HomeMy WebLinkAboutDRB140314_Leever Residence_A6-2 - FOUNDATION DETAILS_1410964020.pdfT.O. CONCRETE WALL
RE: STRUCT
SLOPE TO DRAIN
GARAGE
EXTERIOR
CONC. SLAB W/ IN-FLOOR
RADIANT HEAT SLOPED
PER PLANS
10 MIL. VAPOR BARRIER TURNS UP
WALL MECH. FASTEN AND SEAL TO
WALL. SEAL ALL JOINTS AND
PENETRATIONS TYP. RE: SPEC
GRAVEL BED PER SOILS ENGINEER, STRUCT
AND CIVIL DRAWINGS
SMART MEMBRANE VAPOR BARRIER RE: SPEC
W.P. EPOXY LIQUID GRANITE FLOORING
OVER CONC. SLAB AND TURNS UP WALL
MIN. 6"
RE: SPEC
5/8" GYP SHEATHING OR MOISTURE
RESISTANT DRYWALL
OUTSWING DOOR RE: DOOR SCHEDULE.
POUR SLAB AFTER ELECTRIC
CONDUIT IS INSTALLED
P.T. PLYWOOD OVER FOUNDATION
WATERPROOFING OVER CONCRETE
FOUNDATION & WITHIN 6" OF GRADE
RE:SPEC
ELECTRIC CLOSET
1/2" EXPANSION JOINT
NOTE: SEE 1/A6.1 FOR TYPICAL
FOUNDATION NOTES
5"
RE: STRUCT.
CONC. FOUNDATION BEYOND
1/2" P.T. PLYWOOD RAMSET TO
CONCRETE
NON PAPER-FACED GYP. SHEATHING
OVER CONCRETE
GARAGE
EXTERIOR
2X TRIM BOARD AT GARAGE DOOR
JAMB BEYOND
RE: STRUCT.
RE: STRUCT.
CONC. SLAB SLOPED TO DRAIN
RE: STRUCT AND FLOOR PLANS
W.P. MEMBRANE CONT. FROM
B.O. FOOTING TO T.O. CONC.
SLOPE
GRID
LINE
SLOPE GARAGE SLAB AT THRESHOLD
MIRADRAIN DRAIN DRAINAGE
MEDIUM. MIRADRAIN IS CONT. @
WALL AND TOP OF FOOTING RE:
SPEC
0' - 1"
GARAGE DOOR
PROVIDE GASKET AT B.O. GARAGE DOOR
10 MIL VAPOR BARRIER
4" COMPACTED ROAD BASE RE: SPEC
APPROX. 3" ASPHALT RE:SPEC
WATER PROOF EPOXY LIQUID GRANITE
FLOORING OVER CONC. SLAB
RE: SPEC
SLOPE
NOTE: SEE 1/A6.1 FOR TYPICAL
FOUNDATION NOTES
NOTE: SEE 1/A6.1 FOR TYPICAL
FOUNDATION NOTES
PRESSURE TREATED WOOD LEDGER
PRESSURE TREATED PLATE
CONC. WALL RE: STRUCT.
W.P. MEMBRANE CONT. FROM B.O.
FOOTING TO T.O. CONC.
FINISHED FLOOR RE: PLANS
GRAVEL BED PER SOILS
ENGINEER
T.O. FOOTING
RE: STRUCT.
T.O. PLYWOOD
RE: FLOOR PLANS
CRAWLSPACE
INTERIOR
RE: STRUCT
RE: STRUCT.
STEEL LEDGER RE: STRUCT .
NO VAPOR BARRIER @ LOWER
LEVEL/SUBGRADE WALLS
NOTE: SEE 1/A6.1 FOR TYPICAL
FOUNDATION NOTES
CONT. RIGID FOAM INSULATION
PANEL UNDER SLAB RE: SPEC
CONCRETE SLAB RE: STRUCT
ALIGN T.O. CONC. W/ T.O. FINISHED FLOOR
10"
RE: STRUCT.
1/2" EXPANSION JOINT RE: STRUCT.
R-10 INSULATION/DRAINAGE
MEDIUM OVER W.P. MEMBRANE
CONT. FROM B.O. FOOTING TO T.O.
