HomeMy WebLinkAboutDRB150036_L-2 Cut Sh_1423507740.pdfCatalog #
Project
Comments
Prepared by
Type
Date
DESCRIPTION
The Halo RA4 LED Adjustable Gimbal series are retrofit LED
Modules for 4” aperture recessed downlights. The RA4 gimbals
feature adjustment of 35-degree tilt and up to 360-degree rotation.
In addition the RA4 gimbals offer selection of narrow flood (NFL)
and very wide flood (VWFL) models for beam distributions suitable
for accent, task, grazing and general area lighting. The RA4 integral
LED 120V driver is dimmable with most leading edge and trailing
edge phase control dimmers.
SPECIFICATION FEATURES
RA4 LED
Very Wide Flood
(VWFL)
RA4 LED
Narrow Flood
(NFL)
4-Inch
Adjustable Gimbals
All-Purpose Recessed
Retrofit Modules
FOR USE IN INSULATED
CEILING AND NON-
INSULATED
CEILING RATED HOUSINGS
HIGH EFFICACY LED
WITH INTEGRAL DRIVER -
DIMMABLE
www.cooperlighting.com ADV131509
November 15, 2013 3:12 PM
MECHANICAL
• Module includes LED, heat
sink, reflector, lens optic, baffle
reveal, and trim ring• Durable die-cast aluminum
construction
• Integrated heat sink design
conducts heat away from
the LED keeping the junction
temperatures below specified
maximums, even when
installed in insulated ceiling
environments
• Halo matte white paint finish• 35-degree tilt
• Up to 360-degree rotation
Optics
NARROW FLOOD - NFL
• Precision acrylic lens
• Optical design creates a clean,
uniform 25-degree beam
distribution
VERY WIDE FLOOD - VWFL
• Impact-resistant polycarbonate
• Convex form for lamp-like
appearance
• Diffusing, wide beam for even
illumination
MOUNTING
Friction Blades
• Precision formed spring blades
secure module with friction fit
to compatible housings.
• Friction blade design allows
the RA4 to be installed in any
position within the housing
aperture (360 degrees)
Housing Compatibility
See Housing Compatibility
LED
• Color Temperature (CCT)
Options: 2700K, 3000K
• Color Rendering Index (CRI) 90
• LED is a chip on board design
consisting of a multiple
LED package with proximity
phosphor coating to create one
virtual white light source for a
productive “cone of light”
ELECTRICAL
Power Connections
• LED connector is a non-screw
base luminaire disconnect
offering easy installation with
the matching Halo H995 Series
housings.
• LED Connector meets high-
efficacy luminaire requirements
for a non-screw base socket,
and where required to qualify
as a high-efficacy luminaire.
(California Title-24)
• The included E26 medium
screw-base Edison adapter
provides easy retrofit of
incandescent housings (see
Housing Compatibility).
Ground Connection
• Separate grounding cable
included on the module for
attachment to the housing
during installation.
LED Driver
• Dimmable driver is a 120 Volt,
high efficiency, electronic power
supply providing DC power to
the LED.
• Driver meets FCC EMI/RFI
Consumer Level limits for use
in residential and commercial
installations.
• Driver features high power
factor, low THD, and has integral
thermal protection in the event
of over temperature or internal
failure.
• Driver mounts externally to
the module, allowing future
replacement, if needed.
Dimming
• The Halo RA4 LED is designed
for dimming capability to
10% in normal operation with
standard 120V leading edge (LE)
and trailing edge (TE) phase
control dimmers.
• The LED module may also dim
to 5% nominal using dimmers
with low end trim adjustment.
(Consult dimmer manufacturer
for dimmer details. Note, some
dimmers require a neutral in the
wallbox.)
Warranty
Cooper Lighting provides a five
year limited warranty on RA56
LED.
