HomeMy WebLinkAboutDRB140452_Leever Residence_A10-0 - ELECTRICAL SCHEDULE & NOTES_1414505040.pdfTELEPHONE/
DATA
GFI
WP
220
TV
FAN
3
D
DUPLEX OUTLET
SWITCHED OUTLET (ONE SIDE ONLY)
GROUND FAULT INTERRUPT OUTLET
WATER PROOF GFI OUTLET
220 OUTLET
FLOOR MOUNTED DUPLEX
TELEVISION / PROVIDE 2 RG-6 AND 2 CAT-V
2 CAT V TELEPHONE
RECESSED DIRECTIONAL DOWN LIGHT
FLAT OR SLOPED CEILING
RECESSED 4-LIGHT MULTIPLE
DIRECTIONAL DOWN LIGHT
SURFACE MOUNTED FIXTURE @ WALL
WALL MOUNTED UP LIGHT FIXTURE
WALL MOUNTED STEP LIGHT FIXTURE
SURFACE MOUNTED FLORESCENT
SURFACE MOUNTED ON CEILING
LED LIGHTING UNDER CABINET LIGHTING
SURFACE MOUNTED FLORESCENT MOUNTED ABOVE DOOR HEAD
JUNCTION BOX
EXHAUST FAN
SWITCH
3-WAY SWITCH / 4-WAY SWITCH
DIMMER SWITCH (MAY BE SHOWN AS 3-WAY)
MONOPOINT
J-BOX
MOTORIZED SHADE W/ BUILT-IN POCKET
TRU- FIG DUPLEX OUTLET
TF
DUPLEX OUTLET W/ (2) USB PORTS
USB
GENERAL NOTES:
1. LOCATION OF OUTLETS AND OTHER ELECTRICAL DEVICES IS DIAGRAMMATIC -- ACTUAL PLACEMENT OF
ELEMENTS, WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL,
STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES.
2. OUTLETS TO BE LOCATED HORIZONTAL AND CENTERED IN THE BASE BOARD, AND SWITCHES 42"
ABOVE FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED. AT LOCATIONS WHERE THIS IS NOT
POSSIBLE, CONSULT THE ARCHITECT.
3. PROVIDE SMOKE DETECTORS AS REQUIRED. SMOKE DETECTORS WILL BE CONNECTED TO THE ALARM
SYSTEM
4. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. COORDINATE FIXTURE LOCATION WITH STRUCTURE
AND TO ALIGN AND CENTER FIXTURES AS CLOSE AS POSSIBLEPROVIDE GFI OUTLET IN EVERY VANITY
@ ONE SINK IN CABINET, EXCEPT FOR POWDER ROOMS.
5. COORDINATE SWITCHED OUTLETS LOCATIONS AT VANITY WALLS AND FLOORS WITH FURNITURE PLANS
AND INTERIOR DOCUMENTS
6. PROVIDE CARBON MONOXIDE DETECTORS THROUGHOUT THE HOUSE PER R315. CARBON MONOXIDE
DETECTORS WILL BE CONNECTED TO THE ALARM SYSTEM.
7. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH CENTERLINE AT 46" AFF EXCEPT AS NOTED. VERIFY
LOCATION & HEIGHT WITH OWNER
8. VERIFY ALL APPLIANCE ELECTRICAL LOADS WITH OWNER SPECS.
9. PROVIDE POWER AS REQUIRED PER MECHANICAL CONTRACTOR AND SPEC.
10. PROVIDE POWER TO HOT TUB PER SPA TO BE USED
11. COORDINATE OUTLET W/ FURNITURE PLANS PER OWNER
12. COORDINATE KITCHEN POWER STRIP W/ OWNER AND PER SPEC - POWER STRIP TO BE LOCATED ON
UNDERSIDE OF CABINET AT JUNCTURE WITH WALL
13. PROVIDE J-BOX FOR HEAT TAPE LOW ON WALL @ ALL DOWNSPOUT LOCATIONS
14. PROVIDE LIGHTING CONTROL SYSTEM AND LOW VOLTAGE CONTROL SYSTEM PER OWNER'S
DIRECTION.
15. PROVIDE UNDERWATER WATER FEATURE LIGHTS AS SHOWN ON THE WATER FEATURE FLOOR PLAN -
PENDING MORE INFORMATION - PLAN FOR POWER IN WATER FEATURE.
16. ALL WINDOWS TO HAVE LUTRON MOTORIZED SHADE HAVE ADJ. TO WINDOW. SCREEN POCKET SIZE
IS SHOWN IN WINDOW DETAILS. THE SYMBOL 64 INDICATES LUTRON 64 SERVERS SHADE. THE SYMBOL
100 INDICATES LUTRON 100 SERVERS SHADE. ALL WINDOW HEADERS TO BE FRAMED WITH 5 1/4" X 4
1/4" CLEAR POCKET. SEE DETAILS ON A8.1.
