Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DRB150093_D1_1433188440.pdf
DATE: TYPE: FIRM NAME: PROJECT: A Division of Hubbell Lighting, Inc. In a continuing effort to offer the best product possible we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product.Web: www.prescolite.com • Tech Support: (888) 777-4832 6" LED Open DownlightLF6LEDG4 120V–277V 0-10V Dimming Ceiling Cutout: 61/4" Maximum Ceiling Thickness 11/4" For conversion to millimeters, multiply inches by 25.4Not to Scale LFR-LED-025 APPLICATIONS: LiteFrame LF6LED is a 6" specification grade LED open downlight that utilizes remote phosphor technology to obtain color consistency, energy savings, and low maintenance costs. 50,000 hours minimum life up to 35ºC (95ºF) in open plenum applications. HOUSING: One-piece 22 gauge non-corrosive steel platform. Pre- wired j-box with snap-on cover for easy access. Snap-in- connection from driver compartment allows easy installation of light engine/trim assembly without tools above or below the ceiling and can be upgraded to accommodate technology improvements. Approve for 8 (4 in/4 out) No. 12 AWG conductors rated for 90ºC through wiring. REFLECTOR: High purity aluminum, Alzak, iridescence suppressed, semi- diffuse upper reflector. Self-trim standard. Painted white self-trim (WT) available as option. Reflector is made from anodized Alanod Miro 4 aluminum. LED LIGHT ENGINE: The LF6LED uses the Philips Fortimo DLM Gen 4 LED Module with remote phosphor technology. This technology provides controlled color consistency (3 SCDM) from fixture to fixture. The system is designed for optional life and lumen maintenance (>50,000 hours at 70% lumen maintenance). Both reflector and light engine assembly are mechanically retained to housing. The light engine comes standard with 80 CRI in all Kelvin temperatures. LED DRIVER: The LF6LED utilizes the Philips Fortimo LED Driver specifically designed to optimize efficiency of the Fortimo DLM Module. Driver is designed to match the 50,000 hour minimum life expectancy of the system. Meets UL Class 2, inherent short circuit protection, self limited, overload protected. If critical temperatures are reached on driver or LED module, integrated thermal feedback loop will gradually reduce current to protect system life. Driver is universal 120V-277V. Optional Lutron Series A driver is also available. DIMMING: Comes standard with 0-10V dimming capability. Flicker-free dimming to 10%. 