Z:\2011\112145\IV. Current Documents\04. Plot Sheets\A0.05.dwg, 7/30/2015 8:44:36 PM, Adobe PDF
H
Level of
Exit
Discharge
(Below)
IBC 404.6 Ex. 3
Atrium Fire Barrier
Not Required
IBC x.
Atrium Smoke Control
Not Required
L
IBC 1016.2
Travel Distance
118'-3"
IBC 1028.10.1
Table Seating
o Exit
Through
Retail
0)
O
IL
0
OPEN T
N
IBC 1016.2
Travel
Distance
182' - 0"
11 M Ii Ill
RE_,A,. 'ANT TERRAC'wag
AURANT
ccupancy
254 ft2
5 ft2/Occupant
4 Occupants
1-1
L
IBC 028 10.1
Table Seating
36' AISLE
EXIT 2
(TERRACE)
IBC 1015.1
Occupant
Load < 50
EXIT 1
IBC 1015.1
Occupant Load
< 50'-0"
AKD_
OFFICE
B Occupancy
151 ft2
100 ft2/Occupant
2 Occupants
OFFICE
B Occupancy
294 ft2
100 ft2/Occupant
3 Occupants
EXIT 2
IBC 1015.1
Occupant
Load < 50
2"
3 \ BANQUET EXIT 2
\ IBC 1015.1
Occupant Load < 50 -0
F-1 Occupanc
424 ft2
0 ft2/
ccup.
KITCHEN
1 cupanc
273 ft2
200 ft2/Occ I
2cc ¶.ntsl
99
L_
II
IBC 1007.1 Ex. 1
Accessible Means of
Egress Not Required
EXIT 2
STFRRAC.F1
IBC 1015.1
Occupant
Load < 50
IBC 1028.10.1
Table Seating
STORAGE
S-2 Occupancy
74 ft2-300 ft2/Occ.
Occupant
IBC 404.5 Ex. 1
Atrium Smoke Control
Not Required
Level of
Exit
Discharge
(Below)
J � L
IBC 3004.1
NonVented
1Hoistway r
IBC 404.6 Ex. 3
Atrium Fire Barrier
Not Required
iI
L
32"
PREFUNOTION
A-2 Occupancy
Accessory Occupancy
608 ft2
15 ft2/Occupant
40 Occupants
IBC 1007.1 Ex. 1
Accessible Means of
Egress Not Required
EXIT 1
IBC 1015.1
Occupant Load
< 50'-0"
J
•
PANIC
IBC 1016.2
travel Distance
175' - 4"
IBC 1016.2
Travel Distance
108' - 4"
PANIC
I 101
pan .. d < 50'-0'
7
TI
II
II
II
II
II
II
II
II
II
II
II
�II
II
II
II
�II
II
II
II
II
II
�II
II
II
II
II
II
II
II
II
II
II I
BANQUET TERRACE
A-2 Occupancy
❑ 2,840 ft2
15 ft2/Occupant
190 Occupants
EXIT 1
(TERRACE)
IBC 1015.1
Occupant 99�
Load < 50 IBC 1007.1 Ex. 1
Accessible Means of
I I Egress Not Required
Level of
Exit
Discharge
(Below)
L
/
/
/
J
48x48
n
17
L J
- Occupants
xx - Door Rating
Indicates required ADA
clearances
- Fire Extinguisher
1 Hour Rated Fire Barrier
CODE REVIEW SUMMARY
Town of Vail - (Ord. 12 (2012) § 1 May 1, 2012)
Adopted Codes:
• The international building code, 2012 edition, including appendix chapters B, C, E, G,
J and K (Including Amendments)
• The international fire code, 2012 edition, including appendix chapters A, B, C, D, E,
G, H and J as amended(Including Amendments)
• The international mechanical code, 2012 edition (Including Amendments)
• The international plumbing code, 2012 edition (Including Amendments)
• The international fuel gas code, 2012 edition, (including Amendments)
• The international energy conservation code, 2012 edition (Including Amendments)
• The national electrical code, 2011 edition (Including Amendments)
• The uniform code for the abatement of dangerous buildings, 1997 edition
2012 International Building Code
• 303.3 - A-2 Occupancy (Existing - Assembly "Banquet halls, Restaurants & bars")
• 503 - Type 5-B Construction (Sprinkled) - Existing/Proposed Structure
o Height - 40 Feet Allowed/ 33'-0" Proposed
o Height - 1 (2 stories allowed with 506.3 increase) / 2 Story Proposed
o Area per Story - 6,000 sq. ft. Allowed
o Building area and height modifications - additional 10,500 sq. ft. allowed (see
sections 506.2 and 506.3)
o Lower Level 14,148 + Upper Level 7,770 = Total Proposed 21,918 sq. ft.
