HomeMy WebLinkAboutDRB140314_Leever Residence_A8-1 - WINDOW AND DOOR DETAILS_1410964020.pdfWINDOW RE: WINDOW SCHEDULE
WINDOW SET IN BED OF SEALANT OVER W.P. MEMBRANE
TYP. WOOD SIDING WALL ASSEMBLY
1/2" PLYWOOD OR OSB
SHEATHING RE: STRUCT.
BUILDING PAPER RE: SPEC.
LAP WATERPROOF MEMBRANE
OVER BLDG. PAPER AND UNDER
WINDOW SILL
3X3 WOOD SILL WITH
SLOPED TOP RE: SPEC
WOOD SIDING RE: SPEC &
ELEVATIONS
GRID
LINE
INTERIOR
EXTERIOR
SEE SPEC. & A8.0 FOR TRIM
SIZING
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
WINDOW RE: WINDOW SCHEDULE
FILL W/ EXPANDING SPRAY FOAM
INSULATION AND SHIM AS REQ'D
TYP. WOOD SIDING WALL ASSEMBLY
1/2" PLYWOOD OR OSB
SHEATHING RE: STRUCT.
LAP BUILDING PAPER OVER 1ST LAYER
OF WATERPROOF MEMBRANE BUT HOLD
APPROX. 2" AWAY FROM WINDOW
LAP 2ND LAYER OF WATERPROOF
MEMBRANE OVER 1ST LAYER AND
OVER BUILDING PAPER
3X3 WOOD TRIM RE: SPEC
WOOD SIDING RE: SPEC &
ELEVATIONS
GRID
LINE
INTERIOR
EXTERIOR
LAP 1ST LAYER OF WATERPROOF
MEMBRANE OVER SHEATHING AND
OVER NAILING FLANGE
SEALANT JOINT AND BACKER ROD
SEE SPEC. & A8.0 FOR TRIM
SIZING
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
WINDOW RE: WINDOW SCHEDULE
FILL W/ EXPANDING SPRAY FOAM
INSULATION AND SHIM AS REQ'D
TYP. WOOD SIDING WALL ASSEMBLY
1/2" PLYWOOD OR OSB
SHEATHING RE: STRUCT.
BUILDING PAPER LAPS OVER
TOP OF FLASHING 3" MIN
LAP WATERPROOF MEMBRANE
OVER NAILING FLANGE AND
CONTINUE UP UNDER FLASHING
AND UNDER BUILDING PAPER
3X3 WOOD HEADER TRIM
RE: SPEC
WOOD SIDING RE:
SPEC & ELEVATIONS
GRID
LINE
INTERIOR
EXTERIOR
FLASHING WITH DRIP EDGE RE: SPEC
HEADER RE: STRUCT.
SEE SPEC. & A8.0 FOR TRIM
SIZING
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
WINDOW RE: WINDOW SCHEDULE
WINDOW SET IN BED OF SEALANT
TYP. STUCCO WALL ASSEMBLY
LAP WATERPROOF
MEMBRANE OVER 3D
DRAINAGE MEDIUM OVER
BLDG. PAPER AND UNDER
WINDOW SILL
GRID
LINE
INTERIOR EXTERIOR
1/4" SEALANT JOINT
1/4" GAP
CUSTOM SILL PER INTERIOR DOCUMENTS
TRIM PER INTERIOR DOCUMENTS
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
WINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
TYP. STUCCO WALL ASSEMBLY
LAP BUILDING PAPER OVER 1ST
LAYER OF WATERPROOF MEMBRANE
LAP 2ND LAYER OF WATERPROOF
MEMBRANE OVER 1ST LAYER AND
OVER BUILDING PAPER
GRID
LINE
INTERIOR
EXTERIOR
LAP 1ST LAYER OF WATERPROOF
MEMBRANE OVER SHEATHING AND
OVER NAILING FLANGE
1/4" SEALANT JOINT AND BACKER ROD
TRIM PER INTERIOR DOCUMENTS
3D DRAINAGE MEDIUM LAPS OVER WATERPROOF
MEMBRANE AND BUILDING PAPER
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
WINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION
AND SHIM AS REQ'D
TYP. STUCCO WALL ASSEMBLY
3D DRAINAGE MEDIUM
OVER BUILDING PAPER
LAPS OVER TOP OF
FLASHING 1 1/2" MIN
LAP WATERPROOF MEMBRANE
OVER NAILING FLANGE AND
CONTINUE UP UNDER FLASHING
AND UNDER BUILDING PAPER
GRID
LINE
INTERIOR
EXTERIOR
HEADER RE: STRUCT.
PFSM FLASHING TO MATCH
WINDOW COLOR
TRIM PER INTERIOR DOCUMENTS
PROVIDE WEEP SCREED
WINDOW RE: WINDOW SCHEDULE
WINDOW SET IN BED OF SEALANT
OVER W.P. MEMBRANE
TYP. EXT. STONE SIDING WALL
ASSEMBLY PER 1/A6.1
1/2" PLYWOOD OR OSB SHEATHING RE:
STRUCT.
30 # BUILDING PAPER RE: SPEC.
LAP WATERPROOF MEMBRANE
OVER BLDG. PAPER AND UNDER
WINDOW SILL
2" STONE SILL SLOPED TO DRAIN @
10% MIN.
