HomeMy WebLinkAboutDRB140551_A6-2_1423001760.pdfT.O. PLYWOOD RE: PLANS INTERIOR INTERIOR EXTERIOR FILL JOIST CAVITY W/ INSULATION RE: SPEC. GRID LINE RE: STRUCT. RE: STRUCT. PROVIDE 2" RIGID INSULATION OVER 2" VOID ATTACH RIGID INSULATION TO UNDERSIDE OF CONC. SLAB W/ WIRE TIRES RE: SPEC W.P. MEMBRANE CONT. OUT HORIZONTALLY 3'-0" CONTINUE MEMBRANE UP WALL 1'-6" AND UNDER DOOR SILL NOTE: SEE 1/A6.1 FOR TYPICAL FOUNDATION NOTES 1 1/2" 2# CLOSED CELL SPARY FOAM INSULATION BETWEEN 2X FURRING 2X P.T. FURRING HELD 1/2" OFF OF CONC. FOUNDATION WALL 2" T.O. FINISHED FLOOR 1" TYP. WOOD FLOOR ASSEMBLY CUSTOM CUT STONE DOOR SILL SET IN BED OF SEALANT/ ADHESIVE 1/16" RADIUS EASED EDGE 1/4" SEALANT JOINT BTW COPPER FLASHING AND STONE FLOORING 1 1/2" GYPCRETE SLAB W/ IN-FLOOR RADIANT HEAT AUTOMATIC DOOR SWEEP ACTIVATED BY PIN @ JAMB P.T. WOOD LEDGER RE: STRUCT. RE: STRUCT. OVERFRAMING 4 1/2" 5 1/2" 4" 3" 5" 9 3/4" STRUCTURAL CONC. SLAB POURED OVER T.O. CONC. WALL. RE: STRUCT. 1 1/2" 8" INTERIOR GRID LINE RE: STRUCT. RE: STRUCT. RE: STRUCT. SEE DETAIL 1/A6.1 FOR TYP. FOUNDATION NOTES 1 1/2" 2# CLOSED CELL SPARY FOAM INSULATION BETWEEN 2X FURRING INTERIOR 2X P.T. FURRING HELD 1/2" OFF OF CONC. FOUNDATION WALL 1 HR COMMON FOUNDATION WALL GRID LINE PROPOSED FUTURE PROPERTY LINE PROVIDE 5/8" TYPE 'X' RATED DRYWALL WITHIN 4' OF PROPERTY LINE SLOPE RE: PLANS INTERIOR GRID LINE T.O. SLAB RE: FLOOR PLANS 5 1/2" 2 1/2" BASE BOARD TYPICAL RE: INT. SEALANTJOINT B/W EDGE OF SLAB & WALL TO PREVENT RADON GAS INFILTRATION RE: RADON GAS MITIGATION NOTES PROVIDE 2" RIGID INSULATION HELD DOWN 1/2" @ EDGE OF SLAB W/ BEVEL CUT AS SHOWN P.T BOTTOM PLATE EXTERIOR GRADE OR PATIO SLOPE GRADE @ 10% MIN. SLOPE PATIO @ 1.25% MIN. RE:FLOORPLANS EXTERIOR RE: STRUCT RE: STRUCT SEE DETAIL 1/A6.1 FOR TYP. FOUNDATION NOTES MIRADRAIN CONTINUOUS @ T.O. CONC. LEDGE AND STL ANGLE TO ALLOW STONE VENEER DRAINAGE MEDIUM TO DRAIN MIN. 6" TRANCH DRAIN SEE SITEPLAN INTERIOR EXTERIOR GRID LINE RE: STRUCT. RE: STRUCT. SEE DETAIL 1/A6.1 FOR TYP. FOUNDATION NOTES 1 1/2" 2# CLOSED CELL SPARY FOAM INSULATION BETWEEN 2X FURRING 2X P.T. FURRING HELD 1/2" OFF OF CONC. FOUNDATION WALL SLOPE RE: PLANS 8" 2" GARAGE 0' - 1" RIGID INSULATION UNDER SLAB RE: SPEC 2X TRIM BOARD AT GARAGE DOOR JAMB BEYOND 4" CONC. SLAB WP MEMBRANE OVER 3/4 PLYWOOD OVER 2X SLEEPERS SLOPED TO CENTER DRAINS RE: STRUCT AND FLOOR PLANS GARAGE DOOR PROVIDE GASKET AT B.O. GARAGE