Compliance
Labels
• UL/cUL Listed 1598 Luminaire
(with listed Halo housings)
• UL Classified (with other
housings - see Housing
Compatibility)
• UL/cUL Listed for Damp
Location• May be installed in housings
in direct contact with air
permeable insulation** and
combustible material
Qualification
• ENERGY STAR® qualified
residential and commercial*
• Can be used for State of
California Title 24 high efficacy
luminaire compliance*
• Can be used for Washington
State Energy Code (WSEC)
and International Energy
Conservation Code (IECC) high efficacy luminaire Compliance
IC (Insulated Ceiling)
Listed UL/cUL 1598 with
compatible housings, may be
used to meet insulated ceiling**
requirements such as:
• Washington State Energy Code
(WSEC)
• International Energy
Conservation Code (IECC)
• New York State Energy
Conservation Construction
Code (NY-ECCC)
• State of California Title 24
“Recessed Luminaires in
Insulated Ceilings.”
HALO
2700K nominal
2700K
2725
3000K 3500K 4100K 5000K 6500K
3000K nominal
2700K
3045
3000K 3500K 4100K 5000K 6500K
3500K nominal
2700K
3465
3000K 3500K 4100K 5000K 6500K
4000K nominal
2700K
3985
3000K 3500K 4100K 5000K 6500K
2700K nominal
2700K
2725
3000K 3500K 4100K 5000K 6500K
3000K nominal
2700K
3045
3000K 3500K 4100K 5000K 6500K
3500K nominal
2700K
3465
3000K 3500K 4100K 5000K 6500K
4000K nominal
2700K
3985
3000K 3500K 4100K 5000K 6500K
*Qualified and compliant. Refer to ENERGY STAR® Qualified Products List and CEC (T24) Appliance Database
for listings.
**Not for use with housings in direct contact with spray foam insulation.
L-2
2/8/15
Evans Residence
RA406930WH
LIGHTING FACTS
DIMENSIONS
Ø 5.13”[130mm]
3.3”[86mm]
For further information refer to the Lighting Facts website at http://lightingfacts.com/.
RA406927WH
2700K Source
VWFL Beam
RA406927NFLWH
2700K Source
NFL Beam
RA406930WH
3000K Source
VWFL Beam
RA406930NFLWH
3000K Source
NFL Beam
www.cooperlighting.com
RA4 Series
ENERGY DATA
Minimum Starting Temp: -30°C (-22°F)
EMI/RFI: FCC Title 47 CFR, Part 15, Class B (Consumer)
Sound Rating: Class A standards
Input Voltage: 120V
Power Factor: >0.90
Input Frequency: 50/60Hz
THD: <20%
Input Power: 10W
Input Current: 85mA
Driver-Safety Agency Approvals:
- UL60950-1 Recognized
- LPS output
- UL8750 Compliant
Maximum IC (Insulated Ceiling) Ambient Continuous Operating Temperature: 25°C (77°F)
Maximum Non-IC (NON-Insulated Ceiling) Ambient Continuous Operating Temperature 40°C (104°F)
LED Housing
Series
H995ICAT= 4” LED Insulated Ceiling, AIR-TITE New Construction Housing with LED luminaire connector (high efficacy compliant)H995RICAT= 4” LED Insulated Ceiling, AIR-TITE Remodel Housing with LED luminaire connector (high efficacy compliant)
www.cooperlighting.com
HOUSING COMPATIBILITY
RA4 Series
ORDERING INFORMATION
SAMPLE NUMBER: RA406930WHComplete unit includes RA4 LED and a compatible 4” housing; ordered separately.
RL56 Series Accessory (order separately)
Very Wide Flood - VWFL Models
RA406927WH= 4” LED Adjustable Gimbal, 90CRI, 2700K, White, Very Wide FloodRA406930WH= 4” LED Adjustable Gimbal, 90CRI, 3000K, White, Very Wide Flood
Narrow Flood - NFL Models
RA406927NFLWH= 4” LED Adjustable Gimbal, 90CRI, 2700K, White, Narrow FloodRA406930NFLWH= 4” LED Adjustable Gimbal, 90CRI, 3000K, White, Narrow Flood
HE26LED=Replacement screw base adapter (one included with unit)
RL460WH / RL460SN
UL Listed
UL/cUL Listed for installation in the following Halo
and All-Pro 4” recessed E26 screw based and LED
dedicated housings.
