HomeMy WebLinkAboutDRB140551_A2-2_1423001760.pdfAD
E
F J
K
M
N
O
Q R
S
T
U X
Y AA Z
BB
P
G 14' - 10" 7' - 4 11/16" 18' - 11 3/8"
5' - 10"
27' - 2 3/4" 5' - 11 1/2" 28' - 8" 11' - 4" 24' - 11" 21' - 7" 12' - 3 1/2" 3' - 4 7/16"7' - 7 9/16"
3' - 7" 8' - 8"
GG
1854 SF
SECONDARY UNIT
LOWER LEVEL
2976 SF
PRIMARY UNIT LOWER
LEVEL
27' - 8 1/2" 25' - 9 1/2" 13' - 6 1/2" 39' - 4" 17' - 3"
4' - 3"
1' - 0"
4' - 0"
14' - 0"
1' - 9 1/2"
4' - 10 1/2" 9' - 11 1/8" 6' - 8 7/8" 15' - 11 1/2"
5' - 4 1/4"
3' - 0"
B
CH
I
11' - 0"
W V
6' - 8 7/8" 12' - 6 1/4" 3' - 4 7/16"4' - 10 1/2" 12' - 3 1/2" 1' - 2 1/2" 21' - 7" 1' - 9 1/2" 24' - 11" 14' - 0" 11' - 5" 5' - 10" 28' - 7" 8' - 8" 5' - 11 1/2" 3' - 7" 27' - 2 3/4"
14' - 10" 5' - 4 1/4" 7' - 5 9/16" 3' - 0" 18' - 11 3/8" 27' - 8 1/2" 4' - 3" 25' - 8 1/2" 1' - 0" 13' - 7 1/2" 1' - 0" 39' - 4" 4' - 0" 17' - 3" 15' - 11 1/2" 11' - 0"
A C E F G I
V
LOWER LEVEL T.O. SLAB @
86' - 0"
B.O. STRUCTURE @
96' - 0" 10' - 0" W X
L N
Q R Y Z AA BB CC DD GG S T U
LOWER LEVEL T.O. SLAB @
84' - 0"
B.O. STRUCTURE @
94' - 0"
10' - 0"
LOWER LEVEL T.O. SLAB @
84' - 0"
2' - 0"
10' - 0"
B.O. STRUCTURE @
94' - 0"
TOTAL WALL AREA= 4,520 SF
COVERED WALL AREA = 2,581 SF
2,581 SF / 4,520 SF = .57X 100= 57% OF THE LOWER LEVEL
EXTERIOR WALL IS COVERED. THEREFORE 43% OF THE LOWER
LEVEL AREA COUNTS TOWARDS GRFA.
LOWER LEVEL T.O. SLAB @
86' - 0"
B.O. STRUCTURE @
96' - 0"
B D H O J K M P
EE FF
B.O. STRUCTURE @
99' - 0"
B.O. STRUCTURE @
101' - 0" 1' - 0"
L DD
CC EE FF 12' - 6 1/4"
1' - 2 1/2"
14' - 0 1/2"
2320 SF
PRIMARY UNIT
651 SF
PRIMARY UNIT
GARAGE
1263 SF
SECONDARY UNIT
MAIN LEVEL
603 SF
SECONDARY UNIT
GARAGE
790 SF
UNIT #2 UPPER LEVEL
AREA
616 SF
UNIT #1 UPPER LEVEL
AREA
4904 SF
SITE COVERAGE
75 SF
AREA OF ROOF
BEYOND 4'
3 SF
AREA OF ROOF
BEYOND 4'9 SF
AREA OF ROOF
BEYOND 4' 5 SF
AREA OF ROOF
BEYOND 4'
7 SF
AREA OF ROOF
BEYOND 4'
2 SF
AREA OF ROOF
BEYOND 4'
LINE 4' BEYOND
BUILDING FOOT PRINT
LINE 4' BEYOND
BUILDING FOOT PRINT
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue
Date
12/15/2014 3:46:26 PM
3/32" = 1'-0"
1226 WEST HAVEN CIRCLE
GLEN LYON SUB, LOT 38, BLK 0418
VAIL, CO
A2.2
AREA
CALCS
11-24-14
BKW
HB
11-24-14
TOV FINAL DRB
3/32" = 1'-0"
1
LOWER LEVEL AREA PLAN
3/32" = 1'-0"
2
MAIN LEVEL AREA PLAN
3/32" = 1'-0"
3
UPPER LEVEL AREA PLAN
3/32" = 1'-0"
4 SITE COVERAGE1
REVISION SCHEDULE
# DESCRIPTION DATE
1 DRB PLANING
COMMENTS
12-15-14
2975 x 0.43 = 1280
2968 - 600 = 2368
1852 x 0.43 = 797
1863 - 600 = 1263
Unit 2 GRFA
UL: 790
ML: 1263
LL: 797
Net: 2850
Unit 1 GRFA
UL: 616
ML: 2368
LL: 1280
Net: 4264
X
DRB
APPROVED
2/3/2015 12:00:00 AM