0-10V control may consume up to 1mA. Lutron 2 wire, 3 wire, and EcoSystem dimming available to 1%. INSTALLATION: Adjustable Bar hangers included. Universal adjustable mounting brackets also accept 1/2" EMT conduit or 1 1/2" or 3/4" lathing channel (by others) or Prescolite 24" bar hangers (B24 or B6). CERTIFICATIONS: CSA certified to US and Canadian safety standards. Suitable for wet locations. Approved for through wiring. Non-IC rated. EM and EMR is damp rated use only. ENERGY STAR qualified with open clear Alzak reflector WARRANTY: 5 year warranty. See www.prescolite.com for details. * See page 5 for EM line art * See page 6 for NCT line art STANDARD 0-10V DIMMINGLUTRON A-SERIES DIMMING TO 1%❑ LF6LEDG46" High Efficacy LED Housing ❑ 6LFLED5G41100 Lumen Module ❑ 6LFLED6G41500 Lumen Module ❑ 6LFLED7G42000 Lumen Module ❑ BlankClear ❑ CGChampagne Gold ❑ BLBlack ❑ WEWheat ❑ LWLight Wheat ❑ PWPewter ❑ WH1 White Paint ❑ WTWhite Trim ❑ TRG6 Trim ring gasket ❑ NCT1,3 Non-conductive trim ❑ EM2,4,6 Pre-punched reflector for integral switch. ❑ AM7,8 Antimicrobal coating on reflector ❑ B24Set of two 24" bar hangers for T-bar ceilings ❑ B6Set of two (2) bar hangers for ceiling joist up to 24" centers ❑ LFSC6 6" reflector screw cover ❑ LFSC6 EM 6" reflector screw cover for EM ❑ SCA6D Sloped ceiling adapter (see note on spec sheet) ❑ Signos6 Architectural glass elements. Refer to specification sheets ARCH-SIG-001 and -003 ❑ LiteGearSee page 4 for availability (not compatible with EM or EMR) ❑ Blank 120V– 277V ❑ 3474 ❑ 30K ❑ 35K ❑ 40K ❑ BlankSemi-Diffuse ❑ HDM5 Lutron 3-wire Eco System to 1% ❑ 2DM5 Lutron 2-wireLeading Edge to 1%(120V only) ❑ EM2,4 Emergency Battery Pack with integral test switch and indicator light ❑ EMR4 Emergency Battery Pack with remote test switch and indicator light ❑ WIHWiHUBB® enabled ❑ Blank Standard 0-10V dimming to 10% ❑ EM2,4,6 Emergency Battery Pack with integral test switch and indicator light ❑ EMR4 Emergency Battery Pack with remote test switch and indicator light ❑ WIHWiHUBB® enabled ❑ LF6LED5G4 ❑ LF6LED6G4 ❑ LF6LED7G4 ❑ 120 ❑ 277 CATALOG NUMBER:EXAMPLE: LF6LEDG4-6LFLED5G430KEXAMPLE: LF6LED7G4120HDM-6LFLED7G435KWHWT Order housing, reflector, and accessories separately HOUSING/LED GENERATION VOLTAGE OPTIONS _TRIM LED COLOR TEMP BEAM ANGLE REF. FINISH REFLECTOR COLORS REF. OPTIONS _ACCESSORIES Use with HDM/2DM dimming option: Match Housing to Trim Output NOTES 1 Requires WT option also 2 EM options required on both housing and trim. Not compatible with FL35 reflector. 3 See page 5 for details 4 347V not available with EM or EMR 5 For HDM & 2DM options, housing output must match trim output 6 Not available with NCT 7 Not available with EM option or NCT. EMR is compatible. 