Loading...
HomeMy WebLinkAboutDRB150081_2015-0407 compliance-report-20150407_134314_581_1428705120.pdfProject Title: Report date: Data filename: P:\Current Projects\15020.00 - Vail Golf Course & Nordic Center Clubhouse\Calculations\COMcheck\VAIL GOLF CLUBHOUSE.cck Page 1 of 2 COMcheck Software Version 3.9.4 Exterior Lighting Compliance Certificate 2009 IECC Section 1: Project Information Project Type: New Construction Project Title : VAIL GOLF AND NORDIC CLUBHOUSE Exterior Lighting Zone: 2 (Residential mixed use area) Construction Site: Owner/Agent: Designer/Contractor: VAIL, CO 81637 STANTON HUMPHRIES AEC AVON, CO 81620 9707488520 STAN@AEC-VAIL.COM Section 2: Exterior Lighting Area/Surface Power Calculation A Exterior Area/Surface B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B x C) F Proposed Watts LOWER LEVEL EAST (Entry canopy) 1000 ft2 0.25 Yes 250 312 LOWER LEVEL NORTH (Other door (not main entry)) 24 ft of door width 20 Yes 480 104 MAIN ENTRY SOUTH (Entry canopy) 475 ft2 0.25 Yes 119 185 BANQUET COVERED PATIOS (Free standing/attached sales canopy) 2121 ft2 0.6 Yes 1273 702 GOLF PATIO (Free standing/attached sales canopy) 1652 ft2 0.6 Yes 991 140 SURROUNDING WALKS (Walkway < 10 feet wide) 800 ft of walkway length 0.7 Yes 560 435 MAIN PARKING (Parking area) 42877 ft2 0.06 Yes 2573 2313 LOADING DOCK (Free standing/attached sales canopy) 150 ft2 0.6 Yes 90 104 Total Tradable Watts* = 6335 4295 Total Allowed Watts = 6335 Total Allowed Supplemental Watts** = 600 * Wattage tradeoffs are only allowed between tradable areas/surfaces. ** A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Section 3: Exterior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) LOWER LEVEL EAST ( Entry canopy 1000 ft2): Tradable Wattage LED 1: DD1: DOWNLIGHT CYLINDER: Other: 1 12 26 312 LOWER LEVEL NORTH ( Other door (not main entry) 24 ft of door width): Tradable Wattage LED 4: DD: RECESSED DOWNLIGHT: Other: 1 4 26 104 MAIN ENTRY SOUTH ( Entry canopy 475 ft2): Tradable Wattage LED 5: DD: RECESSED DOWNLIGHT: Other: 1 4 26 104 LED 6: SS: STEP LIGHT: Other: 1 9 9 81 BANQUET COVERED PATIOS ( Free standing/attached sales canopy 2121 ft2): Tradable Wattage LED 7: DD: RECESSED DOWNLIGHT: Other: 1 20 26 520 LED 8: DD1: DOWNLIGHT CYLINDER: Other: 1 7 26 182 GOLF PATIO ( Free standing/attached sales canopy 1652 ft2): Tradable Wattage LED 9: DD: RECESSED DOWNLIGHT: Other: 1 4 26 104 Project Title: Report date: Data filename: P:\Current Projects\15020.00 - Vail Golf Course & Nordic Center Clubhouse\Calculations\COMcheck\VAIL GOLF CLUBHOUSE.cck Page 2 of 2 LED 10: SS: STEP LIGHT: Other: 1 4 9 36 SURROUNDING WALKS ( Walkway < 10 feet wide 800 ft of walkway length): Tradable Wattage LED 11: CC: BOLLARD: Other: 1 11 30 330 LED 12: BB4: SHORT POLE: Other: 1 1 105 105 MAIN PARKING ( Parking area 42877 ft2): Tradable Wattage LED 2: AA: POLE MOUNTED AREA LIGHT: LED Roadway-Parking Unit 130W: 1 16 138 2208 LED 13: BB4: SHORT POLE: Other: 1 1 105 105 LOADING DOCK ( Free standing/attached sales canopy 150 ft2): Tradable Wattage LED 3: DD: RECESSED DOWNLIGHT: Other: 1 4 26 104 Total Tradable Proposed Watts =4295 Section 4: Requirements Checklist Lighting Wattage: ❑1. Within each non-tradable area/surface, total proposed watts must be less than or equal to total allowed watts. Across all tradable areas/surfaces, total proposed watts must be less than or equal to total allowed watts. Compliance:Passes. Controls, Switching, and Wiring: ❑2. All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt lighting. ❑3. Lighting not designated for dusk-to-dawn operation is controlled by either a a photosensor (with time switch), or an astronomical time switch. ❑4. Lighting designated for dusk-to-dawn operation is controlled by an astronomical time switch or photosensor. ❑5. All time switches are capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. Exterior Lighting Efficacy: ❑6. All exterior building grounds luminaires that operate at greater than 100W have minimum efficacy of 60 lumen/watt. Exceptions: ❑Lighting that has been claimed as exempt and is identified as such in Section 3 table above. ❑Lighting that is specifically designated as required by a health or life safety statue, ordinance, or regulation. ❑Emergency lighting that is automatically off during normal building operation. ❑Lighting that is controlled by motion sensor. Section 5: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2009 IECC requirements in COMcheck Version 3.9.4 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date STANTON HUMPHRIES, PE 4/7/15