HomeMy WebLinkAboutDRB140314_Leever Residence_A6-1 - FOUNDATION DETAILS_1410964020.pdfPRESSURE TREATED WOOD LEDGER PRESSURE TREATED PLATE SLOPE CRAWLSPACE INTERIOR EXTERIOR RE: STRUCT RE: STRUCT. GRID LINE 3D DRAINAGE /AIR & WATER INFILTRATION BARRIER LAPS OVER ICE & WATER SHIELD, WEEP SCREED & FLASHING FLASHING RE: SPEC EXTENDS INTO GRADE MIN 3" PROVIDE 8" STRIP OF BITUTHANE CENTERED ON JOINT BETWEEN WOOD & CONCRETE MIN. 6" FINISH FLOOR RE: FLOOR PLANS AND SPEC STUCCO VENEER OVER METAL LATH OVER 3D DRAINAGE MATERIAL / AIR AND WATER INFILTRATION BARRIER CONT. @ WALL. LAP OVER 30" HIGH ICE & WATER SHIELD WHICH IS CONT. @ BTM WALL. PROVIDE WEEP SO THAT DRAINAGE MEDIUM CAN DRAIN AT BO WALL. CONCRETE FOUNDATION WALL RE: STRUCTURAL DRAWINGS CONCRETE FOUNDATION PIER RE: STRUCTURAL DRAWINGS MIRA DRAIN DRAINAGE MEDIUM OVER MIN. R-15 RIGID FOAM INSULATION PANEL RE: SPEC OVER WATERPROOF MEMBRANE. ALTERNATE MIN R-15 COMBINATION INSULATION / DRAINAGE MEDIUM MAY BE PROPOSED PER SPEC. 4" DIA. RIGID PERFORATED PIPE SURROUNDED BY FILTER FABRIC AND A MIN. OF 4 INCHES OF DRAIN GRAVEL SLOPED 1% MIN. TO DAYLIGHT PER SOILS REPORT. RE SOILS REPORT FOR ADDITIONAL FOUNDATION & PERIMETER DRAIN REQUIREMENTS & SPEC W.P. MEMBRANE CONT. FROM B.O. WALL TO T.O. CONC. WALL 10 MIL VAPOR BARRIER TURNS UP WALL MECH FASTEN AND SEAL TO WALL. SEAL ALL JOINTS AND PENETRATIONS TYP. TYPICAL FOUNDATION NOTES: 4" MIN. DRAIN GRAVEL BASE RE: SOILS ENGINEER RECOMMENDATIONS/STRUCT. T.O. FOOTING RE: STRUCT. T.O. PLYWOOD RE: FLOOR PLANS WEEP SCREED PRESSURE TREATED WOOD LEDGER PRESSURE TREATED PLATE SLOPE CRAWLSPACE INTERIOR EXTERIOR RE: STRUCT RE: STRUCT. GRID LINE 3D DRAINAGE /AIR & WATER INFILTRATION BARRIER LAPS OVER ICE & WATER SHIELD, WEEP SCREED & FLASHING FLASHING RE: SPEC EXTENDS INTO GRADE MIN 3" PROVIDE 8" STRIP OF BITUTHANE CENTERED ON JOINT BETWEEN WOOD & CONCRETE MIN. 6" FINISH FLOOR RE: FLOOR PLANS AND SPEC T.O. FOOTING RE: STRUCT. T.O. PLYWOOD RE: FLOOR PLANS WEEP SCREED NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES 3D DRAINAGE /AIR & WATER INFILTRATION BARRIER LAPS OVER ICE & WATER SHIELD & FLASHING SLOPE RE: PLANS RE: STRUCT. RE: STRUCT. RE: STRUCT. 5" CONC. SLAB ON GRADE RE: STRUCT. INTERIOR EXTERIOR GRID LINE 1/2" EXPANSION JOINT WITH BEVEL CUT TOP 2" FOAM @ SLAB EDGE W.P. EPOXY LIQUID GRANITE FLOORING OVER CONC. SLAB AND TURNS UP WALL MIN 6" RE: SPEC NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES MIRA DRAIN DRAINAGE MEDIUM OVER MIN. R-10 RIGID FOAM INSULATION PANEL RE: SPEC OVER WATERPROOF MEMBRANE. 