8 Clear Alzak standard. Consult factory for other colors ❑ Blank Nominal 45 degree cutoff ❑ FL357 Nominal 35 degree cutoff FL35 STANDARD 14" 5" 9 1/8" 12 3/4" 5 3/4" 7" 1 1/4" 6 3/8" 8" PHOTOMETRIC DATA Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Boulevard • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-025 • 1/7/15 PHOTOMETRIC DATA LiteFrame - 6" LF6LEDG4 Downlight DRIVER DATA LF6LED5G4 30K LF6LED6G4 30K LF6LED7G4 30K Input Voltage 120-277V 120-277V 120-277V Input Frequency 50/60 Hz 50/60 Hz 50/60 Hz Input Current 0.12A (120v) 0.16A (120v) 0.22A (120v) 0.052 (277v) 0.07A (277v) 0.10A (277v) Input Power 14.5W 19.1W 26.5W Constant Current Output 200–1000mA 200–1000mA 200–1000mA Power Factor ≥0.90 ≥0.90 ≥0.90 THD <20% <20% <20% EMI Filtering FCC 47CFR FCC 47CFR FCC 47CFR Part 15, Class A Part 15, Class A Part 15, Class A Operating Temperature -20ºC to 35ºC -20ºC to 35ºC -20ºC to 35ºC Dimming 0-10V 0-10V 0-10V Over-voltage, over-current, short-circuit protected *Power consumption and photometric output may vary slightly with HDM or 2DM driver. When operating in EM mode, the fixture will deliver approximately 30% of the published full lumen output. 701 Millennium BlvdGreenville, SC 29607 www.hubbelllighting.com NVLAP LAB CODE: 201003-0 ® THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. REPORT NUMBER: 9373 PAGE: 3 OF 8 ISSUE DATE: 07/07/14 PREPARED FOR: PRESCOLITE CATALOG NUMBER: LF6LEDG4 6LFLED5G4FL3530K LUMINAIRE: 6" LiteFrame, Remote Phosphor 3000K, Narrow distribution LAMP CAT. NO.: DLM 1100 10W/830 UL Gen4 LAMP: 1 - Philips Fortimo LED DLM 1100 10W/830 UL Gen4 BALLAST CAT. NO.: XI025C100V036DNM1 BALLAST: 1 - Advance XITANIUM 25W 0.3-1.0A Const. Current Driver MOUNTING: Recessed NOTE: DATA SHOWN IS ABSOLUTE FOR THESAMPLE PROVIDED. DEG CANDELA LUMENS0 12915 134812915 138838425 93241535 114110459115522651175008500900 ZONAL LUMEN SUMMARY ZONE LUMENS %FIXT0- 30928 88.30- 40 1038 98.70- 60105099.90- 90 1051 100.0 90-1800 0.00-180 1051 100.0 TOTAL INPUT WATTS = 14.1 EFFICACY = 74.5 Lm/W CIE TYPE - DIRECT LUMINAIRE SPACING CRITERION = 0.8 LUMINOUS DIAMETER: 5.750 LUMINANCE DATA IN CANDELA/SQ METER ANGLE AVERAGE IN DEG45 759.55 208.65 141.75 0.850. 500 1000 1500 0°15°30° 45° 60° 75° 90° Test No. 9373 Tested at 25ºC Ambient in accordance to IESNA LM-79-2008 LF6LEDG4 6LFLED5G4 30K FL35 LED Light Engine: 3000K, 80 CRI System Wattage: 14.1W Fixture Delivered Lumens: 1051 Fixture Efficacy: 74.5 Spacing Criteria: 0.8 CANDELA DISTRIBUTION DEG CANDELA LUMENS 0 1291 5 1348 129 15 1388 384 25 932 415 35 114 110 45 9 11 55 2 2 65 1 1 75 0 0 85 0 0 90 0 500 1000 1500 0º15º30º 45º 60º 75º 90º LUMINANCE DATA IN CANDELA/SQ. METER Angle in Vertical Average 45°759 55°208 65°141 75°0 85°0 ZONAL LUMEN SUMMARY ZONE LUMENS %LUMINAIRE 0-30 928 88.3 0-40 1038 98.7 0-60 1050 99.9 0-90 1051 100.0 90-180 0 0.0 0-180 1051 100.0 COEFFICIENTS OF UTILIZATION Zonal Cavity Method Room CavityRatio% Effective Ceiling Cavity Reflectance 80%70%50%30%10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 1 114 112 109 107 112 109 107 106 105 104 102 102 100 99 98 97 96 2 109 105 101 98 107 103 100 97 100 97 95 