Loading...
HomeMy WebLinkAboutDRB140551_Zone Check Sheet_1423001400.docPLANNING CHECK SHEET Property Information  Property Address 1226 Westhaven Cr.  Parcel # 2103-121-0700-7  Legal Description GLEN LYON SUB, LOT 38  Development Site Area Ac 0.4611 Sq Ft 20,085 Buildable   Zoning / SDD # Two-Family Primary-Secondary  Land Use Designation Low Density Residential  Known Non-Conformities   Previous Approvals   Hazard Zones Sections 12-12, 12-21, 14-6 & 14-7 Snow Avalanche NA   Debris Flow NA   Rockfall NA   Excessive Slopes (Site Disturbance 12-21-14) NA   Floodplain NA  Wetlands Y/N n  Creeks, Streams Section 12-14-17 NA Setback NA Proposed NA  Sidewalks/ Trails NA  Contact Information  Planner/ Date Joe Batcheller  Owner Contact Info Tom Jaffe, PO BOX 745, Vail, CO  Primary Contact/ Owner Representative Info BERGLUND ARCHITECTS, 970-926-4301  Project Information  Project Description New Construction: Two-Family P/S Residential  Land Use Application(s) # DRB140551  Proposed Uses (As defined by Zoning) Primary-Secondary Permitted, Conditional, Prohibited? Y  Date Routed/ DRT Meeting 12/17/2014  Commercial Floor Area Existing NA Proposed NA  Gross Residential Floor Area (Chapter 15)  Total Allowed 7,161 -Existing 0 -Proposed 7,118     Primary 7,161 -Existing 0 -Proposed 4,264     Secondary 2,864 -Existing 0 -Proposed 2,854    Total Remaining  43 Primary Total Remaining  43 Secondary Total Remaining  10  250 or Interior Conversion?   Zoning District Standards  Setbacks (perimeter) Projections 14-10-4 Front 20’ Proposed or Y/N Y   Side 15’ & 15’ Proposed or Y/N Y   Rear 15’ Proposed or Y/N Y  Minimum Lot Area/ Width Required 14,000 Proposed or Y/N Y  Site Coverage % Allowed 25% (5,021) % Proposed 25% (5,014)  Building Height Allowed 33’/30’ Proposed 32’8”  Landscaping Sections 14-10-8 & 14-10-9 % Required 60% (12,051) % Proposed 64.2% (12,886)   Plant size  Proposed 10’-14’   Fences  Proposed N   Retaining Walls Sec. 14-6-7 Height Allowed 6’ Proposed 4’   Setback 3’ Proposed 4’  Driveway Sections 14-3-1 & 14-3-2 Max Curb-cuts 2 Proposed 2   Max-Min Slope 12% Proposed 11.2% & 10.5%   Max-Min Width 12’-48’ Proposed 34’   Heated Y/N Y Drive Material Pavers   Snow Storage % 10% Proposed >10%  Parking Sections 12-10 & 14-5 Spaces Required 7 Proposed 8   Loading NA Proposed NA  Lighting Section 14-10-7 Allowed 20 Proposed 20  Waste Management Section 5-9 Wildlife Proof/ Resistant NA Screened NA  Screening Sections 14-10-9 & 14-10-10 Required NA Proposed NA  Roof Material Sections 12-11-3C & 14-10-5 Complies Y/N Y: standing seam metal  Building Separation Section 14-10-6 Complies Y/N Y  Adopted View Corridors Complies Y/N NA  Utilities (Location, easements) Section 14-10-10   Grading (Less than 2:1) Section 14-6 Y  Development Impact Fees / Mitigation Employee Housing NA   Traffic Impact NA   Art In Public Places NA  Notes