HomeMy WebLinkAboutDRB150168_A1.0_1435769220.pdfRADON MITIGATION SYSTEM
PROVIDE DESIGN-BUILD ENGINEERING AND CONSTRUCTION OF A PASSIVE RADON MITIGATION SYSTEM FOR THE PROJECT TO WHICH AN INLINE FAN COULD BE ADDED LATER IF
REQUIRED PER THE FOLLOWING CRITERIA AND AS REQUIRED TO MAINTAIN RADON LEVELS AT THE MECHANICAL ROOM, LOWER LEVEL AND HOUSE BELOW EPA AND OTHER
GOVERNMENT STANDARDS. THE RADON MITIGATION SUBCONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH THE VAPOR BARRIER INSTALLATION SUB
SLAB INSULATION, PLUMBING/ROUGHIN AND THE ELECTRICIAN FOR AN ELECTRICAL JUNCTION BOXES AT THE LOCATIONS DETERMINED BY THE RADON MITIGATION
SUBCONTRACTOR FOR THE POTENTIAL FUTURE FANS.
AT A MINIMUM, THE FOLLOWING SYSTEMS/SERVICES WILL BE PROVIDED AS PART OF THE BASE BID BY THE RADON MITIGATION SUB CONTRACTOR.
- PROVIDE A CONTINUOUS 10 MIL VAPOR BARRIER UNDER ALL SLAB ON GRADE. MECHANICALLY FASTEN & SEAL TO WALLS, LAP & SEAL ALL JOINTS.
- SEALING OF THE LOWER LEVEL CONCRETE SLAB TO THE FOUNDATION WALLS
- SEALING OF ALL PLUMBING AND OTHER PENETRATIONS THROUGH VAPOR BARRIER, THE CONCRETE SLABS AND THROUGH THE BELOW GRADE PORTIONS OF THE FOUNDATION
WALL
- LOCATIONS & INSTALLATION OF PIPES, PORTS, AND OPENINGS IN THE SLAB FOR SLAB DEPRESSURIZATION SYSTEM.
- PROVIDE PASSIVE VENT PIPE SYSTEM WHICH RUNS FROM THE SLAB PENETRATION LOCATIONS(S) TO THE OUTSIDE IN ACCORDANCE WITH THE EPA STANDARDS. THE VENTS
SHALL BE RUN WITHIN THE INTERIOR OR EXTERIOR WALLS TO A LOCATION(S) HIGH ON THE ROOF. COORDINATE VENT LOCATIONS WITH ARCHITECT AND/OR OWNER
- PROVIDE POWER ADJACENT TO SLAB VENT PENETRATIONS FOR POTENTIAL FUTURE INLINE FAN LOCATION INCLUDING ALL REQUIRED ROUGH IN WIRING AND JUNCTION BOXES, IN
THE EVENT THAT A FAN IS REQUIRED TO BE INSTALLED
- PROVIDE PROVISIONS FOR A SYSTEM FAILURE INDICATOR, INCLUDING ALL REQUIRED ROUGH-IN WIRING, AND JUNCTION BOXES, IN THE EVENT THAT A FAN IS REQUIRED TO BE
INSTALLED.
- PERFORM RADON TESTING AFTER THE HOME/PASSIVE SYSTEM IS COMPLETE TO DETERMINE IF THE HOME PASSES OR IF AN ACTIVE SYSTEM IS REQUIRED IN ORDER TO MAINTAIN
RADON BELOW EPA AND OTHER GOVERNMENTAL STANDARDS.
- IF AN ACTIVE SYSTEM IS REQUIRED, PERFORM FOLLOW UP RADON TESTING AFTER THE SYSTEM IS COMPLETE TO DETERMINE IF RADON HAS BEEN MITIGATED
- PROVIDE AND INLINE FAN IF ACTIVE SYSTEM IS REQUIRED. PROVIDE OTHER EQUIPMENT AND SYSTEM AS REQUIRED TO PROVIDE A FUNCTIONAL RADON MITIGATION SYSTEM FOR
THE UNITS.
