Loading...
HomeMy WebLinkAboutDRB150045_A3.2_1424899320.pdfUP N36 E24 E26 E28 E30 E32 E34 E36 E38 E40 E42 E44 E46 E48 E50 E52 E54 E56 58 0 E62 N38 N42 +43'-6" +52.16' +52' +52.16' +53 + +45' +43' +43' N40 N34 N30 10% 10% LINE OF DECK @ LOWER LEVEL LINE OF DECK @ MAIN LEVEL LAWN PROPERTY LINE LIMIT OF DISTURBANCEE62 A4.3 A4.1 1 1 A4.2 1 A4.4 1 2' - 6 1/2" 3' - 6" 1' - 7" 8' - 6" 1' - 0" 7' - 6" 7' - 6" 3' - 3" 6' - 3 1/2" 8' - 6" 12' - 0" 13' - 9 1/2" 5' - 9" 23' - 7" 6' - 7 1/2" 2' - 11" 6' - 4 1/4" 3' - 3" 5' KOHLER TEA FOR TWO LIVING ROOM 110 DINING ROOM 103 KITCHEN 104 PANTRY 106 OFFICE 105 MASTER BEDROOM 107 MASTER CLOSET 108 MASTER BATH 109 MUDROOM 111 GARAGE 113 POWDER ROOM 112 ENTRY 101 STAIRS 102 HEAT AND GLO 42" EXCLAIM FIREPLACE 3' - 0" 3' - 10" 1' - 6" LOCKERS HANGING BENCH 4' - 6 1/2" HOOKS W.C. 109C SHOWER 109B WATERFALL EDGE W/D BENCH 1/4" / 12" 1/4" / 12" 1/4" / 12" 3/16" / 12" LAUNDRY CHUTE 1' - 0" 2' - 3" DW BELOW CNTR MICROWAVE HIGH WINDOW ABOVE TV MASONLITE 44" FIREPLACE W/ ICC RIS CHIMNEY AND GAS LOG SET 1' - 6" LINE OF ROOF ABOVE LINE OF ROOF ABOVE LINE OF ROOF ABOVE LINE OF ROOF ABOVE LINE OF ROOF ABOVE BBQ 6' - 1 1/2" 24' - 10 1/2" 27' - 10 1/2" 27' - 6 1/2" LINE OF ROOF ABOVE 5' - 0" 46' - 5" T.O. PLYWOOD @ 46' - 3 3/4" T.O. FINISHED FLOOR @ 46' - 6" 1/4" / 12" 46' - 5" +46'-3" +46.25 46.5' +47' +47.25' 1 A5.3 1 A5.6 7' - 8" 3 1/2" T.O.W. 22' 1 A5.4 TRASH 2' - 10" R.O. 4 1/2" 16' - 3 1/2" 7' - 4 1/2" 8' - 3 7/8" TRASH 8' - 9" MAKE-UP COUNTER 3' - 4" 3' - 3" 4' - 3 1/8" 5' - 6" R.O. 2' - 8 3/8" LINE OF CEILING ABOVE 1 A5.13 1 A5.12 1 7/8" 3' - 11 7/16" TV ABOVE FIREPLACE PROVIDE POWER AND NICHE IN STONE FOR BRACKET 1 A5.5 1 A5.10 1 A5.1 1 A5.2 1 A5.11 1 A5.7 1 A5.9 1 A5.8 FD FD 1/8" / 12" 5/16" / 12" 5/16" / 12" 1/8" / 12" 5/16" / 12" 1/8" / 12" 5/16" / 12" 1/8" / 12" RECLAIMED WOOD SIDING A8.1 6 CONCRETE STEM WALL SUPPORTS DECK AND GRADE. RE: STRUCT 6 A6.1 5 A6.1 2 A6.1 FULL HEIGHT INTERIOR STONE 1 2 3 4 5 6 7 9 10 11 A B C D E F G H I PROPERTY LINE 1" 1" 116 117 118 115 112 110 109 108 107 106 105 104B 103 104 102 101 119 120 113 112 111 111B 106 107 105 109B 109 113 STORAGE 114 11 RISER @ 7 3/16" 10 TREADS @ 10" DOWN CONTINUOUS GRIPABLE HANDRAIL @ 3'-1" ABOVE FINISHED FLOOR AND NOSING 65' - 0" 27' - 11 1/2" 2' - 6 1/2" 12' - 0" 3' - 6" 19' - 0" 8' - 0" 28' - 0" 3' - 0" 1' - 11 1/2" 3' - 6" 8' - 6" 16' - 0" 71' - 9 1/2" 29' - 0" 9' - 8" 12' - 7 1/2" 14' - 5 1/2" 6' - 0 1/2" 5' - 0" 4' - 9" 35' - 3" 26' - 9 1/2" 19' - 3" 5' - 3" 4' - 5" 6' - 4" 6' - 3 1/2" 14' - 5 1/2" 8 19 RISER @ 6 5/8" 18 TREADS @ 10" 2' - 2 7/8" 3' - 0 3/4" R.O. 2' - 8 3/8" 1 1/2" 16' - 4 13/16" R.O. 5 5/8" 10' - 5 1/8" 7" 7" 16' - 4 13/16" R.O. 