Loading...
HomeMy WebLinkAboutDRB150168_A5.4_1435769220.pdfLEVEL 1- GUEST SUITE AND EXERCISE 18' - 10 5/8" LEVEL 4- UPPER LEVEL AND ROOF DECK 53' - 0" LEVEL 2- GARAGE AND BEDROOMS 33' - 0" BASEMENT- SPA AND HOBBY LEVEL 7' - 6" LEVEL 3- MAIN LEVEL FLOOR PLAN 43' - 0" ROOF PLAN 65' - 0" 1 A5.11 1 A5.7 1 A5.8 LEVEL 1A- EXERCISE AND BEDROOM 13' - 10 5/8" LEVEL 2A- BEDROOMS 26' - 7 1/2" LEVEL 3A- MAIN LEVEL 39' - 9" LEVEL 4A- ROOF DECK 54' - 3" 1 A5.13 1 A5.12 1 2 3 4 6 7 8 5 1 A5.9 1 A5.10 1 A5.5 1 A5.6 1 A5.14 054 401 034 307 055 401 029 304 075 304 031 305 030 305 033 306 032 306 036 308 037 309 038 310 017 209 017 209 077 308 003 102 012 203 020 300 020 300 021 300 021 300 021 300 052 400 052 400 042 312 073 312 053 400 003 102 000 100 000 100 000 100 043 312 041 312 001 200 006 202 027 303 026 303 062 404 060 404 061 404 063 404 012 205 022 236 022 237 022 238 1' - 6" Q 1' - 6" 23' - 6 1/2" 30' - 5" 24' - 1 7/8" 1' - 8 5/8" 18' - 4" 14' - 6" 10' - 0" 6' - 4 5/8" 5' - 0" 7' - 8 7/8" 6' - 4 1/2" 6' - 9" 3' - 3" 10' - 0" 1' - 3" 10' - 9" 001 200 002 100 002 100 002 100 019 101 019 101 27' - 0 1/2" DSB10 DSB10 DSB8 DSB8 079 402 CONSTRUCTION ASSEMBLY LEGEND: SEE DETAILS, STRUCTURAL DRAWINGS, AND SPEC FOR MORE DETAILED INFORMATION ROOF ASSEMBLIES RW10S: STANDING SEAM ROOF, W.P. MEMBRANE, 5/8” PLYWOOD, 4” RIGID FOAM INSULATION, 5/8” ROOF SHEATHING, 9 1/2” LVL FRAMING @ 2:12 SLOPE, 5/8” DRYWALL RW8E: WHITE EPDM ROOF, TAPERED INSULATION PANEL@ ¼”: 1’-0” SLOPE, 5/8” ROOF SHEATHING, 7 ¼” LVL FRAMING, 5/8” DRYWALL RW12E: WHITE EPDM ROOF, 5/8” PLYWOOD SHEATHING 11 7/8” LVL FRAMING RIPPED TOP @ ¼”:1’-0”, 5/8” DRYWALL - ELEVATOR ROOF RW12E+: WHITE EPDM ROOF, TAPERED INSULATION PANEL 4” MIN, 5/8” ROOF SHEATHING, 11 7/8” TJI FRAMING, 5/8” DRYWALL – MASTER BEDROOM RSB12EP: PEDESTAL, EPDM ROOF, TAPERED NAILBASE INSULATION PANEL 4” MIN @ ¼”:1’-0” SLOPE, 1 ½” METAL DECKING, 12K1 BAR JOISTS, ½” RESILIENT CHANNEL, ¾” T&G DECKING AT EXTERIOR – MASTER BATHROOM DECK ASSEMBLIES DW10: 4 ¼” FINISH ASSEMBLY (5/8” PORCELAIN TILE, ¼” – 3/8” SETTING BED, 2 ½” TOPPING SLAB W/ HEAT TUBE, ¾” DRAINAGE MEDIUM AND W.P. MEMBRANE), ¾” PLYWOOD SHEATHING, 2X10 JOIST WITH TOP RIPPED TO SLOPE, ¾” T&G DECKING AT SOFFIT. DW14: 4 ¼” FINISH ASSEMBLY (5/8” PORCELAIN TILE, ¼” – 3/8” SETTING BED, 2 ½” TOPPING SLAB W/ HEAT TUBE, ¾” DRAINAGE MEDIUM AND W.P. MEMBRANE), ¾” PLYWOOD SHEATHING, 14” LVL JOIST WITH TOP RIPPED TO SLOPE, ¾” T&G SOFFIT DECKING AT EXTERIOR AND 5/8” DRYWALL AT INTERIOR. DSB8: 3 ¾” FINISH ASSEMBLY (5/8” PORCELAIN