CONTRACTOR TO COORDINATE INSTALLATION OF THE 10 MIL VAPOR BARRIER UNDER THE SLAB INCUDING THE SEALING OF ALL JOINTS, ALL PLUMBING OR MECHANICAL OR
OTHER PENETRATIONS AND THE SEALING AND MECHANICAL FASTENING OF THE VAPOR BARRIER TO THE EXTERIOR CONCRETE FOUNDATION WALLS.
RE: OUTLINE SPEC FOR MORE DETAILS
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
4
1
A5.1
A
3.2
PROJECT DIRECTORY
1
2
3
4
A9.1
A6.1
1
A6.1
1
100
LIVING
1
A4.1
SIM.
SYMBOL LEGEND
ABBREVIATIONS
MATERIAL LEGEND
DRAWING LIST:
PROJECT INFORMATION
ARCHITECT
BERGLUND ARCHITECTS, LLC
P.O. Box 2378
210 Edwards Village Blvd
Suite A103
Edwards, CO 81632
Phone: (970) 926-4301
Fax: (970) 926-4364
hans@berglundarchitects.com
100
A
BUILDING
SECTION NO.
SECTION CUT
SHEET NO.
DETAIL NO.
DETAIL CUT
SHEET NO.
ROOM NUMBER
EXTERIOR ELEVATION
DOOR MARK
DETAIL CUT
REFERENCE GRID LINE
SPOT ELEVATION
DRAWING REVISION
INTERIOR ELEVATION
WINDOW MARK
Galvanized
Laminated Wood Beam
General Contractor
Hardware
Gypsum Wallboard
Grade
Gypsum
RW
RO
SEW
SECT
SAN
SHLV
Cpt Carpet
Ceramic
CER
SIM
SHT
W/
Reinforce (d)
REINF
FD Floor Drain
With (comb. form)
Required
Round Head Sheet Metal Screw
GA
FDN
FTG
Room
RM
RHSM
REQD
Gauge
Foundation
Footing
WD
W/O
Wood
Without
and Air Conditioning
Heating, Ventilating,
Lavatory
Manufacturer
Laminate
Inside Diameter
Miscellaneous
Mechanical
Not In Contract
Medicine Cabinet
Masonry Opening
Horizontal
On Center
Not to Scale
Oriented Strand Board
Opposite
Outside Diameter
Property
Plywood
Perforated (d)
Prefinished Sheet Metal
Penny (nails, etc.)
Refrigerator
Radius or Riser
Not Applicable
AAD
ADD
AGG
ADJ
AOR
BM
ARCH
ALT
BD
BS
BET
BRG
AFF
CL
BLDG
CAB
CLOS
CMU
CJ
CONC
COL
DP
DIA
DET
CONT
BO
DR
DN
DW
EL
EA
DRWG
DS
EQ
EJ
EXIST
EXT
FE CABT
FOC
FOS
FP
FL
FIN
DIM
GC
GALV
Glass
GLB
GR
GL
Head
HD
HDW
GWB
Highway
Height
HWY
HT
HVAC
GYP
Addendum
Attic Access Door
Aggregate
Adjacent
Area of Refuge
Alternate
Beam
Architectural
Board
Between
Both Sides
Bearing
Above Finished Floor
Interior
Joint
JT
INT
ID
MO
MFG
LAV
LAM
Maximum
Material
MAX
MC
MTL
Minimum
NIC
MISC
MIN
MECH
Cabinet
Building
Centerline
Closet
Concrete
Column
Construction Joint
Detail
Diameter
Damproofing
Continuous
Concrete Masonry Unit
HOR
Bottom Of
Opening
OPG
OC
NTS
d
OD
OSB
OPP
Plate
PL
PFSM
PLWD
PERF
Project
Product
PROD
PROP
PROJ
Drain
Dishwasher
Down
Elevation
Each
Drawing
Downspout
Equal
Existing
Exterior
Expansion Joint
Face Of Concrete
Face Of Stud
Fire Extinguisher Cabinet
Refer
REF
REFR
Floor
Fireproof R
Finish
NA
Dimension
Tongue and Groove
Toilet Paper Holder
Sound- Transmission Class
Vinyl Asbestos Tile
United States Gage
Unless Noted Otherwise
Uniform Building Code
SL
SQ
SPEC
STC
SM
SUB
STRUCT
STL
TV
TEL
SUSP
SUPPL
IE
THK
TEMP
TO
T&B
T&G
TPH
STD
Roof Window
Sewer
Sanitary
Section
Rough Opening
Sliding
Shelves
Similar
Square
Specification
Sheet Metal
Sheet
Steel
Substitute
Structure (al)
Television
Telephone
Suspend (ed)
Supplement (al)
That Is
Thick
Tempered
Top Of
Top and Bottom
Standard
UG
TYP
TS
USG
UBC
UNFIN
U.N.O.