All-Pro™ET400ATSB, ET400RATSB, EI400ATSB
Halo®H99ICAT, H99RTAT, H99TAT, H995ICAT, H995RICAT
UL ClassifiedUL Classified for retrofit in the following 4” recessed
E26 screw based housings.
Utilitech CR04ICAT
Thomas®PS4
Lithonia Lighting®L3, L3R
Commercial Electric™HBR2000B
Juno®TC1, TC1R
Progress Lighting®P830-TG, P832-TG
Juno®, Lithonia Lighting®, Thomas® Lighting, Progress® Lighting, Utilitech, and Commercial Electric™ and their product brand names, where identified above, are tradenames or trademarks of each respective company and Cooper Lighting makes no representations on these trademarks.
RA4 Series
PHOTOMETRY
RA406927WH
Reflector Beam Angle = VWFL Beam (Very Wide Flood)
CCT = 2700K
Spacing Criteria = 1.18
Lumens per Watt = 60 Lm/W
Test No. P121906
Test Model: RA406927WH
RA406930WH
Reflector Beam Angle = VWFL Beam (Very Wide Flood)
CCT = 3000K
Spacing Criteria = 1.18
Lumens per Watt = 61.5 Lm/W
Test No. P121908
Test Model: RA406930WH
Luminance
(Average Candela/M2)
Degree Avg. 0°Luminance
45 43944
55 29652
65 20532
75 15132
85 14648
Luminance
(Average Candela/M2)
Degree Avg. 0°Luminance
45 45015
55 30407
65 21044
75 15551
85 14896
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 225 37.4
0-40 354 58.9
0-60 534 89.0
0-90 600 100
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 230 37.4
0-40 362 58.9
0-60 548 89.0
0-90 615 100
Candela Distribution
DegreesVertical Candela
0* 293
5 293
15 283
25 257
35 206
45 144
55 79
65 40
75 18
85 6
90 0
*CBCP
Candela Distribution
DegreesVertical Candela
0* 301
5 300
15 290
25 263
35 211
45 147
55 81
65 41
75 19
85 6
90 0
*CBCP
Cone of Light Footcandles
35 deg Aiming Angle
Vertical Illuminance on Wall
Distance toIlluminatedPlane
Initial NadirFootcandles
Beam (ft.)
LLength WWidth CB
2'43.5 2.1 2.4 2.9
3'19.3 3.2 3.6 4.3
4'10.9 4.2 4.8 5.7
5'7 5.3 6 7.1
6'4.8 6.4 7.4 8.6
8'2.7 8.6 9.8 11.4
10'1.7 10.8 12.2 14.3
Cone of Light Footcandles
35 deg Aiming Angle
Vertical Illuminance on Wall
Distance toIlluminatedPlane
Initial NadirFootcandles
Beam (ft.)
LLength WWidth CB
2'44.6 2.1 2.4 2.9
3'19.8 3.2 3.6 4.3
4'11.1 4.2 4.8 5.7
5'7.1 5.3 6 7.1
6'5 6.4 7.4 8.6
8'2.8 8.6 9.8 11.4
10'1.8 10.8 12.2 14.3
Cone of Light Footcandles
0 deg Aiming Angle
Horizontal Illuminance on Floor
Distance toIlluminatedPlane
Initial NadirFootcandles
Beam (ft.)
LLength WWidth
5.5'9.7 6.4 6.4
7'6 8.2 8.2
8'4.6 9.4 9.4
9'3.6 10.6 10.6
10'2.9 11.8 11.8
Cone of Light Footcandles
0 deg Aiming Angle
Horizontal Illuminance on Floor
Distance toIlluminatedPlane
Initial NadirFootcandles
Beam (ft.)
