HomeMy WebLinkAboutDRB150078_Cover_1431121380.pdfGeneral Notes:
1. Do not scale drawings.
2. Verify all dimensions, condition, and utility locations prior to beginning any work or ordering
any materials. Notify Fieldscape of any conflicts or discrepancies in the area of construction.
3. In the event that additional details or guidance is needed by the contractor for construction of
any aspect of the project, they shall immediately contact the landscape architect or architect.
4. The general contractor shall be responsible for satisfying all applicable codes and obtaining all
permits and required approvals. This project is governed by the International Building Code and
the International Residential Code. Compliance is mandatory.
5. The general contractor shall verify all existing grades and lay out all proposed improvements for
the landscape architect's approval prior to beginning any site work.
6. It is the intent and meaning of these documents that the general contractor and each
subcontractor provide all labor, materials, transportation, supplies, equipment, etc. to obtain a
complete job within the recognized standards of the industry.
7. All construction is to fit within the available property lines, setbacks, and easements without
creating easements or exceptions to existing restrictions.
8. The general contractor shall field verify the locations of all existing utilities. All utilities shall be
located to minimize excavation and vegatation impacts to the site.
9. The general contractor shall minimize the limits of excavation and take adequate measures to
protect all vegetation beyond the limits of excavation. All areas of disturbance shall be re-vegetated
to blend with the non-disturbed landscape.
10. The general contractor shall verify all site development with the landscape construction
documents. The site plan is for grading and layout; the landscape plan is for planting. Any
discrepancies shall be brought to the attention of the landscape architect.
Project Team:
General Contractor:
Sonnenalp Hotel
20 Vail Road
Vail, Colorado 81657
(970) 479-5470
Contact: Johannes Faessler
Landscape Architect:
Fieldscape Incorporated
P.O. Box 1871
Avon, Colorado 81620
(970) 328-4006
Contact: Ric Fields
Drawing Index
Cover Sheet
Landscape Architecture
L-1 Existing Conditions Plan
L-2 Layout/Snowmelt Plan
L-3 Planting Plan
Sonnenalp Hotel
20 Vail Road, Vail, Colorado 81657
Sonnenalp Subdivision Block 5-E Lot 1
DRB Set
April 22, 2015
DRB
APPROVED
5/8/2015 12:00:00 AM