HomeMy WebLinkAboutDRB140314_Leever Residence_A1-0 - COVER SHEET_1410964020.pdfRADON MITIGATION SYSTEM
PROVIDE DESIGN-BUILD ENGINEERING AND CONSTRUCTION OF A PASSIVE RADON MITIGATION SYSTEM FOR THE PROJECT TO WHICH AN INLINE FAN COULD BE ADDED LATER IF REQUIRED PER THE
FOLLOWING CRITERIA AND AS REQUIRED TO MAINTAIN RADON LEVELS AT THE MECHANICAL ROOM, LOWER LEVEL AND HOUSE BELOW EPA AND OTHER GOVERNMENT STANDARDS. THE RADON
MITIGATION SUBCONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH THE VAPOR BARRIER INSTALLATION AND THE ELECTRICIAN FOR AN ELECTRICAL JUNCTION BOXES AT
THE LOCATIONS DETERMINED BY THE RADON MITIGATION SUBCONTRACTOR FOR THE POTENTIAL FUTURE FANS.
AT A MINIMUM, THE FOLLOWING SYSTEMS/SERVICES WILL BE PROVIDED AS PART OF THE BASE BID BY THE RADON MITIGATION SUB CONTRACTOR.
- SEALING OF THE LOWER LEVEL CONCRETE SLAB TO THE FOUNDATION WALLS
- SEALING OF ALL PLUMBING AND OTHER PENETRATIONS THROUGH THE CONCRETE SLABS AND THROUGH THE BELOW GRADE PORTIONS OF THE FOUNDATION WALL
- LOCATIONS & INSTALLATION OF PIPES, PORTS, AND OPENINGS IN THE SLAB FOR SLAB DEPRESSURIZATION SYSTEM.
- PROVIDE PASSIVE VENT PIPE SYSTEM WHICH RUNS FROM THE SLAB PENETRATION LOCATIONS(S) TO THE OUTSIDE IN ACCORDANCE WITH THE EPA STANDARDS. THE VENTS SHALL BE RUN WITHIN
THE INTERIOR OR EXTERIOR WALLS TO A LOCATION(S) HIGH ON THE ROOF. COORDINATE VENT LOCATIONS WITH ARCHITECT AND/OR OWNER
- PROVIDE POWER ADJACENT TO SLAB VENT PENETRATIONS FOR POTENTIAL FUTURE INLINE FAN LOCATION INCLUDING ALL REQUIRED ROUGH IN WIRING AND JUNCTION BOXES, IN THE EVENT THAT
A FAN IS REQUIRED TO BE INSTALLED
- PROVIDE PROVISIONS FOR A SYSTEM FAILURE INDICATOR, INCLUDING ALL REQUIRED ROUGH-IN WIRING, AND JUNCTION BOXES, IN THE EVENT THAT A FAN IS REQUIRED TO BE INSTALLED.
- PERFORM RADON TESTING AFTER THE HOME/PASSIVE SYSTEM IS COMPLETE TO DETERMINE IF THE HOME PASSES OR IF AN ACTIVE SYSTEM IS REQUIRED IN ORDER TO MAINTAIN RADON BELOW
EPA AND OTHER GOVERNMENTAL STANDARDS.
- IF AN ACTIVE SYSTEM IS REQUIRED, PERFORM FOLLOW UP RADON TESTING AFTER THE SYSTEM IS COMPLETE TO DETERMINE IF RADON HAS BEEN MITIGATED
- PROVIDE AND INLINE FAN IF ACTIVE SYSTEM IS REQUIRED. PROVIDE OTHER EQUIPMENT AND SYSTEM AS REQUIRED TO PROVIDE A FUNCTIONAL RADON MITIGATION SYSTEM FOR THE UNITS.
CONTRACTOR TO COORDINATE INSTALLATION OF THE 10 MIL VAPOR BARRIER UNDER THE SLAB INCUDING THE SEALING OF ALL JOINTS, ALL PLUMBING OR MECHANICAL OR OTHER PENETRATIONS
AND THE SEALING AND MECHANICAL FASTENING OF THE VAPOR BARRIER TO THE EXTERIOR CONCRETE FOUNDATION WALLS.
RE: OUTLINE SPEC FOR MORE DETAILS
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
4
1
A5.1
A
3.2
PROJECT DIRECTORY
1
2
3
4
A9.1
A6.1
1
A6.1
1
100
LIVING
1
A4.1
SIM.
