HomeMy WebLinkAboutDRB140452_Leever Residence_A10-2 - UPPER LEVEL RCP_1414505040.pdfSWITCHES NOT SHOWN THIS LEVEL. SWITCHES TO
BE COORDINATED W/ AV CONSULTANT AND
LIGHTING CONTROL SYSTEM. SWITCHES TO BE
PLACE PER CODE
A4.1
1
A4.1 2
A4.2
2
A4.2
1
A4.3
3
A4.3
2
1
A5.1
2
A5.1
3
A5.1
1
A5.2
3
A5.2
4
A5.1
2
A5.2
MASTER
BEDROOM
MASTER BATH MASTER CLOSET
BEDROOM #2
CLOSET # 2
BATH #2
BATH #3
CLOSET #3
BEDROOM #3
GUEST BEDROOM
GUEST CLOSET
LAUNDRY/
STORAGE
GUEST BATH
BONUS ROOM
BONUS ROOM
BATH
1 1/2" / 12"
1 1/2" / 12"
1 1/2" / 12"
2" / 12" 1 1/2" / 12"
1 1/2" / 12"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
10' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
1 1/2" / 12"
A4.3
1
1
A5.3
A4.3
4
A4.3
5
A4.4
1
A4.4
2
A4.4
4
A4.4 3
A4.4
5
2
A5.3
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
1A
1A
1B
1B
1C
1C
1D
1D
A A
B B
C
C
D
D
F F
G G
H H
AA
BB
CC
DD
EE
12' - 9" 5' - 3" 10' - 9" 7' - 6" 7' - 6" 13' - 6" 1' - 6" 3' - 0"
12' - 9" 5' - 3" 10' - 9" 7' - 6" 7' - 6" 13' - 6" 1' - 6" 3' - 0"
11' - 8 1/2"
23' - 3 1/2"
6' - 0"
11' - 8 1/2"
23' - 3 1/2"
6' - 0"
3' - 0"
18' - 0" 2' - 0" 11' - 9" 9' - 6" 9' - 0" 3' - 0"
18' - 0" 2' - 0" 11' - 9" 9' - 6" 9' - 0" 1' - 9"1' - 10"23' - 6"2' - 6"
E E
Q
STEP LIGHT
A
A
A
A
A
A
A
A A3
D7
D7
A3
A
A
D6
D6
D8
D8
FAN
FAN
FAN
9' - 0"
A A
A A A
D9
D9
A3
A
A
A A3
A2
A A A2 A2
A A2
A A2
A2 A2
J
D5 D5 D5 D5
A3
FAN
J
J
A
A
A
A
A
A
A
A3
A
A
A
A
A
J
A
A
A A
A
A
A
A
A
A A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A WASHER
220
DRYER
A2
D5
D5
G
G G
G
G
G G
G
G
FAN
T
T
A
SCONCE @ LOWER BUNK AND AT
@ UPPER BUNK. COORDINATE &
VERIFY HEIGHTS RE: INT. EACH TO
HAVE INDIVIDUAL SWITCH ON
LIGHT OR WALL.
D10
D10
(2)
(2)
Q
DN
8' - 0"
12' - 0"
F
TV SHOWN ABOVE FIREPLACE
PROVIDE RECESS BEHIND TV FOR
MOUNTING BRACKET PROVIDE
POWER & TV OUTLET IN RECESS
TV
TV
TV
TV
TV
IN
DRAWER
F
UNDER
SINK
UNDER
SINK
UNDER
SINK
UNDER
SINK
GFI
DN TO SWITCH
@ MAIN LEVEL
GFI
GFI
FAN TOWEL BAR
UNDER
SINK
GFIABOVE
COUNTER
GFI
ABOVE
COUNTER
GFI
GFI
FR
MICRO
GFI
GFI
UPPER ROOF
TELEPHONE/
DATA
FAN
FAN
TELEPHONE/
DATA
TELEPHONE/
DATA
EQ EQ
TELEPHONE/
DATA
TELEPHONE/
DATA
W.P.
TELEPHONE/
DATA
A A
A
A
A
A
9' - 0"
ROOF JOG
ABOVE TELEPHONE/
DATA
ABOVE
COUNTER
FAN
1 1/2" / 12"
FAN
TELEPHONE/
DATA
ABOVE
COUNTER
8 3/4" X 21" GLULAM
RE: STRUCT.
TV
PROVIDE POWER &
TV @ 48" ABOVE F.F.
SCONCE @ LOWER BUNK AND AT
@ UPPER BUNK. COORDINATE &
VERIFY HEIGHTS RE: INT. EACH TO
HAVE INDIVIDUAL SWITCH ON
LIGHT OR WALL.
GENERAL NOTES:
1) EXTERIOR LIGHTING:
1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 26
LIGHTS ARE ALLOWED. 26 EXTERIOR LIGHTS MORE THAN
18" ABOVE GRADE ARE PROPOSED. SEE ELECTRICAL
PLANS FOR TYPE, LOCATION AND NUMBER OF FIXTURES.
(0) TYPE A4 LIGHTS PROVIDED @ THIS LEVEL
(0) TYPE M LIGHTS PROVIDED @ THIS LEVEL
(0) TYPE B LIGHTS PROVIDED @ THIS LEVEL
________________________________________
0 TOTAL EXTERIOR LIGHTS MOUNTED MORE THAN 18"
ABOVE GRADE AT THIS LEVEL
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
9/26/2014 4:40:22 PM
A10.2
UPPER
LEVEL RCP
AC
HB, SLJ
LEEVER RESIDENCE
9-29-14
5087 Main Gore Drive North, Vail CO
Subdivision: Bighorn 5th Addition Block: 1 Lot: 2
CHANGE TO
APPROVED PLANS
1/4" = 1'-0"
1
UPPER LEVEL REFLECTED CEILING
PLAN
0' 2' 4' 8' 16'
No. Revision Date
Revision
Description
DRB
APPROVED
10/21/2014 12:00:00 AM