97 95 93 94 93 91 3 104 99 94 91 103 97 93 90 95 91 89 92 90 87 90 88 86 4 100 93 88 84 98 92 88 84 90 86 83 88 85 82 86 83 81 5 96 88 83 79 94 87 82 79 86 81 78 84 80 77 82 79 77 6 91 84 78 74 90 83 78 74 81 77 74 80 76 73 79 75 73 7 88 79 74 70 86 79 74 70 77 73 70 76 72 69 75 72 69 8 84 75 70 66 83 75 70 66 74 69 66 73 69 66 72 68 65 9 80 72 66 63 79 71 66 63 70 66 63 70 65 62 69 65 62 10 77 68 63 60 76 68 63 60 67 63 59 66 62 59 66 62 59 LF6LEDG4 - 6LFLED5G430KFL35 Test No. 9373 LUMINANCE DATA IN CANDELA/SQ. METER Angle in Vertical Average 45°18290 55°382 65°0 75°0 85°0 ZONAL LUMEN SUMMARY ZONE LUMENS %LUMINAIRE 0-30 602 52.0 0-40 967 83.6 0-60 1157 100.0 0-90 1157 100.0 90-180 0 0.0 0-180 1157 100.0 LF6LEDG4 6LFLED5G4 30KLED Light Engine: 3000K, 80 CRISystem Wattage: 14.5WFixture Delivered Lumens: 1157Fixture Efficacy: 80.0 Spacing Criteria: 1.2 CANDELA DISTRIBUTION DEG CANDELA LUMENS 0 719 5 722 69 15 756 212 25 692 321 35 597 365 45 236 181 55 4 8 65 0 0 75 0 0 85 0 0 90 0 0Test No. 8450 2673996-09 Tested at 25ºC Ambient in accordance to IESNA LM-79-2008 % Effective Ceiling Cavity Reflectance 80% 70% 50% 30% 10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 1 113 110 107 105 110 108 105 103 104 102 100 100 98 97 96 95 94 2 107 101 97 93 104 99 95 92 96 93 90 93 90 88 90 88 86 3 100 93 87 83 98 92 87 82 89 85 81 86 83 80 84 81 79 4 94 86 80 75 92 85 79 74 82 77 73 80 76 73 78 75 72 5 88 79 73 68 87 78 72 67 76 71 67 74 70 66 73 69 65 6 83 73 66 61 82 72 66 61 71 65 61 69 64 60 68 63 60 7 78 68 61 56 77 67 61 56 66 60 56 64 59 55 63 59 55 8 74 63 56 51 72 62 56 51 61 55 51 60 55 51 59 54 51 9 69 58 52 47 68 58 52 47 57 51 47 56 51 47 55 50 47 10 65 55 48 44 64 54 48 44 53 47 43 52 47 43 52 47 43Room CavityRatioCOEFFICIENTS OF UTILIZATION Zonal Cavity Method LF6LEDG4 6LFLED5G4 30K Test No. 8450 2673996-09 THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. REPORT NUMBER: 6,878 PAGE: 1 OF 4 ISSUE DATE: 11/11/2013 7:51:06 AM PREPARED FOR: PRESCOLITE LUMINAIRE: LF6LEDG4 WITH 6LFLED5G430K LAMP: JOB NUMBER 2673996 25.3 deg C 0.989 10.11% 0.12 120.13 15:21.4 Stable 0.00 % 0.00 % 1,156.64 DEG CANDELA LUMENS 0 719 5 722 69 15 756 212 25 692 321 35 597 365 45 236 181 55 4 8 65 0 0 75 0 0 85 0 0 90 0 ZONAL LUMEN SUMMARY ZONE LUMENS %FIXT 0- 30 602 52.0 0- 40 967 83.6 0- 60 1157 100.0 0- 90 1157 100.0 90-180 0 0.0 0-180 1157 100.0 TOTAL INPUT WATTS = 14.47 EFFICACY = 80.0 Lm/W CIE TYPE - DIRECT LUMINAIRE SPACING CRITERION = 1.2 LUMINOUS DIAMETER: 6.000 LUMINANCE DATA IN CANDELA/SQ METER ANGLE AVERAGE IN DEG 45 18290. 55 382. 65 0. 75 0. 