HomeMy WebLinkAboutDRB150160_Galatyn Lodge cutsheets_1430853780.pdfUnit Report For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Unit Information Tag Name:25T CH 4.23.15 Model Number:30RAP025 Condenser Type:Air Cooled Compressor Type:Scroll Nameplate Voltage:208/230-3-60 V-Ph-Hz Quantity:1 Manufacturing Source:Charlotte, NC USA Refrigerant:R410A Independent Refrigerant Circuits:1 Capacity Control Steps:22 Minimum Capacity:17.0 % Shipping Weight:1328 lb Operating Weight:1242 lb Unit Length:89 in Unit Width:41 in Unit Height:79 in Accessories and Installed Options Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point Wind Baffle Security Grilles/Hail Guards Motormaster® V Low Ambient Kit. Operation down to -20° F (- 29° C). Low Sound Compressor Blankets Vibration Isolation Package Chiller Warranty Information (Note: for US & Canada only) First Year - Parts Only (Standard) Complete Unit Less Hydronic System Years 2-5 Parts Only Ordering Information Part Number Description Quantity 30RAP0255F-02100 Packaged Chiller 1 Base Unit Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point 30RA-900---066 Wind Baffle 1 38AP-900---003 Security Grilles/Hail Guards 1 38AP-900---020 Motormaster® V Low Ambient Kit. Operation down to -20° F (-29° C). 1 38AP-900---009 Low Sound Compressor Blankets 2 30RA-900---005 Vibration Isolation Package 1 Packaged Chiller Builder NACO 3.49j Page 1 of 10 Certified Drawing for 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Packaged Chiller Builder NACO 3.49j Page 2 of 10 Field Wiring Diagram for 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Packaged Chiller Builder NACO 3.49j Page 3 of 10 Summary Performance Report For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM PackagedChillerReport:DoNotEdit; AquaSnapTM Air-Cooled Scroll Chiller Unit Information Tag Name:25T CH 4.23.15 Model Number:30RAP025 Quantity:1 Manufacturing Source:Charlotte, NC USA Refrigerant:R410A Independent Refrigerant Circuits:1 Shipping Weight:1328 lb Operating Weight:1242 lb Unit Length:89 in Unit Width:41 in Unit Height:79 in Chiller Pressure Drop*:28.6 ft wg *Use Chiller Pressure Drop for sizing pumps. This value includes losses due to chiller piping, fittings, 40 mesh factory supplied strainer and BPHX. Evaporator Information Fluid Type:Propylene Glycol Brine Concentration:50.0 % Fouling Factor:0.00010 (hr-sqft-F)/BTU Leaving Temperature:44.0 °F Entering Temperature:54.0 °F Fluid Flow:57.0 gpm Evaporator Pressure Drop*:20.7 ft wg *Refer to Chiller Pressure Drop for sizing pumps. Condenser Information Altitude:8500 ft Number of Fans:2 Total Condenser Fan Air Flow:19400 CFM Entering Air Temperature:95.0 °F Integrated Pump Information No Pump Selected Performance Information Cooling Capacity:21.0 Tons Total Compressor Power:25.2 kW Total Fan Motor Power:2.04 kW Total Unit Power (without pump):27.3 kW Efficiency (without pump):9.26 EER IPLV:15.14 EER Accessories and Installed Options Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point Wind Baffle Security Grilles/Hail Guards Motormaster® V Low Ambient Kit. Operation down to -20° F (- 29° C). Low Sound Compressor Blankets Vibration Isolation Package Electrical Information Unit Voltage:208/230-3-60 V-Ph-Hz Connection Type:Single Point Electrical Electrical Amps Circuit 1 Circuit 2 MCA 127.4 --- MOCP 175.0 --- ICF 363.3 --- Rec Fuse Size 150.0 --- Sound power measured in accordance with ANSI/AHRI Standard 370-2001. Packaged Chiller Builder NACO 3.49j Page 4 of 10 Summary Performance Report For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Evaporator contains a glycol or other secondary coolants for freeze protection with a leaving chilled fluid temperature above 32°F and is certified in accordance with the AHRI Air-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI) when tested with water at Standard Rating Conditions. