HomeMy WebLinkAboutDRB150036_L-2 Cut Sh_1423507740.pdfCatalog # Project Comments Prepared by Type Date DESCRIPTION The Halo RA4 LED Adjustable Gimbal series are retrofit LED Modules for 4” aperture recessed downlights. The RA4 gimbals feature adjustment of 35-degree tilt and up to 360-degree rotation. In addition the RA4 gimbals offer selection of narrow flood (NFL) and very wide flood (VWFL) models for beam distributions suitable for accent, task, grazing and general area lighting. The RA4 integral LED 120V driver is dimmable with most leading edge and trailing edge phase control dimmers. SPECIFICATION FEATURES RA4 LED Very Wide Flood (VWFL) RA4 LED Narrow Flood (NFL) 4-Inch Adjustable Gimbals All-Purpose Recessed Retrofit Modules FOR USE IN INSULATED CEILING AND NON- INSULATED CEILING RATED HOUSINGS HIGH EFFICACY LED WITH INTEGRAL DRIVER - DIMMABLE www.cooperlighting.com ADV131509 November 15, 2013 3:12 PM MECHANICAL • Module includes LED, heat sink, reflector, lens optic, baffle reveal, and trim ring• Durable die-cast aluminum construction • Integrated heat sink design conducts heat away from the LED keeping the junction temperatures below specified maximums, even when installed in insulated ceiling environments • Halo matte white paint finish• 35-degree tilt • Up to 360-degree rotation Optics NARROW FLOOD - NFL • Precision acrylic lens • Optical design creates a clean, uniform 25-degree beam distribution VERY WIDE FLOOD - VWFL • Impact-resistant polycarbonate • Convex form for lamp-like appearance • Diffusing, wide beam for even illumination MOUNTING Friction Blades • Precision formed spring blades secure module with friction fit to compatible housings. • Friction blade design allows the RA4 to be installed in any position within the housing aperture (360 degrees) Housing Compatibility See Housing Compatibility LED • Color Temperature (CCT) Options: 2700K, 3000K • Color Rendering Index (CRI) 90 • LED is a chip on board design consisting of a multiple LED package with proximity phosphor coating to create one virtual white light source for a productive “cone of light” ELECTRICAL Power Connections • LED connector is a non-screw base luminaire disconnect offering easy installation with the matching Halo H995 Series housings. • LED Connector meets high- efficacy luminaire requirements for a non-screw base socket, and where required to qualify as a high-efficacy luminaire. (California Title-24) • The included E26 medium screw-base Edison adapter provides easy retrofit of incandescent housings (see Housing Compatibility). Ground Connection • Separate grounding cable included on the module for attachment to the housing during installation. LED Driver • Dimmable driver is a 120 Volt, high efficiency, electronic power supply providing DC power to the LED. • Driver meets FCC EMI/RFI Consumer Level limits for use in residential and commercial installations. • Driver features high power factor, low THD, and has integral thermal protection in the event of over temperature or internal failure. • Driver mounts externally to the module, allowing future replacement, if needed. Dimming • The Halo RA4 LED is designed for dimming capability to 10% in normal operation with standard 120V leading edge (LE) and trailing edge (TE) phase control dimmers. • The LED module may also dim to 5% nominal using dimmers with low end trim adjustment. (Consult dimmer manufacturer for dimmer details. Note, some dimmers require a neutral in the wallbox.) Warranty Cooper Lighting provides a five year limited warranty on RA56 LED. Compliance Labels • UL/cUL Listed 1598 Luminaire (with listed Halo housings) • UL Classified (with other housings - see Housing Compatibility) • UL/cUL Listed for Damp Location• May be installed in housings in direct contact with air permeable insulation** and combustible material Qualification • ENERGY STAR® qualified residential and commercial* • Can be used for State of California Title 24 high efficacy luminaire compliance* • Can be used for Washington State Energy Code (WSEC) and