HomeMy WebLinkAboutDRB140563_A6-5_1424821140.pdfRE: ROOF PLAN / SECTIONS GRID LINE WOOD SIDING RE: SPEC (REFER TO ELEVATIONS FOR LOCATIONS) SLOPE PER ROOF PLAN 3D DRAINAGE MEDIUM CONT. BEHIND SIDING TO AIR VENT MATERIAL AT TOP OF WOOD SIDING CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. SEE 1/A6.5 FOR TYPICAL ROOF EAVE NOTES 21.8° 7 1/2" KNIFE PLATE RE: STRUCT. PAINT ALL EXPOSED THROUGH BOLTS RE:STRUCT. 3" HSS COLUMN WELDED TO B.O. BEAM & 7 1/2" X 7 1/2" X 1/2" STEEL BASE PLATE WELDED TO KNIFE PLATE. NO COLUN OR PLATE AT SIM. CONDITION. RE: STRUCT. & SPEC 8X8 ANGLED WOOD COLUMN. NO STRUT AT SIM. CONDITION RE: STRUCT. STEEL BEAM. NO BEAM AT SIM. CONDITION RE: STRUCT. BIRDSMOUTH CUT RAFTER KNIFE PLATE RE: STRUCT. GRID LINE 6X10 RAFTER TAIL ATTACHED TO WOOD RAFTERS @ 48" O.C. RE: STRUCTURAL DRAWINGS DRIP FLASHING OVER FASCIA RE: SPEC STANDING SEAM METAL ROOFING RE: SPEC 5/8" PLYWOOD SHEATHING 6X10 WOOD RAFTER LAG BOLTED TO EXTERIOR WALL - LAG BOLTS TO BE COUNTER SUNK AND PLUGGED 2X4 BLOCKING PLYWOOD BLOCKING EXTEND ROOF SHEATHING TO EDGE OF ROOF TYP. EXTERIOR WALL ASSEMBLY RE: ELEVATIONS / SECTIONS CANTILEVERED 2X6 T&G DECKING WORKING POINT RE: ROOF PLAN CONTINUOUS 2X8 FILL CAVITY W/ SPRAY FOAM AND BLOWN-IN INSULATION RE: SPEC TYPICAL ROOF RAKE NOTES: RE: ELEVATIONS FOR SIDING TYPE. NOTE CONDITION MAY HAVE STONE, METAL OR VERTICAL SIDING RAFTERS PER STRUCTURAL DRAWINGS W/ CAVITY FILLED W/ SPRAY FOAM AND BLOWN-IN INSULATION RE: STRUCT./SPEC. CUSTOM 5" ROUND GUTTER WITH ROUND DOWN SPOUTS RE: SPEC RE: ROOF PLANS FOR LOCATIONS RE: ROOF PLAN / SECTIONS GRID LINE DRIP EDGE FLASHING RE: SPEC STANDING STEAM ROOF RE: SPEC RE: ROOF PLAN FOR LOCATIONS ICE AND WATER SHIELD OVER METAL FLASHING PROVIDE 50% OVERLAP (DOUBLE LAYER) FOR FIRST 4' UP EAVE 2X6 DOUG-FIR DECKING 2X6 CEDAR FASCIA RE: ROOF PLAN FOR LOCATIONS 6x10 ROUGH SAWN DOUG-FIR RAFTER TAILS @ 48" O.C. RAFTERS SISTERED TO TJI RAFTERS TYP. EXTEND ROOF SHEATHING TO EDGE OF EAVE PLATE HEIGHTS AT SECTIONS AND ELEVATIONS ARE PER A BEVEL PLATE (RAFTER NOT SEAT CUT) RE: ROOF PLAN 3D DRAINAGE MEDIUM CONT. BEHIND SIDING TO AIR VENT MATERIAL AT TOP OF WOOD SIDING SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC TYPICAL ROOF EAVE NOTES: GRID LINE INSULATION RE: SPEC & COVER SHEET SIDING RE: SPEC (REFER TO ELEVATIONS FOR LOCATIONS) PLATE HEIGHTS AT SECTIONS AND ELEVATIONS ARE PER A BEVEL PLATE (RAFTER NOT SEAT CUT) SLOPE PER ROOF PLAN 3D DRAINAGE MEDIUM CONT. BEHIND SIDING TO AIR VENT MATERIAL AT TOP OF WOOD SIDING CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. SEE DETAIL 1/A6.1 FOR TYPICAL ROOF EAVE NOTES GRID LINE STANDING STEAM ROOF RE: SPEC 2X6 DOUG-FIR DECKING 6x10 ROUGH SAWN DOUG-FIR RAFTERS RE: RCP LEDGER RE: STRUCT WOOD SIDING RE: SPEC ROOF SHEATHING SLOPE PER ROOF PLAN 3D DRAINAGE MEDIUM CONT. BEHIND SIDING TO AIR VENT MATERIAL AT TOP OF WOOD SIDING SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. T.O. ROOF