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Packaged Chiller Builder NACO 3.49j Page 5 of 10 Summary Performance Report For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Unit Parameters Tag Name:25T CH 4.23.15 Model Number:30RAP025 Condenser Type:Air Cooled Compressor Type:Scroll Chiller Nameplate Voltage:208/230-3-60 V-Ph-Hz Quantity:1 Manufacturing Source:Charlotte, NC USA Refrigerant:R410A Shipping Weight:1328 lb Operating Weight:1242 lb Unit Length:89 in Unit Width:41 in Unit Height:79 in 1 - Chiller Height Above Ground 2 - Horizontal Distance From Chiller to Receiver 3 - Receiver Height Above Ground (See Note 3) Accessories and Installed Options Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point Wind Baffle Security Grilles/Hail Guards Motormaster® V Low Ambient Kit. Operation down to -20° F (- 29° C). Low Sound Compressor Blankets Vibration Isolation Package Acoustic Information Table 1. A-Weighted Sound Power Levels (dB re 1 picowatt). See note #1. Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall 100% Load 37 58 68 78 83 84 83 77 67 89 75% Load 37 58 68 78 83 84 83 77 67 89 50% Load 37 58 68 78 83 84 82 77 67 88 25% Load 34 55 65 75 80 81 80 74 64 86 Table 2. A-Weighted Sound Pressure Levels (dB re 20 micropascals) calculated based upon user defined input for dimensions 1, 2 and 3 as shown in above diagram. See note #2 and #3. Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall 100% Load 10 31 40 50 55 56 55 49 40 61 75% Load 10 31 40 50 55 56 55 49 40 61 50% Load 10 30 40 50 55 56 55 49 40 61 25% Load 7 28 37 47 52 53 52 46 37 58 Notes: (1) Measurements performed in accordance with AHRI Standard 370 for air cooled Chillers. (2) Chiller is assumed to be a point source on a reflecting plane. (3) Without user defined input, the default dimensions used to construct Table 2 are as follows: 1 - Chiller Height Above Ground = 0.0 ft 2 - Horizontal Distance From Chiller to Receiver = 30.0 ft 3 - Receiver Height Above Ground = 3.0 ft Packaged Chiller Builder NACO 3.49j Page 6 of 10 Acoustic Summary For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM PackagedChillerReport:DoNotEdit; Please refer to Performance Output Summary or Detailed Performance Report for Acoustic information Packaged Chiller Builder NACO 3.49j Page 7 of 10 Detailed Performance Summary For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM PackagedChillerReport:DoNotEdit; Unit Information Tag Name:25T CH 4.23.15 Model Number:30RAP025 Condenser Type:Air Cooled Compressor Type:Scroll Nameplate Voltage:208/230-3-60 V-Ph-Hz Quantity:1 Manufacturing Source:Charlotte, NC USA Refrigerant:R410A Capacity Control Steps:22 Minimum Capacity:17.0 % Shipping Weight:1328 lb Operating Weight:1242 lb Unit Length:89 in Unit Width:41 in Unit Height:79 in Minimum Outdoor Operating Temp:45 °F Chiller Pressure Drop*:28.6 ft wg *Use Chiller Pressure Drop for sizing pumps. This value includes losses due to chiller piping, fittings, 40 mesh factory supplied strainer and BPHX. Performance Information Cooling Capacity:21.0 Tons Total Compressor Power:25.2 kW Total Fan Motor Power:2.04 kW Total Unit Power (without pump):27.3 kW Efficiency (without pump):9.26 EER Evaporator Information Fluid Type:Propylene Glycol Brine Concentration:50.0 % Fouling Factor:0.00010 (hr-sqft-F)/BTU Leaving Temperature:44.0 °F Entering Temperature:54.0 °F Fluid Flow:57.0 gpm Evaporator Pressure Drop*:20.7 ft wg *Refer to Chiller Pressure Drop for sizing pumps. Condenser Information Altitude:8500 ft Number of Fans:2 Total Condenser Fan Air Flow:19400 CFM Entering Air Temperature:95.0 °F Integrated Pump