LLength WWidth
5.5'9.9 6.4 6.4
7'6.1 8.2 8.2
8'4.7 9.4 9.4
9'3.7 10.6 10.6
10'3 11.8 11.8
Candlepower Distribution
Eyeball at 0-degrees
15º0º
110
220
330
30º
45º
60º
75º
90º
Candlepower Distribution
Eyeball at 0-degrees
15º0º
110
220
330
30º
45º
60º
75º
90º
www.cooperlighting.com
www.cooperlighting.com
RA4 Series
Note: Specifications and Dimensions subject to change without notice.Visit our web site at www.cooperlighting.comCustomer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801
Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049
PHOTOMETRY
RA406927NFLWH
Reflector Beam Angle = NFL Beam (Narrow Flood)
CCT = 2700K
Spacing Criteria = 0.35
Lumens per Watt = 64 Lm/W
Test No. P121904
Test Model: RA406927NFLWH
RA406930NFLWH
Reflector Beam Angle = NFL Beam (Narrow Flood)
CCT = 3000K
Spacing Criteria = 0.35
Lumens per Watt = 64 Lm/W
Test No. P121905
Test Model: RA406930NFLWH
Luminance
(Average Candela/M2)
Degree Avg. 0°Luminance
45 6559
55 3723
65 1726
75 577
85 168
Luminance
(Average Candela/M2)
Degree Avg. 0°Luminance
45 6559
55 3723
65 1726
75 577
85 168
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 556 86.9
0-40 598 93.4
0-60 631 98.7
0-90 640 100
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 556 86.9
0-40 598 93.4
0-60 631 98.7
0-90 640 100
Candela Distribution
DegreesVertical Candela
0* 2985
5 2531
15 836
25 223
35 62
45 27
55 14
65 6
75 2
85 0
90 0
*CBCP
Candela Distribution
DegreesVertical Candela
0* 2985
5 2531
15 836
25 223
35 62
45 27
55 14
65 6
75 2
85 0
90 0
*CBCP
Cone of Light Footcandles
35 deg Aiming Angle
Vertical Illuminance on Wall
Distance toIlluminatedPlane
Initial NadirFootcandles
Beam (ft.)
LLength WWidth CB
2'168 1.7 1 2.9
3'74.7 2.6 1.6 4.3
4'42 3.5 2.2 5.7
5'26.9 4.4 2.8 7.1
6'18.7 5.3 3.4 8.6
8'10.5 7.1 4.4 11.4
10'6.7 8.9 5.6 14.3
Cone of Light Footcandles
35 deg Aiming Angle
Vertical Illuminance on Wall
Distance toIlluminatedPlane
Initial NadirFootcandles
Beam (ft.)
LLength WWidth CB
2'168 1.7 1 2.9
3'74.7 2.6 1.6 4.3
4'42 3.5 2.2 5.7
5'26.9 4.4 2.8 7.1
6'18.7 5.3 3.4 8.6
8'10.5 7.1 4.4 11.4
10'6.7 8.9 5.6 14.3
Cone of Light Footcandles
0 deg Aiming Angle
Horizontal Illuminance on Floor
Distance toIlluminatedPlane
Initial NadirFootcandles
Beam (ft.)
LLength WWidth
5.5'98.7 1.8 1.8
7'60.9 2.4 2.4
8'46.6 2.8 2.8
9'36.9 3 3
10'29.9 3.4 3.4
Cone of Light Footcandles
0 deg Aiming Angle
Horizontal Illuminance on Floor
Distance toIlluminatedPlane
Initial NadirFootcandles
Beam (ft.)
LLength WWidth
5.5'98.7 1.8 1.8
7'60.9 2.4 2.4
8'46.6 2.8 2.8
9'36.9 3 3
10'29.9 3.4 3.4
Candlepower Distribution
Eyeball at 0-degrees
15º0º
1000
2000
3000
30º
45º
60º
75º
90º
Candlepower Distribution
Eyeball at 0-degrees
15º0º
1000
2000
3000
30º
45º
60º
75º
90º