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
9/26/2014 4:39:55 PM
A10.0
ELECTRICAL
SCHEDULE
AND NOTES
AG
HB
LEEVER RESIDENCE
9-29-14
5087 Main Gore Drive North, Vail CO
Subdivision: Bighorn 5th Addition Block: 1 Lot: 2
CHANGE TO
APPROVED PLANS
1/4" = 1'-0"
ELECTRICAL LEGEND
Lighting Fixture Schedule
Type Mark Type Manufacturer Model Type Comments Count
A 3" RECESSED CAN LIGHT -
ADJUSTABLE
HALO H38LVICAT 3004WHH WHITE TRIM W/ HAZE REFLECTOR 123
A2 3" RECESSED CAN LIGHT - GIMBAL HALO H38LVICAT 3009WHWB WHITE W/ WHITE BAFFLE 25
A3 3" RECESSED CAN LIGHT -
REGRESSED LENS ADJUSTABLE
REFLECTOR SHOWER LIGHT
HALO H38LVICAT 3007WHC WHITE W/ SPECULAR CLEAR REFLECTOR 6
A4 3" RECESSED CAN LIGHT - WOOD
CEILING ADJUSTABLE
HALO H38LVICAT 3004TBZ TUSCAN BRONZE W/ TUSCAN BRONZE REFLECTOR 11
A5 3" RECESSED CAN LIGHT - WOOD
CEILING GIMBAL
HALO H38LVICAT 3009TBZBB TUSCAN BRONZE W/ BLACK BAFFLE 3
A6 CABINET DOWNLIGHT HAFELE 830.64.231 SURFACE MOUNTED LED IN CABINET PUCK LIGHT W/ BRUSHED STEEL
FINISH
1
B EXTERIOR SCONCE HEVI LITE HL-340-LED BZ - POWDER COAT BRONZE 8
D DECORATIVE @ LIVING ROOM CHANDELIER RE: INTERIOR DESIGN DOCUMENTS 1
D2 DECORATIVE @ DINING ROOM DINING ROOM DECORATIVE RE: INTERIOR DESIGN DOCUMENTS 1
D3 DECORATIVE @ ENTRY CEILING MOUNTED DECORATIVE RE: INTERIOR DESIGN DOCUMENTS 1
D4 POWDER ROOM DECORATIVE WALL MOUNTED BATHROOM SCONCE RE: INTERIOR DESIGN
DOCUMENTS
2
D5 MASTER BATHROOM DECORATIVE WALL MOUNTED BATHROOM SCONCE RE: INTERIOR DESIGN
DOCUMENTS
6
D6 BATHROOM #2 DECORATIVE WALL MOUNTED BATHROOM SCONCE RE: INTERIOR DESIGN
DOCUMENTS
2
D7 BATHROOM #3 DECORATIVE WALL MOUNTED BATHROOM SCONCE RE: INTERIOR DESIGN
DOCUMENTS
2
D8 GUEST BATHROOM SCONCE WALL MOUNTED BATHROOM SCONCE RE: INTERIOR DESIGN
DOCUMENTS
2
D9 BONUS ROOM BATHROOM SCONCE WALL MOUNTED BATHROOM SCONCE RE: INTERIOR DESIGN
DOCUMENTS
2
D10 BONUS ROOM BUNK BED
DECORATIVE
WALL MOUNTED BUNK ROOM SCONCE RE: INTERIOR DESIGN
DOCUMENTS
4
F SURFACE MOUNTED LIGHT CHANNEL EDGE LIGHTING LCSM-12V Mounted above door header with motion sensor 3
G SURFACE MOUNTED FIXTURE TECH LIGHTING 700CQ-L-S-LED CIRQUE CEILING MOUNTED FIXTURE W/ SATIN NICKEL TRIM 19
H 1X4 FLORESCENT - HIGH EFFICACY 8
J J-BOX CEILING FAN RATED 4
M MONOPOINT SURFACE MOUNTED HEVI LITE HL-384-BZ INTEGRAL LOW VOLTAGE TRANSFORMER, 50W MR-15 BI-PIN HALOGEN,
BRONZE
12
N UNDER CABINET LED ROPE LIGHT-
HIGH EFFICACY
JESCO FLEX- UPHO LED LINEAR LIGHTING STRIP, 18 LED LAMPS PER 1' 4
O LANDSCAPE BOLLARD LIGHT SLV LIGHTING 4229410U RUSTY SLOT 50 10
O2 EXTERIOR STEP LIGHT SLV LIGHTING 2229250U BRICK MESH STAINLESS STEEL 3
P PENDANT LIGHT @ KITCHEN RE: INTERIOR DESIGN DOCUMENTS 4
P2 PENDANT LIGHT @ BREAKFAST
AREA
RE: INTERIOR DESIGN DOCUMENTS 1
Q INTERIOR STEP LIGHT WAC LIGHTING WL-LED200TR WHITE W/ WHITE FINISH 6
T LINE VOLTAGE TRACK LIGHTING
SYSTEM
LIGHTOLIER FXESR TANGENT LOW PROFILE RING 120V, W/ TANGENT SUSPENSION
NON-POWERED CABLE KIT IN SILVER FINISH
2
U RECESSED FLOOR UP LIGHT WINONA LA-0-12V-L2-BRS-FO-SHO-
STD
WINSCAPE LAUREL 2
Grand total: 278
LIGHTING EFFICACY CALCULATIONS:
PER SECTION R404.1 IN THE 2012 IECC A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS, WITH THE EXCEPTION
THAT LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO UTILIZE HIGH EFFICACY LAMPS.
506 TOTAL FIXTURES ARE PROPOSED WITH 421 BEING LOW VOLTAGE, PER THE EXCEPTION ABOVE 85 FIXTURES WILL BE USED IN THE CALCULATION. 2,351 LAMPS ARE PROPOSED IN
PROJECT. 2,327 LAMPS ARE HIGH EFFICACY.
2327/2351=.989
98% OF THE LAMPS IN THE HOUSE ARE HIGH EFFICACY WHICH EXCEEDS THE REQUIREMENT OF 75% IN R404.1 IN THE 2012 IECC.
No. Revision Date
Revision
Description
DRB
APPROVED
10/21/2014 12:00:00 AM