VENT
VIF
VERT
VAR
VAT
WC
V
WT
WIN
WP
Typical
Underground
Tube Steel
Unfinished
Variable
Vertical
Ventilate
Verify In Field
Voltage
Water Closet
Weight
Window
Waterproof
T Tread
FINISHED WOOD
ROUGH FRAMING OR
ROUGH SAWN TRIM
WOOD BLOCKING
CONCRETE
STONE
TILE
GLAZING
FRAME WALL
CONCRETE MASONRY
PARTICLE BD. OR
GLU-LAM WOOD
WOOD FIBER BD.
RIGID INSULATION
CARPET
ACOUSTICAL CEILING
STEEL
PLYWOOD
SHEET METAL
BATT INSULATION
GYP. WALL BOARD/
STUCCO/ PLASTER
ALUMINUM OR
SECTION PLAN
SECTION PLAN
ROCK/
SOIL/ COMPACTED FILL
SAND
NON-COMPACTED FILL
STRUCTURAL
ENGINEER
LANDSCAPE
ARCHITECT
CLIENTS
Issue Date:
ELEV. 100'-0"
T.O. PWD.
SITE ELEV. = 116'-0"
Power Actuated Fastened
PAF
CODE INFORMATION
CONTRACTOR
VICINITY MAP
SURVEYOR
Gore Range Surveying, LLC
Contact: Sam Ecker
P.O. Box 15 Avon, CO 81620
Phone: (970) 479-8698
Fax: (970) 479-0055
MECHANICAL
ENGINEER
SOILS ENGINEER /
CIVIL ENGINEER
HP Geotech
Contact: Steve Pawlak
5020 County Road 154
Glenwood Springs, CO
81601
Phone: (970) 945-7988
Fax: (970) 945-8454
A. THE CONTRACT DOCUMENTS CONSIST OF ARCHITECTURAL AND STRUCTURAL DRAWINGS, THE AGREEMENT, THE GENERAL NOTES AND
THE SPECIFICATIONS. ANY WORK SHOWN IN ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY COVERED IN ALL. ANY
DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY.
B. CONTRACTOR WILL ASSUME RESPONSIBILITY OF ITEMS REQUIRING COORDINATION AND RESOLUTION DURING THE CONSTRUCTION
PROCESS
C. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES, AND SHALL BE PREFORMED TO THE HIGHEST
STANDARDS OF CRAFTSMANSHIP BY JOURNEYMAN OF THE APPROPRIATE TRADES.
D. THESE DOCUMENTS ARE INTENDED TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE ALL
WORK DESCRIBED HEREIN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY
CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTION ACCORDING TO THE INTENTIONS OF THESE DOCUMENTS. IT IS THE
RESPONSIBILITY OF THE ARCHITECT TO PROVIDE DETAILS AND/OR DIRECTIONS REGARDING DESIGN INTENT WHERE IT IS ALTERED
BY EXISTING CONDITIONS OR WHERE NEGLECTED IN THE DOCUMENTS.
E. ANY MATERIALS PROPOSED FOR SUBSTITUTION OF THOSE SPECIFIED OR CALLED OUT BY TRADE NAME IN THESE DOCUMENTS SHALL
BE PRESENTED TO THE ARCHITECT FOR REVIEW. THE CONTRACTOR SHALL SUBMIT SAMPLES WHEN REQUIRED BY THE ARCHITECT.