International Energy Conservation Code (IECC) high efficacy luminaire Compliance IC (Insulated Ceiling) Listed UL/cUL 1598 with compatible housings, may be used to meet insulated ceiling** requirements such as: • Washington State Energy Code (WSEC) • International Energy Conservation Code (IECC) • New York State Energy Conservation Construction Code (NY-ECCC) • State of California Title 24 “Recessed Luminaires in Insulated Ceilings.” HALO 2700K nominal 2700K 2725 3000K 3500K 4100K 5000K 6500K 3000K nominal 2700K 3045 3000K 3500K 4100K 5000K 6500K 3500K nominal 2700K 3465 3000K 3500K 4100K 5000K 6500K 4000K nominal 2700K 3985 3000K 3500K 4100K 5000K 6500K 2700K nominal 2700K 2725 3000K 3500K 4100K 5000K 6500K 3000K nominal 2700K 3045 3000K 3500K 4100K 5000K 6500K 3500K nominal 2700K 3465 3000K 3500K 4100K 5000K 6500K 4000K nominal 2700K 3985 3000K 3500K 4100K 5000K 6500K *Qualified and compliant. Refer to ENERGY STAR® Qualified Products List and CEC (T24) Appliance Database for listings. **Not for use with housings in direct contact with spray foam insulation. L-2 2/8/15 Evans Residence RA406930WH LIGHTING FACTS DIMENSIONS Ø 5.13”[130mm] 3.3”[86mm] For further information refer to the Lighting Facts website at http://lightingfacts.com/. RA406927WH 2700K Source VWFL Beam RA406927NFLWH 2700K Source NFL Beam RA406930WH 3000K Source VWFL Beam RA406930NFLWH 3000K Source NFL Beam www.cooperlighting.com RA4 Series ENERGY DATA Minimum Starting Temp: -30°C (-22°F) EMI/RFI: FCC Title 47 CFR, Part 15, Class B (Consumer) Sound Rating: Class A standards Input Voltage: 120V Power Factor: >0.90 Input Frequency: 50/60Hz THD: <20% Input Power: 10W Input Current: 85mA Driver-Safety Agency Approvals: - UL60950-1 Recognized - LPS output - UL8750 Compliant Maximum IC (Insulated Ceiling) Ambient Continuous Operating Temperature: 25°C (77°F) Maximum Non-IC (NON-Insulated Ceiling) Ambient Continuous Operating Temperature 40°C (104°F) LED Housing Series H995ICAT= 4” LED Insulated Ceiling, AIR-TITE New Construction Housing with LED luminaire connector (high efficacy compliant)H995RICAT= 4” LED Insulated Ceiling, AIR-TITE Remodel Housing with LED luminaire connector (high efficacy compliant) www.cooperlighting.com HOUSING COMPATIBILITY RA4 Series ORDERING INFORMATION SAMPLE NUMBER: RA406930WHComplete unit includes RA4 LED and a compatible 4” housing; ordered separately. RL56 Series Accessory (order separately) Very Wide Flood - VWFL Models RA406927WH= 4” LED Adjustable Gimbal, 90CRI, 2700K, White, Very Wide FloodRA406930WH= 4” LED Adjustable Gimbal, 90CRI, 3000K, White, Very Wide Flood Narrow Flood - NFL Models RA406927NFLWH= 4” LED Adjustable Gimbal, 90CRI, 2700K, White, Narrow FloodRA406930NFLWH= 4” LED Adjustable Gimbal, 90CRI, 3000K, White, Narrow Flood HE26LED=Replacement screw base adapter (one included with unit) RL460WH / RL460SN UL Listed UL/cUL Listed for installation in the following Halo and All-Pro 4” recessed E26 screw based and LED dedicated housings. All-Pro™ET400ATSB, ET400RATSB, EI400ATSB Halo®H99ICAT, H99RTAT, H99TAT, H995ICAT, H995RICAT UL ClassifiedUL Classified for retrofit in the following 4” recessed E26 screw based housings. Utilitech CR04ICAT Thomas®PS4 Lithonia Lighting®L3, L3R Commercial Electric™HBR2000B Juno®TC1, TC1R Progress Lighting®P830-TG, P832-TG Juno®, Lithonia Lighting®, Thomas® Lighting, Progress® Lighting, Utilitech, and Commercial Electric™ and their product brand names, where identified above, are tradenames or trademarks of each respective company and Cooper Lighting makes no representations on these trademarks. RA4 Series PHOTOMETRY RA406927WH Reflector Beam Angle = VWFL Beam (Very Wide Flood) CCT = 2700K Spacing Criteria = 1.18 Lumens per Watt = 60 Lm/W Test No. P121906 Test Model: RA406927WH RA406930WH Reflector Beam Angle = VWFL Beam (Very Wide Flood) CCT = 3000K Spacing Criteria = 1.18 Lumens per Watt = 61.5 Lm/W Test No. P121908 Test Model: RA406930WH Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 43944 55 29652 65 20532 75 15132 85 14648 Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 45015 55 30407 65 21044 75 15551 85 14896 Zonal Lumen Summary Zone Lumens % Fixture 0-30 225 37.4 0-40 354 58.9 0-60 534 89.0 0-90 600 100 Zonal Lumen Summary Zone Lumens % Fixture 0-30 230 37.4 0-40 362 58.9 0-60 548 89.0 0-90 615 100 Candela Distribution DegreesVertical Candela 0* 293 5 293 15 283 25 257 35 206 45 144 55 79 65 40 75 18 85 6 90 0 *CBCP Candela Distribution DegreesVertical Candela 0* 301 5 300 15 290 25 263 35 211 45 147 55 81 65 41 75 19 85 6 90 0 *CBCP Cone of Light Footcandles 35 deg Aiming Angle Vertical Illuminance on Wall Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) LLength WWidth CB 2'43.5 2.1 2.4 2.9 3'19.3 3.2 3.6 4.3 4'10.9 4.2 4.8 5.7 5'7 5.3 6 7.1 6'4.8 6.4 7.4 8.6 8'2.7 8.6 9.8 11.4 10'1.7 10.8 12.2 14.3 Cone of Light Footcandles 35 deg Aiming Angle Vertical Illuminance on Wall Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) LLength WWidth CB 2'44.6 2.1 2.4 2.9 3'19.8 3.2 3.6 4.3 4'11.1 4.2 4.8 5.7 5'7.1 5.3 6 7.1 6'5 6.4 7.4 8.6 8'2.8 8.6 9.8 11.4 10'1.8 10.8 12.2 14.3 Cone of Light Footcandles 0 deg Aiming Angle Horizontal Illuminance on Floor Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) LLength WWidth 5.5'9.7 6.4 6.4 7'6 8.2 8.2 8'4.6 9.4 9.4 9'3.6 10.6 10.6 10'2.9 11.8 11.8 Cone of Light Footcandles 0 deg Aiming Angle Horizontal Illuminance on Floor Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) LLength WWidth 5.5'9.9 6.4 6.4 7'6.1 8.2 8.2 8'4.7 9.4 9.4 9'3.7 10.6 10.6 10'3 11.8 11.8 Candlepower Distribution Eyeball at 0-degrees 15º0º 110 220 330 30º 45º 60º 75º 90º Candlepower Distribution Eyeball at 0-degrees 15º0º 110 220 330 30º 45º 60º 75º 90º www.cooperlighting.com www.cooperlighting.com RA4 Series Note: Specifications and Dimensions subject to change without notice.Visit our web site at www.cooperlighting.comCustomer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049 PHOTOMETRY RA406927NFLWH Reflector Beam Angle = NFL Beam (Narrow Flood) CCT = 2700K Spacing Criteria = 0.35 Lumens per Watt = 64 Lm/W Test No. P121904 Test Model: RA406927NFLWH RA406930NFLWH Reflector Beam Angle = NFL Beam (Narrow Flood) CCT = 3000K Spacing Criteria = 0.35 Lumens per Watt = 64 Lm/W Test No. P121905 Test Model: RA406930NFLWH Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 6559 55 3723 65 1726 75 577 85 168 Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 6559 55 3723 65 1726 75 577 85 168 Zonal Lumen Summary Zone Lumens % Fixture 0-30 556 86.9 0-40 598 93.4 0-60 631 98.7 0-90 640 100 Zonal Lumen Summary Zone Lumens % Fixture 0-30 556 86.9 0-40 598 93.4 0-60 631 98.7 0-90 640 100 Candela Distribution DegreesVertical Candela 0* 2985 5 2531 15 836 25 223 35 62 45 27 55 14 65 6 75 2 85 0 90 0 *CBCP Candela Distribution DegreesVertical Candela 0* 2985 5 2531 15 836 25 223 35 62 45 27 55 14 65 6 75 2 85 0 90 0 *CBCP Cone of Light Footcandles 35 deg Aiming Angle Vertical Illuminance on Wall Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) LLength WWidth CB 2'168 1.7 1 2.9 3'74.7 2.6 1.6 4.3 4'42 3.5 2.2 5.7 5'26.9 4.4 2.8 7.1 6'18.7 5.3 3.4 8.6 8'10.5 7.1 4.4 11.4 10'6.7 8.9 5.6 14.3 Cone of Light Footcandles 35 deg Aiming Angle Vertical Illuminance on Wall Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) LLength WWidth CB 2'168 1.7 1 2.9 3'74.7 2.6 1.6 4.3 4'42 3.5 2.2 5.7 5'26.9 4.4 2.8 7.1 6'18.7 5.3 3.4 8.6 8'10.5 7.1 4.4 11.4 10'6.7 8.9 5.6 14.3 Cone of Light Footcandles 0 deg Aiming Angle Horizontal Illuminance on Floor Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) LLength WWidth 5.5'98.7 1.8 1.8 7'60.9 2.4 2.4 8'46.6 2.8 2.8 9'36.9 3 3 10'29.9 3.4 3.4 Cone of Light Footcandles 0 deg Aiming Angle Horizontal Illuminance on Floor Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) LLength WWidth 5.5'98.7 1.8 1.8 7'60.9 2.4 2.4 8'46.6 2.8 2.8 9'36.9 3 3 10'29.9 3.4 3.4 Candlepower Distribution Eyeball at 0-degrees 15º0º 1000 2000 3000 30º 45º 60º 75º 90º Candlepower Distribution Eyeball at 0-degrees 15º0º 1000 2000 3000 30º 45º 60º 75º 90º