Loading...
HomeMy WebLinkAboutDRB150023_E-101_1423851540.pdf N O O lL Iii iii 116 Z Z : : Z Z I-• I- d Q • 0 cO ValleyCrestDesignGroup 0 iLL LOT 5, BLOCK / ,# Street Den er1645r,,rColorado 80203 VAIL/LIONShEAD �� T/303.825.2010 FIRST FILING �-7 :: �•� 'tilit- • I �`-- VCDesignGroup.com di A-4 `0 EBI l\ ;``','. �1 • EAI '� = \1 CONSULTANTS A-4 — _ A-4 • ► I �.: • - RIVER ENGINEERING ■ ❑EBI • EBI _ r q RiverRestoration EBI❑ / P.O. Box 248 fi — of iaiaai� //a��/a�a�ar�a��rai��rioo, A-4 Carbondale CO 81623 .-4 — — 0 EBI EBI _ _ EAI (970) 947-9568 _ A_ I�II000° CIVIL a STRUCTURAL ENGINEERING r�I11111�I A-4 ,,,,,.■°'"°°°° EBI® _.--- I Loris and Associates, Inc. II 818 W. South Boulder Road, #200 / S�, Louisville I CO 80027 I itEr r.� 4100t. ).....-_,..,,/,4..c .c (303) 444-2073 A--,4:00, TRACT B ELECTRICAL ENGINEERING � VA/L/L/ONSI1AD \ Architectural Engineering /. ) FIRST FILING Design Group, Inc. 190,I ----- _ ���� (3030) 296-3034 Wazee reet, Suite 350 Denver I CO 80202 II / / OWNER I I / Town of Vail I I _ ----- _ �: 75 South Frontage Road 970-479-2337 Vail I CO 81657 1 WEST ELECTRICAL PLAN E-1 01 SCALE: l"=20' LOT C, BLOCK / Z VAIL/LIONShEAD W FIRST FILING , TRACT h, BLOCK / VAIL/LIONShEAD LU - FIRST FILING / 0 / O_ o Lu ce LOT D, BLOCK I J `E) o VAIL/LIONShiAD Ce ce FIRST FILING 1- < > LIGHTING FIXTURE SCHEDULE ABN W ABBREVIATIONS AND SYMBOLS GENERAL NOTES _ _ m TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER VOLTAGE LAMP MAX MOUNTING INFORMATION NOTES HAND HOLE O O W J QTY WATT TYPE WATTS LOCATION BOF/RFD/OFHI. NOT ALL DETAIL NOTES APPLY TO THIS SHEET. i iATT EAI EXTERIOR AREA LIGHT ANP LIGHTING CB12014516.188-PA321-IMOD- 120 I 46 LED 46 POLE 14'0" BOF I BON IN LUGO A AMPERES) UJ LAIg4-H-3-NL-PO46LD4-N-T3-50K-16 BONDING ON AHJ AUTHORITY HAVING JURISDICTION 2. ALL SITE ELECTRICAL DEVICES SHALL BE 16 1.6 EBI EXTERIOR BOLLARD LOUIS POULSEN BYS/311^1 LED/4000K 120 1 31 LED 31 GROUND 45" OFH 1 POLE CIRCUITED WITH A MINIMUM #10G1) HIRE, UNLESS z z 120/211V-GOR-TEN AIG AMPERES INTERRUPTING CAPACITY f BASE COVER OTHERWISE NOTED. REFER TO VOLTAGE DROP > ABBREVIATIONS: BOF - BOTTOM OF FIXTURE, RFD - RECESSED FIXTURE DEPTH,OFH - OVERALL FIXTURE HEIGHT D f G G CONDUIT CALCULATION FOR WIRE SIZE CORRECTIONS I- I- SPECIFIC NOTES: t _ _ DUE TO LONG DISTANCE RUNS. d d W 1 — — CS CIRCUIT BREAKER < < I. EG SHALL VERIFY FIXTURE SPECIFICATION WITH OWNER PRIOR TO PURCHASE. 2" CHAMFER \ } DISC DISCONNECT 3. ALL LIGHTING FIXTURES TO BE CONTROLLED BY O 3-#3 HORIZ. TIES�� } EXISTING PHOTOCELL LOCATED AT ELECTRICAL [VARIES FINISH GRADE EDWG(S) DRAWING(S) PANEL 'A'. GIRGUIT FOR LIGHTS SHALL PASS WITHIN OON OF THROUGH PHOTOCELL BEFORE CONTINUING TO 0PANEL A 1 (E) EXISTING TO REMAIN LIGHT FIXTURES. VOLTAGE L-N: 120 BUS RVOLTAGE L-L: 240 ANG: 100 PEDESTAL \j/\\\j/\ \ / \j\/j//j\/j\/j/%\/,,.