Loading...
HomeMy WebLinkAboutDRB150045_A4.1_1424899320.pdfMAIN LEVEL FLOOR PLAN FINISHED FLOOR 46' - 6" UPPER LEVEL FLOOR PLAN FINISHED FLOOR 57' - 6" LOWER LEVEL FINISHED FLOOR 34' - 6" 20.0° 3 3/8" 1 A5.13 1 A5.12 1 A5.10 1 A5.11 1 A5.9 1 A5.8 ELECTRICAL UTILITY CLOSET - PROVIDE P.T. FRAMING AND PLYWOOD SHEATHING W/ 2X8 P.T. VERTICAL SIDING BUTT JOINTED OVER ICE AND WATER SHIELD AIR AND WATER INFILTRATION BARRIER. STAIN P.T. SIDING TO MATCH TRIM COLOR. NOTE - P.T. SIDING TO BE SMOOTH FINISH WITHOUT DIMPLES GAS METER PAINTED TO MATCH STONE VENEER A B C D E F G H I LINE OF EXISTING GRADE DIRECTLY BELOW FACE OF ROOF RAKE 33' BUILDING HEIGHT LIMIT @ FACE OF ROOF RAKE @ MASTER BATH BUILDING HEIGHT LIMIT @ 33' - 0" ABOVE EXISTING GRADE E E 2 8 7 3 3 2 15 17 13 11 15 16 21 22 20 25 11 15 18 9 25 1 11 17 25 19 1 26 19 FINISHED GRADE @ 53' - 1 7/8" EXISTING GRADE @ 60' - 1 3/8" BUILDING HEIGHT @ 19' - 9" ABOVE FINISHED GRADE BUILDING HEIGHT @ 12' - 9 1/2" ABOVE EXISTING GRADE ROOF EAVE @ 73' - 1 1/8" 33' BUILDING HEIGHT LIMIT @ FACE OF ROOF RAKE @ STAIR 33' BUILDING HEIGHT LIMIT @ FACE OF ROOF RAKE OVER GARAGE BUILDING HEIGHT @ 23' - 7 1/4" ABOVE EXISTING GRADEEXISTING GRADE @ 29' - 2 1/8" FINISHED GRAE @ 32' - 3 3/8" FINISHED GRAE @ 45' - 3 1/4" EXISTING GRADE @ 42' - 11 3/8" 28' - 10" 25' - 9" BUILDING HEIGHT @ 20' - 8 1/2" ABOVE EXISTING GRADE LINE OF EXISTING GRADE DIRECTLY BELOW FACE OF ROOF RAKE @ STAIR LINE OF EXISTING GRADE DIRECTLY BELOW FACE OF ROOF RAKE @ GARAGE 2' - 0" 18 104 4 104B 1 104B 17 104 14 102 15 102 1 201 1 106 329 107 113 2' - 6" 5' - 6" 65' - 0" 19' - 0" 3' - 6" 12' - 0" 30' - 6" 8' - 6" 3' - 6" 2' - 6 1/2" 1' - 11 1/2" 26' - 0" 3' - 0" T.O. WALL @ 62' - 6" BATHROOM EXHAUST FAN VENT PAINT TO MATCH SIDING 7 A6.4 A6.4 8 2' - 2 15/16" A6.4 9 11 A8.1 1 A8.1 5 A8.1 B.O. HEADER @ 9' - 11 1/4" B.O. HEADER @ 8' - 3 1/4" T.O. STEEL BEAM @ 60' - 8 1/2" T.O. STEEL BEAM @ 57' - 9 1/4" T.O. STEEL BEAM @ 62' - 2 1/8" 3 A8.1 3 A8.1 4 A8.1 4 A6.3 4 A6.3 11 A8.1 4' - 0" 2' - 0" 10' - 0" 6' - 2" BATH EXHAUST FAN PAINT TO MATCH SIDING 6' - 8" 5' - 0" 1' - 2" 115 10KW SOLAR ARRAY - 5 ROWS OF 8 PANELS ATTACHMENT SYSTEM TO BE CONTRACTOR DESIGN BUILD PER TOV SNOW LOAD REQUIREMENTS 1 A5.15 B.O. HEADER @ 5' - 3 1/4" B.O. HEADER @ 13' - 11 5/8" 4 203 3 203 6 MATERIALS 1. STANDING SEAM METAL ROOF- DARK BROWN CUSTOM COLOR RE: SPEC 2. 2X6 FASCIA - COLOR: PORTER STAINS 709 BLACK WALNUT 3. 6X10 WOOD RAFTERS. RE: STRUCT- COLOR: PORTER STAINS 709 BLACK WALNUT 4. 6X12 WOOD RAFTERS. RE: STRUCT- COLOR: PORTER STAINS 709 BLACK WALNUT 5. 