GRID
LINE
INTERIOR
EXTERIOR
SEE SPEC. & A8.0 FOR TRIM SIZING
PROVIDE CAULK JOINT BETWEEN WINDOW
FRAME AND R.O. @ INTERIOR TYP.
EXTERIOR
INTERIOR
CUSTOM DOOR STILE SEE
A8.0 FOR ELEVATION
CUSTOM MADE WOOD DOOR JAMB
TO DIMENSIONS SPECIFIED
(1) 1 3/4" X 5.5" LVL MICROLAMS
9/16" WOOD TRIM
WINDOW HEAD SECTION OUTLINE BEYOND
TO SHOW ADJACENT SIDE LIGHT CONDITION
ICE & WATER SHIELD
CONTINUOUS
UNDER SILL @ UPPER
WINDOW LAPS OVER DOOR
FRAME BELOW
SEALANT 2 3/4" 3/16" 3 7/8"
3/16"
2 5/8"
2 15/16" 3/8" GRID
LINE
0"
IN-FILL W/ EXPANDING SPRAY FOAM
INSULATION AND SHIM AS REQ.
2 1/8" 1"
3/8"
1 1/8" 1 9/16" 2 1/2"
TRIM TO ALIGN W/ TRIM @
ADJACENT WINDOW
CONDITION
EXTERIOR
INTERIOR
9/16" WOOD TRIM
WINDOW HEAD SECTION
ICE & WATER SHIELD CONTINUOUS
UNDER SILL @ UPPER WINDOW LAPS
OVER WINDOW NAILING FLANGE @
LOWER WINDOW
SEALANT 2 3/4"
3/8"
3/8"
GRID
LINE
(1) 1 3/4" X 5.5" LVL MICROLAMS RIPPED
1/2"
1/2" PLYWOOD FILLER ATTACHED TO
WINDOW FRAME SIDE OF HEAD
ONLY
CUSTOM 4/4" WOOD JAMB
EXTENSION
CUSTOM 4/4" WOOD JAMB EXTENSION
5/8" X 5/8" WOOD TRIM
3/16"
3 7/8"
3/16" 5/8" X 5/8" WOOD TRIM
3"
IN-FILL W/ EXPANDING SPRAY
FOAM INSULATION AND SHIM
AS REQ'D
FILL ALL VOIDS W/ SPRAY
FOAM INSULATION
EXTERIOR
INTERIOR
CUSTOM DOOR STILE SEE
A8.0 FOR ELEVATION
CUSTOM WOOD DOOR JAMB
TO DIMENSIONS SPECIFIED
(1) 1 3/4" X 5.5" LVL MICROLAMS
9/16" WOOD TRIM CONTINUOUS
@ WINDOW TO WINDOW
CONDITION ABOVE
SEALANT
2 3/4"
2 5/8"
2 15/16" 3/8" GRID
LINE
SPRAY FOAM GAP AND
SHIM AS REQ. TYP.
CUSTOM 4/4" WOOD JAMB
EXTENSION W/ 5/8" 5/8" WOOD TRIM
1 9/16"
3/8"
3/16" 3 7/8" 3/16"
1 1/8"
2 1/2"
EXTERIOR
INTERIOR
(1) 1 3/4" X 5.5" LVL MICROLAMS
9/16" WOOD TRIM RE: SPEC
SEALANT
2 3/4"
3/8" GRID
LINE
1/2" PLYWOOD FILLER
ATTACHED TO DOOR FRAME
SIDE OF MICROLAM ONLY
3/8"
CUSTOM 4/4 WOOD JAMB
EXTENSION
3/16" 3 7/8" 3/16"
5/8" X 5/8" WOOD TRIM
3"
IN-FILL W/ EXPANDING
SPRAY FOAM INSULATION
TYP.
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
3" = 1'-0"
7/28/2014 12:17:17 PM
A8.1
WINDOW
AND DOOR
DETAILS
AC
HB, SLJ
LEEVER RESIDENCE
7-28-14
5087 Main Gore Drive North, Vail CO
Subdivision: Bighorn 5th Addition Block: 1 Lot: 2
FINAL DRB SUBMITTAL
3" = 1'-0"
1
WINDOW SILL @ WOOD SIDING
3" = 1'-0"
2
WINDOW JAMB @ WOOD SIDING
3" = 1'-0"
3
WINDOW HEAD @ WOOD SIDING
3" = 1'-0"
4 WINDOW SILL @ STUCCO VENEER
3" = 1'-0"
5 WINDOW JAMB @ STUCCO VENEER
3" = 1'-0"
6 WINDOW HEAD @ STUCCO VENEER
3" = 1'-0"
7 WINDOW SILL @ STONE VENEER
3" = 1'-0"
8
FRONT ENTRY WINDOW DETAIL - DOOR
HEAD TO WINDOW SILL
3" = 1'-0"
9
FRONT ENTRY WINDOW DETAIL -
WINDOW HEAD TO WINDOW SILL
3" = 1'-0"
10
FRONT ENTRY WINDOW DETAIL - DOOR
TO WINDOW JAMB
3" = 1'-0"
11
FRONT ENTRY WINDOW DETAIL -
WINDOW TO WINDOW JAMB
No. Revision Date
Revision
Description
DRB
APPROVED
8/21/2014 12:00:00 AM