HomeMy WebLinkAboutDRB140452_Leever Residence_A10-1 - MAIN LEVEL RCP_1414505040.pdfSWITCHES NOT SHOWN THIS LEVEL. SWITCHES TO
BE COORDINATED W/ AV CONSULTANT AND
LIGHTING CONTROL SYSTEM. SWITCHES TO BE
PLACE PER CODE
A4.1 1
A4.1 2
A4.2
2
A4.2
1
A4.3
3
A4.3
2
1
A5.1
2
A5.1
3
A5.1
1
A5.2
3
A5.2
2
A5.2
FAMILY ROOM
KITCHEN
BREAKFAST
AREA
LIVING ROOM
DINING ROOM
ENTRY
CRAWLSPACE
ACCESS
PANTRY
POWDER
FAMILY OFFICE
SKIP'S OFFICE
LAUNDRY
MECH.
MUD ROOM
GARAGE
A4.3
1
1' - 6"
4' - 0" 4' - 0" 4' - 0"
1
A5.3
A4.3
4
A4.3
5
A4.4
6
A4.4
1
A4.4
3
A4.4
9
A4.4
5
2
A5.3
4
A5.2
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
1A
1A
1B
1B
1C
1C
1D
1D
1AA
1AA
A A
B B
C C
D D
F F
G G
H H
AA
BB
CC
DD
EE
AAA
12' - 9" 5' - 3" 10' - 9" 7' - 6" 7' - 6" 13' - 6" 1' - 6" 3' - 0"
12' - 9" 5' - 3" 10' - 9" 7' - 6" 7' - 6" 13' - 6" 1' - 6" 3' - 0"
11' - 8 1/2"
23' - 3 1/2"
6' - 0"
11' - 8 1/2"
23' - 3 1/2"
6' - 0"
3' - 0"
18' - 0" 2' - 0" 11' - 9" 9' - 6" 9' - 0" 3' - 0"
18' - 0" 2' - 0" 11' - 9" 9' - 6" 9' - 0" 1' - 9"1' - 10"23' - 6"2' - 6"
10' - 8 1/2"
2" / 12"
A4.4
7
A4.4
8
D
A4 A4
A4
A4
A4 A4
E E
B
B
B
B
B
B
B
B
A2
A
A
D2
F
A A
A
A A
A
A2 A A
P
P
P
A4 A4 A4
A4
A4
A5 A5
A
A
A
A
A
A
A
A A A
A
A
A
A
A
A
A
A
A
A
A
A
A2
A2
A
A
A A
P2
A2
A2
A2
A2
A2
A2
A2
A A
A A
A A
A
A
A
A
H
H
H
H
H
H
H
FAN
WASHER
220
DRYER
GARBAGE
DISPOSAL
TRASH
COMPACTOR
FR
HOOD
IRON +42
1' - 2 3/4"
D4
D4
10' - 8 3/8"
11' - 3 7/8"
A5
A2
A2
P
A6
M
M
M M
A
A
RECESSED TYPE U
FLOOR LIGHT BELOW
RE: A3.1
A2
D3
G G
A2
A2
A2
G
G
G
G
G
G
H
DW
A
GFI
Q
Q
Q
Q
UP
SEE LEVEL ABOVE FOR
CLG LIGHTS @ STAIR
8X12
8X12
8X12
9' - 6"
GARAGE
DOOR
GARAGE
DOOR
A BO VE
C OU NTER
ABOVE
CO UNTER
GFI IN
ISLAND
TVABOVE
COUNTER TELEPHONE/DATA
ABOVE
COUNTER
ABOVE
COUNTER
FR
FR
GFI
GFI
M M M M
WP WP
GASWP
LANDSCAPE
LIGHTING BASEBOARD
BASEBOARD
BASEBOARD BASEBOARD
BASEBOARD HEAT TAPE
WP
WP
HEAT TAPE
WP
M
CONDUIT FOR FUTURE
220 POWER FOR
FUTURE HOT TUB
LANDSCAPE
LIGHTING
H EAT TAPE
WP
UPPER LEVEL
LIGHTS
HEAT TAPE
HEAT TAPE
PROVIDE POWER
FOR MECHANICAL
EQUIP. AS REQ'D
TELEPHONE/
DATA
TV
ABOVE
COUNTER
ABOVE
COUNTER
TV
GFI
MICRO
OVEN
GFI
P
DW
GARBAGE
DISPOSAL GFI
GFI
GFI
OVEN
220 GAS N
N
N
SWITCHED OUTLET FOR
TRANSFORMER FOR
UNDER CABINET LIGHTS
ABOVE
COUNTER
4' - 3 15/16" 4' - 3 15/16" 4' - 3 15/16" 4' - 3 15/16"
4 3/4" A6.7
7
A8.0 1
M
M
M
TVTV
FAN
9' - 0"
9' - 0"
A
A TELEPHONE/
DATA
TELEPHONE/
DATA
G
G
DN TO CRAWL
SPACE LIGHTS
TV GFI
TELEPHONE/
DATA
IN CABINET
TV
TELEPHONE/
DATA
PROVIDE POWER, TV & PHONE @
BACK OF CABINET. COORDINATE
W/ OWNER & AV CONSULTANT
TV & POWER IN RECESS @ APPROX 48" O.C.
- SEE INT. ELEVATION. COORDINATE
HEIGHTS & LOCATION OF TV & BRACKET W/
OWNER & AV CONSULTANT
9' - 0"
GENERAL NOTES:
1) EXTERIOR LIGHTING:
1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 26 LIGHTS ARE
ALLOWED. 26 EXTERIOR LIGHTS MORE THAN 18" ABOVE GRADE
ARE PROPOSED. SEE ELECTRICAL PLANS FOR TYPE, LOCATION
AND NUMBER OF FIXTURES.
(6) TYPE A4 LIGHTS PROVIDED @ THIS LEVEL
(12) CEILING MOUNTED TYPE M LIGHTS PROVIDED @ THIS LEVEL
(8) TYPE B LIGHTS PROVIDED 7' - 6" ABOVE F.F. @ THIS LEVEL
________________________________________
26 TOTAL EXTERIOR LIGHTS MOUNTED MORE THAN 18" ABOVE
GRADE AT THIS LEVEL
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
9/26/2014 4:40:06 PM
A10.1
MAIN LEVEL
RCP
AC
HB, SLJ
LEEVER RESIDENCE
9-29-14
5087 Main Gore Drive North, Vail CO
Subdivision: Bighorn 5th Addition Block: 1 Lot: 2
CHANGE TO
APPROVED PLANS
1/4" = 1'-0"
1
MAIN LEVEL REFLECTED CEILING PLAN
0' 2' 4' 8' 16'
No. Revision Date
Revision
Description
1 9-29-14 CHANGE TO
APPROVED
PLANS
REVISED TYPE A4 CEILING MOUNTED FIXTURES
@ ENTRY ROOFS, UNDERSIDE OF MASTER
BEDROOM DECK & LIVING ROOM SOFFIT TO
TYPE M FIXTURES.
DRB
APPROVED
10/21/2014 12:00:00 AM