HomeMy WebLinkAboutDRB150026_A4-1_1423244700.pdfMAIN LEVEL
FLOOR PLAN
FINISHED FLOOR
46' - 6"
UPPER LEVEL
FLOOR PLAN
FINISHED FLOOR
57' - 6"
LOWER LEVEL
FINISHED FLOOR
34' - 6"
20.0°
3 3/8"
1
A5.13
1
A5.12
1
A5.10
1
A5.11
1
A5.9
1
A5.8
ELECTRICAL UTILITY CLOSET - PROVIDE
P.T. FRAMING AND PLYWOOD SHEATHING
W/ 2X8 P.T. VERTICAL SIDING BUTT
JOINTED OVER ICE AND WATER SHIELD
AIR AND WATER INFILTRATION BARRIER.
STAIN P.T. SIDING TO MATCH TRIM COLOR.
NOTE - P.T. SIDING TO BE SMOOTH FINISH
WITHOUT DIMPLES
GAS METER PAINTED TO
MATCH STONE VENEER
A
B
C D E F
G H I
LINE OF EXISTING GRADE
DIRECTLY BELOW FACE OF
ROOF RAKE
33' BUILDING HEIGHT LIMIT
@ FACE OF ROOF RAKE @
MASTER BATH
BUILDING HEIGHT LIMIT @ 33' - 0" ABOVE EXISTING GRADE
E E
2
8
7
3
3
2
15
17
13
11
15
16
21
22
20
25
11
15
18
9
25
1
11
17
25
19
1
26
19
FINISHED GRADE @ 53' - 1 7/8"
EXISTING GRADE @ 60' - 1 3/8"
BUILDING HEIGHT @ 19' - 9" ABOVE FINISHED GRADE
BUILDING HEIGHT @ 12' - 9 1/2" ABOVE EXISTING GRADE
ROOF EAVE @ 73' - 1 1/8"
33' BUILDING HEIGHT LIMIT @
FACE OF ROOF RAKE @ STAIR
33' BUILDING HEIGHT LIMIT @
FACE OF ROOF RAKE OVER
GARAGE
BUILDING HEIGHT @ 23' - 7 1/4" ABOVE EXISTING GRADEEXISTING GRADE @ 29' - 2 1/8"
FINISHED GRAE @ 32' - 3 3/8"
FINISHED GRAE @ 45' - 3 1/4"
EXISTING GRADE @ 42' - 11 3/8"
28' - 10"
25' - 9"
BUILDING HEIGHT @ 20' - 8 1/2" ABOVE EXISTING GRADE
LINE OF EXISTING GRADE
DIRECTLY BELOW FACE OF
ROOF RAKE @ STAIR
LINE OF EXISTING GRADE
DIRECTLY BELOW FACE OF
ROOF RAKE @ GARAGE
2' - 0"
18
104
4
104B
1
104B
17
104
14
102
15
102
1
205
3
204
4
204
1
106
329
107
113
2' - 6"
5' - 6"
65' - 0"
19' - 0" 3' - 6" 12' - 0" 30' - 6"
8' - 6" 3' - 6" 2' - 6 1/2" 1' - 11 1/2" 26' - 0"
3' - 0"
T.O. WALL @ 62' - 6"
BATHROOM EXHAUST
FAN VENT PAINT TO
MATCH SIDING
7
A6.4
A6.4
8
2' - 2 15/16"
A6.4
9
11
A8.1
1
A8.1
5
A8.1
B.O. HEADER @ 9' - 11 1/4"
B.O. HEADER @ 8' - 3 1/4"
T.O. STEEL BEAM @ 60' - 8 1/2"
T.O. STEEL BEAM @ 57' - 9 1/4"
T.O. STEEL BEAM @ 62' - 2 1/8"
3
A8.1
3
A8.1
4
A8.1
4
A6.3
4
A6.3
11
A8.1
4' - 0"
2' - 0"
10' - 0"
6' - 2"
BATH EXHAUST FAN
PAINT TO MATCH SIDING
6' - 8"
5' - 0"
1' - 2" 115
5
10KW SOLAR ARRAY -
5 ROWS OF 8 PANELS
ATTACHMENT SYSTEM
TO BE CONTRACTOR
DESIGN BUILD PER
TOV SNOW LOAD
REQUIREMENTS
MATERIALS
1. STANDING SEAM METAL ROOF- DARK BROWN CUSTOM COLOR RE: SPEC
2. 2X6 FASCIA - COLOR: PORTER STAINS 709 BLACK WALNUT
3. 6X10 WOOD RAFTERS. RE: STRUCT- COLOR: PORTER STAINS 709 BLACK
WALNUT
4. 6X12 WOOD RAFTERS. RE: STRUCT- COLOR: PORTER STAINS 709 BLACK
WALNUT
5. 4X8 DECKING
6. NOT USED
7. DRY STACKED STONE VENEER- BLEND OF FRED'S BROWN, COLORADO
BUFF, TELLURIDE GOLD, AND ADOBE CHOPPED STONE
8. HORIZONTAL CEDAR WOOD SIDING - W/ 1/4" REVEAL SHIP LAP
9. VERTICAL RECLAIMED WOOD SIDING - NO REVEAL SHIP LAP
10. WOOD 2X4 CORNER TRIM @ HORIZONTAL WOOD SIDING RE: DETAIL
5/A6.3.