SYMBOL LEGEND
ABBREVIATIONS
MATERIAL LEGEND
DRAWING LIST:
PROJECT INFORMATION
ARCHITECT
BERGLUND ARCHITECTS, LLC
P.O. Box 2378
210 Edwards Village Blvd
Suite A103
Edwards, CO 81632
Phone: (970) 926-4301
Fax: (970) 926-4364
hans@berglundarchitects.com
100
A
BUILDING
SECTION NO.
SECTION CUT
SHEET NO.
DETAIL NO.
DETAIL CUT
SHEET NO.
ROOM NUMBER
EXTERIOR ELEVATION
DOOR MARK
DETAIL CUT
REFERENCE GRID LINE
SPOT ELEVATION
DRAWING REVISION
INTERIOR ELEVATION
WINDOW MARK
Galvanized
Laminated Wood Beam
General Contractor
Hardware
Gypsum Wallboard
Grade
Gypsum
RW
RO
SEW
SECT
SAN
SHLV
Cpt Carpet
Ceramic
CER
SIM
SHT
W/
Reinforce (d)
REINF
FD Floor Drain
With (comb. form)
Required
Round Head Sheet Metal Screw
GA
FDN
FTG
Room
RM
RHSM
REQD
Gauge
Foundation
Footing
WD
W/O
Wood
Without
and Air Conditioning
Heating, Ventilating,
Lavatory
Manufacturer
Laminate
Inside Diameter
Miscellaneous
Mechanical
Not In Contract
Medicine Cabinet
Masonry Opening
Horizontal
On Center
Not to Scale
Oriented Strand Board
Opposite
Outside Diameter
Property
Plywood
Perforated (d)
Prefinished Sheet Metal
Penny (nails, etc.)
Refrigerator
Radius or Riser
Not Applicable
AAD
ADD
AGG
ADJ
AOR
BM
ARCH
ALT
BD
BS
BET
BRG
AFF
CL
BLDG
CAB
CLOS
CMU
CJ
CONC
COL
DP
DIA
DET
CONT
BO
DR
DN
DW
EL
EA
DRWG
DS
EQ
EJ
EXIST
EXT
FE CABT
FOC
FOS
FP
FL
FIN
DIM
GC
GALV
Glass
GLB
GR
GL
Head
HD
HDW
GWB
Highway
Height
HWY
HT
HVAC
GYP
Addendum
Attic Access Door
Aggregate
Adjacent
Area of Refuge
Alternate
Beam
Architectural
Board
Between
Both Sides
Bearing
Above Finished Floor
Interior
Joint
JT
INT
ID
MO
MFG
LAV
LAM
Maximum
Material
MAX
MC
MTL
Minimum
NIC
MISC
MIN
MECH
Cabinet
Building
Centerline
Closet
Concrete
Column
Construction Joint
Detail
Diameter
Damproofing
Continuous
Concrete Masonry Unit
HOR
Bottom Of
Opening
OPG
OC
NTS
d
OD
OSB
OPP
Plate
PL
PFSM
PLWD
PERF
Project
Product
PROD
PROP
PROJ
Drain
Dishwasher
Down
Elevation
Each
Drawing
Downspout
Equal
Existing
Exterior
Expansion Joint
Face Of Concrete
Face Of Stud
Fire Extinguisher Cabinet
Refer
REF
REFR
Floor
Fireproof R
Finish
NA
Dimension
Tongue and Groove
Toilet Paper Holder
Sound- Transmission Class
Vinyl Asbestos Tile
United States Gage
Unless Noted Otherwise
Uniform Building Code
SL
SQ
SPEC
STC
SM
SUB
STRUCT
STL
TV
TEL
SUSP
SUPPL
IE
THK
TEMP
TO
T&B
T&G
TPH
STD
Roof Window
Sewer
Sanitary
Section
Rough Opening
Sliding
Shelves
Similar
Square
Specification
Sheet Metal
Sheet
Steel
Substitute
Structure (al)
Television
Telephone
Suspend (ed)
Supplement (al)
That Is
Thick
Tempered
Top Of
Top and Bottom
Standard
UG
TYP
TS
USG
UBC
UNFIN
U.N.O.
VENT
VIF
VERT
VAR
VAT
WC
V
WT
WIN
WP
Typical
Underground
Tube Steel
Unfinished
Variable
Vertical
Ventilate
Verify In Field
Voltage
Water Closet
Weight
Window
Waterproof
T Tread
FINISHED WOOD
ROUGH FRAMING OR
ROUGH SAWN TRIM
WOOD BLOCKING
CONCRETE
STONE
TILE
GLAZING
FRAME WALL
CONCRETE MASONRY
PARTICLE BD. OR
GLU-LAM WOOD
WOOD FIBER BD.
