HomeMy WebLinkAboutDRB140314_Leever Residence_A3-3 - ROOF PLAN_1410964020.pdfA4.1 1 A4.1 2 A4.2 2 A4.2 1 1 1/2" / 12" 1 1/2" / 12" 2" / 12" 2" / 12" 2" / 12" A4.3 3 A4.3 2 3' - 0" 2' - 0" 2' - 0" 4' - 0" 5' - 0" 3' - 0" 4' - 0" 3' - 0" 3' - 11 3/4" 3' - 0" 2' - 0" 3' - 0" 2' - 0" 3' - 6" 1' - 0" 1' - 0 1/16" 5' - 0" 3' - 0" 1' - 0" 3' - 0" 1 A5.1 2 A5.1 3 A5.1 1 A5.2 3 A5.2 4 A5.1 2 A5.2 BUILDING HEIGHT #2 8570' - 4 1/2" EXISTING GRADE DIRECTLY BELOW BUILDING HEIGHT #2 8537' - 6 1/8" EXISTING GRADE DIRECTLY BELOW BUILDING HEIGHT #1 8533' - 11 3/8" BUILDING HEIGHT #1 8566' - 7 1/2" BUILDING HEIGHT #3 8570' - 4 1/2" EXISTING GRADE DIRECTLY BELOW BUILDING HEIGHT #3 8538' - 5 1/8" A4.3 1 3' - 0" 2' - 0" 3' - 0"3' - 0" 1' - 0" 1 1/2" / 12" 2 1/2" / 12" 2 1/2" / 12" 4 ' - 0 " 4' - 8" 2' - 0" 1' - 6" 1 A5.3 2 A5.3 4 A5.2 1 1 2 2 3 3 4 5 5 6 6 7 7 8 8 9 9 1A 1A 1B 1B 1C 1C 1D 1D 1AA A A B B C C D D F F G G H H AA BB CC DD EE AAA 12' - 9" 5' - 3" 10' - 9" 7' - 6" 7' - 6" 13' - 6" 1' - 6" 3' - 0" 12' - 9" 5' - 3" 10' - 9" 7' - 6" 7' - 6" 13' - 6" 1' - 6" 3' - 0" 11' - 8 1/2" 23' - 3 1/2" 6' - 0" 11' - 8 1/2" 23' - 3 1/2" 6' - 0" 3' - 0" 18' - 0" 2' - 0" 11' - 9" 9' - 6" 9' - 0" 3' - 0" 18' - 0" 2' - 0" 11' - 9" 9' - 6" 9' - 0" 1' - 9"1' - 10"23' - 6"2' - 6" GUTTER DOWNSPOUT TYP. GUTTER RE: SPEC COORDINATE HEAT TAPE RE: ELEC GUTTER DOWNSPOUT TYP. GUTTER RE: SPEC COORDINATE HEAT TAPE RE: ELEC 1 A6.4 1 A6.4 1 A6.4 1 A6.4 4 A6.4 3 A6.4 3 A6.4 3 A6.4 6 A6.4 6 A6.4 6 A6.4 6 A6.4 5 A6.4 2 A6.4 2 A6.4 2 A6.4 2 A6.4 2 A6.4 3 A6.4 4 A6.4 E E FUTURE GREENHOUSE GENERAL NOTES: LOT SIZE IS .613 ACRES EQUAL TO 26,702 SF 1.) ALL ROOF HEIGHTS ARE TO THE TOP OF SHEATHING ON ROOF PLAN SITE PLAN. 2.) PROVIDE DESIGN-BUILD ENGINEERED SNOW GUARD FENCE SYSTEM @ ALL ROOF AREAS ATTACHED TO RIBS ON STANDING SEAM ROOF PER ROOF SLOPE, TYPE AND SNOW LOAD. SUBMIT ENGINEERED DESIGN FOR REVIEW. SEE SPEC FOR MORE INFORMATION. 3.) SEE ELEVATIONS FOR J-BOX LOCATIONS FOR HEAT TAPE FOR GUTTER AND FUTURE HEAT TAPE. PROVIDE HEAT TAPE FOR ALL DOWNSPOUTS, GUTTERS, UNDERGROUND HARDPIPE TO DAYLIGHT, AND FUTURE 3' HIGH SECTION OF HEAT TAPE AT ROOF EAVE ABOVE GUTTER. 4.) ROOF HEIGHT CALCULATIONS (ALSO SHOWN ON SITE PLAN): MEASURED TO TOP OF SHEATHING ON TOP OF STRUCTURAL ROOF TO FINISHED OR EXISTING GRADE DIRECTLY BELOW (WHICHEVER IS MORE RESTRICTIVE). DOES NOT INCLUDE APPROX. 1" OF ROOFING. *1- ROOF EAVE HEIGHT @ SHEATHING = 8566' - 7 1/2" EXISTING GRADE BELOW EAVE = 8533' - 11 3/8" FINISHED GRADE BELOW EAVE = 8538' - 10 7/8" ROOF HEIGHT = 32' - 8 1/8" *2- ROOF EAVE HEIGHT @ SHEATHING = 8570' - 4 3/8" EXISTING GRADE BELOW EAVE = 8537' - 6 1/8" ROOF HEIGHT = 32'- 10 1/4" *3- ROOF EAVE HEIGHT @ SHEATHING = 8570'- 4 3/8" EXISTING GRADE BELOW EAVE = 8538'- 5 1/8" ROOF HEIGHT = 32' - 11 1/4" Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 7/28/2014 12:12:31 PM A3.3 ROOF PLAN AC HB, SLJ LEEVER RESIDENCE 7-28-14 5087 Main Gore Drive North, Vail CO Subdivision: Bighorn 5th Addition Block: 1 Lot: 2 FINAL DRB SUBMITTAL 1/4" = 1'-0" 1 ROOF PLAN 0' 2' 4' 8' 16' No. Revision Date Revision Description DRB APPROVED 8/21/2014 12:00:00 AM