4X8 DECKING 6. NOT USED 7. DRY STACKED STONE VENEER- BLEND OF FRED'S BROWN, COLORADO BUFF, TELLURIDE GOLD, AND ADOBE CHOPPED STONE 8. HORIZONTAL CEDAR WOOD SIDING - W/ 1/4" REVEAL SHIP LAP 9. VERTICAL RECLAIMED WOOD SIDING - NO REVEAL SHIP LAP 10. WOOD 2X4 CORNER TRIM @ HORIZONTAL WOOD SIDING RE: DETAIL 5/A6.3. 11. 3X3 WOOD TRIM- COLOR: PORTER STAINS 709 BLACK WALNUT 12. NOT USED 13. STEEL C-CHANNEL GARAGE DOOR HEADER. RE: STRUCT 14. NOT USED 15. STEEL BEAM. RE: STRUCT 16. 8X8 WOOD STRUT W/ KNIFE PLATE CONNECTIONS @ WALL AND STEEL BEAM- COLOR: PORTER STAINS 709 BLACK WALNUT 17. 10X10 WOOD COLUMN W/ STEEL CAP AND 4X4 HSS COLUMN CONNECTIONS @ TOP AND BOTTOM- COLOR: PORTER STAINS 709 BLACK WALNUT 18. TYPICAL STEEL HANDRAIL PAINTED TO MATCH WINDOWS 19. RUBBLE STONE CAP W/ 10 PERCENT MIN. SLOPE AT TOP TO SHED WATER 20. 5" ROUND PFSM GUTTER AND 3" DOWNSPOUT. PIPE UNDERGROUND TO DAYLIGHT OUTSIDE OF AREA OF EXCAVATION FOR FOUNDATION AND PROVIDE POWER FOR HEAT TAPE. 21. 4X4 TUBE STEEL COLUMNS @ CHIMNEY CAP PAINTED TO MATCH WINDOW CLADDING 22. 3" THICK STONE CHIMNEY CAP 23. SNOW FENCE TYP. SEE ROOF PLAN FOR LOCATIONS. 24. SNOW CLIPS TYP. SEE ROOF PLAN FOR LOCATIONS. PROVIDE DESIGN BUILD SYSTEM. 25. PFSM WRAP @ CORNER TO MATCH WINDOW TYPICAL 26. 4x8 WOOD RAFTERS. RE: STRUCT- COLOR: PORTER STAINS 709 BLACK WALNUT 27. APPLIED STEEL C-CHANNEL TRIM 28. 8X12 WOOD BEAM. RE: STRUCT- COLOR: PORTER STAINS 709 BLACK WALNUT 29. 2X DECKING RE: STRUCT 30. 2X12 DECK FRAMING RE: STRUCT GENERAL NOTES: 1) EXTERIOR LIGHTING IS NOTED AS: M- HEVI LITE INC HL-374 PAR-20 SURFACE MOUNT DOWN LIGHT BRONZE POWDER COAT FINISH (BZ)- (13) TOTAL FIXTURES E- HEVI LITE INC HL-384-BZ SURFACE MOUNT MONO POINT BRONZE POWDER COAT FINISH. PERMANENTLY FIXED/INSTALLED AS A DOWNLIGHT- (5) TOTAL FIXTURES 2) SEE EXTERIOR MATERIAL AND COLOR INFORMATION SHEET FOR MORE INFORMATION ON COLORS. SEE OUTLINE SPEC AND ARCHITECTURAL FINISH SCHEDULE. 3) ALL SNOW FENCES AT STANDING SEAM ROOF TO BE AN ENGINEERED SYSTEM PER ROOF TYPE AND SLOPE INSTALLED PER MANUFACTURES RECOMMENDATIONS RE: SPEC. 4) ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O. 5) WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH. 6) ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO BE PAINTED TO MATCH BRONZE WINDOW COLOR. US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 2/23/2015 1:44:20 PM 1/4" = 1'-0" 2722 CORTINA LANE VAIL RIDGE SUBDIVISION, BLOCK B, LOT 13 , VAIL CO A4.1 ELEVATIONS 10-21-14 AG HB 10-21-14 CONSTRUCTION DOCUMENTS 0' 2' 4' 8' 16' 1/4" = 1'-0" 1 EAST ELEVATION REVISION SCHEDULE # DESCRIPTION DATE 6 GARAGE LOFT BUILD OUT AND STAIR CHANGES 2-18-15 DRB APPROVED 2/25/2015 12:00:00 AM