CONCRETE RE: SPEC
INTERIOR
W.P. EPOXY LIQUID GRANITE FLOORING
OVER CONC. SLAB RE: SPEC
FINISHED FLOOR RE: PLANS AND SPEC
OVER GYPCRETE W/ IN-FLOOR RADIANT
HEAT RE: PLANS AND SPEC
T.O. PLYWOOD
RE: PLANS
CRAWLSPACE
INTERIOR
EXTERIOR
FILL JOIST CAVITY W/ INSULATION
RE: SPEC.
GRID
LINE
SEALANT JOINT @ DOOR
RE: STRUCT.
RE: STRUCT.
RE: STRUCT.
14" LVL LEDGER RE: STRUCT
AUTOMATIC DOOR SWEEP
ACTIVATED BY PIN @ JAMB
3/4"
METAL FLASHING CONT. OVER T.O.
CONC WALL AND TURN UP 1/2" BTW
DOOR THRESHOLD AND FINISH
FLOOR
CUSTOM CUT STONE DOOR SILL
SET IN BED OF SEALANT/ ADHESIVE
1/2" RADIUS EASED EDGE
3" 3" FLAGSTONE ASSEMBLY - APPROX. 1 1/2" TO 2"
OF STONE OVER 1" TO 1 1/2" GROUT W/ RADIANT
SNOWMELT HEATING TUBES IN THE GROUT OVER
CONC. SLAB. SECURE TUBING TO CONC SLAB W/
CLIPS RAMSET TO CONCRETE OR ATTACH TO
WELDED WIRE MESH SECURED TO T.O. SLAB
PROVIDE 2" RIGID INSULATION OVER 2" VOID
ATTACH RIGID INSULATION TO UNDERSIDE OF
CONC. SLAB W/ WIRE TIRES RE: SPEC
W.P. MEMBRANE CONT. OUT HORIZONTALLY
3'-0" CONTINUE MEMBRANE UP WALL 1'-6" AND
UNDER DOOR SILL
2 1/4"
NOTE: SEE 1/A6.1 FOR TYPICAL
FOUNDATION NOTES
1 1/4"
STRUCTURAL SLAB DOWELED
INTO FOUNDATION WALL
RE: STRUCT.
FINISHED FLOOR RE: PLANS AND SPEC
OVER GYPCRETE W/ IN-FLOOR RADIANT
HEAT RE: PLANS AND SPEC
T.O. PLYWOOD
RE: PLANS
CRAWLSPACE
INTERIOR
EXTERIOR
FILL JOIST CAVITY W/ INSULATION
RE: SPEC.
GRID
LINE
14" LVL LEDGER RE: STRUCT
METAL FLASHING CONT. OVER T.O.
CONC WALL AND 1X PLATE TURN UP
1/2" OVER WINDOW SILL AND TRIM
3"
3" FLAGSTONE ASSEMBLY - APPROX.
1 1/2" TO 2" OF STONE OVER 1" TO 1
1/2" GROUT OVER CONC. SLAB.
PROVIDE 2" RIGID INSULATION OVER
2" VOID ATTACH RIGID INSULATION
TO UNDERSIDE OF CONC. SLAB W/
WIRE TIRES RE: SPEC
W.P. MEMBRANE CONT. OUT
HORIZONTALLY 3'-0" CONTINUE
MEMBRANE UP WALL 1'-6" AND
UNDER DOOR SILL
NOTE: SEE 1/A6.1 FOR TYPICAL
FOUNDATION NOTES
WINDOW SET IN A BED OF SEALANT
SEALANT JOINT
PROVIDE BITUTHANE
CONTINUOUS UNDER WINDOW
SILL AND LAP OVER W.P. @
FOUNDATION WALL MIN 6"
1X P.T. PLATE
STRUCTURAL SLAB DOWELED
INTO FOUNDATION WALL
RE: STRUCT.
PRESSURE TREATED WOOD LEDGER
JOIST HANGER
CONC. WALL RE: STRUCT.
