Loading...
HomeMy WebLinkAboutDRB150177_A4.6_1432325400.pdf1. MAIN LEVEL 8397' - 7" 0. LOWER LEVEL 8387' - 6" 6 A4.6 8396' - 11" 8387' - 2" 8397' - 2" 5" 8385' - 0" 8391' - 6" 8387' - 4" HOT TUB GRAVEL LEDGE 8397' - 2 3/8" 8397' - 6" 10X10 DECK POST 6 3/4" X 18" PERIMETER BEAM COMPOSITE DECKING PALATTES OVER SLOPING FURRING OVER PLYWD SHEATHING OVER 7 1/4" LVL W/ 1X6 T&G SOFFIT METAL GUARDRAIL 3 1/8" X 18" PERIMETER BEAM 1. MAIN LEVEL 8397' - 7" 0. LOWER LEVEL 8387' - 6" 1.1 GARAGE / ENTRY 8401' - 2 1/2" EAST MAIN LEVEL 8400' - 0 1/2" 5' - 0" 7 9/16" 7 9/16" 1 1/8" FTG. SHELF HOT TUB STAIR WALL BUILT FROM PREVIOUSLY USED CONCRETE BLOCK 10X10 DECK POST 6 3/4" X 18" PERMITER BEAM COMPOSITE DECKING PALATTES OVER SLOPING FURRING OVER PLYWD SHEATHING OVER 7 1/4" LVL W/ 1X6 T&G SOFFIT METAL GUARDRAIL CRAWLSPACE STRUCTURAL TIES 1. MAIN LEVEL 8397' - 7" 2. UPPER LEVEL 8410' - 6 1/2" PLATE HT. 8418' - 7 1/2" 0. LOWER LEVEL 8387' - 6" EAST MAIN LEVEL 8400' - 0 1/2" GA FILE NO. WP 3812 GENERIC 2 HOUR FIRE RATING W/ +59 STC SOUND RATING: BASE LAYER: 1/2" type X gypsum wallboard applied at right angles to 2x6 (substitute) wood studs 24" o.c.with 6d coated nails, 1 7/8" long 0.086" shank, 1/4" heads, 16" o.c. FACE LAYER: 1/2" type x gypsum wallboard applied at right angles to studs over base layer and to top and bottom plates with 8d coated nails, 2 3/8" long, 0.099" shank, 9/32" heads, 8" o.c. Joints in inner layer need not be taped. INNER LAYER: 5/8" type x gypsum wallboard applied parallel with 6d coated nails, 1 7/8" long, 0.0915" shank, 1/4" heads, 8" o.c. Joints in inner layer need not be taped. SECOND WALL: duplicate of first wall and seperated by 1 3/4" (substitute from 1") space. walls independently loaded. SOUND TESTED: with 3 1/2 " glass fiber insulation, 0.75 pcf, friction fit in stud spaces (substitute w/ 5 1/2" BIBS). EXTERIOR 5/8" GWB APPLIED TO THE UNDER SIDE OF ROOF SOFFIT AND COVERED WITH 1x6 WOOD T&G SOFFIT MATERIAL 5/8" GWB APPLIED TO THE UNDER SIDE OF ROOF SHEATHING FOR A DISTANCE OF 4'-0" FROM PARTY WALL WATERPROOF MEMBRANE FROM ROOF TO RUN UP WALL 24" MIN. STEP FLASHING AND COUNTER FLASHING. SIDING TO BE KEPT OFF ROOF SURFACE BY 4" 5 1/2" 1 1/2" 1 1/2" 5 1/2" 1' - 2" LOT-SPLIT LINE (CENTERLINE) LOT SPLIT LINE NOTES: NO PARALLEL OPENINGS WITHIN 36" OF LOT LINE. KEEP BOTH SIDES STRUCTURALLY INDEPENDENT OF EACH OTHER FROM FOUNDATION TO ROOF. NO ENCROACHMENTS WITHOUT PROPER FIRE SEPARATION AND LEGAL OWNER AGREEMENTS. 1 1. MAIN LEVEL 8397' - 7" 2. UPPER LEVEL 8410' - 6 1/2" PLATE HT. 8418' - 7 1/2" 0. LOWER LEVEL 8387' - 6" 1.1 GARAGE / ENTRY 8401' - 2 1/2" EAST MAIN LEVEL 8400' - 0 1/2" INSTALL 90 DEGREE FITTING AND 4 FT. TAIL OF 4 IN. DRAIN TILE EMBEDDED IN FREE DRAINING GRAVEL. NOTE: ALL CONTROL JOINTS, ISOLOATION JOINTS, CONSTRUCTION JOINTS AND ANY OTHER JOINTS IN THE CONCRETED SLABS, OR BETWEEN SLABS AND FOUNDATION WALLS SHALL BE SEALED WITH A CAULK OR SEALEANT. GAPS AND JOINTS SHALL BE CLEARED OF LOOSE MATERIAL AND FILLED WITH POLYUERETHANE CAULK OR OTHER ELASTOMERIC SEALANT APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. PIPING TO RUN HORIZONTALLY WITHIN THE GRAVEL OF EXISTING CRAWLSPACE. ROUTE 4" ABS, PVC, OR EQUIVILENT GAS- TIGHT, SUBSLAB PASSIVE SLAB DEPRESSURIZATION VENT FROM BASEMENT TO ROOF THROUGH INTERIOR CHASE. ALLOW FOR THE FUTURE INSTALLATION OF AN IN-LINE FAN. PROVIDE A 110 VOLT RECEPTACLE AT THE FAN LOCATION . PLACE LABELS ON VENT AT EACH LEVEL: "RADON MITIGATION SYSTEM". EXTEND VENT PIPE 12" ABOVE ROOF. F A N MECH E408 EXISTING 2 CAR GARAGE E300 1. MAIN LEVEL 8397' - 7" 0. LOWER LEVEL 8387' - 6" SEE WALL SECTION - EAST RADON FOR NOTES F A N AIR INTAKE AND EXHAUST PIPES FROM FURNACE METAL RAILING PAINTED TO MATCH DARK BRONZE PLATE BOLTED TO WOOD POST 3' - 1" 2 1/2" 4" 1 1/2" 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 5/18/2015 12:05:29 PM A4.6 WALL & DECK SECTIONS 1406 Katsos Ranch Renovation PERMIT SET 5-6-15 5-18-15 Katsos Ranch, LLC 3235 Katsos Ranch Road, Vail CO No. Description Date 1 REV1 - Vail Comments 5-18-15 3/8" = 1'-0" 1 WALL SECTION - WEST - DECK 1 3/8" = 1'-0" 2 WALL SECTION - EAST DECK 1 1/2" = 1'-0" 3 WALL SECTION - PARTY WALL 1/4" = 1'-0" 4 WALL SECTION - EAST RADON 1/4" = 1'-0" 5 WALL SECTION - WEST RADON 1 SEE ELEVATOR SECTION FOR RADON 2 3/4" = 1'-0" 6 RAILING DETAIL DRB APPROVED 5/22/2015 12:00:00 AM