10 MIL VAPOR BARRIER TURN UP WALL SEAL AND MECH FASTEN TO CONC WALL. WEEP SCREED FLASHING RE: SPEC EXTENDS INTO GRADE MIN 3" STUCCO VENEER OVER METAL LATH RE: SPEC MIN. 6" T.O. CONC. SLAB RE: FLOOR PLANS 3D DRAINAGE /AIR & WATER INFILTRATION BARRIER LAPS OVER ICE & WATER SHIELD & FLASHING SLOPE RE: PLANS RE: STRUCT. RE: STRUCT. RE: STRUCT. 5" CONC. SLAB ON GRADE RE: STRUCT. INTERIOR EXTERIOR GRID LINE 1/2" EXPANSION JOINT WITH BEVEL CUT TOP 2" FOAM @ SLAB EDGE W.P. EPOXY LIQUID GRANITE FLOORING OVER CONC. SLAB AND TURNS UP WALL MIN 6" RE: SPEC NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES MIRA DRAIN DRAINAGE MEDIUM OVER MIN. R-10 RIGID FOAM INSULATION PANEL RE: SPEC OVER WATERPROOF MEMBRANE. 10 MIL VAPOR BARRIER TURN UP WALL SEAL AND MECH FASTEN TO CONC WALL. WEEP SCREED FLASHING RE: SPEC EXTENDS INTO GRADE MIN 3" STUCCO VENEER OVER METAL LATH RE: SPEC MIN. 6" T.O. CONC. SLAB RE: FLOOR PLANS 1/2" P.T. PLYWOOD RAMSET TO CONCRETE RE: STRUCT. CONC. WALL RE:STRUCT W.P. MEMBRANE CONT. FROM B.O. FOOTING TO T.O. CONC. SLOPE T.O. FOOTING RE: STRUCT. CRAWLSPACE INTERIOR EXTERIOR RE: STRUCT RE: STRUCT. STONE VENEER RE: ELEVATIONS & SPEC MIRADRAIN OVER 2" RIGID INSULATION MIN. R-10 RE: SPEC NO VAPOR BARRIER @ SUBGRADE WALLS P.T 2X6 WALL FRAMED ON T.O FURRED WALL T.O. CONRETE WALL RE: STRUCT GRID LINE 6" MIN. 5" 1/2" P.T LEDGER JOIST HANGER RE: STRUCT SLOPE GRADE @ 10% FOR 10' AWAY FROM BUILDING PER SOILS ENGINEER LAP ICE & WATER SHIELD MIN. 6" OVER CONC. FOUNDATION & EXTEND UP WALL MIN. 30" NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES PRESSURE TREATED WOOD LEDGER PRESSURE TREATED PLATE CONC. WALL RE: STRUCT. W.P. MEMBRANE CONT. FROM B.O. FOOTING TO T.O. CONC. FINISHED FLOOR RE: PLANS GRAVEL BED PER SOILS ENGINEER SLOPE T.O. FOOTING RE: STRUCT. T.O. PLYWOOD RE: FLOOR PLANS CRAWLSPACE INTERIOR EXTERIOR RE: STRUCT RE: STRUCT. STEEL LEDGER RE: STRUCT . GRID LINE SLOPE GRADE @ 10% AWAY FROM BUILDING FOR MIN. 10' PER SOILS ENGINEER STONE VENEER RE:A6.X AND ELEVATIONS MIN. R-10 RIGID INSULATION/DRAINAGE BOARD RE: SPEC NO VAPOR BARRIER @ LOWER LEVEL/SUBGRADE WALLS NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES MIN. 6" FINISHED FLOOR RE: PLANS AND SPEC OVER GYPCRETE W/ IN-FLOOR RADIANT HEAT RE: PLANS AND SPEC T.O. PLYWOOD RE: PLANS CRAWLSPACE INTERIOR EXTERIOR FILL JOIST CAVITY W/ INSULATION RE: SPEC. GRID LINE 5" RE: STRUCT. RE: STRUCT. 14" LVL LEDGER RE: STRUCT 3" FLAGSTONE ASSEMBLY - APPROX. 