DOOR 5 1/2" RADIANT HEAT TUBES IN LAYER OF SAND. HEATED SAND SET TUMBLED CONC. PAVERS OVER RIGID INSULATION RE:SPEC. INSTALL PER MANUF. RECOMMENDATIONS SLOPE RE: PLANS W.P. EPOXY LIQUID GRANITE FLOORING OVER CONC. SLAB AND TURNS UP WALL MIN 6" RE: SPEC PRESSURE TREATED PLATE T.O. PLYWOOD RE: FLOOR PLANS INTERIOR EXTERIOR GRID LINE FILL JOIST CAVITY W/ INSULATION RE: SPEC RE: STRUCT. 2" RE: STRUCT. RE: STRUCT. FINISHED FLOOR RE: PLANS AND SPEC OVER GYPCRETE W/ IN-FLOOR RADIANT HEAT RE: PLANS AND SPEC. TOTAL ASSEMBLY FOR FINISH & GYPCRETE IS 2 1/4" P.T. WOOD LEDGER RE: STRUCT. SEE DETAIL 1/A6.1 FOR TYP. FOUNDATION NOTES 1 1/2" 2# CLOSED CELL SPARY FOAM INSULATION BETWEEN 2X FURRING 2X P.T. FURRING HELD 1/2" OFF OF CONC. FOUNDATION WALL SLOPE RE: PLANS W.P. MEMBRANE CONT. FROM B.O. FOOTING DOOR SILL SET IN BED OF SEALANT OVER FLASHING RE: SPEC STEP 4" HEATED SAND SET TUMBLED CONC. PAVERS OVER RIGID INSULATION RE:SPEC. INSTALL PER MANUF. RECOMMENDATIONS PT BLOCKING ATTACHED TO CONC. WALL TO SUPPORT DOOR THRESHOLD REINFORCED CONC. SLAB PER STRUCT. 1/2" EXPANSION JOINT EXPANSION BOLT BASE PLATE TO CONC. PIER RE: STRUCT. HSS COLUMN WELDED TO TOP AND BOTTOM STEEL PLATES. COVER PORTION BELOW T.O. STONE W/ DAMP PROOFING RE: STRUCT. 8" X 8" STEEL BASE PLATE RE: STRUCT. KNIFE PLATE W/ THRU-BOLTS RE: STRUCT. 1" NON EXPANSIVE GROUT BED 9 1/2" 3" STONE FLOORING ASSEMBLY - APPROX. 11/2" TO 2" OF STONE OVER 1" TO 1 1/2" GROUT W/ RADIANT SNOWMELT HEATING TUBES IN THE GROUT OVER CONC. SLAB. SECURE TUBING TO CONC SLAB W/ CLIPS RAMSET TO CONCRETE. *NOTE - NO INFLOOR RADIANT HEAT TUBING @ LOWER LEVEL PATIOS RE: STRUCT RE: STRUCT. 8" X 8" STEEL BASE PLATE. PROTECT ALL SURFACES W/ LAYER OF DAMP PROOFING RE: STRUCT. CONC. PIER RE: STRUCT. 4" GRAVEL PER SOILS REPORT 2" US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 11/24/2014 12:08:10 PM 1 1/2" = 1'-0" 1226 WEST HAVEN CIRCLE GLEN LYON SUB, LOT 38, BLK 0418 VAIL, CO A6.2 FOUNDATION DETAILS 11-24-14 BKW HB 11-24-14 TOV FINAL DRB REVISION SCHEDULE # DESCRIPTION DATE 1 1/2" = 1'-0" 1 FOUNDATION DETAIL @ UNIT 1 ENTRY 1 1/2" = 1'-0" 2 FOUNDATION DETAIL @ PROPERTY LINE 1 1/2" = 1'-0" 3 FOUNDATION DETAIL @ LOWER LEVEL STONE VENEER @ GRADE 1 1/2" = 1'-0" 10 FOUNDATION DETAIL @ GARAGE DOOR THRESHOLD 1 1/2" = 1'-0" 11 FOUNDATION DETAIL @ MUDROOM THRESHOLD 1 1/2" = 1'-0" 12 WOOD COLUMN BASE DETAIL @ LOWER LEVEL PATIO DRB APPROVED 2/3/2015 12:00:00 AM