Loading...
HomeMy WebLinkAboutDRB140452_Leever Residence_A4-2 - ELEVATIONS_1414505040.pdfMAIN LEVEL FLOOR PLAN FINISHED FLOOR 8540' - 6" UPPER LEVEL FLOOR PLAN FINISHED FLOOR 8552' - 6" 1 A5.1 4 A5.1 2 A5.2 33' HEIGHT LIMIT ABOVE EXISTING GRADE @ EDGE OF ROOF EXISTING GRADE DIRECTLY BELOW EDGE OF ROOF ABOVE BUILDING HEIGHT 32' - 10 3/16" ABOVE EXISTING GRADE @ UPPER LEVEL ROOF EAVE BUILDING HEIGHT 31' - 11 3/16" ABOVE EXISTING GRADE @ UPPER LEVEL ROOF EAVE 33' HEIGHT LIMIT ABOVE EXISTING GRADE @ EDGE OF ROOF BUILDING HEIGHT 32' - 8 1/8" ABOVE EXISTING GRADE @ UPPER LEVEL ROOF EAVE 1 1 2 2 3 3 4 4 4 5 5 5 6 6 7A 7B 7B 7A 7A 8 8 8 9 9 10 10 11 12 13 13 13 13 13 14 14 14 14 15 15 16 17 18 19 18 19 17 TRUE ELEVATION OBLIQUE ELEVATION SEE SHEET A4.3 1 2 3 4 5 6 7 8 9 3' - 0" 1' - 6" 13' - 6" 7' - 6" 7' - 6" 10' - 9" 5' - 3" 12' - 9" T.O. ROOF @ 8570' - 4 3/8" C 112 D 111 O 116 M 116 R 117 P 117 Q 117 BBB 214 NN 216 DD 125 C 212 D 123 C 123 Y 123 X 123 D 108 MMM 107 N 116 C 208 XX 212 CCC 215 BB 216 A6.5 1 A6.5 1 SIM. A6.5 1 A6.5 1 2 A6.4 2 A6.4 2 A6.4 T.O. ROOF @ 8566' - 7 1/2" 3' - 6 1/2" 2 A6.5 7' - 6" TYP. 9 21 A6.5 3 A6.4 7 3' - 0" 3' - 0" A6.4 6 3' - 0" 3' - 0" 3' - 6" 3' - 6" J-BOX PROVIDE POWER FOR HEAT TAPE @ GUTTER T.O. WINDOW R.O. @ 10' - 0 3/4" T.O. WINDOW R.O. @ 10' - 6 3/4" T.O. WINDOW R.O. @ 9' - 6 3/4" T.O. WINDOW R.O. @ 12' - 2 3/4" T.O. WINDOW R.O. @ 9' - 6 3/4" @ LOWER LEVEL U.N.O. T.O. WINDOW R.O. @ 10' - 6 3/4" T.O. WINDOW R.O. @ 10' - 0 3/4" SEE SHEET A7.1 FOR LIVING ROOM FIREPLACE/CHIMNEY DETAILS SEE SHEET A7.2 FOR MASTER BEDROOM FIREPLACE/CHIMNEY DETAILS OPEN OPEN 22 22 22 A6.4 6 SIM. 2 2 CC 125 STUCCO CONTROL JOINT TYP. MAIN LEVEL FLOOR PLAN FINISHED FLOOR 8540' - 6" UPPER LEVEL FLOOR PLAN FINISHED FLOOR 8552' - 6" 1 A5.1 4 A5.1 2 A5.2 33' HEIGHT LIMIT ABOVE EXISTING GRADE @ EDGE OF ROOF EXISTING GRADE DIRECTLY BELOW EDGE OF ROOF ABOVE 33' HEIGHT LIMIT ABOVE EXISTING GRADE @ EDGE OF ROOF BUILDING HEIGHT 32' - 8 1/8" ABOVE EXISTING GRADE @ UPPER LEVEL ROOF BUILDING HEIGHT 32' - 10 3/16" ABOVE EXISTING GRADE @ UPPER LEVEL ROOF 1 3 2 2 5 5 7A 7B 7B 7A 7A 8 9 8 9 13 14 13 14 17 17 17 18 19 7A OBLIQUE ELEVATION SEE SHEET A4.3 TRUE ELEVATION 1 2 3 4 5 6 7 8 9 3' - 0" 1' - 6" 13' - 6" 7' - 6" 7' - 6" 10' - 9" 5' - 3" 12' - 9" T.O. ROOF @ 8570' - 4 3/8" DD 128 DD 129 DD 130 JJ 131 DD 134 VV 219 VV 220 NN 221 NN 221 NN 222 T.O. ROOF @ 8566' - 7 5/16" T.O. ROOF @ 8567' - 7 9/16" T.O. ROOF @ 8569' - 7 7/8" 23' - 4 3/4" A6.5 1 SIM. 1 A6.4 6 A6.3 6 A6.3 BILCO PRE-MANUFACTURED STAIR & CRAWLSPACE ACCESS DOOR RE: SPEC 25.0° 1' - 9 3/4" J-BOX PROVIDE POWER FOR HEAT TAPE @ GUTTER OUTDOOR BBQ WALL VENT 6 A6.6 T.O. WINDOW R.O. @ 8' - 0 3/4" 3' - 6" 6' - 0" TO T.O. WINDOW R.O. 1' - 8 1/4" T.O. WINDOW R.O. @ 9' - 6 3/4" BOILER FLUES PAINTED BLACK SEE SHEET A7.2 FOR MASTER BEDROOM FIREPLACE/CHIMNEY DETAILS DOWNSPOUT DISCHARGES INTO GUTTER BELOW 6 A8.1 OPEN OPEN DD 000 DD 001 DD 002 1 A6.4 JJ 131 23 GENERAL NOTES: 1) EXTERIOR LIGHTING IS NOTED AS: 2) SEE EXTERIOR MATERIAL AND COLOR INFORMATION SHEET FOR MORE INFORMATION ON COLORS. SEE OUTLINE SPEC AND ARCHITECTURAL FINISH SCHEDULE. 