AND ALL SUCH SAMPLES SHALL BE REVIEWED BY THE ARCHITECT BEFORE THE WORK IS PERFORMED. WORK MUST CONFORM TO
THE REVIEWED SAMPLES. ANY WORK WHICH DOES NOT CONFORM SHALL BE REMOVED AND REPLACED WITH WORK WHICH
CONFORMS AT THE CONTRACTOR'S EXPENSE. SUBCONTRACTORS SHALL SUBMIT REQUESTS AND SAMPLES FOR REVIEW THROUGH
THE GENERAL CONTRACTOR WHEN WORK IS LET THROUGH HIM OR HER. REQUIRED VERIFICATIONS AND SUBMITTALS TO BE MADE IN
ADEQUATE TIME AS TO NOT DELAY PROGRESS.
F. SHOP DRAWINGS MUST BE THOROUGHLY REVIEWED BY CONTRACTOR PRIOR TO SUBMITTING TO ARCHITECT TO MAKE SURE THEY ARE
ACCURATE AND MEET DESIGN INTENT. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR HIS OR HER REVIEW WHERE
CALLED FOR ANYWHERE IN THESE DOCUMENTS. REVIEW SHALL BE MADE BY THE ARCHITECT BEFORE WORK IS BEGUN, AND WORK
SHALL CONFORM TO THE REVIEWED SHOP DRAWINGS, SUBJECT TO REPLACEMENT AS REQUIRED IN PARAGRAPH E ABOVE.
ARCHITECT WILL TRY TO IDENTIFY ANY DISCREPENCIES IN SHOP DRAWINGS, BUT CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR
SHOP DRAWING ACCURACY.
G. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR WHEN THERE IS NEED OF INSPECTION AS REQUIRED BY THE 2012
INTERNATIONAL RESIDENTIAL CODE OR ANY LOCAL CODE OR ORDINANCE.
H. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, FOR
COMPLIANCE WITH FEDERAL AND STATE O.S.H.A. REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS DELIVERED
COMPLETED TO THE OWNER.
I. ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALED DIMENSIONS. DIMENSIONS NOTED WITH "N.T.S." DENOTES NOT TO SCALE.
J. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS, CEILINGS, AND WALLS WITH ALL ARCHITECTURAL,
STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS.
K. CONTRACTOR TO COORDINATE NEW CONSTRUCTION W/EXISTING CONDITIONS AND NOTIFY ARCHITECT AND STRUCTURAL ENGINEER
ABOUT DISCREPENCIES OF DRAWINGS OF EXISTING HOUSE AND ASSUMPTIONS.
GENERAL NOTES
KRM Consultants Inc.
Contact: Tim Hennum
P.O. Box 4572
Vail, CO 81658
Office: (970) 949-9391
Fax: (970 949-0839
krm@krmconsultants.com
Ceres+ Landscape
Architecture
Contact: Scott Sones
P.O. Box 2134
Eagle, CO 81631
Phone: (970) 949-3286
Fax: (970) 262-2162
studio@ceres-plus.com
Rader Engineering
Contact: Drew Rader
40690 Hwy. 6
Suite E-1
Avon, CO 81620
Phone: (970) 845-7910
Fax: (970 845-7522
drader@raderengineering.com
CIMEX INVEST, INC.
5150 Tamiami Trial N Ste 503
Naples, FL 34103-2822
Shaeffer Hyde Construction
Contact: David Hyde
P.O. Box 373
Vail, CO 81658
Phone: (970) 845-5656
davidh@shaefferhyde.com
LIGHTING
DESIGNER
Lacroux Streeb Lighting
Design, Inc.
