HomeMy WebLinkAboutDRB140314_Leever Residence_A6-2 - FOUNDATION DETAILS_1410964020.pdfT.O. CONCRETE WALL RE: STRUCT SLOPE TO DRAIN GARAGE EXTERIOR CONC. SLAB W/ IN-FLOOR RADIANT HEAT SLOPED PER PLANS 10 MIL. VAPOR BARRIER TURNS UP WALL MECH. FASTEN AND SEAL TO WALL. SEAL ALL JOINTS AND PENETRATIONS TYP. RE: SPEC GRAVEL BED PER SOILS ENGINEER, STRUCT AND CIVIL DRAWINGS SMART MEMBRANE VAPOR BARRIER RE: SPEC W.P. EPOXY LIQUID GRANITE FLOORING OVER CONC. SLAB AND TURNS UP WALL MIN. 6" RE: SPEC 5/8" GYP SHEATHING OR MOISTURE RESISTANT DRYWALL OUTSWING DOOR RE: DOOR SCHEDULE. POUR SLAB AFTER ELECTRIC CONDUIT IS INSTALLED P.T. PLYWOOD OVER FOUNDATION WATERPROOFING OVER CONCRETE FOUNDATION & WITHIN 6" OF GRADE RE:SPEC ELECTRIC CLOSET 1/2" EXPANSION JOINT NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES 5" RE: STRUCT. CONC. FOUNDATION BEYOND 1/2" P.T. PLYWOOD RAMSET TO CONCRETE NON PAPER-FACED GYP. SHEATHING OVER CONCRETE GARAGE EXTERIOR 2X TRIM BOARD AT GARAGE DOOR JAMB BEYOND RE: STRUCT. RE: STRUCT. CONC. SLAB SLOPED TO DRAIN RE: STRUCT AND FLOOR PLANS W.P. MEMBRANE CONT. FROM B.O. FOOTING TO T.O. CONC. SLOPE GRID LINE SLOPE GARAGE SLAB AT THRESHOLD MIRADRAIN DRAIN DRAINAGE MEDIUM. MIRADRAIN IS CONT. @ WALL AND TOP OF FOOTING RE: SPEC 0' - 1" GARAGE DOOR PROVIDE GASKET AT B.O. GARAGE DOOR 10 MIL VAPOR BARRIER 4" COMPACTED ROAD BASE RE: SPEC APPROX. 3" ASPHALT RE:SPEC WATER PROOF EPOXY LIQUID GRANITE FLOORING OVER CONC. SLAB RE: SPEC SLOPE NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES PRESSURE TREATED WOOD LEDGER PRESSURE TREATED PLATE CONC. WALL RE: STRUCT. W.P. MEMBRANE CONT. FROM B.O. FOOTING TO T.O. CONC. FINISHED FLOOR RE: PLANS GRAVEL BED PER SOILS ENGINEER T.O. FOOTING RE: STRUCT. T.O. PLYWOOD RE: FLOOR PLANS CRAWLSPACE INTERIOR RE: STRUCT RE: STRUCT. STEEL LEDGER RE: STRUCT . NO VAPOR BARRIER @ LOWER LEVEL/SUBGRADE WALLS NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES CONT. RIGID FOAM INSULATION PANEL UNDER SLAB RE: SPEC CONCRETE SLAB RE: STRUCT ALIGN T.O. CONC. W/ T.O. FINISHED FLOOR 10" RE: STRUCT. 1/2" EXPANSION JOINT RE: STRUCT. R-10 INSULATION/DRAINAGE MEDIUM OVER W.P. MEMBRANE CONT. FROM B.O. FOOTING TO T.O. CONCRETE RE: SPEC INTERIOR W.P. EPOXY LIQUID GRANITE FLOORING OVER CONC. SLAB RE: SPEC FINISHED FLOOR RE: PLANS AND SPEC OVER GYPCRETE W/ IN-FLOOR RADIANT HEAT RE: PLANS AND SPEC T.O. PLYWOOD RE: PLANS CRAWLSPACE INTERIOR EXTERIOR FILL JOIST CAVITY W/ INSULATION RE: SPEC. GRID LINE SEALANT JOINT @ DOOR RE: STRUCT. RE: STRUCT. RE: STRUCT. 14" LVL LEDGER RE: STRUCT AUTOMATIC DOOR SWEEP ACTIVATED BY PIN @ JAMB 3/4" METAL FLASHING CONT. OVER T.O. CONC WALL AND TURN UP 1/2" BTW DOOR THRESHOLD AND FINISH FLOOR CUSTOM CUT STONE DOOR SILL SET IN BED OF SEALANT/ ADHESIVE 1/2" RADIUS EASED EDGE 3" 3" FLAGSTONE ASSEMBLY - APPROX. 1 1/2" TO 2" OF STONE OVER 1" TO 1 1/2" GROUT W/ RADIANT SNOWMELT HEATING TUBES IN THE GROUT OVER CONC. SLAB. SECURE TUBING TO CONC SLAB W/ CLIPS RAMSET TO CONCRETE OR ATTACH TO WELDED WIRE MESH SECURED TO T.O. SLAB PROVIDE 2" RIGID INSULATION OVER 2" VOID ATTACH RIGID INSULATION TO UNDERSIDE OF CONC. SLAB W/ WIRE TIRES RE: SPEC W.P. MEMBRANE CONT. OUT HORIZONTALLY 3'-0" CONTINUE MEMBRANE UP WALL 1'-6" AND UNDER DOOR SILL 2 1/4" NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES 1 1/4" STRUCTURAL SLAB DOWELED INTO FOUNDATION WALL RE: STRUCT. FINISHED FLOOR RE: PLANS AND SPEC OVER GYPCRETE W/ IN-FLOOR RADIANT HEAT RE: PLANS AND SPEC T.O. PLYWOOD RE: PLANS CRAWLSPACE INTERIOR EXTERIOR FILL JOIST CAVITY W/ INSULATION RE: SPEC. GRID LINE 14" LVL LEDGER RE: STRUCT METAL FLASHING CONT. OVER T.O. CONC WALL AND 1X PLATE TURN UP 1/2" OVER WINDOW SILL AND TRIM 3" 3" FLAGSTONE ASSEMBLY - APPROX. 