HomeMy WebLinkAboutDRB140314_Leever Residence_A6-5 - DETAILS_1410964020.pdfWOOD SIDING OR WOOD TRIM
(LOCATIONS RE: ELEVATIONS)
(5) 2X6 POST RE:
STRUCT
1/2" STEEL PLATE LAG
BOLTED TO (5) 2X6 POST
RE: STRUCT
4"
3"
1"
8X8 WOOD STRUT W/ KNIFE
PLATE CONNECTION TO WALL
W/ SURFACE MOUNTED THRU-
BOLTS RE: STRUCT
4"
1' - 4"
LINE OF KNIFE PLATE INSIDE
WOOD STRUT
*NOTE - KNIFE PLATE IS SHOWN
DIAGRAMMATICALLY RE: STRUCT
FOR ACTUAL KNIFE SIZES AND
REQUIRED BOLT PATTERN
& ELEV.
RE: SECTIONS
WRAP KNIFE PLATE W/ICE AND
WATER SHIELD FOR 3/4" DEPTH OF
SIDING. PROVIDE SEALANT JOINT
BETWEEN WOOD AND KNIFE PLATE -
PAINT KNIFE PLATE TO MATCH
WINDOW COLOR
CORNER TRIM @ SIM. CONDITION
3 1/2"
STEEL I-BEAM RE: STRUCT.
KNIFE PLATE THROUGH BOLTED TO
JOISTS RE:STRUCT.
6X10 JOIST RE:STRUCT.
SHIM RIPPED AT 1/8" PER 1'-0"
3/4" PLYWOOD SLOPED AT 1/8"
PER 1'-0"
W.P. MEMBRANE RE: SPEC.
DRAINAGE BOARD SLOPES AT
1/8" PER 1'-0"
3 1/2" L X 3 1/2" W X 1/2" T STEEL PLATE
PAINTED TO MATCH WINDOW COLOR
LAG BOLTED THROUGH TO END OF
JOIST
W.P. MEMBRANE ADHERES TO COPPER
FLASHING WHICH EXTENDS OVER EDGE
WITH A DRIP EDGE AS SHOWN
4 1/2"
3 3/4" 1/4"
4"
9 1/2" L X 9 1/2" W X 1/2" T STEEL TOP PLATE WELDS
TO STEEL COLUMN RE: STRUCT.
2X6 T&G DECKING
STEEL ANGLE
CUSTOM PFSM
GUTTER RE: SPEC
PFSM DOWNSPOUT RE: SPEC PIPE TO DAYLIGHT
4" STONE ASSEMBLY- APPROX 1" OF STONE OVER
1" OF GROUT OVER 2" CONC. SLAB WITH RADIANT
TUBING AND WELDED WIRE MESH. ATTACH
TUBING TO MESH.
3' - 8 1/4"
3' - 6 1/2" 2 7/8"
2 7/8"
1 5/8"
COUNTER SINK THRU-BOLTS
4 1/4"
PAINTED TO MATCH WINDOW COLOR 3 1/2" H X 1
1/2" W X 3/8" T STEEL WELDED TO TOP
STANCHIONS WITH TOP GRINDED TO 30 DEGREE
ANGLE AND BOTTOM NOTCHED OUT WITH A 3/8" X
1 3/4" SLOT TO ACCEPT STANCHION
CONT. PAINTED TO MATCH WINDOW COLOR 3" W X
1/2" THICK STEEL PLATE AT 30 DEGREES ANGLE
CENTERED AND WELDED TO PLATE BELOW
3/8"
PAINTED TO MATCH WINDOW COLOR 1 1/2"
W X 3/8" T STEEL TOP STRAP
PAINTED TO MATCH WINDOW COLOR 1 1/2" W
X 3/8" T STEEL BOTTOM STRAP
9" 4" 2' - 8" 6"
T.O. FINISHED FLOOR
PAINTED TO MATCH WINDOW COLOR 3/8"
RODS
4" TYP.
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1 1/2" = 1'-0"
7/28/2014 12:16:37 PM
A6.5
DETAILS
AC
HB, SLJ
LEEVER RESIDENCE
7-28-14
5087 Main Gore Drive North, Vail CO
Subdivision: Bighorn 5th Addition Block: 1 Lot: 2
FINAL DRB SUBMITTAL
1 1/2" = 1'-0"
1
STRUT DETAIL @ WOOD SIDING
1 1/2" = 1'-0"
2
HANDRAIL DETAIL @ MASTER BEDROOM
DECK
No. Revision Date
Revision
Description
DRB
APPROVED
8/21/2014 12:00:00 AM