Loading...
HomeMy WebLinkAboutDRB140356_E2.1_1408984560.pdf1/4" = 1'-0" 1/4" = 1'-0" Dimmer Switch Under Counter Strip Light Smoke Alarm Wall Sconce 3-Way Switch Single Switch Telephone Outlet Television Outlet Quad Outlet Duplex Outlet Switched Outlet Floor Outlet Exhaust Fan Surface Mounted Fixture Waterproof Light Recessed Can - Directional Recessed Can 4-Way Switch Pendant Light Fixture 1x4 Fluorescent fixture Track Lighting Junction Box 2x4 Fluorescent fixture All lighting, outlet and smoke alarm quantity and location to meet applicable codes. All fixtures noted as O.S. are to be supplied by owner. Motion Detector Switch Monopoint Ceiling Fan Chandelier Existing Junction Box Existing Fixture Thermostat REFLECTED CEIL. / ELEC. N O T E S 1. Reuse existing outlets, switches, fixture junction boxes and circuit wiring where allowable by code and as approved by architect. All wiring must be MC type. 2. Spacing of outlets required by the adopted IBC/IEC may require additional outlets. Contractor to verify spacing with electical code. All new wall outlets shall match height of existing outlets (18" above floor +/-) unless otherwise noted. 3. Fixtures, switches and outlets shown are called out by general type unless a schedule is attached. Architect to provide specifications at future submittal to contractor. 4. Anaylisis of the capacity of the existing panels and service to accomodate lighting layout changes shall be the responsibility of the contractor's electrical engineer. 5. Actual soffit heights may vary according to venting and electrical requirements as well as actual height of existing soffits that are to be extended. Verify contractor proposed final ceiling heights with Architect if different from those noted prior to construction. 6. Light fixtures shall be located where dimensioned or centered in soffited ceiling areas and between tees. New soffiting/ceiling framing shall take into account desired fixture location. Where conflicts with framing occur, notify Architect 7. All bathroom fans and can lights in all soffits and ceilings are required to have accessories, that when installed with the fan or light make up a UL approved 1-hr assembly. Other ceiling elements shall utilize standard j-boxes that meet 1-hr requirements. 8. 75% of new fixtures shall be high efficacy to meet Town of Vail's adherence with IECC requirements. C KRUEGER ARCHITECTURE & DESIGN PO box 8332 Avon CO 81620 970.390.0968 pavan@kruegerarchitecture.com COPYRIGHT 2014 KRUEGER ARCHITECTURE & DESIGN E2.1 ELECTRICAL/ RCP PLANS DRB APPROVED 8/25/2014 12:00:00 AM