11. 3X3 WOOD TRIM- COLOR: PORTER STAINS 709 BLACK WALNUT
12. NOT USED
13. STEEL C-CHANNEL GARAGE DOOR HEADER. RE: STRUCT
14. NOT USED
15. STEEL BEAM. RE: STRUCT
16. 8X8 WOOD STRUT W/ KNIFE PLATE CONNECTIONS @ WALL AND STEEL
BEAM- COLOR: PORTER STAINS 709 BLACK WALNUT
17. 10X10 WOOD COLUMN W/ STEEL CAP AND 4X4 HSS COLUMN CONNECTIONS
@ TOP AND BOTTOM- COLOR: PORTER STAINS 709 BLACK WALNUT
18. TYPICAL STEEL HANDRAIL PAINTED TO MATCH WINDOWS
19. RUBBLE STONE CAP W/ 10 PERCENT MIN. SLOPE AT TOP TO SHED WATER
20. 5" ROUND PFSM GUTTER AND 3" DOWNSPOUT. PIPE UNDERGROUND TO
DAYLIGHT OUTSIDE OF AREA OF EXCAVATION FOR FOUNDATION AND
PROVIDE POWER FOR HEAT TAPE.
21. 4X4 TUBE STEEL COLUMNS @ CHIMNEY CAP PAINTED TO MATCH WINDOW
CLADDING
22. 3" THICK STONE CHIMNEY CAP
23. SNOW FENCE TYP. SEE ROOF PLAN FOR LOCATIONS.
24. SNOW CLIPS TYP. SEE ROOF PLAN FOR LOCATIONS. PROVIDE DESIGN
BUILD SYSTEM.
25. PFSM WRAP @ CORNER TO MATCH WINDOW TYPICAL
26. 4x8 WOOD RAFTERS. RE: STRUCT- COLOR: PORTER STAINS 709 BLACK
WALNUT
27. APPLIED STEEL C-CHANNEL TRIM
28. 8X12 WOOD BEAM. RE: STRUCT- COLOR: PORTER STAINS 709 BLACK
WALNUT
29. 2X DECKING RE: STRUCT
30. 2X12 DECK FRAMING RE: STRUCT
GENERAL NOTES:
1) EXTERIOR LIGHTING IS NOTED AS:
M- HEVI LITE INC HL-374 PAR-20 SURFACE MOUNT DOWN LIGHT BRONZE
POWDER COAT FINISH (BZ)- (13) TOTAL FIXTURES
E- HEVI LITE INC HL-384-BZ SURFACE MOUNT MONO POINT BRONZE POWDER
COAT FINISH. PERMANENTLY FIXED/INSTALLED AS A DOWNLIGHT- (5) TOTAL
FIXTURES
2) SEE EXTERIOR MATERIAL AND COLOR INFORMATION SHEET FOR MORE
INFORMATION ON COLORS. SEE OUTLINE SPEC AND ARCHITECTURAL FINISH
SCHEDULE.
3) ALL SNOW FENCES AT STANDING SEAM ROOF TO BE AN ENGINEERED
SYSTEM PER ROOF TYPE AND SLOPE INSTALLED PER MANUFACTURES
RECOMMENDATIONS RE: SPEC.
4) ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O.
5) WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH.
6) ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO BE
PAINTED TO MATCH BRONZE WINDOW COLOR.
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue
Date
1/28/2015 9:18:56 AM
1/4" = 1'-0"
2722 CORTINA LANE
VAIL RIDGE SUBDIVISION, BLOCK B,
LOT 13 , VAIL CO
A4.1
ELEVATIONS
10-21-14
AG
HB
10-21-14
CONSTRUCTION
DOCUMENTS
0' 2' 4' 8' 16'
1/4" = 1'-0"
1
EAST ELEVATION
REVISION SCHEDULE
# DESCRIPTION DATE
5 ADDED 10KW
SOLAR
ARRAY
1-16-15
DRB
APPROVED
2/6/2015 12:00:00 AM