• 504.2 - Automatic Sprinkler System Increase
o Maximum building height increased by 20'-0" and the maximum number of
stories is increased by one.
• 506.2 - Frontage Increase - Maximum 75% additional building area increase
o Entire perimeter of building is sided by public way or open space >30'-0"
o 25% of building perimeter with frontage width greater than 20'-0" on
Public Way
o Width of public way and open space greater than 30'-0"
o 6,000 allowed for A-2 (Type 5-B) multiply by 0.75 = Additional 4,500 sq. ft.
• 506.3 - Automatic Sprinkler System Increase
o Building equipped throughout with approved system in accordance with
Section 903.3.1.1
o Additional 200% additional building area increase, Additional 6,000 sq. ft.
o Additional 1 Story Permitted
• 311.3 - S-1 Occupancy (Existing - Moderate Hazard Storage - Golf Carts "Tires,
Batteries, Electrical Motors")
• 508.4 - Separation of Areas between A-2 and S-1 shall require a 1 hour rating.
• Table 601 - Fire Resistance Rating Requirements for Building Elements (Hours)
o Type 5-B requires a typical 0 hour rating
• 602.5 Type 5 Construction
o Structural elements, exterior walls, and interior walls are of any materials
permitted by this code.
• 404.2 Atrium - Use
o The floor of the atrium may not be used for other than low fire hazard use,
Except where the individual space is protected with an automatic sprinkler
system in accordance with section 903.3.1.1
• 404.5 Atrium - Smoke Control
o Smoke Control required, Except where only two stories are connected.
• Table 509 - Incidental Use: Rooms with boilers where the largest piece of equipment
is over 15 psi and 10 horsepower - 1 hour or provide automatic sprinkler system.
• Table 1004.1.2 - Maximum Floor Area Allowances Per Occupant
o Assembly without fixed seats = 15 net
o Accessory Mechanical equipment and storage = 300 gross
MEANS OF EGRESS
• TABLE 1016.2 - OCCUPANCY A, S-1 (with Sprinkler Syatem)
o Exit Access Travel Distance limited to 250 feet
• 404.9 - Travel Distance (Atrium)
o In other than the lowest level of the atrium, where the required means of
egress is theough the atrium space, the portion of exit access travel distance
within the atrium space shall not be greater than 200 feet.
TOV STAMP
AND ASSOCIATES, INC.
I N ARCHITECTURE - PLANNING - INTERIORS
LANDSCAPE ARCHITECTURE
101 El Paseo
Santa Barbara, California 93101
(805) 963-6890 FAX (805) 963-8102
CIVIL MECHANICAL
Marcin Engineering, Tom Marcin (970) 748-0274 AEC, Stanton O. Humphries (970) 748-8520
STRUCTURAL ELECTRICAL
Monroe and Newell, Hannes Spaeh (970) 949-7768 AEC, Stanton O. Humphries (970) 748-8520
48 East Bi
P.O. Box
(970) 949
SE"
7'
CO
i�i
f:.1
0
4.1
i i.r1O I jt �' ROOD C)
(LCL%✓:� j�
WI \ •�,
':-FL-) AL'
U
W
n0
Ce CI
°I ci
z
z°,
Q o
W 0g
nI
Z
<
I
W J N
Ci) 0 V tr,
- ,.1
0 Q O
to
._
ick
0 ti
(..) co
J D
U
<451, U
ISSUED FOR:
No.
DATE
COMMENT
A
09/28112
PEC WORKSESSION
B
14)3/12
FINAL PEC SUBMITTAL
C
14/31/12
PEC REVISIONS
D
04/22/13
PEC RESUBMITTAL
E
03/23/15
DRB SUBMITTAL
F
04/10/15
DRB RESUBMITTAL
G
04/34/15
DRB RESUBMITTAL
H
05/13/15
100% DD
J
06/15/15
50% CDs
K
07/13/15
PERMIT SET
L
07/27/15
ADDENDUM A
M
07/31/15
ADDENDUM B
CODE SHEET
UPPER LEVEL
PROJECT No.
20112145
ORIGIN DATE
07/13/15
DRAWN BY
PF
CHK BY
TL
TRV BY
SHEET No.
A0.05
SCALE: AS SHOWN