RIGID INSULATION
CARPET
ACOUSTICAL CEILING
STEEL
PLYWOOD
SHEET METAL
BATT INSULATION
GYP. WALL BOARD/
STUCCO/ PLASTER
ALUMINUM OR
SECTION PLAN
SECTION PLAN
ROCK/
SOIL/ COMPACTED FILL
SAND
NON-COMPACTED FILL
STRUCTURAL
ENGINEER
LANDSCAPE
ARCHITECT
CLIENTS
Issue Date:
ELEV. 100'-0"
T.O. PWD.
SITE ELEV. = 116'-0"
Power Actuated Fastened
PAF
CODE INFORMATION
CONTRACTOR
Harold Leever II & Emily Leever
1397 Vail Valley Drive,
Vail, CO 81657
Phone: (720) 878-3961
E-mail: SLeever@macdermid.com
VICINITY MAP
SURVEYOR
Eagle Valley Surveying, Inc.
Contact: Michael J. Post
41199 Highway 6 & 24,
Eagle-Vail - P.O. Box 1230
Edwards, CO 81632
Phone: (970) 949-1406
5087 Main Gore Dr N
MECHANICAL
ENGINEER
CIVIL ENGINEER SOILS ENGINEER
HP Geotech
Contact: David A. Young
5020 County Road 154
Glenwood Springs, CO
81601
Phone: (970) 945-7988
Fax: (970) 945-8454
A. THE CONTRACT DOCUMENTS CONSIST OF ARCHITECTURAL AND STRUCTURAL DRAWINGS, THE AGREEMENT, THE GENERAL
NOTES AND THE SPECIFICATIONS. ANY WORK SHOWN IN ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY
COVERED IN ALL. ANY DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY.
B. CONTRACTOR WILL ASSUME RESPONSIBILITY OF ITEMS REQUIRING COORDINATION AND RESOLUTION DURING THE
CONSTRUCTION PROCESS
C. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES, AND SHALL BE PREFORMED TO THE
HIGHEST STANDARDS OF CRAFTSMANSHIP BY JOURNEYMAN OF THE APPROPRIATE TRADES.
D. THESE DOCUMENTS ARE INTENDED TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE
ALL WORK DESCRIBED HEREIN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT
ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTION ACCORDING TO THE INTENTIONS OF THESE DOCUMENTS. IT IS THE
RESPONSIBILITY OF THE ARCHITECT TO PROVIDE DETAILS AND/OR DIRECTIONS REGARDING DESIGN INTENT WHERE IT IS ALTERED
BY EXISTING CONDITIONS OR WHERE NEGLECTED IN THE DOCUMENTS.
E. ANY MATERIALS PROPOSED FOR SUBSTITUTION OF THOSE SPECIFIED OR CALLED OUT BY TRADE NAME IN THESE DOCUMENTS
SHALL BE PRESENTED TO THE ARCHITECT FOR REVIEW. THE CONTRACTOR SHALL SUBMIT SAMPLES WHEN REQUIRED BY THE
ARCHITECT. AND ALL SUCH SAMPLES SHALL BE REVIEWED BY THE ARCHITECT BEFORE THE WORK IS PERFORMED. WORK MUST
CONFORM TO THE REVIEWED SAMPLES. ANY WORK WHICH DOES NOT CONFORM SHALL BE REMOVED AND REPLACED WITH
WORK WHICH CONFORMS AT THE CONTRACTOR'S EXPENSE. SUBCONTRACTORS SHALL SUBMIT REQUESTS AND SAMPLES FOR
REVIEW THROUGH THE GENERAL CONTRACTOR WHEN WORK IS LET THROUGH HIM OR HER. REQUIRED VERIFICATIONS AND
SUBMITTALS TO BE MADE IN ADEQUATE TIME AS TO NOT DELAY PROGRESS.
F. SHOP DRAWINGS MUST BE THOROUGHLY REVIEWED BY CONTRACTOR PRIOR TO SUBMITTING TO ARCHITECT TO MAKE SURE
THEY ARE ACCURATE AND MEET DESIGN INTENT. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR HIS OR HER
REVIEW WHERE CALLED FOR ANYWHERE IN THESE DOCUMENTS. REVIEW SHALL BE MADE BY THE ARCHITECT BEFORE WORK IS
BEGUN, AND WORK SHALL CONFORM TO THE REVIEWED SHOP DRAWINGS, SUBJECT TO REPLACEMENT AS REQUIRED IN
PARAGRAPH E ABOVE. ARCHITECT WILL TRY TO IDENTIFY ANY DISCREPENCIES IN SHOP DRAWINGS, BUT CONTRACTOR IS
ULTIMATELY RESPONSIBLE FOR SHOP DRAWING ACCURACY.
G. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR WHEN THERE IS NEED OF INSPECTION AS REQUIRED BY THE
2009 INTERNATIONAL RESIDENTIAL CODE OR ANY LOCAL CODE OR ORDINANCE.
H. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION,
FOR COMPLIANCE WITH FEDERAL AND STATE O.S.H.A. REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS
DELIVERED COMPLETED TO THE OWNER.
I. ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALED DIMENSIONS. DIMENSIONS NOTED WITH "N.T.S." DENOTES NOT TO
SCALE.
J. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS, CEILINGS, AND WALLS WITH ALL
ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS.
K. CONTRACTOR TO COORDINATE NEW CONSTRUCTION W/EXISTING CONDITIONS AND NOTIFY ARCHITECT AND STRUCTURAL
ENGINEER ABOUT DISCREPENCIES OF DRAWINGS OF EXISTING HOUSE AND ASSUMPTIONS.
GENERAL NOTES
KRM Consultants Inc.
Contact: Tim Hennum
P.O. Box 4572
Vail, CO 81658
Office: (970) 949-9391
Fax: (970 949-0839
krm@krmconsultants.com
Neils Lunceford, Inc.
Contact: Dan Skinner
P.O. Box 2130
740 Blue River Parkway
Silverthorne, CO 80498
Office: (970) 468-0340
Fax: (970 468-6865
danskinner@neilslunceford.
com
1/4" = 1'-0"
7/28/2014 12:08:37 PM
A1.0
COVER
SHEET
AC
HB, SLJ
LEEVER RESIDENCE
7-28-14
5087 Main Gore Drive North, Vail CO
Subdivision: Bighorn 5th Addition Block: 1 Lot: 2
FINAL DRB SUBMITTAL
LEEVER RESIDENCE
5087 Main Gore Drive North, Vail CO
Subdivision: Bighorn 5th Addition Block: 1 Lot: 2
7-28-14
FINAL DRB SUBMITTAL
A1.0 COVER SHEET
SURVEY
LANDSCAPE DRAWINGS
L1 PHASE 1 LANDSCAPE PLAN
L2 PHASE 1 LANDSCAPE PLAN DETAILS
ARCHITECTURAL DRAWINGS
A2.0 SITE PLAN
A2.1 LANDSPACE CALCS
A2.2 CONSTRUCTION MANAGEMENT PLAN
A2.3 AREA CALCS
A3.1 MAIN LEVEL FLOOR PLAN
A3.2 UPPER LEVEL FLOOR PLAN
A3.3 ROOF PLAN
A4.1 ELEVATIONS
A4.2 ELEVATIONS
A4.3 GARAGE ELEVATIONS
A4.4 PARTIAL ELEVATIONS
A4.5 3D VIEWS
A5.1 BUILDING SECTIONS
A5.2 BUILDING SECTIONS
A5.3 BUILDING SECTIONS
A6.1 FOUNDATION DETAILS
A6.2 FOUNDATION DETAILS
A6.3 WALL DETAILS
A6.4 ROOF DETAILS
A6.5 DETAILS
A8.0 WINDOW & DOOR SCHEDULE
A8.1 WINDOW & DOOR DETAILS
A10.2 MAIN LEVEL RCP
A10.3 UPPER LEVEL RCP
STRUCTURAL DRAWINGS
MECHANICAL DRAWINGS
CODE: 2012 IRC, 2012 IECC OCCUPANCY TYPE: SINGLE FAMILY HOME
ENERGY CONSERVATION: THE BUILDING COMPLIES WITH THE ENERGY CONSERVATION REQUIREMENT FROM CHAPTER 4 OF THE 2012 INTERNATIONAL ENERGY CODE PER ZONE 6B ADOPTED
BY THE TOWN OF VAIL, AS FOLLOWS:
The following is a summary for the climate zone 6B of Table 402.1.1 requirements of the IEC (including the 10-1-9: AMENDMENTS TO ENERGY CONSERVATION CODE as adopted by The Town of Vail :, and an
outline of the proposed R values of the assemblies of the building which are defined in the Construction Document Drawings and Specifications:
Maximum Glazing U-Factor of .30 for new single family dwelling units per Town of Vail amendments
The Jeld-Wen windows double glazed w/ low E (EC) 366 @ surface 2 and i89 @ surface 4 meets this requirement - average U-Factor .30
Ceilings & Roofs Insulation - Requirement of R-49 which is reduced to R-38 per 402.2.1 since the construction techniques provide a full R-38 insulation value over the wall top plate.
