HomeMy WebLinkAboutDRB150049_A4.2_1426113480.pdf2ND UNIT MAIN LEVEL FLOOR PLAN FINISHED FLOOR 8162' - 0" 2ND UNIT UPPER LEVEL FLOOR PLAN FINISHED FLOOR 8174' - 0" 2ND UNIT LOWER LEVEL FINISHED FLOOR 8150' - 0" PRIMARY UNIT LOWER LEVEL FINISHED FLOOR 8147' - 6" PRIMARY UNIT MAIN LEVEL FINISHED FLOOR 8159' - 6" PRIMARY UNIT UPPER LEVEL FINISHED FLOOR 8171' - 6" 2 A5.1 3 A5.1 A B C D E F G H I J K 5 A5.1 2 A5.5 1 A5.4 2 A5.4 2 A5.3 4 A5.5 YY 113 ZZ 113 T 015 S 015 FFFF 016 EE 114 CCC 115 DDD 116 CCC 212 JJJJ 213 KKKK 214 JJ 214 VVV 219 JJJ 121 HHH 121 HHH 121 HHH 121 TRUE ELEVATION OBLIQUE ELEVATION SEE SHEET A4.4 LINE OF 33' ABOVE EXISTING GRADE @ EAVE LINE OF EXISTING GRADE @ EAVE ABOVE T.O. ROOF EAVE @ 8183' - 2" M M M M B Q Q Q Q GAS METER LOCATION MONOPOINTS MOUNTED TO DECK ABOVE 1' - 6" ABOVE GRADE 6' - 6" A.F.F. 1' - 6" A.F.F. 1' - 6" 22 4 A2.0 AAA 113 9' - 2 3/16" R.O. FROM T.O. FINISH 9' - 2 3/16" R.O. FROM T.O. FINISH 12' - 2 3/16" R.O. FROM T.O. FINISH 7' - 6" R.O. FROM T.O. FINISH 2ND UNIT MAIN LEVEL FLOOR PLAN FINISHED FLOOR 8162' - 0" 2ND UNIT UPPER LEVEL FLOOR PLAN FINISHED FLOOR 8174' - 0" 2ND UNIT LOWER LEVEL FINISHED FLOOR 8150' - 0" PRIMARY UNIT LOWER LEVEL FINISHED FLOOR 8147' - 6" PRIMARY UNIT MAIN LEVEL FINISHED FLOOR 8159' - 6" PRIMARY UNIT UPPER LEVEL FINISHED FLOOR 8171' - 6" 2 A5.1 A/C CONDENSING UNITS 3 A5.1 A B C D E F G H I J K 5 A5.1 2 A5.5 1 A5.4 2 A5.4 2 A5.3 4 A5.5 GG 105 III 105 EE 104 E 003 D 003 C 002 659 002 659 001 PP 111 D 111 E 111 E 013 TRUE ELEVATION OBLIQUE ELEVATION SEE SHEET A4.3 9' - 7 1/4" 2' - 10 3/4" 2' - 6" 5' - 4" 14' - 10 9/16" 4' - 8" 1' - 6" 2' - 0" 12' - 7 3/4" 4' - 5 1/8" OBLIQUE ELEVATION SEE SHEET A4.4 Q Q 1' - 6" A.F.F. D 013 HH 105 GENERAL NOTES: 1) EXTERIOR LIGHTING IS NOTED AS: Q-WAC LIGHTING WL-LED100 EXT. STEPLIGHT BRONZE FINISH MOUNTED 18" OR LESS ABOVE FINISHED GRADE- (32) TOTAL FIXTURES B- HUBBARTON FORGE AIRIS SMALL-SEEDED GLASS LENS- 307910-07-ZL222 SURFACE MOUNT DOWN LIGHT - (3) TOTAL FIXTURES M- HEVI LITE INC HL-384-BZ SURFACE MOUNT MONO POINT BRONZE POWDER COAT FINISH. PERMANENTLY FIXED/INSTALLED AS A DOWNLIGHT- (17) TOTAL FIXTURES A4- LIGHTOLIER- CALCULITE EVOLUTION- C4AICLVM- 4" LOW VOLTAGE ADJUSTABLE CAN- (4) TOTAL FIXTURES 2) SEE EXTERIOR MATERIAL AND COLOR INFORMATION SHEET FOR MORE INFORMATION ON COLORS. SEE OUTLINE SPEC AND ARCHITECTURAL FINISH SCHEDULE. 3) ALL SNOW FENCES AT STANDING SEAM ROOF TO BE AN ENGINEERED SYSTEM PER ROOF TYPE AND SLOPE INSTALLED PER MANUFACTURES RECOMMENDATIONS RE: SPEC. 4) ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O. 5) WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH. 6) SEE SHEET A4.1 FOR TYP. MATERIAL CALLOUTS 7) ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO BE PAINTED TO MATCH BLUE/BLACK STEEL SAMPLE. Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 2/25/2015 1:44:22 PM A4.2 ELEVATIONS AG HB GORE CREEK RESIDENCES 02/12/15 223 BEAVER DAM RD, VAIL, CO 81657 VAIL VILLAGE FILING 1, BLOCK 7, LOT 39 REVISED FINAL DRB 1/4" = 1'-0" 1 EAST ELEVATION 1/4" = 1'-0" 2 WEST ELEVATION No. Revision Date Revision Description REPLACED WOOD SIDING WITH COPPER PANELING DRB APPROVED 3/11/2015 12:00:00 AM