1 1/2" TO 2" OF STONE OVER 1" TO 1 1/2" GROUT OVER CONC. SLAB. PROVIDE 2" RIGID INSULATION OVER 2" VOID ATTACH RIGID INSULATION TO UNDERSIDE OF CONC. SLAB W/ WIRE TIRES RE: SPEC W.P. MEMBRANE CONT. OUT HORIZONTALLY 3'-0" CONTINUE MEMBRANE UP WALL 1'-6" AND UNDER DOOR SILL NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES WINDOW SET IN A BED OF SEALANT SEALANT JOINT PROVIDE BITUTHANE CONTINUOUS UNDER WINDOW SILL AND LAP OVER W.P. @ FOUNDATION WALL MIN 6" 1X P.T. PLATE STRUCTURAL SLAB DOWELED INTO FOUNDATION WALL RE: STRUCT. PRESSURE TREATED WOOD LEDGER JOIST HANGER CONC. WALL RE: STRUCT. W.P. MEMBRANE CONT. FROM B.O. FOOTING FINISHED FLOOR RE: PLANS GRAVEL BED PER SOILS ENGINEER T.O. FOOTING RE: STRUCT T.O. PLYWOOD RE: FLOOR PLANS CRAWLSPACE INTERIOR EXTERIOR RE: STRUCT RE: STRUCT. GRID LINE 2" RIGID INSULATION MIN. R-10 RE: SPEC NO VAPOR BARRIER @ LOWER LEVEL/SUBGRADE WALLS SLOPE 1/8" : 1'-0" 1" DOOR SILL SET IN BED OF SEALANT OVER COPPER FLASHING NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES SEE X/A6.X FOR TYP. STONE PATIO ASSEMBLY B.O. WALL RE: STRUCTURAL DRAWINGS HSS 3X3 STEEL COLUMN RE: STRUCT. BASE PLATE ATTACHED TO PIER WITH EXPANSION BOLTS RE: STRUCT. PAINT W/ ASPHALTIC DAMP PROOFING RE:STRUCT APPLY ASPHALTIC DAMP PROOFING TO STEEL WITHIN MASONRY ASSEMBLY 3" FLAGSTONE ASSEMBLY CONSISTING OF APPROX. 1 1/2" THICK STONE OVER APPROX. 1 1/2" MORTAR BED OVER CONC. SLAB RE: STRUCT. THICKENED SLAB RE: STRUCT. RE:STRUCT SLOPE PER PLANS 6" 10X10 WD. CENTERED ON WALL BELOW NOTCHED FOR KNIFE PLATE ATTACHED WITH GALVANIZED THROUGH BOLTS WITH EXPOSED GALVANIZED WASHERS AND BOLTS RE: STRUCT. & SPEC STEEL CAP PLATE RE: STRUCT. HSS 3X3 STEEL COLUMN APPLY DAMPPROOFING TO PORTIONS OF STEEL W/IN STONE ASSEMBLY RE: STRUCT. PAINT PER SPEC. PROVIDE SEALANT JOINT BTW STONE & HSS COLUMN OVERHANG 1 1/2" WP MEMBRANE CONT. FROM B.O. FOOTING TO T.O. CONC. STEEL LEDGER RE: STRUCT PAINTED W/ DAMPPROOFING RE: SPEC PROVIDE WEEPS @ BASE OF STONE OVER SUPPORTING ANGLE CONCRETE FOOTER RE: STRUCTURAL DRAWINGS 6" STONE VENEER @ PERIMETER OF PATIO TYP. PERFORATED PERIMETER DRAIN SET IN GRAVEL BED OVER A NON-PERMEABLE LINER PER SOILS ENGINEER DRAWING AND RECOMMENDATIONS VARIES RE: PLANS Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1 1/2" = 1'-0" 7/28/2014 12:15:47 PM A6.2 FOUNDATION DETAILS AC HB, SLJ LEEVER RESIDENCE 7-28-14 5087 Main Gore Drive North, Vail CO Subdivision: Bighorn 5th Addition Block: 1 Lot: 2 FINAL DRB SUBMITTAL 1 1/2" = 1'-0" 1 FOUNDATION DETAIL @ ELECTRICAL CLOSET 1 1/2" = 1'-0" 2 FOUNDATION DETAIL @ GARAGE DOOR THRESHOLD 1 1/2" = 1'-0" 3 FOUNDATION DETAIL @ SLAB TO FRAMED FLOOR TRANSITION 1 1/2" = 1'-0" 4 THRESHOLD DETAIL @ FRONT DOOR 1 1/2" = 1'-0" 5 FOUNDATION DETAIL @ FRONT DOOR SIDELIGHTS 1 1/2" = 1'-0" 6 THRESHOLD DETAIL @ MUDROOM DOOR 1 1/2" = 1'-0" 7 FOUNDATION DETAIL @ MAIN FLOOR PATIO @ GRADE No. Revision Date Revision Description DRB APPROVED 8/21/2014 12:00:00 AM