85 0.Approved Checked 250 500 750 0˚15˚30˚ 45˚ 60˚ 75˚ 90˚ 250 500 750 0º15º30º 45º 60º 75º 90º PHOTOMETRIC DATA Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Boulevard • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-025 • 1/7/15 Hubbell Lighting, Inc. 701 Millennium BlvdGreenville, SC 29607 www.hubbelllighting.com NVLAP LAB CODE: 201003-0 ® THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. REPORT NUMBER: 8683 PAGE:2 OF 7 ISSUE DATE: 03/05/14 PREPARED FOR: PRESCOLITE CATALOG NUMBER: LF6LEDG4 6LFLED6G430K LUMINAIRE: LF6 - 6INCH REMOTE PHOSPHOR, 30K LAMP CAT. NO.: DLM 1500 15W/830 UL Gen4 LAMP: Philips - 3000k Fortimo LED DLM 1500 15W/830 UL Gen4 BALLAST CAT. NO.: XI025C100V036DNM1 BALLAST: 1 - Advance Const. Current Driver MOUNTING: Recessed NOTE: DATA SHOWN IS ABSOLUTE FOR THESAMPLE PROVIDED. ACCREDITED LABORATORY CODE 201003-0 DEG CANDELA LUMENS0 9005 9068715 95426725 87440535 75346145 2932245559651175008500900 ZONAL LUMEN SUMMARYZONE LUMENS %FIXT0-30760 52.20- 40 1221 83.90- 60 1454 99.90- 90 1456 100.090-18000.00-180 1456 100.0 TOTAL INPUT WATTS = 19.1 EFFICACY = 76.2 Lm/W CIE TYPE - DIRECT LUMINAIRE SPACING CRITERION = 1.2 Approved Checked D. ROBBINS P. McCARTHY 350 700 1050 0˚15˚30˚ 45˚ 60˚ 75˚ 90˚ ZONAL LUMEN SUMMARY ZONE LUMENS %LUMINAIRE 0-30 760 52.2 0-40 1221 83.9 0-60 1454 99.9 0-90 1456 100.0 90-180 0 0.0 0-180 1456 100.0 LF6LEDG4 6LFLED6G4 30K LED Light Engine: 3000K, 80 CRI System Wattage: 19.1W Fixture Delivered Lumens: 1456 Fixture Efficacy: 76.2 Spacing Criteria: 1.2 CANDELA DISTRIBUTION DEG CANDELA LUMENS 0 900 5 906 87 15 954 267 25 874 405 35 753 461 45 293 224 55 5 9 65 1 1 75 0 0 85 0 0 90 0Test No. 8683 Tested at 25ºC Ambient in accordance to IESNA LM-79-2008 350 700 1050 0º15º30º 45º 60º 75º 90º COEFFICIENTS OF UTILIZATION Zonal Cavity Method Room CavityRatio% Effective Ceiling Cavity Reflectance80%70%50%30%10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 1 113 110 107 105 110 108 105 103 104 102 100 100 98 97 96 95 94 2 107 101 97 93 104 99 95 92 96 93 90 93 90 88 90 88 86 3 100 93 88 83 98 92 87 82 89 85 81 86 83 80 84 81 79 4 94 86 80 75 92 85 79 74 82 77 73 80 76 73 78 75 72 5 89 79 73 68 87 78 72 67 76 71 67 75 70 66 73 69 66 6 83 73 66 62 82 72 66 61 71 65 61 69 64 60 68 63 60 7 78 68 61 56 77 67 61 56 66 60 56 64 59 55 63 59 55 8 74 63 56 52 72 62 56 51 61 55 51 60 55 51 59 54 51 9 69 59 52 47 68 58 52 47 57 51 47 56 51 47 55 50 47 10 65 55 48 44 64 54 48 44 53 47 43 52 47 43 52 47 43 LF6LEDG4 6LFLED6G4 30K Test No.8683 701 Millennium BlvdGreenville, SC 29607www.hubbelllighting.com NVLAP LAB CODE: 201003-0 ® THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. REPORT NUMBER: 9372 PAGE: 3 OF 8 ISSUE DATE: 07/07/14 PREPARED FOR: PRESCOLITE CATALOG NUMBER: LF6LEDG4 6LFLED6G4FL3530K LUMINAIRE: 6" LiteFrame, Remote Phosphor 3000K, Narrow distribution LAMP CAT. NO.: DLM 1500 15W/830 UL Gen4 LAMP: 1 - Philips Fortimo LED DLM 1500 15W/830 UL Gen4 BALLAST CAT. NO.: XI025C100V036DNM1 BALLAST: 1 - Advance XITANIUM 25W 0.3-1.0A Const. Current Driver MOUNTING: Recessed NOTE: DATA SHOWN IS ABSOLUTE FOR THESAMPLE PROVIDED. DEG CANDELA LUMENS0 15175 159315315 164845625 111849535 1381314511135522651175008500900 ZONAL LUMEN SUMMARY ZONE LUMENS %FIXT0- 30 1105 88.30- 40 123598.70- 601250 99.90- 90 1251 100.0 90-1800 0.00-180 1251100.0 TOTAL INPUT WATTS = 18.7 EFFICACY = 66.9 Lm/W CIE TYPE - DIRECT LUMINAIRE SPACING CRITERION = 0.8 LUMINOUS DIAMETER: 5.750 LUMINANCE DATA IN CANDELA/SQ METER ANGLE AVERAGE IN DEG45 928.55 208.65 141.750.85 0. 550 1100 1650 0°15°30° 45° 60° 75° 90° Test No. 9372 Tested at 25ºC Ambient in accordance to IESNA LM-79-2008 LF6LEDG4 6LFLED6G4 30K FL35LED Light Engine: 3000K, 80 CRISystem Wattage: 18.7WFixture Delivered Lumens: 1251Fixture Efficacy: 66.9Spacing Criteria: 0.8 CANDELA DISTRIBUTION DEG CANDELA LUMENS 0 1517 5 1593 153 15 1648 456 25 1118 495 35 138 131 45 11 13 55 2 2 65 1 1 75 0 0 85 0 0 90 0 550 1100 1650 0º15º30º 45º 60º 75º 90º LUMINANCE DATA IN CANDELA/SQ. METER Angle in Vertical Average 45°928 55°208 65°141 75°0 85°0 ZONAL LUMEN SUMMARY ZONE LUMENS %LUMINAIRE 0-30 1105 88.3 0-40 1235 98.7 0-60 1250 99.9 0-90 1251 100.0 90-180 0 0.0 0-180 1251 100.0 COEFFICIENTS OF UTILIZATION Zonal Cavity Method Room CavityRatio% Effective Ceiling Cavity Reflectance80%70%50%30%10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 1 114 112 109 107 112 109 107 106 105 104 102 102 100 99 98 97 96 2 109 105 101 98 107 103 100 97 100 97 95 97 95 93 94 93 91 3 104 99 94 91 103 97 93 90 95 91 89 92 90 87 90 88 86 4 100 93 88 84 98 92 88 84 90 86 83 88 85 82 86 83 81 5 96 88 83 79 94 87 82 79 86 81 78 84 80 77 82 79 77 6 91 84 78 74 90 83 78 74 81 77 74 80 76 73 79 75 73 7 88 79 74 70 86 79 74 70 77 73 70 76 72 69 75 72 69 8 84 75 70 66 83 75 70 66 74 69 66 73 69 66 72 68 65 9 80 72 66 63 79 71 66 63 70 66 62 69 65 62 69 65 62 10 77 68 63 60 76 68 63 60 67 63 59 66 62 59 66 62 59 LF6LEDG4 - 6LFLED6G430K FL35 Test No. 9372 PHOTOMETRIC DATA Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Boulevard • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-025 • 1/7/15 701 Millennium BlvdGreenville, SC 29607www.hubbelllighting.com NVLAP LAB CODE: 201003-0 ® THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. REPORT NUMBER: 9314 PAGE: 3 OF 8 ISSUE DATE: 07/02/14 PREPARED FOR: PRESCOLITE CATALOG NUMBER: LF6LEDG4 6LFLED7G4FL3530K LUMINAIRE: 6inch LiteFrame, Remote Phosphor 3000K, Narrow distribution LAMP CAT. NO.: DLM 2000 21W/830 UL Gen4 LAMP: 1 - Philips Fortimo LED DLM 2000 21W/830 UL Gen4 BALLAST CAT. NO.: XI025C100V036DNM1 BALLAST: 1 - Advance XITANIUM 25W 0.3-1.0A Const. Current Driver MOUNTING: Recessed NOTE: DATA SHOWN IS ABSOLUTE FOR THESAMPLE PROVIDED. DEG CANDELA LUMENS0 22605 237022815 245167925 166374035 2111994517195543651175118500900 ZONAL LUMEN SUMMARY ZONE LUMENS %FIXT0- 30 1646 88.00- 40 184598.70- 601868 99.90- 90 1870 100.0 90-1800 0.00-180 1870100.0 TOTAL INPUT WATTS = 26.0 EFFICACY = 71.9 Lm/W CIE TYPE - DIRECT LUMINAIRE SPACING CRITERION = 0.8 LUMINOUS DIAMETER: 5.750 LUMINANCE DATA IN CANDELA/SQ METER ANGLE AVERAGE IN DEG45 1435.55 416.65 141.75 231.850. 