Information No Pump Selected Accessories and Installed Options Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point Wind Baffle Security Grilles/Hail Guards Motormaster® V Low Ambient Kit. Operation down to -20° F (- 29° C). Low Sound Compressor Blankets Vibration Isolation Package Electrical Information Unit Voltage:208/230-3-60 V-Ph-Hz Connection Type:Single Point Electrical Electrical Amps Circuit 1 Circuit 2 MCA 127.4 --- MOCP 175.0 --- ICF 363.3 --- Rec Fuse Size 150.0 --- Packaged Chiller Builder NACO 3.49j Page 8 of 10 Detailed Performance Summary For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Integrated Part Load Value (AHRI) IPLV:15.14 EER Unit Performance Percent of Full Load Capacity, %100 75 50 25 Percent of Full Load Power, %100.0 55.7 31.1 14.9 Unloading Sequence A A A A Cooling Capacity, Tons 23.3 17.5 11.6 5.8 Total Unit Power, kW 27.7 15.4 8.6 4.1 Efficiency, EER 10.08 13.58 16.23 16.91 Evaporator Data Fluid Entering Temperature, °F 54.0 51.5 49.0 46.5 Fluid Leaving Temperature, °F 44.0 44.0 44.0 44.0 Fluid Flow Rate, gpm 55.9 55.9 55.9 55.9 Fouling Factor, (hr-sqft-F)/BTU 0.0001 0.0001 0.0001 0.0001 Condenser Data Entering Air Temperature, °F 95.0 80.0 65.0 55.0 For some 75% operating points, the efficiency may be calculated at a condenser inlet air operating temperature as much as 0.8 degrees higher. Sound power measured in accordance with ANSI/AHRI 370-2001. Evaporator contains a glycol or other secondary coolants for freeze protection with a leaving chilled fluid temperature above 32°F and is certified in accordance with the AHRI Air-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI) when tested with water at Standard Rating Conditions. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Packaged Chiller Builder NACO 3.49j Page 9 of 10 Detailed Performance Summary For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Unit Parameters Tag Name:25T CH 4.23.15 Model Number:30RAP025 Condenser Type:Air Cooled Compressor Type:Scroll Chiller Nameplate Voltage:208/230-3-60 V-Ph-Hz Quantity:1 Manufacturing Source:Charlotte, NC USA Refrigerant:R410A Shipping Weight:1328 lb Operating Weight:1242 lb Unit Length:89 in Unit Width:41 in Unit Height:79 in 1 - Chiller Height Above Ground 2 - Horizontal Distance From Chiller to Receiver 3 - Receiver Height Above Ground (See Note 3) Accessories and Installed Options Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point Wind Baffle Security Grilles/Hail Guards Motormaster® V Low Ambient Kit. Operation down to -20° F (- 29° C). Low Sound Compressor Blankets Vibration Isolation Package Acoustic Information Table 1. A-Weighted Sound Power Levels (dB re 1 picowatt). See note #1. Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall 100% Load 37 58 68 78 83 84 83 77 67 89 75% Load 37 58 68 78 83 84 83 77 67 89 50% Load 37 58 68 78 83 84 82 77 67 88 25% Load 34 55 65 75 80 81 80 74 64 86 Table 2. A-Weighted Sound Pressure Levels (dB re 20 micropascals) calculated based upon user defined input for dimensions 1, 2 and 3 as shown in above diagram. See note #2 and #3. Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall 100% Load 10 31 40 50 55 56 55 49 40 61 75% Load 10 31 40 50 55 56 55 49 40 61 50% Load 10 30 40 50 55 56 55 49 40 61 25% Load 7 28 37 47 52 53 52 46 37 58 Notes: (1) Measurements performed in accordance with AHRI Standard 370 for air cooled Chillers. (2) Chiller is assumed to be a point source on a reflecting plane. (3) Without user defined input, the default dimensions used to construct Table 2 are as follows: 1 - Chiller Height Above Ground = 0.0 ft 2 - Horizontal Distance From Chiller to Receiver = 30.0 ft 3 - Receiver Height Above Ground = 3.0 ft Packaged Chiller Builder NACO 3.49j Page 10 of 10