR SHOP DRAWING ACCURACY. G. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR WHEN THERE IS NEED OF INSPECTION AS REQUIRED BY THE 2009 INTERNATIONAL RESIDENTIAL CODE OR ANY LOCAL CODE OR ORDINANCE. H. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL AND STATE O.S.H.A. REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS DELIVERED COMPLETED TO THE OWNER. I. ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALED DIMENSIONS. DIMENSIONS NOTED WITH "N.T.S." DENOTES NOT TO SCALE. J. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS, CEILINGS, AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. K. CONTRACTOR TO COORDINATE NEW CONSTRUCTION W/EXISTING CONDITIONS AND NOTIFY ARCHITECT AND STRUCTURAL ENGINEER ABOUT DISCREPENCIES OF DRAWINGS OF EXISTING HOUSE AND ASSUMPTIONS. GENERAL NOTES KRM Consultants Inc. Contact: Tim Hennum P.O. Box 4572 Vail, CO 81658 Office: (970) 949-9391 Fax: (970 949-0839 krm@krmconsultants.com Neils Lunceford, Inc. Contact: Dan Skinner P.O. Box 2130 740 Blue River Parkway Silverthorne, CO 80498 Office: (970) 468-0340 Fax: (970 468-6865 danskinner@neilslunceford. com 1/4" = 1'-0" 7/28/2014 12:08:37 PM A1.0 COVER SHEET AC HB, SLJ LEEVER RESIDENCE 7-28-14 5087 Main Gore Drive North, Vail CO Subdivision: Bighorn 5th Addition Block: 1 Lot: 2 FINAL DRB SUBMITTAL LEEVER RESIDENCE 5087 Main Gore Drive North, Vail CO Subdivision: Bighorn 5th Addition Block: 1 Lot: 2 7-28-14 FINAL DRB SUBMITTAL A1.0 COVER SHEET SURVEY LANDSCAPE DRAWINGS L1 PHASE 1 LANDSCAPE PLAN L2 PHASE 1 LANDSCAPE PLAN DETAILS ARCHITECTURAL DRAWINGS A2.0 SITE PLAN A2.1 LANDSPACE CALCS A2.2 CONSTRUCTION MANAGEMENT PLAN A2.3 AREA CALCS A3.1 MAIN LEVEL FLOOR PLAN A3.2 UPPER LEVEL FLOOR PLAN A3.3 ROOF PLAN A4.1 ELEVATIONS A4.2 ELEVATIONS A4.3 GARAGE ELEVATIONS A4.4 PARTIAL ELEVATIONS A4.5 3D VIEWS A5.1 BUILDING SECTIONS A5.2 BUILDING SECTIONS A5.3 BUILDING SECTIONS A6.1 FOUNDATION DETAILS A6.2 FOUNDATION DETAILS A6.3 WALL DETAILS A6.4 ROOF DETAILS A6.5 DETAILS A8.0 WINDOW & DOOR SCHEDULE A8.1 WINDOW & DOOR DETAILS A10.2 MAIN LEVEL RCP A10.3 UPPER LEVEL RCP STRUCTURAL DRAWINGS MECHANICAL DRAWINGS CODE: 2012 IRC, 2012 IECC OCCUPANCY TYPE: SINGLE FAMILY HOME ENERGY CONSERVATION: THE BUILDING COMPLIES WITH THE ENERGY CONSERVATION REQUIREMENT FROM CHAPTER 4 OF THE 2012 INTERNATIONAL ENERGY CODE PER ZONE 6B ADOPTED BY THE TOWN OF VAIL, AS FOLLOWS: The following is a summary for the climate zone 6B of Table 402.1.1 requirements of the IEC (including the 10-1-9: AMENDMENTS TO ENERGY CONSERVATION CODE as adopted by The Town of Vail :, and an outline of the proposed R values of the assemblies of the building which are defined in the Construction Document Drawings and Specifications: Maximum Glazing U-Factor of .30 for new single family dwelling units per Town of Vail amendments The Jeld-Wen windows double glazed w/ low E (EC) 366 @ surface 2 and i89 @ surface 4 meets this requirement - average U-Factor .30 Ceilings & Roofs Insulation - Requirement of R-49 which is reduced to R-38 per 402.2.1 since the construction techniques provide a full R-38 insulation value over the wall top plate. @ Typical Roof Condition - The design provides a full R-38 insulation value over the wall top plate as follows: Provide R62.4 at roof Cavities with 5/8" plywood over 14” TJIs: Provide R62.4 with 4” minimum of 2# closed cell spray foam insulation with an R value of 6.6 per inch equaling R26.4 and 10” of blown in cellulose insulation with R3.6 per inch equaling R36. Crawlspace Walls Insulation - Requires R-15 of continuous insulation or