3) ALL SNOW FENCES AT STANDING SEAM ROOF TO BE A DESIGN-BUILD ENGINEERED SYSTEM PER ROOF TYPE AND SLOPE INSTALLED PER MANUFACTURES RECOMMENDATIONS RE: SPEC. 4) ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O. 5) WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH. 6) SEE SHEET A4.1 FOR TYP. MATERIAL CALLOUTS 7) ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO BE PAINTED TO MATCH WINDOW COLOR. MATERIALS 1. STANDING SEAM METAL ROOF- DARK BRONZE COLOR RE: SPEC 2. 6X10 WOOD RAFTERS. RE: STRUCT- COLOR: PORTER STAINS 709 BLACK WALNUT 3. 2X6FASCIA.- COLOR: PORTER STAINS 709 BLACK WALNUT 4. DRY STACKED STONE VENEER- RE: FINISH SCHEDULE & SPEC 5. 1X8 HORIZONTAL WOOD SIDING RE: FINISH SCHEDULE & SPEC 6. VERTICAL RECLAIMED WOOD SIDING RE: FINISH SCHEDULE & SPEC 7. A) STUCCO W/ LIGHT SAND TEXTURE - COLOR #1 B) STUCCO W/ LIGHT SAND TEXTURE - COLOR #2 8. 3X3 WOOD TRIM- COLOR: PORTER STAINS 709 BLACK WALNUT 9. 2X3 WOOD CORNER TRIM 10. T&G CEDAR SOFFIT W/ SEMI-TRANSPARENT STAIN - COLOR: 50% PORTER STAINS 709 BLACK WALNUT 11. STEEL C-CHANNEL HEADER - COLOR TO MATCH WINDOW COLOR. RE: STRUCT 12. STONE CAP W/ 10% MIN. SLOPE AT TOP TO SHED WATER RE: FINISH SCHEDULE & SPEC 13. STEEL BEAM - COLOR TO MATCH WINDOW COLOR. RE: STRUCT 14. 8X8 WOOD STRUT W/ KNIFE PLATE CONNECTIONS @ WALL AND STEEL BEAM- COLOR: PORTER STAINS 709 BLACK WALNUT 15. 8X8 WOOD COLUMN W/ STEEL CAP AND 3X3 HSS COLUMN CONNECTIONS @ TOP AND BOTTOM- COLOR: PORTER STAINS 709 BLACK WALNUT 16. TYPICAL STEEL HANDRAIL - POWDER COAT. RE: FINISH SCHEDULE & SPEC 17. 5" ROUND PFSM GUTTER AND 3" DOWNSPOUT IN DARK BRONZE. PIPE UNDERGROUND TO DAYLIGHT OUTSIDE OF AREA OF EXCAVATION FOR FOUNDATION AND PROVIDE POWER FOR HEAT TAPE. 18. 4X4 TUBE STEEL COLUMNS @ CHIMNEY CAP PAINTED TO MATCH ROOF COLOR. 19. 3" THICK STONE CHIMNEY CAP RE: FINISH SCHEDULE & SPEC 20. SNOW FENCE TYP. SEE ROOF PLAN FOR LOCATIONS 21. NORTHWEST DOOR 800 SERIES IN DARK BRONZE W/ WHITE DIFFUSED LAMINATED PANELS RE: FINISH SCHEDULE & SPEC 22. 8X12 BARGE RAFTER @ CERTAIN ROOF RAKE CONDITION 23. 4" BATH/DRYER VENT. PAINT TO MATCH ADJACENT STUCCO/SIDING Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 9/26/2014 4:39:43 PM A4.2 ELEVATIONS AC HB, SLJ LEEVER RESIDENCE 9-29-14 5087 Main Gore Drive North, Vail CO Subdivision: Bighorn 5th Addition Block: 1 Lot: 2 CHANGE TO APPROVED PLANS 1/4" = 1'-0" 1 EAST ELEVATION 1/4" = 1'-0" 2 WEST ELEVATION No. Revision Date Revision Description 1 9-29-14 CHANGE TO APPROVED PLANS WIDENED MASTER BEDROOM FIREPLACE @ UPPER LEVEL. DRB APPROVED 10/21/2014 12:00:00 AM