RE: SECTIONS SLOPE PER ROOF PLAN PRE-FABRICATED METAL RIDGE CAP HIGH TEMPERATURE ICE AND WATER SHIELD CONT. OVER ENTIRE ROOF PROVIDE BLOCKING & 1X CEDAR TRIM TO CONCEAL HANGERS & ATTACHMENTS @ EXPOSED LOCATIONS GRID LINE SEE 3/A6.5 FOR TYPICAL ROOF RAKE NOTES 6X10 WOOD RAFTER LAG BOLTED TO EXTERIOR WALL - LAG BOLTS TO BE COUNTER SUNK TYPICAL STONE VENEER ASSEMBLY RE: 1/A6.1 (3) 2X8 BLOCKING BUILD UP RE: ROOF PLAN WORKING POINT RE: ROOF PLAN VARIES PER OVERHANG CONT. BUG SCREEN STAPLED TO RAFTER WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL GRID LINE 4 7/8" 5/8" TYPE 'X' GWB WITHIN 4' OF PROPERTY LINE PROPOSED FUTURE PROPERTY LINE SEE 3/A6.5 FOR TYPICAL ROOF RAKE NOTES *5 1/2" @ SIM GRID LINE 5/8" PLYWOOD SHEATHING I-JOIST RAFTER @ 24" O.C. W/ INSULATION RE: STRUCT./SPEC. PROVIDE HIGH TEMP ICE & WATER SHIELD CONT. @ ROOFS. RE: SPEC ROOFING RE: ROOF PLANS CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. 1/2" 1/2" WOOD SIDING RE: ELEVATIONS FOR TYPE / NOTES AND FINISH SCHEDULE 3D DRAINAGE MEDIUM CONT. BEHIND TO AIR VENT MATERIAL AT TOP OF WOOD SIDING. HOLD DOWN 1/2" FROM B.O. SIDING GRID LINE GRID LINE PFSM DRIP FLASHING TO MATCH ROOFING OVER 2X10 FASCIA STANDING SEAM METAL ROOFING RE: SPEC FILL CAVITY W/ SPRAY FOAM AND BLOWN-IN INSULATION RE: SPEC BLOCKING RE: STRUCT. WOOD SIDING RE: SPEC (REFER TO ELEVATIONS FOR LOCATIONS) PROVIDE 5/8" TYPE 'X' RATED DRYWALL WITHIN 4' OF PROPERTY LINE EXTEND ROOF SHEATHING TO WALLBOARD STANDING SEAM METAL ROOFING RE: SPEC PROPOSED FUTURE PROPERTY LINE FLASHING GRID LINE STANDING SEAM METAL ROOF RE: SPEC 1X6 T&G DECKING ICE AND WATER SHIELD CONT. UP WALL 36" MIN. RE: SPEC RUN METAL FLASHING UP WALL MIN 6" AND OUT OVER ROOF MIN 6" LAP SELF ADHERING BITUTHANE FLASHING OVER METAL WALL FLASHING LAP AIR & WATER INFILTRATION BARRIER OVER BITUTHANE FLASHING PLYWOOD SHEATHING RE: STRUCT OVER SLEEPERS TO CREATE WIRE CHASE FOR EXTERIOR LIGHT FIXTURES AND ALIGN W/ 4X DECKING RE: RCP EXTERIOR EXTERIOR INTERIOR INTERIOR TYPICAL COPPER SIDING ASSEMBLY RE: 3/A6.4 TYPICAL COPPER SIDING ASSEMBLY RE: 3/A6.4 GRID LINE Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION As indicated 12/12/2014 3:19:19 PM A6.5 ROOF DETAILS AG HB GORE CREEK RESIDENCES 12/15/14 223 BEAVER DAM RD, VAIL, CO 81657 VAIL VILLAGE FILING 1, BLOCK 7, LOT 39 FINAL DRB SET No. Revision Date Revision Description 1 1/2" = 1'-0" 2 ROOF DETAIL @ UPPER EAVE 1 1/2" = 1'-0" 3 ROOF DETAIL @ TYPICAL ROOF RAKE 1 1/2" = 1'-0" 1 ROOF DETAIL @ TYPICAL EAVE 1 1/2" = 1'-0" 4 ROOF DETAIL - EAVE W/ NO OVERHANG 1 1/2" = 1'-0" 5 ROOF DETAIL @ UNIT B MUDROOM ROOF RIDGE 1 1/2" = 1'-0" 6 ROOF DETAIL @ TYPICAL ROOF RAKE W/ STONE VENEER 1 1/2" = 1'-0" 7 ROOF DETAIL @ ROOF RAKE @ PROPOSED FUTURE PROPERTY LINE 6" = 1'-0" 8 BUG SCREEN DETAIL @ ROOF EAVE 1 1/2" = 1'-0" 9 ROOF DETAIL @ PROPERTY LINE 1 1/2" = 1'-0" 10 FRONT ENTRY ROOF DETAIL @ UNIT A DRB APPROVED 2/18/2015 12:00:00 AM