W.P. MEMBRANE CONT. FROM B.O. FOOTING
FINISHED FLOOR RE:
PLANS
GRAVEL BED PER SOILS ENGINEER
T.O. FOOTING
RE: STRUCT
T.O. PLYWOOD
RE: FLOOR PLANS
CRAWLSPACE
INTERIOR EXTERIOR
RE: STRUCT
RE: STRUCT.
GRID
LINE
2" RIGID INSULATION MIN. R-10 RE: SPEC
NO VAPOR BARRIER @ LOWER
LEVEL/SUBGRADE WALLS
SLOPE 1/8" : 1'-0"
1"
DOOR SILL SET IN BED OF
SEALANT OVER COPPER
FLASHING
NOTE: SEE 1/A6.1 FOR TYPICAL
FOUNDATION NOTES
SEE X/A6.X FOR TYP. STONE
PATIO ASSEMBLY
B.O. WALL
RE: STRUCTURAL DRAWINGS
HSS 3X3 STEEL COLUMN RE:
STRUCT.
BASE PLATE ATTACHED TO PIER WITH
EXPANSION BOLTS RE: STRUCT. PAINT
W/ ASPHALTIC DAMP PROOFING
RE:STRUCT
APPLY ASPHALTIC DAMP PROOFING TO
STEEL WITHIN MASONRY ASSEMBLY
3" FLAGSTONE ASSEMBLY CONSISTING
OF APPROX. 1 1/2" THICK STONE OVER
APPROX. 1 1/2" MORTAR BED OVER
CONC. SLAB RE: STRUCT.
THICKENED SLAB RE: STRUCT.
RE:STRUCT
SLOPE PER PLANS
6"
10X10 WD. CENTERED ON WALL BELOW
NOTCHED FOR KNIFE PLATE ATTACHED
WITH GALVANIZED THROUGH BOLTS WITH
EXPOSED GALVANIZED WASHERS AND
BOLTS RE: STRUCT. & SPEC
STEEL CAP PLATE RE: STRUCT.
HSS 3X3 STEEL COLUMN APPLY
DAMPPROOFING TO PORTIONS OF STEEL
W/IN STONE ASSEMBLY
RE: STRUCT. PAINT PER SPEC.
PROVIDE SEALANT JOINT BTW STONE &
HSS COLUMN
OVERHANG
1 1/2"
WP MEMBRANE CONT. FROM
B.O. FOOTING TO T.O. CONC.
STEEL LEDGER RE: STRUCT
PAINTED W/ DAMPPROOFING RE: SPEC
PROVIDE WEEPS @ BASE OF
STONE OVER SUPPORTING
ANGLE
CONCRETE FOOTER
RE: STRUCTURAL DRAWINGS
6" STONE VENEER @ PERIMETER OF
PATIO TYP.
PERFORATED PERIMETER DRAIN SET IN
GRAVEL BED OVER A NON-PERMEABLE
LINER PER SOILS ENGINEER DRAWING
AND RECOMMENDATIONS
VARIES RE: PLANS
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1 1/2" = 1'-0"
7/28/2014 12:15:47 PM
A6.2
FOUNDATION
DETAILS
AC
HB, SLJ
LEEVER RESIDENCE
7-28-14
5087 Main Gore Drive North, Vail CO
Subdivision: Bighorn 5th Addition Block: 1 Lot: 2
FINAL DRB SUBMITTAL
1 1/2" = 1'-0"
1
FOUNDATION DETAIL @ ELECTRICAL
CLOSET
1 1/2" = 1'-0"
2
FOUNDATION DETAIL @ GARAGE DOOR
THRESHOLD
1 1/2" = 1'-0"
3
FOUNDATION DETAIL @ SLAB TO
FRAMED FLOOR TRANSITION
1 1/2" = 1'-0"
4 THRESHOLD DETAIL @ FRONT DOOR
1 1/2" = 1'-0"
5
FOUNDATION DETAIL @ FRONT DOOR
SIDELIGHTS
1 1/2" = 1'-0"
6 THRESHOLD DETAIL @ MUDROOM DOOR
1 1/2" = 1'-0"
7
FOUNDATION DETAIL @ MAIN FLOOR
PATIO @ GRADE
No. Revision Date
Revision
Description
DRB
APPROVED
8/21/2014 12:00:00 AM