HomeMy WebLinkAboutDRB150049_A4.2_1426113480.pdf2ND UNIT MAIN LEVEL FLOOR
PLAN FINISHED FLOOR
8162' - 0"
2ND UNIT UPPER LEVEL FLOOR
PLAN FINISHED FLOOR
8174' - 0"
2ND UNIT LOWER LEVEL
FINISHED FLOOR
8150' - 0"
PRIMARY UNIT LOWER LEVEL
FINISHED FLOOR
8147' - 6"
PRIMARY UNIT MAIN LEVEL
FINISHED FLOOR
8159' - 6"
PRIMARY UNIT UPPER LEVEL
FINISHED FLOOR
8171' - 6"
2
A5.1
3
A5.1
A
B C D E F G H I J K
5
A5.1
2
A5.5
1
A5.4
2
A5.4
2
A5.3
4
A5.5
YY
113
ZZ
113
T
015
S
015
FFFF
016
EE
114
CCC
115
DDD
116
CCC
212
JJJJ
213
KKKK
214
JJ
214
VVV
219
JJJ
121
HHH
121
HHH 121
HHH
121
TRUE ELEVATION
OBLIQUE ELEVATION
SEE SHEET A4.4
LINE OF 33' ABOVE
EXISTING GRADE @
EAVE
LINE OF EXISTING
GRADE @ EAVE
ABOVE
T.O. ROOF EAVE @ 8183' - 2"
M M M M
B
Q
Q
Q
Q
GAS METER LOCATION
MONOPOINTS
MOUNTED TO DECK
ABOVE
1' - 6" ABOVE GRADE
6' - 6" A.F.F.
1' - 6" A.F.F.
1' - 6"
22
4
A2.0
AAA
113
9' - 2 3/16" R.O. FROM T.O. FINISH
9' - 2 3/16" R.O. FROM T.O. FINISH
12' - 2 3/16" R.O. FROM T.O. FINISH
7' - 6" R.O. FROM T.O. FINISH
2ND UNIT MAIN LEVEL FLOOR
PLAN FINISHED FLOOR
8162' - 0"
2ND UNIT UPPER LEVEL FLOOR
PLAN FINISHED FLOOR
8174' - 0"
2ND UNIT LOWER LEVEL
FINISHED FLOOR
8150' - 0"
PRIMARY UNIT LOWER LEVEL
FINISHED FLOOR
8147' - 6"
PRIMARY UNIT MAIN LEVEL
FINISHED FLOOR
8159' - 6"
PRIMARY UNIT UPPER LEVEL
FINISHED FLOOR
8171' - 6"
2
A5.1
A/C CONDENSING UNITS
3
A5.1
A B C D E F G H I J K
5
A5.1
2
A5.5
1
A5.4
2
A5.4
2
A5.3
4
A5.5
GG
105
III
105
EE 104
E
003
D
003
C
002
659
002
659
001
PP
111
D
111
E
111
E 013
TRUE ELEVATION OBLIQUE ELEVATION
SEE SHEET A4.3
9' - 7 1/4" 2' - 10 3/4" 2' - 6" 5' - 4" 14' - 10 9/16" 4' - 8" 1' - 6" 2' - 0" 12' - 7 3/4" 4' - 5 1/8"
OBLIQUE ELEVATION
SEE SHEET A4.4
Q
Q 1' - 6" A.F.F.
D
013
HH
105
GENERAL NOTES:
1) EXTERIOR LIGHTING IS NOTED AS:
Q-WAC LIGHTING WL-LED100 EXT. STEPLIGHT BRONZE FINISH MOUNTED 18"
OR LESS ABOVE FINISHED GRADE- (32) TOTAL FIXTURES
B- HUBBARTON FORGE AIRIS SMALL-SEEDED GLASS LENS- 307910-07-ZL222
SURFACE MOUNT DOWN LIGHT - (3) TOTAL FIXTURES
M- HEVI LITE INC HL-384-BZ SURFACE MOUNT MONO POINT BRONZE POWDER
COAT FINISH. PERMANENTLY FIXED/INSTALLED AS A DOWNLIGHT- (17) TOTAL
FIXTURES
A4- LIGHTOLIER- CALCULITE EVOLUTION- C4AICLVM- 4" LOW VOLTAGE
ADJUSTABLE CAN- (4) TOTAL FIXTURES
2) SEE EXTERIOR MATERIAL AND COLOR INFORMATION SHEET FOR MORE
INFORMATION ON COLORS. SEE OUTLINE SPEC AND ARCHITECTURAL FINISH
SCHEDULE.
3) ALL SNOW FENCES AT STANDING SEAM ROOF TO BE AN ENGINEERED
SYSTEM PER ROOF TYPE AND SLOPE INSTALLED PER MANUFACTURES
RECOMMENDATIONS RE: SPEC.
4) ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O.
5) WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH.
6) SEE SHEET A4.1 FOR TYP. MATERIAL CALLOUTS
7) ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO
BE PAINTED TO MATCH BLUE/BLACK STEEL SAMPLE.
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
2/25/2015 1:44:22 PM
A4.2
ELEVATIONS
AG
HB
GORE CREEK RESIDENCES
02/12/15
223 BEAVER DAM RD, VAIL, CO 81657 VAIL
VILLAGE FILING 1, BLOCK 7, LOT 39
REVISED FINAL DRB
1/4" = 1'-0"
1
EAST ELEVATION
1/4" = 1'-0"
2 WEST ELEVATION
No. Revision Date
Revision
Description
REPLACED
WOOD SIDING
WITH COPPER
PANELING
DRB
APPROVED
3/11/2015 12:00:00 AM