Contact:
Aspen, CO 81612
Phone: (970) 927-5133
Fax:
1/4" = 1'-0"
6/29/2015 12:24:39 PM
A1.0
COVER
SHEET
AG
HB
165 FOREST RD VAIL, CO
06/29/2015
VAIL VILLAGE FILING 1, BLOCK 7, LOT 29
REVISED DRB SET
165 FOREST RD VAIL, CO
VAIL VILLAGE FILING 1, BLOCK 7, LOT 29
06/29/2015
REVISED DRB SET
A1.0 COVER SHEET
SURVEY
LANDSCAPE DRAWINGS
L1- SITE PLAN
L1.1- SITE PLAN
L-2 PLANTING PLAN
ARCHITECTURAL DRAWINGS
A2.1 SITE PLAN
A2.2 DEMO PLAN
A2.3 SLOPE ANALYSIS
A2.4 PRE-EXISITING GRADE
A2.5 AREA CALCS
A2.6 AREA CALCS
A2.7 LOT DISTURBANCE CALC
A2.8 LANDSCAPE AREA CALCS
A3.1 LEVEL 1- FAMILY, SPA, HOBBY AND EXERCISE FLOOR PLAN
A3.2 LEVEL 2- GARAGE AND BEDROOMS FLOOR PLAN
A3.3 LEVEL 3- MAIN LEVEL FLOOR PLAN
A3.4 LEVEL 4- UPPER LEVEL FLOOR PLAN
A3.5 ROOF PLAN
A4.1 ELEVATIONS
A4.2 ELEVATIONS
A4.3 ELEVATIONS
A4.4 ELEVATIONS
A4.5 3D VIEWS
A4.6 3D VIEWS
A4.7 3D VIEWS
A5.4 SECTIONS
A5.8 SECTIONS
A5.9 SECTIONS
A6.1 DETAILS
CODE: 2012 IRC, 2012 IECC OCCUPANCY TYPE: SINGLE FAMILY HOME
ENERGY CONSERVATION: THE BUILDING COMPLIES WITH THE ENERGY CONSERVATION REQUIREMENT FROM CHAPTER 4 OF THE 2012
INTERNATIONAL ENERGY CODE PER ZONE 6B ADOPTED BY THE TOWN OF VAIL, AND AS DEMONSTRATED BY REScheck SOFTWARE, AS
FOLLOWS:
The following is a summary for the climate zone 6B of Table 402.1.1 requirements of the IEC and as adopted by The Town of Vail, and an outline of the proposed
R values of the assemblies of the building which are defined in the Construction Document Drawings and Specifications:
Maximum Glazing U-Factor of .30 for new single family dwelling units per Town of Vail amendments, this can be a weighted average.
*Note - Upon approval from the Architect the Contractor may use alternate insulation materials to achieve equal R-values
Ceilings - Requirement of R-49 which is reduced to R-38 per N1102.2.1 since the construction techniques provide a full R-38 insulation value over the wall top
plate. The design provides a full R-38 insulation value over the wall top plate as follows:
1. 11 7/8" LVL Roof Assembly - Provides R-72.7 min. per the 5/8" plywood over R-25 min. 8"-5 1/2" tapered rigid foam panels over 5/8" plywood over 11 7/8" cavity
LVL filled w/ R12.2 per 2" of 2# closed cell spray foam insulation (R6.6 per inch) plus R35.5 per 9 7/8" (9.875") blown in R-42.75 cellulose insulation with GWB
ceiling with a full R-38 assembly provided over top plate
2. 12K1 Barjoist Roof Assembly- Provides R-67.75 per the 5/8" plywood over R-25 8"-5 1/2" tapered rigid foam panels over 5/8" plywood over 12" bar joists.
Cavity filled with blown in R-42.75 cellulose insulation with GWB ceiling with a full R-38 assembly provided over top plate.
3. Roof Deck
Walls - Requires R-20: Providing R-29.8 per the sum of the provided R values of the typical 2x6 wood framing wall assembly with exterior wall finish (stucco, metal
panel, copper panels, or 6" stone veneer), over 2 5/8" insulation panel (5/8" exterior sheathing, R-10 2" rigid foam insulation panels), 1/2" structural exterior
sheathing, R-12.2 2" of 2# closed cell spray foam (R6.6 per inch) insulation plus R12.6 3 1/2" blown in cellulose insulation (R-3.6 per inch), and 5/8" drywall
exceeds the requirement.
