Loading...
HomeMy WebLinkAboutDRB140563_A6-7_1424821140.pdf6" 4 3/8" 3 1/2" STEEL I-BEAM RE: STRUCT. KNIFE PLATE, THROUGH BOLT WITH COUNTER SINK BEAM TO GLULAM RE:STRUCT. GLULAM JOIST RE:STRUCT. SHIM RIPPED AT 1/8" PER 1'-0" 3/4" PLYWOOD SLOPED AT 1/8" PER 1'-0" W.P. MEMBRANE RE: SPEC. RUNS UP HSS COLUMN TO BASE PLATE ABOVE W.P. MEMBRANE TURNS UP 4X4 STEEL COLUMN SUPPORT 3 1/2". INSTALL SEALANT BETWEEN STONE AND COLUMN. DRAINAGE BOARD SLOPES AT 1/8" PER 1'-0" CUT AROUND HSS COLUMN 4" STONE ASSEMBLY- APPROX 2" OF STONE OVER 1/2" OF GROUT OVER 1 1/2" CONC. SLAB WITH RADIANT TUBING 4 1/2" W X 3 1/2" H X 3/4" T STEEL PLATE PAINTED TO MATCH WINDOW COLOR LAG BOLTED THROUGH TO END OF GLULAM PAINTED TO MATCH WINDOW COLOR 4 1/2" W X 4'-0" H X 3/8" T STANCHIONS EACH STANCHION WELDED TO STEEL PLATE BELOW PAINTED TO MATCH WINDOW COLOR 3/8" X 3/8" STEEL RODS WELDED TO STANCHIONS @ 3 3/4" O.C. PAINTED TO MATCH WINDOW COLOR 3 1/2" H X 1 1/2" W X 3/8" T STEEL WELDED TO TOP STANCHIONS WITH BOTTOM NOTCHED OUT WITH A 1/2" X 1 3/4" SLOT TO ACCEPT STANCHION CONT. PAINTED TO MATCH WINDOW COLOR 1 1/2" DIA. STEEL PIPE TOP RAIL WELDED TO PLATE BELOW W.P. MEMBRANE ADHERES TO COPPER FLASHING WHICH EXTENDS OVER EDGE WITH A DRIP EDGE AS SHOWN 4 1/2" 3 3/4" RE: PLANS 4' - 0" 3' - 10 1/4" 3 1/2" 3 1/2" 3/8" 1 3/4" 1 3/4" 4" 9 1/2" L X 9 1/2" W X 1/2" T STEEL TOP PLATE WELDS TO STEEL COLUMN RE: STRUCT. CONT. 6" W X 1/4" THICK STEEL PLATE PAINTED TO MATCH WINDOW COLOR WELDED TO STANCHIONS PROVIDE PFSM GUTTER BETWEEN RAILING AND EDGE OF DECK SEE PLANS FOR DOWN SPOUT LOCATIONS 3' - 1 3/4" 3 3/4" T.O. PLYWOOD RE: SECTIONS / PLANS INTERIOR INTERIOR FINISHED FLOOR RE: PLANS & SPEC 3/4" T&G PLYWOOD RE: STRUCT. 14" WOOD I-JOISTS BEYOND @ 16" O.C. RE: STRUCT. INSULATION RE: SPEC RIM JOIST RE: STRUCT. W.P. MEMBRANE CONT. MIN. 1'-6" UP WALLS AND CONT. UNDER DOOR SILL COPPER FLASHING CONT. UNDER DOOR SILL W/ 1" LEG CONT. OUT OVER STONE DOOR RE: SCHED. THROUGH BOLT GLULAM TO 1 3/4" X 18" JOIST RE: STRUCT. DROPPED CEILING RE: RCP & SECTIONS TYPICAL VERTICAL WOOD SIDING WALL ASSEMBLY 1" GRID LINE SEE 1/A6.7 FOR TYP. RAILING ASSEMBLY BLOCKING BTW GLULAM JOISTS ALIGN T.O. DECKING WITH T.O. PLYWOOD 4 1/2" 3 1/2" 3 1/2" 1 1/2" 3/8" 4' - 0" 6" 4" 3' - 1 3/4" 2 3/16" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 4 1/16" 3 7/8" 4 1/2" W X 3 1/2" H X 3/4" T STEEL PLATE PAINTED TO MATCH WINDOW COLOR LAG BOLTED THROUGH TO END OF GLULAM PAINTED TO MATCH WINDOW COLOR 4 1/2" W X 4'-0" H X 3/8" T STANCHIONS EACH STANCHION WELDED TO STEEL PLATE BELOW PAINTED TO MATCH WINDOW COLOR 3/8" X 3/8" STEEL RODS WELDED TO STANCHIONS @ 3 3/4" O.C. PAINTED TO MATCH WINDOW COLOR 3 1/2" H X 1 1/2" W X 3/8" T STEEL WELDED TO TOP STANCHIONS WITH BOTTOM NOTCHED OUT WITH A 1/2" X 1 3/4" SLOT TO ACCEPT STANCHION CONT. PAINTED TO MATCH WINDOW COLOR 1 1/2" DIA. STEEL PIPE TOP RAIL WELDED TO PLATE BELOW CONT. 6" W X 1/4" THICK STEEL PLATE PAINTED TO MATCH WINDOW COLOR WELDED TO STANCHIONS STEEL I-BEAM RE: STRUCT. 4" 8 1/2" L X 8 1/2" W X 1/2" T STEEL TOP PLATE WELDS TO STEEL COLUMN RE: STRUCT. SEE 1/A6.7 FOR TYP DECK ASSEMBLY SLOPE @ 1/8" : 1'-0" CUSTOM METAL GUTTER PER DIMS SHOWN SEE 1/A6.7 FOR TYP. RAILING ASSEMBLY (2) 2X8 CEDAR TRIM BOARDS W/ SHIP LAP JOINT LVL RIM JOIST RE: STRUCT. 11 7/8" 3 3/4" 2X PLATE BTW BEAM AND LVL JOISTS BLOCKING RE: STRUCT. 1X DECKING BUTTS UP TO PLATE RE: PLANS 5" Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1 1/2" = 1'-0" 12/12/2014 3:19:32 PM A6.7 DECK DETAILS AG HB GORE CREEK RESIDENCES 12/15/14 223 BEAVER DAM RD, VAIL, CO 81657 VAIL VILLAGE FILING 1, BLOCK 7, LOT 39 FINAL DRB SET No. Revision Date Revision Description 1 1/2" = 1'-0" 1 W.P. STONE DECK AND RAILING DETAIL @ UPPER LEVELS 1 1/2" = 1'-0" 3 UNIT A DINING ROOM DECK DETAIL 1 1/2" = 1'-0" 2 W.P. STONE DECK AND RAILING ELEVATION @ UPPER LEVELS 1 1/2" = 1'-0" 4 W.P. STONE DECK AND RAILING DETAIL @ MAIN LEVEL CONCEALED FRAMING DRB APPROVED 2/18/2015 12:00:00 AM