TILE, ¼” – 3/8” SETTING BED, 2” TOPPING SLAB W/ HEAT TUBE, ½” DRAINAGE MEDIUM AND W.P. MEMBRANE), 4” - 2” MIN. STRUCTURAL SLAB (9/16” DECKING, WELDED WIRE MESH), 8K1 BAR JOISTS, ½” RESILIENT CHANNEL, ¾” T&G DECKING AT EXTERIOR DSB10: 3 ¾” FINISH ASSEMBLY (5/8” PORCELAIN TILE, ¼” – 3/8” SETTING BED, 2” TOPPING SLAB W/ HEAT TUBE, ½” DRAINAGE MEDIUM AND W.P. MEMBRANE), 4” - 2” MIN. STRUCTURAL SLAB (9/16” DECKING, WELDED WIRE MESH), 10K1 BAR JOISTS, ½” RESILIENT CHANNEL, ¾” T&G DECKING AT EXTERIOR FLOOR ASSEMBLIES FW14: 4 ¼” FINISHED ASSEMBLY (5/8” PORCELAIN TILE, ¼” – 3/8” SETTING BED, 3 ¼” TOPPING SLAB W/ HEAT TUBE), ¾” PLYWOOD SHEATHING, 14” LVL JOIST, ¾” T&G DECKING AT EXTERIOR AND 5/8” DRYWALL AT INTERIOR. FSW8: 1 ¼” FINISHED ASSEMBLY (5/8” PORCELAIN TILE, ¼ – 3/8” SETTING BED, ¼” ANTI-FRACTURE), 2 1/2” STRUCTURAL SLAB (9/16” DECKING, WELDED WIRE MESH AND HEAT TUBES), W8X21 JOIST, 2 5/8” NAIL BASE PANEL (5/8” PLYWOOD, 2” INSULATION), ¾” T&G WOOD DECKING FSB12: 1 ¼” FINISHED ASSEMBLY (5/8” PORCELAIN TILE, ¼ – 3/8” SETTING BED, ¼” ANTI-FRACTURE), 2 1/2” STRUCTURAL SLAB (9/16” DECKING, WELDED WIRE MESH AND HEAT TUBES), 12K1 BAR JOISTS, ½” RESILIENT CHANNEL, 5/8” DRYWALL FSB14: 1 ¼” FINISHED ASSEMBLY (5/8” PORCELAIN TILE, ¼ – 3/8” SETTING BED, ¼” ANTI-FRACTURE), 2 1/2” STRUCTURAL SLAB (9/16” DECKING, WELDED WIRE MESH AND HEAT TUBES), 14K1 BAR JOISTS, ½” RESILIENT CHANNEL, 5/8” DRYWALL GARAGE AND AUTOCOURT ASSEMBLIES GS14: 3 7/8” FINISH ASSEMBLY (1/8” EPOXY FINISH, 3” TOPPING SLAB W/ HEAT TUBE, ¾” DRAINAGE MEDIUM AND W.P. MEMBRANE), 6”-4” MIN STRUCTURAL SLAB, 1 ½” METAL DECKING, 14” BAR JOISTS, ½” RESILIENT CHANNEL, ~1” FURRING, 5/8” DRYWALL ASW8: 4 ¼” FINISH ASSEMBLY (5/8” PORCELAIN TILE, ¼” – 3/8” SETTING BED, 2 ½” TOPPING SLAB W/ HEAT TUBE, ¾” DRAINAGE MEDIUM AND W.P. MEMBRANE), 6” - 4” MIN. STRUCTURAL SLAB, 1 ½” METAL DECKING, W8X21 STEEL BEAM JOIST, ½” RESILIENT CHANNEL, 5/8” DRYWALL (THIS ASSEMBLY IS CURRENTLY 3” THICKER THAN PLANNED, NEED TO DISCUSS TOMORROW) ASB14: 4 ¾” FINISH ASSEMBLY (2 ½” PAVER, 1 ½” SAND W/ HEAT TUBE, ¾” DRAINAGE MEDIUM AND W.P. MEMBRANE), 6”-4” MIN STRUCTURAL SLAB, 1 ½” METAL DECKING, 14” BAR JOISTS, ½” RESILIENT CHANNEL, 5/8” DRYWALL OR ¾” T&G DECKING AT EXTERIOR Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 6/17/2015 8:58:58 PM A5.4 BUILDING SECTIONS AG HB 165 FOREST RD VAIL, CO 06/17/2015 VAIL VILLAGE FILING 1, BLOCK 7, LOT 29 REVISED FINAL DRB SET No. Revision Date Revision Description 1/4" = 1'-0" 1 Section 4 DRB APPROVED 6/3/2015 12:00:00 AM