//, j\\j\ EG ELECTRICAL CONTRACTOR 4. EG SHALL COORDINATE FINAL LOCATION OF TYPE: IPH/3W MAIN CB: 100 A/2P �-\ ���� jam` ^ ��'v 'v � (R) EXISTING TO BE REMOVED ALL SITE LIGHTING FIXTURES WITH MOUNTING: SURFACE S.G. RATING: TOOK AIG FULLY RATED i\ OWNER/ARGHITEGT PRIOR TO WORK SIGNATURE & SEAL NOTES: EXISTING FED FROM: UTILITY METER ANCHOR BOLT- ATTACH TO FLA FULL LOAD AMPS PERFORMED. �� REBAR WITHG I G GROUND CIR. GCT LOAD LOAD CIRCUIT BRKR BUS CIRCUIT BRKR LOAD LOAD GCT CIR BONDING PVG RIGID CLAMP GG GENERAL CONTRACTOR NO TYPE VA DESCRIPTION POLE TRIP TRIP POLE DESCRIPTION VA TYPE NO F SPARE I 20(*) A 15 I GOIL/CFI 180 R 2 CONDUIT / 3 BUSSED SPACE B 20 I PATH LIGHTS 114 L 4 TMP' / ISG SHORT GIRGUIT CURRENT DETAIL NOTES 5 BUSSED SPACE A BUSSED SPACE 6 ems- KVA KILOVOLT AMPERE(S) \'/ EXISTING PANEL AND METER SHALL REMAIN AT T BUSSED SPACE B BUSSED SPACE 8 THIS LOCATION. EG SHALL DEMOLISH CIRCUIT 4-#4 - KW KILOWATTS) FEEDING EXISTING PATHWAY LIGHTING AND GGT TYPE: L=LIGHTING, R=RECEPTACLE, M=MOTOR,LM=LARGEST MOTOR,E=EQUIPMENT, KE=KITCH EQUIP,S=SUBFEED PANEL BARS RE-CIRCUIT NEW LIGHTING TO SAME CIRCUIT. GGT TYPE: LOAD MULT DEMANDED LOAD TOTAL CONNECTED LOADS VERTICAL LTG LIGHTING REFER TO PANEL 'A' SCHEDULE, SHEET E-101, LIGHTING: 114 1.25 qq3 VA A B MGA MINIMUM CIRCUIT AMPERE(5) FOR MORE INFORMATION. RECEPTACLE: 180 1.0 180 VA VA 160 114 BELOW TOP 5" OVER 10K: O 0.5 0 VA TOTAL DEMANDED LOADS OF FOUNDATION — — MGB MAIN CIRCUIT BREAKER MOTOR: O 1.0 0 VA A B #3 HORIZ. TIES @ 1 LIST MOTOR: O 1.25 0 VA VA 180 qq3 12" 0.G. P POLE EQUIPMENT: O 1.0 0 VA AMPS 2 8 PH, m PHASE REVISIONS KITGH EQUIP: O O 0 VA TOTAL ON I KVA E-. H I SUBFEED PNL: O 1.0 0 VA PANEL: 5 AMPS ELEVATION UON UNLESS OTHERWISE NOTED NOTES: I. BOLD LINEWEIGHT INDICATES NEW OR REVISED LOAD/CIRCUITING. LIGHT LINEWEIGHT INDICATES EXISTING TO REMAIN LOAD/CIRCUITING. (*) EG SHALL VERIFY BREAKER 15 NO LONGER IN USE. PANEL 15 LABELED AS "GATE OPERATOR" BUT THIS DOES NOT EXIST ON PROPERTY. ' EG SHALL SWITCH BREAKER TO OFF POSITION AND RE-LABLE PANEL SCHEDULE. BASE PLATE LIGHTING FIXTURES r.:-;0_0 BOLLARD OR POST TOP LUMINAIRE NO. COMMENTS DATE VOLTAGE DROP CALCULATIONS H EXTERIOR AREA LIGHT SHEET INFORMATION DATE 02.13.2015 TYPICAL CIRCUIT LOAD: 1 AMP PERMISSIBLE VOLTAGE DROP: 5.5 VOLT JOB NUMBER 2869.00 CONDUCTORS PER PHASE: I B y DRAWN BY KMD POWER FACTOR: gO% WIRING DEVICES CHECKED BY BJJ TOP VIEW 1 LENGTH OF RUN: 1040 FT 2g DUPLEX RECEPTACLE NOT FOR CALCULATION: PART I PART 2 FROM ASSOCIATED POLE OVERALL A ANCHOR BOLT DATA D E F G H I (0 PHOTOCELL TABLE* WIRE SIZE (AWG) KEY HEIGHT B SIZE G CONSTRUCTION 1280 155 5qq 21b, I*IO6, VG EAI 14'0" 4" PER MANUFACTURER 0 2 6'0" 6 2 18" 30" EAI 3'Q" II" PER MANUFACTURER 0'2" 4'0" 4'2" 18" 30" * VALUES TAKEN FROM COOPER SUSSMAN 2001 5PD HANDBOOK VOLTAGE p RACEWAY DROP CALCULATIONS TABLE, PAGE 241. DISTRIBUTION AND RACEWAY ELECTRICAL 2 POLE BASE DETAIL SURFACE MTD PANELBOARD WEST PLAN E-101 SCALE NONE 111 TRANSFORMER ® METER E- 1 01 Copyright 2015 ValleyCrest Design Group