R-19 cavity insulation : Provide R-15 with 3" exterior insulation/drainagemedium with R5 per inch over the typical 8" concrete wall. Exterior Walls Insulation - Requires R-20: Exterior walls with 5.5” cavity: Provide R25.8 with 2” minimum of spray foam insulation @ inside of sheathing with an R value of 6.6 per inch equaling R13.2 and 3.5” of blown in cellulose insulation with R3.6 per inch equaling R12.6 or approved equal. Floor Insulation - Requires R-30: The building has been designed with a conditioned crawlspace at the main house and slab on grade at garage. @ Floor over Outdoor Room Master Bedroom Overhang) - Provide 2" min. spray foam insulation @ underside of floor sheathing w/ an R-Value of 6.6 per inch equaling 13.2 and 12" of blown in cellulose insulation w/ R-3.6 per inch equaling R-43.2 providing a total insulation value of R-56.4. @ Floor over Crawlspace - Provide 12" min of blown in cellulose insulation w/ R-3.6 per inch equaling R-43.2. @Garage Slab - Requires R-15 for 4' horizontally under slab (since the slab is heated). Provide R15 with R5 ridged insulation under the slab and and R-10 continuous @ exterior of foundation. Provide full cavity blown in cellulose sound insulation at all interior walls and at all floor assemblies. ADDITIONAL REQUIREMENTS PER TOWN OF VAIL CODE AMENDMENTS: ROOF COVERING: Meets Section 1505.6 of the Town of Vail Code- The standing seam metal roofing will be installed to meet the required Class A roof or Class A roof assembly. FIRE SPRINKLER SYSTEM AND ALARM: Design Build - Building is to be equipped throughout with an automatic sprinkler system installed in accordance with NFPA 13 and the Town of Vail. A monitored fire alarm system will also be provided in compliance with the Town of Vail codes and regulations. PLUMBING: Design Build - See Architectural Drawings for fixture locations only. MECHANICAL: Design Build ELECTRICAL: Design Build Leever Residence 5087 Main Gore Drive North, Subdivision: Bighorn 5th Addition Block: 1 Lot: 2 Zone District: Single Family Residential ( SFR ) Lot is .613 acres, equal to 26,702 SF Allowable GRFA .46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.4 equals 4,000 SF .13 SF per 1 SF of site area > 10,000 SF of site area 16,702 x 0.13 equals 2,171 SF _______________________________________________________________________ Total Allowed Gross Residential Floor Area (GRFA) for entire lot 6,171 SF Allowable site coverage is 20% of lot 5,340 SF Square Footage Summary Habitable SF GRFA SF Main Level 2,456 SF 2,456 SF Upper Level 2,306 SF 2,306 SF Subtotal Finished 4,762 SF Bonus Room (unfinished) 1,026 SF 1,026 SF Garage (additional area beyond allowance) 336 SF 336 SF ____________________________________________________________________ Total 6,124 SF 6,124 SF Provided SF Allowed SF Garage 936 SF 600 SF Site Coverage 3,827 SF 5,340 SF GRFA 6,124 SF 6,171 SF Site Coverage Allowable site coverage is 20% of lot which equals 5,340 SF. 3,827 SF is provided. See Sheet A2.1 for landscape coverage information. Setbacks 20' from front 15' from sides 15' from rear Patio can extend to 1/2 the distance of the setback Decks can encroach set back 5' Roof or architectural projections can encroach 4' Height Sloping roof not to exceed 33' Garage Allow 600 sq. ft. per unit. 936 SF is provided. Parking Required per Chapter 10 If dwelling is more than 5,500 GRFA 5 spaces are required. 3 covered 9' x 18' (in garage) and 2 uncovered 9' x 19' parking spaces are provided. No. Revision Description Revision Date DRB APPROVED 8/21/2014 12:00:00 AM 6,168