18' - 3 3/16" 5 7/8" 6' - 0 3/4" R.O. 6' - 11 1/2" 3' - 0 3/4" R.O. 10 1/4" R.O. 2' - 6 3/4" 1' - 3 7/16" 5' - 0 3/4" 5 1/2" 10 11/16" 3' - 0 3/4" R.O. 11' - 0 3/8" 3' - 6 3/4" R.O. 5 1/2" 19' - 4 13/16" 3' - 0 3/4" R.O. 3' - 6 7/16" SLOPED FIREPLACE WALL. WINDOW WIDTH VARIES. SEE SECTION 1/A5.2 5 1/2" 7' - 6 3/4" R.O. 5 1/4" R.O. 3' - 0 3/4" 5 3/4" 1' - 11 1/8" 3' - 0 3/4" R.O. 9' - 5 5/8" 3' - 1 1/4" 9' - 0 3/4" R.O. 5 1/2" 5 1/2" R.O.1' - 6 3/4" 6 1/4" 6 3/4" R.O. 2' - 6 3/4" 2 1/8" R.O. 3' - 2" 2 1/8" R.O. 2' - 6 3/4" 5 1/2" 8" 1' - 11 1/4" 20' - 0" 5' - 4 1/4" 14' - 0" R.O. 3' - 0" 10' - 5 1/2" 2' - 0" 2' - 0" 16' - 5 1/2" 2' - 4" 3' - 9 7/8" 1' - 3 1/2" 3" 5" 15' - 7" 8 1/2" 11' - 3 1/2" 3 15/16" 12' - 0 3/4" 5' - 0 7/16" 2 1/4" 8' - 0" 5' - 0 7/16" 83.2° 96.8° 11' - 8" 4' - 1" 1' - 3 1/2" 4 1/2" 2' - 6" 8" 7' - 2" 4' - 0" 2' - 7 1/2" 4' - 1" 12' - 2 1/2" 6 1/2" R.O. 3' - 0" 6 1/2" 6' - 3 5/8" 1' - 9 3/8" 1" 12' - 2 1/2" 3' - 3" 3' - 11 1/2" 3' - 6" 3' - 8 5/8" 2' - 8 1/2" R.O. 2' - 10" 2' - 11 1/2" 5' - 7" 3' - 6 5/8" 8 7/8" 9" 4' - 3 1/2" 5' - 0" 4' - 9" 35' - 3" 26' - 9 1/2" 26' - 0" 8' - 0" 28' - 0" 3' - 0" 4" HOLD CONCRETE WALL OFF OF PERMANENT SHORING WALL 4" MIN. PROVIDE 5/8" TYPE X GYP @ WALLS, CEILING AND STEEL BEAM IN GARAGE 3 A6.2 CONC. SLAB @ PERIMETER 46' - 5 1/4" CONC. SLAB @ PERIMETER 46' - 5 1/4" CONC. SLAB @ PERIMETER 46' - 5 1/4" CONC. SLAB 46' - 4 1/4" 2 A6.2 1/4" / 12" 6 A6.2 DESIGN BUILD PERMANENT SHORING WALL - TYPICAL SEE FLOOR PLAN FOR ANTICIPATED LOCATION 1 A6.2 3 A6.1 A8.1 11 A6.3 6 A8.1 11 A8.1 11 2' - 0 3/4" 5 7/8" A8.1 11 BOILER AND WATER HEATER VENT IN CHIMNEY 3' - 11" 3' - 9" 3' - 8 1/4" 3 1/2" 3 1/2" 12' - 2" FIREPLACE FRAMING @ T.O. FLOOR 6' - 2 1/8" A7.1 3 6' - 5 3/8" 10' - 3 1/8" 2' - 4 3/4" 3' - 10 1/8" 2X10 WALL @ EXT KITCHEN WALL SEE STAIR SHEET A7.2 FOR ENLARGED FLOORPLAN AND ADDITIONAL INFORMATION 10 A6.3 3' - 0" 1' - 9 3/8" 2' - 8" DOOR HIDDEN IN WOOD SIDING. PROVIDE PUSH LATCH AND HIDDEN HINGES 108 2 1/2" 2 1/2" CONC. SLAB BUILD UP @ LANDING T.O. CONC. STEP @ 47' - 0 5/8" CONTINUOUS GRIPABLE HANDRAIL @ 3'-1" ABOVE NOSING UP 42" TALL HALF WALL 6 5/8" 3" 11 RISER @ 7 1/4" 10 TREADS @ 10" UP 1 A5.14 1 A5.15 12X20.7 C-CHANNEL CLOSED STRINGER RE: STRUCT LINE OF BRIDGE ABOVE 6 16' - 4 7/8" US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 2/23/2015 1:43:56 PM 1/4" = 1'-0" 2722 CORTINA LANE VAIL RIDGE SUBDIVISION, BLOCK B, LOT 13 , VAIL CO A3.2 MAIN LEVEL FLOOR PLAN 10-21-14 AG HB 10-21-14 CONSTRUCTION DOCUMENTS 1/4" = 1'-0" 1 MAIN LEVEL FLOOR PLAN 0' 2' 4' 8' 16' REVISION SCHEDULE # DESCRIPTION DATE 6 GARAGE LOFT BUILD OUT AND STAIR CHANGES 2-18-15 DRB APPROVED 2/25/2015 12:00:00 AM