1 1/2" TO 2" OF STONE OVER 1" TO 1 1/2" GROUT OVER CONC. SLAB. PROVIDE 2" RIGID INSULATION OVER 2" VOID ATTACH RIGID INSULATION TO UNDERSIDE OF CONC. SLAB W/ WIRE TIRES RE: SPEC W.P. MEMBRANE CONT. OUT HORIZONTALLY 3'-0" CONTINUE MEMBRANE UP WALL AND UNDER WINDOW SILL NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES TYP. WINDOW SILL DETAIL RE: X/A6.X PROVIDE BITUTHANE CONTINUOUS UNDER WINDOW SILL AND LAP OVER W.P. @ FOUNDATION WALL MIN 6" 1X P.T. PLATE 6" SLOPE RE: PLANS COPPER FLASHING RE: SPEC TURN UP WALL 6" MIN. T.O. STONE PATIO VARIES STRUCTURAL SLAB DOWELED INTO FOUNDATION WALL RE: STRUCT. SLOPE RE: PLANS RE: STRUCT. RE: STRUCT. RE: STRUCT. 5" STONE VENEER WALL ASSEMBLY RE: A6.1 CONC. SLAB ON GRADE RE: STRUCT. GARAGE EXTERIOR 3" MIN. GRID LINE 3" ASPHALT OVER 4" COMPACTED ROAD BASE RE: SPEC 1/2" EXPANSION JOINT WITH BEVEL CUT TOP 2" FOAM @ SLAB EDGE W.P. EPOXY LIQUID GRANITE FLOORING OVER CONC. SLAB AND TURNS UP WALL MIN 6" RE: SPEC NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES MIN R-10 RIGID FOAM INSULATION PANEL 10 MIL VAPOR BARRIER TURN UP WALL SEAL AND MECH FASTEN TO CONC WALL. SLOPE RE: PLANS RE: STRUCT. RE: STRUCT. RE: STRUCT. 5" CONC. SLAB ON GRADE RE: STRUCT. GARAGE EXTERIOR GRID LINE 3" ASPHALT OVER 4" COMPACTED ROAD BASE RE: SPEC 1/2" EXPANSION JOINT WITH BEVEL CUT TOP 2" FOAM @ SLAB EDGE W.P. EPOXY LIQUID GRANITE FLOORING OVER CONC. SLAB AND TURNS UP WALL MIN 6" RE: SPEC NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES MIN R-10 RIGID FOAM INSULATION PANEL 10 MIL VAPOR BARRIER TURN UP WALL SEAL AND MECH FASTEN TO CONC WALL. WEEP SCREED STUCCO VENEER OVER METAL LATH RE: SPEC Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1 1/2" = 1'-0" 7/28/2014 12:15:23 PM A6.1 FOUNDATION DETAILS AC HB, SLJ LEEVER RESIDENCE 7-28-14 5087 Main Gore Drive North, Vail CO Subdivision: Bighorn 5th Addition Block: 1 Lot: 2 FINAL DRB SUBMITTAL 1 1/2" = 1'-0" 1 FOUNDATION DETAIL @ JOISTS SITTING ON FOUNDATION WALL 1 1/2" = 1'-0" 2 FOUNDATION DETAIL @ JOISTS SITTING ON FOUNDATION WALL - LOW GRADE 1 1/2" = 1'-0" 3 FOUNDATION DETAIL @ GARAGE - STUCCO VENEER @ GRADE 1 1/2" = 1'-0" 4 FOUNDATION DETAIL @ GARAGE - RAISED CONCRETE WALL 1 1/2" = 1'-0" 5 FOUNDATION DETAIL @ CONCRETE CURB @ STONE VENEER 1 1/2" = 1'-0" 6 FOUNDATION DETAIL @ STONE VENEER 1 1/2" = 1'-0" 7 FOUNDATION DETAIL @ MAIN LEVEL PATIO 1 1/2" = 1'-0" 8 FOUNDATION DETAIL - GARAGE STONE VENEER @ DRIVEWAY 1 1/2" = 1'-0" 9 FOUNDATION DETAIL - GARAGE STUCCO VENEER @ DRIVEWAY No. Revision Date Revision Description DRB APPROVED 8/21/2014 12:00:00 AM