@ Typical Roof Condition - The design provides a full R-38 insulation value over the wall top plate as follows: Provide R62.4 at roof Cavities with 5/8" plywood over 14” TJIs: Provide R62.4 with 4” minimum of 2#
closed cell spray foam insulation with an R value of 6.6 per inch equaling R26.4 and 10” of blown in cellulose insulation with R3.6 per inch equaling R36.
Crawlspace Walls Insulation - Requires R-15 of continuous insulation or R-19 cavity insulation : Provide R-15 with 3" exterior insulation/drainagemedium with R5 per inch over the typical 8" concrete wall.
Exterior Walls Insulation - Requires R-20: Exterior walls with 5.5” cavity: Provide R25.8 with 2” minimum of spray foam insulation @ inside of sheathing with an R value of 6.6 per inch equaling R13.2 and 3.5” of
blown in cellulose insulation with R3.6 per inch equaling R12.6 or approved equal.
Floor Insulation - Requires R-30: The building has been designed with a conditioned crawlspace at the main house and slab on grade at garage.
@ Floor over Outdoor Room Master Bedroom Overhang) - Provide 2" min. spray foam insulation @ underside of floor sheathing w/ an R-Value of 6.6 per inch equaling 13.2 and 12" of blown in cellulose insulation w/
R-3.6 per inch equaling R-43.2 providing a total insulation value of R-56.4.
@ Floor over Crawlspace - Provide 12" min of blown in cellulose insulation w/ R-3.6 per inch equaling R-43.2.
@Garage Slab - Requires R-15 for 4' horizontally under slab (since the slab is heated). Provide R15 with R5 ridged insulation under the slab and and R-10 continuous @ exterior of foundation.
Provide full cavity blown in cellulose sound insulation at all interior walls and at all floor assemblies.
ADDITIONAL REQUIREMENTS PER TOWN OF VAIL CODE AMENDMENTS:
ROOF COVERING: Meets Section 1505.6 of the Town of Vail Code- The standing seam metal roofing will be installed to meet the required Class A roof or Class A roof assembly.
FIRE SPRINKLER SYSTEM AND ALARM: Design Build - Building is to be equipped throughout with an automatic sprinkler system installed in accordance with NFPA 13 and the Town of Vail.
A monitored fire alarm system will also be provided in compliance with the Town of Vail codes and regulations.
PLUMBING: Design Build - See Architectural Drawings for fixture locations only.
MECHANICAL: Design Build
ELECTRICAL: Design Build
Leever Residence
5087 Main Gore Drive North, Subdivision: Bighorn 5th Addition Block: 1 Lot: 2
Zone District: Single Family Residential ( SFR )
Lot is .613 acres, equal to 26,702 SF
Allowable GRFA
.46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.4 equals 4,000 SF
.13 SF per 1 SF of site area > 10,000 SF of site area 16,702 x 0.13 equals 2,171 SF
_______________________________________________________________________
Total Allowed Gross Residential Floor Area (GRFA) for entire lot 6,171 SF
Allowable site coverage is 20% of lot 5,340 SF
Square Footage Summary Habitable SF GRFA SF
Main Level 2,456 SF 2,456 SF
Upper Level 2,306 SF 2,306 SF
Subtotal Finished 4,762 SF
Bonus Room (unfinished) 1,026 SF 1,026 SF
Garage (additional area beyond allowance) 336 SF 336 SF
____________________________________________________________________
Total 6,124 SF 6,124 SF
Provided SF Allowed SF
Garage 936 SF 600 SF
Site Coverage 3,827 SF 5,340 SF
GRFA 6,124 SF 6,171 SF
Site Coverage
Allowable site coverage is 20% of lot which equals 5,340 SF. 3,827 SF is provided.
See Sheet A2.1 for landscape coverage information.
Setbacks
20' from front
15' from sides
15' from rear
Patio can extend to 1/2 the distance of the setback
Decks can encroach set back 5'
Roof or architectural projections can encroach 4'
Height
Sloping roof not to exceed 33'
Garage
Allow 600 sq. ft. per unit. 936 SF is provided.
Parking Required per Chapter 10
If dwelling is more than 5,500 GRFA 5 spaces are required. 3 covered 9' x 18' (in garage) and 2 uncovered 9' x 19' parking spaces are
provided.
No.
Revision
Description Revision Date
DRB
APPROVED
8/21/2014 12:00:00 AM
6,168