Loading...
HomeMy WebLinkAboutDRB140563_A7-2_1424821140.pdfPRIMARY UNIT MAIN LEVEL FINISHED FLOOR 8159' - 6" HEAT & GLO RUTHERFORD 42" FIREPLACE W/ GRAND OAK GAS LOG SET & HERRINGBONE BRICK VENEER 4" STONE VENEER 4" CUT STONE HEARTH SET OVER STONE VENEER APRON OVER CONC. SLAB. AND STEEL CONSTRUCTION RE: STRUCT. 6 1/4" X 12" DEEP COLORADO BUFF CUT STONE MANTEL LINE OF OUTDOOR FIREPLACE FLUE BEYOND 8" 4" FIREPLACE OPENING 3' - 2" 6 1/4" 3" 5' - 6 1/8" 3" 4" FIREPLACE OPENING 3' - 6" 4" A7.2 4 STEEL SUPPORT ANGLE LAG BOLTED INTO WOOD STRUCTURE AT EITHER SIDE OF FIREPLACE 3" STONE CHIMNEY CAP PAINTED TO MATCH WINDOW COLOR 4X4 TUBE STEEL POST CANTED AT 1:12 WELDED TO 1/2" X 6" X 4" STEEL PLATE AT TOP AND BOTTOM SET IN A BED OF SEALANT OVER FLASHING, FASTENED WITH LAG BOLTS INTO FRAMING BELOW AND EXPANSION BOLTS INTO STONE ABOVE 4" STONE CHIMNEY CAP OVER W.P. MEMBRANE OVER SLOPED 5/8" PLYWOOD AS REQ'D STEEL ANGLE RE: STRUCT LAP W.P. MEMBRANE OVER FLASHING 1 1/2" MIN. 10 3/4" 6' - 4" COUNTER FLASHING SET IN SEALANT TYP. STORM COLLAR FLASHING SET IN SEALANT OVER COUNTER FLASHING TYP. PROVIDE ELECTRONIC FLUE DAMPER AT LIVING ROOM FIREPLACE CHIMNEY 3" MIN. 2" PROVIDE SOLID BLOCKING UNDER STEEL COLUMNS FILL CAVITY WITH INSULATION TYPE X 5/8" DRYWALL CONT. TO B.O. SHEATHING 2X JOISTS W/ TOPS CUT TO SLOPE PLY WOOD ABOVE @ 1/8" PER 1'-0" MAINTAIN 2" CLEARANCE TO COMBUSTIBLES 1' - 2 1/2" 2" MIN. 1' - 0" TERMINATION CAP: MAINTAIN CLEARANCES PRESCRIBED BY CODE ABOVE ADJACENT CHIMNEY FLUES W.P. MEMBRANE CONT. UP WALL 2" MIN. 2" 4" STONE VENEER 3' - 11" 5 A7.2 4" CUT STONE HEARTH SET OVER STONE VENEER APRON CANTED 6" STONE VENEER @ BOTH SIDES FIREPLACE RE: ELEVATION SLOPED 2X6 FRAMED WALL @ SIDES OF FIREPLACE ONLY RE: SECTION HEAT & GLO CHIMNEY PER MANUF. MAINTAIN CLEARANCES FROM COMBUSTIBLES PER MANUF. REQUIREMENTS NOTE: CONTRACTOR TO HAVE COPY OF FIREPLACE & FLUE MANUFACTURER INSTALLATION INSTRUCTIONS/REQUIREMENTS ON SITE FOR BUILDING INSPECTOR'S REFERENCE HEAT & GLO RUTHERFORD 42" FIREPLACE W/ GRAND OAK GAS LOG SET & HERRINGBONE BRICK VENEER 3/8" PATINA STEEL PLATE MANTEL ABOVE A7.2 1 Sim A7.2 2 Sim 4" COLORADO BUFF CUT STONE SLAB HEARTH. PROVIDE STEEL ANGLE LAG-BOLTED INTO FRAMING TO SUPPORT STONE SLAB TYPE L - LED TAPE LIGHT UNDER STONE HEARTH L POCKET DOOR RE: WINDOW SCHEDULE 2' - 6 3/16" 1' - 6" 2' - 6 15/16" MIN. 1 1/2" MIN. 1 1/2" 1' - 3 1/8" HEARTH FRAMING 5' - 6 1/8" 3" 2 5/16" 1' - 0" TO BASE OF SLOPED STONE VENEER 8' - 9 3/4" PRIMARY UNIT MAIN LEVEL FINISHED FLOOR 8159' - 6" B C D 7 A7.1 HEAT & GLO RUTHERFORD 42" FIREPLACE W/ GRAND OAK GAS LOG SET & HERRINGBONE BRICK VENEER 4" STONE VENEER 4" CUT STONE HEARTH SET OVER STONE VENEER APRON OVER CONC. SLAB. AND STEEL CONSTRUCTION RE: STRUCT. 