800 1600 2400 0°15°30° 45° 60° 75° 90° Test No. 9314 Tested at 25ºC Ambient in accordance to IESNA LM-79-2008 LF6LEDG4 6LFLED7G4 30K FL35 LED Light Engine: 3000K, 80 CRI System Wattage: 26.0W Fixture Delivered Lumens: 1870 Fixture Efficacy: 71.9 Spacing Criteria: 0.8 CANDELA DISTRIBUTION DEG CANDELA LUMENS 0 2260 5 2370 228 15 2451 679 25 1663 740 35 211 199 45 17 19 55 4 3 65 1 1 75 1 1 85 0 0 90 0 800 1600 2400 0º15º30º 45º 60º 75º 90º LUMINANCE DATA IN CANDELA/SQ. METER Angle in Vertical Average 45°1435 55°416 65°141 75°231 85°0 ZONAL LUMEN SUMMARY ZONE LUMENS %LUMINAIRE 0-30 1646 88.0 0-40 1845 98.7 0-60 1868 99.9 0-90 1870 100.0 90-180 0 0.0 0-180 1870 100.0 COEFFICIENTS OF UTILIZATION Zonal Cavity Method Room CavityRatio% Effective Ceiling Cavity Reflectance 80%70%50%30%10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 1 114 112 109 107 112 109 107 106 105 104 102 102 100 99 98 97 96 2 109 105 101 98 107 103 100 97 100 97 95 97 95 93 94 92 91 3 104 99 94 91 103 97 93 90 95 91 89 92 90 87 90 88 86 4 100 93 88 84 98 92 87 84 90 86 83 88 85 82 86 83 81 5 96 88 83 79 94 87 82 79 85 81 78 84 80 77 82 79 77 6 91 83 78 74 90 83 78 74 81 77 74 80 76 73 79 75 73 7 87 79 74 70 86 79 73 70 77 73 69 76 72 69 75 71 69 8 84 75 70 66 83 75 70 66 74 69 66 73 69 65 72 68 65 9 80 72 66 63 79 71 66 63 70 66 62 69 65 62 69 65 62 10 77 68 63 59 76 68 63 59 67 62 59 66 62 59 66 62 59 LF6LEDG4 - 6LFLED7G430K FL35 Test No. 9314 THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. REPORT NUMBER: 6,869 PAGE: 1 OF 4 ISSUE DATE: 11/7/2013 4:43:07 PM PREPARED FOR: PRESCOLITE LUMINAIRE: LF6LEDG4 WITH 6LFLED7G430K 25.7 deg C 0.996 6.83% 0.22 120.14 27:32.5 Stable 0.04 % 0.49 % 2,011.90 DEG CANDELA LUMENS 0 1263 5 1267 122 15 1320 370 25 1212 561 35 1041 637 45 391 306 55 9 15 65 2 2 75 0 0 85 0 0 90 0 ZONAL LUMEN SUMMARY ZONE LUMENS %FIXT 0- 30 1053 52.3 0- 40 1690 83.9 0- 60 2011 99.9 0- 90 2013 100.0 90-180 0 0.0 0-180 2013 100.0 TOTAL INPUT WATTS = 26.44 EFFICACY = 76.1 Lm/W CIE TYPE - DIRECT LUMINAIRE SPACING CRITERION = 1.2 LUMINOUS DIAMETER: 6.000 LUMINANCE DATA IN CANDELA/SQ METER ANGLE AVERAGE IN DEG 45 30302. 55 860. 65 259. 75 0. 