Loading...
HomeMy WebLinkAboutDRB140551_A3-4B_1423001760.pdfUP +101'-9" TRENCH DRAIN DRIV +103' TRENCH DRAIN +104'-0" +103'-0" +102'-0" +103'-6" E96 E94 E90 E88 E86 1% 5% 8.6% 11.2% N102 N104 N100 N92 N90 N88 N86 N84 N82 S W ALE S W A LE N102 11.9% +103' B.O.W.89' - 6" T.O.W.93' - 6" B.O.W.89' - 6" LINE OF DECK ABOVE FIRE PIT 20' FRONT SETBACK 20 15' SIDE SET BACK ' A4.1 3 A4.1 2 A4.5 1 A4.4 1 A4.7 1 1 A5.13 1 A5.14 1 A5.15 1 A5.16 1 A5.17 1 A5.8 1 A5.9 1 A5.10 1 A5.11 1 A5.18 1 A5.19 UNIT #2 LOWER LEVEL 8086 MAIN LEVEL 8098 MUDROOM 8102' - 4 3/8" UPPER LEVEL 8111' - 10 1/2" 1 1/2" / 12" 3 1/2" / 12" 2" / 12" 2" / 12" 2" / 12" 2" / 12" 2" / 12" 2" / 12" 1B 1B 2B 2B 3B 3B 7B 7B 6B 6B 5B 5B 10B 10B 1A 1A 4B 4B 8B 8B 9B 9B AA BB CC DD EE FF GG HH II JJ A B C D E F G T.O. ROOF EAVE @ 120' - 8" T.O. ROOF RIDGE @ 122' - 8" T.O. ROOF EAVE @ 124' - 9" T.O. ROOF EAVE @ 119' - 7" *1B *2B *3B *6B *5B *4B T.O. ROOF EAVE @ 119' - 7" 8 3/4" 41' - 4 1/2" 3' - 7" 8' - 10 1/2" 2' - 6 1/2" 7' - 7 5/8" 14' - 5 7/8" 4' - 3" 61' - 1 1/2" 8 3/4" 5' - 1 3/4" 3' - 2 1/2" 13' - 3 1/2" 5' - 9 1/2" 5' - 11 1/2" 2' - 8" 6 1/2" 11' - 2 1/2" 13' - 3 3/4" 45' - 6" 1' - 0" 4' - 0" 11' - 11 1/2" 4' - 0" 10' - 3 1/2" 6' - 4 1/2" 4' - 10 1/2" 1' - 2 1/2" 1' - 9 1/2"41' - 4 1/2" 3' - 7" 8' - 10 1/2" 2' - 6 1/2" 7' - 7 5/8" 14' - 5 7/8" 4' - 3" T.O. EXISTING GRADE @ 93' - 0" T.O. EXISTING GRADE @ 95' - 1" T.O. EXISTING GRADE @ 87' - 0" T.O. EXISTING GRADE @ 87' - 1" 1 A5.1A 2" / 12" 2" / 12" 1 A5.12 - - GENERAL NOTES: LOT SIZE IS .4611 ACRES EQUAL TO 20,086 SF 1.) SEE L-1 LANDSCAPE PLAN FOR GENERAL LANDSCAPE, GRADING, AND EROSION CONTROL NOTES 2.) EXTERIOR LIGHTING- 1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 20 LIGHTS ARE ALLOWED. 20 EXTERIOR LIGHTS 18" ABOVE GRADE ARE PROPOSED. SEE ELEVATIONS AND PLANS FOR TYPE, LOCATION AND NUMBER OF FIXTURES. 3.) ROOF HEIGHT CALCULATIONS (ALSO SHOWN ON ROOF PLAN): MEASURED TO TOP OF SHEATHING ON TOP OF STRUCTURAL ROOF TO FINISHED OR EXISTING GRADE DIRECTLY BELOW (WHICHEVER IS MORE RESTRICTIVE). ROOF CALCULATIONS SHOWN ARE FOR ONLY THE UPPER ROOF CLOSES TO THE BUILDING HEIGHT LIMIT. *1B- ROOF EAVE HEIGHT @ SHEATHING = 8120' - 8" EXISTING GRADE BELOW EAVE = 8089' - 6" ROOF HEIGHT = 31' - 2" *2B- ROOF EAVE HEIGHT @ SHEATHING = 8119' - 7" EXISTING GRADE BELOW EAVE = 8087' - 0" ROOF HEIGHT = 32'- 7" *3B- ROOF EAVE HEIGHT @ SHEATHING = 8120'- 0" EXISTING GRADE BELOW EAVE = 8088'- 2" ROOF HEIGHT = 31' - 10" *4B- ROOF RIDGE HEIGHT @ SHEATHING = 8122'- 11" EXISTING GRADE BELOW EAVE = 8093'- 0" ROOF HEIGHT = 29' - 11" *5B- ROOF EAVE HEIGHT @ SHEATHING = 8124'- 9" EXISTING GRADE BELOW EAVE = 8095'- 2" ROOF HEIGHT = 29' - 7" *6B- ROOF EAVE HEIGHT @ SHEATHING = 8122'- 3" EXISTING GRADE BELOW EAVE = 8090'- 6" ROOF HEIGHT = 31' - 2" US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 1/29/2015 5:08:02 PM 1/4" = 1'-0" 1226 WEST HAVEN CIRCLE GLEN LYON SUB, LOT 38, BLK 0418 VAIL, CO A3.4B UNIT 2 - ROOF PLAN 1-07-15 BKW HB 1-07-15 TOV FINAL DRB SET 1/4" = 1'-0" 1 UNIT 2 - ROOF PLAN REVISION SCHEDULE # DESCRIPTION DATE DRB APPROVED 2/3/2015 12:00:00 AM