3/8" PATINA STEEL PLATE MANTEL TO BASE OF SLOPED STONE VENEER 7' - 4 1/2" 1' - 0" 4" FIREPLACE OPENING 3' - 6" 4" 6 1/4" FIREPLACE OPENING 3' - 2" 4" 8" 1 3/4" 5' - 9 1/8" 3" LINE OF FAMILY ROOM FIREPLACE FLUE BEYOND @ UNIT A LIVING ROOM LINE OF LIVING ROOM FIREPLACE FLUE BEYOND PROVIDE STEEL ANGLE RE: STRUCT LAG-BOLTED @ EA. END INTO WOOD STRUCTURE TO SUPPORT HEARTH 2ND UNIT MAIN LEVEL FLOOR PLAN FINISHED FLOOR 8162' - 0" 1 3" HEAT & GLO RUTHERFORD 42" FIREPLACE W/ GRAND OAK GAS LOG SET & HERRINGBONE BRICK VENEER 4" STONE VENEER FLUES PER MANUF. 4" CUT STONE HEARTH SET OVER STONE VENEER APRON 3/8" PATINA STEEL PLATE MANTEL PAINTED TO MATCH WINDOW COLOR 4X4 TUBE STEEL POST WELDED TO 1/2"X6"X8" STEEL PLATE AT TOP AND BOTTOM SET IN BED OF SEALANT OVER FLASHING. FASTENED WITH EXPANSION BOLTS INTO STONE ABOVE & BELOW. 3" STONE CAP T.O. STONE CAP @ 8190' - 3" MASON TO PROVIDE DESIGN BUILD ATTACHMENT SYSTEM W/ STEEL ANGLE LAG-BOLTED @ EA. END INTO WOOD STRUCTURE. 6 1/4" X 12" DEEP COLORADO BUFF CUT STONE MANTEL W/ KERF CUT TO RECEIVE STEEL SUPPORT ANGLE 4" COLORADO BUFF CUT STONE SLAB HEARTH. PROVIDE STEEL ANGLE LAG-BOLTED INTO FRAMING TO SUPPORT STONE SLAB A7.2 4 SIM. POCKET DOOR RE: WINDOW SCHEDULE 6 1/4" FIREPLACE OPENING 3' - 2" 4" 8" 1' - 0" 8" 6 1/4" FIREPLACE OPENING 3' - 2" 1' - 0" 8" 2' - 0" Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION As indicated 12/12/2014 3:19:47 PM A7.2 FIREPLACE SHEET Author Checker GORE CREEK RESIDENCES 12/15/14 223 BEAVER DAM RD, VAIL, CO 81657 VAIL VILLAGE FILING 1, BLOCK 7, LOT 39 FINAL DRB SET No. Revision Date Revision Description 1/2" = 1'-0" 1 FIREPLACE ELEVATION - UNIT A OUTDOOR / UNIT B SIM. 1 1/2" = 1'-0" 4 CHIMNEY DETAIL @ LIVING ROOM/OUTDOOR FIREPLACE 1/2" = 1'-0" 3 FIREPLACE PLAN - UNIT B LIVING ROOM/OUTDOOR 1/2" = 1'-0" 2 FIREPLACE ELEVATION - UNIT A LIVING ROOM / UNIT B SIM. 1/2" = 1'-0" 5 FIREPLACE SECTION - UNIT B LIVING/OUTDOOR ROOM E-W SECTION 6 FIREPLACE PERSPECTIVE - UNIT B LIVING ROOM 7 FIREPLACE PERSPECTIVE - UNIT B OUTDOOR DRB APPROVED 2/18/2015 12:00:00 AM