85 0. Approved Checked 450 900 1350 0˚15˚30˚ 45˚ 60˚ 75˚ 90˚ Test No. 8453 2673996-08 Tested at 25ºC Ambient in accordance to IESNA LM-79-2008 LF6LEDG4 6LFLED7G4 30K LED Light Engine: 3000K, 80 CRI System Wattage: 26.4W Fixture Delivered Lumens: 2013 Fixture Efficacy: 76.1 Spacing Criteria: 1.2 CANDELA DISTRIBUTION DEG CANDELA LUMENS 0 1263 5 1267 122 15 1320 370 25 1212 561 35 1041 637 45 391 306 55 9 15 65 2 2 75 0 0 85 0 0 90 0 450 900 1350 0º15º30º 45º 60º 75º 90º LUMINANCE DATA IN CANDELA/SQ. METER Angle in Vertical Average 45°30302 55°860 65°259 75°0 85°0 ZONAL LUMEN SUMMARY ZONE LUMENS %LUMINAIRE 0-30 1053 52.3 0-40 1690 83.9 0-60 2011 99.9 0-90 2013 100.0 90-180 0 0.0 0-180 2013 100.0 % Effective Ceiling Cavity Reflectance 80% 70% 50% 30% 10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 1 113 110 107 105 110 108 105 103 104 102 100 100 98 97 96 95 94 2 107 101 97 93 104 99 95 92 96 93 90 93 90 88 90 88 86 3 100 93 88 83 98 92 87 82 89 85 81 86 83 80 84 81 79 4 94 86 80 75 92 85 79 74 82 77 73 80 76 73 78 75 72 5 89 79 73 68 87 78 72 67 76 71 67 75 70 66 73 69 66 6 83 73 66 62 82 72 66 61 71 65 61 69 64 60 68 63 60 7 78 68 61 56 77 67 61 56 66 60 56 64 59 55 63 59 55 8 74 63 56 52 72 62 56 51 61 55 51 60 55 51 59 54 51 9 69 59 52 47 68 58 52 47 57 51 47 56 51 47 55 50 47 10 66 55 48 44 64 54 48 44 53 48 44 52 47 43 52 47 43Room CavityRatioCOEFFICIENTS OF UTILIZATION Zonal Cavity Method LF6LEDG4 6LFLED7G4 30K Test No. 8453 2673996-08 PHOTOMETRIC DATA Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Boulevard • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-025 • 1/7/15 LiteFrame - 6" LF6LEDG4 Downlight EM/EMR DIMENSIONS Central Inverters For fixture full light output in back-up mode, Prescolite and Dual-lite have jointly tested the LiteFrame LED with the 100 (LG1) and 250 (LG2) VA LiteGear invert- ers. (Note: Not for use with integral EM option). For more information on LiteGear go to www.dual-lite.com/resources/litegear_luminaire_loading_chart/ wiHUBB® Fixture comes with a pre-installed In-Fixture Module (1 relay, 0-10V) compatible with the HBA wiHUBB system. Actual dimming requires the selection of 0-10V dimming ballast as well. Consult factory for compatibility with EM fixtures. NOTES: When ordering a sloped ceiling adapter, specify the degree of slope in 5º increments, max. of 35º. For a more precise degree or wet ceiling applications, please contact factory. Sloped ceiling adapter and housing must be installed at the same time. Dimming Compatibility Table Dimming Ballast Manufacturer Web Link DM/DM1 Lutron DVTV http://bit.ly/11jSvZg DM/DM1 Leviton AWRMG-7xx, AWSMG-7xx, AWSMT-7xx http://bit.ly/1BJn2R9 HDM Lutron http://bit.ly/1vtjHAl 2DM Lutron http://bit.ly/1nF4Zp1 PHOTOMETRIC DATA Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Boulevard • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-025 • 1/7/15 NCT Non-Conductive Trim. Standard with Solite lens. 5 14 3 1/2 9 7 3/4 5"9" 3-1/2" 7-3/4" 14" 1/2" A(See pg.1)