Basement Walls - Requires R-10 of continuous insulation or R-13 cavity insulation : Providing R-29.9 per the sum of the provided R values of the R-20 4" rigid
extruded foam insulation over the concrete wall with 2x wood furring set 1/2" off concrete with 1 1/2" of 2# closed cell spray foam insulation with R-9.9 (R-6.6 per
inch) and 5/8" drywall exceeds the requirement. Note: R-20 exterior insulation is provided at all below grade conditions.
Basement Slab - Requires R-15 for 4' (since the slab is heated)- Provide R40 per the R-20 exterior rigid extruded insulation from T.O. footing to grade, and the R-
20 4" rigid extruded insulation continuous under the topping slab
ADDITIONAL REQUIREMENTS PER TOWN OF VAIL CODE AMENDMENTS:
ROOF COVERING: Meets Section 1505.6 of the Town of Vail Code- The standing seam metal roofing will be installed to meet the required Class A roof or Class
A roof assembly.
FIRE SPRINKLER SYSTEM: Building is to be equipped throughout with an automatic sprinkler system installed in accordance with NFPA 13 and the Town of Vail.
A monitored fire alarm system will also be provided.
PLUMBING: See water service documents from mechanical engineer. See Architectural Drawings for fixture locations.
MECHANICAL: See mechanical documents from mechanical engineer.
ELECTRICAL: See load calculations from mechanical engineer for service and electric panel sizing
BLOWER DOOR TEST: A blower door test will be provided.
165 Forest Road, Vail Village, Filing 1, Block 7, Lot 29
Zone District: Two-Family Primary/Secondary Residential ( PS )
Lot is .4315 acres, equal to 18,796 SF
Allowable GRFA
.46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.46 equals 4,600 SF
.38 SF per 1 SF of site area > 10,000 SF of site area 5,000 x 0.38 equals 1,900 SF
.13 SF per 1 SF of site area > 10,000 SF of site area 1,024 x 0.13 equals 493 SF
___________________________________________________________________________________
Total Allowed Gross Residential Floor Area (GRFA) for entire lot 6,993 SF
Site Coverage
Allowable site coverage on the lot: 20% 3,759 SF
Proposed Site Coverage 3,746 SF
Proposed Site Coverage for Roofs beyond 4' - SF
_____________________________________________________________
Total Remaining Site Coverage 52 SF
Square Footage Summary
Habitable SF GRFA SF
Level 1 - Lower Level 3,124 SF 1,280.8 SF *1
Level 2 - Garage and Bedrooms 1,520 SF 1,520 SF
Garage area over 1200 SF - 112 SF
Level 3 - Main Level 3,010 SF 3,010 SF
Level 4 - Upper Level 1,069 SF 1,069 SF
____________________________________________________________________
Total 8,723 SF 6,991.8 SF
Total Habitable (not including garage overage) 8,723 SF
Garage Total Square Footage 1,312 SF
Total GRFA 6,992 SF
Allowable 6,993 SF
Remaining GRFA 1 SF
*1 41% OF THE LOWER LEVEL WALL IS ABOVE EXISTING OR FINISHED GRADE WHICHEVER WAS MORE RESTRICTIVE,
THEREFORE 41% OF THE LOWER LEVEL SF IS COUNTED AS GRFA (LOWER LEVEL HABITABLE 3,124 SF * .41 = 1,283.3 SF)
Setbacks
20' from front
15' from sides
15' from rear
Patio can extend to 1/2 the distance of the setback
Decks can encroach set back 5'
Roof or architectural projections can encroach 4'
Height
Flat or mansard roofs not to exceed 30'
Sloping roof not to exceed 33'
Garage
Allow 1,200 sq. ft. per lot. 1,316 SF is provided.
Parking Required per Chapter 10
If dwelling is more than 5,500 GRFA 5 spaces are required. (4) covered 9' x 18' in garage and (2) exterior covered 9' x 19' parking spaces are
provided.
No.
Revision
Description Revision Date
DRB
APPROVED
6/3/2015 12:00:00
AM