HomeMy WebLinkAboutDRB150177_A4.6_1432325400.pdf1. MAIN LEVEL
8397' - 7"
0. LOWER LEVEL
8387' - 6"
6
A4.6
8396' - 11"
8387' - 2"
8397' - 2"
5"
8385' - 0"
8391' - 6"
8387' - 4"
HOT TUB
GRAVEL LEDGE
8397' - 2 3/8"
8397' - 6"
10X10 DECK POST
6 3/4" X 18" PERIMETER BEAM
COMPOSITE DECKING PALATTES
OVER SLOPING FURRING OVER
PLYWD SHEATHING OVER 7 1/4"
LVL W/ 1X6 T&G SOFFIT
METAL GUARDRAIL
3 1/8" X 18" PERIMETER BEAM
1. MAIN LEVEL
8397' - 7"
0. LOWER LEVEL
8387' - 6"
1.1 GARAGE /
ENTRY
8401' - 2 1/2"
EAST MAIN LEVEL
8400' - 0 1/2"
5' - 0"
7 9/16"
7 9/16"
1 1/8"
FTG. SHELF
HOT TUB
STAIR WALL BUILT FROM
PREVIOUSLY USED
CONCRETE BLOCK
10X10 DECK POST
6 3/4" X 18" PERMITER BEAM
COMPOSITE DECKING PALATTES
OVER SLOPING FURRING OVER
PLYWD SHEATHING OVER 7 1/4"
LVL W/ 1X6 T&G SOFFIT
METAL GUARDRAIL
CRAWLSPACE
STRUCTURAL TIES
1. MAIN LEVEL
8397' - 7"
2. UPPER LEVEL
8410' - 6 1/2"
PLATE HT.
8418' - 7 1/2"
0. LOWER LEVEL
8387' - 6"
EAST MAIN LEVEL
8400' - 0 1/2"
GA FILE NO. WP 3812 GENERIC 2 HOUR FIRE RATING
W/ +59 STC SOUND RATING:
BASE LAYER: 1/2" type X gypsum wallboard applied at right
angles to 2x6 (substitute) wood studs 24" o.c.with 6d coated
nails, 1 7/8" long 0.086" shank, 1/4" heads, 16" o.c.
FACE LAYER: 1/2" type x gypsum wallboard applied at right
angles to studs over base layer and to top and bottom plates
with 8d coated nails, 2 3/8" long, 0.099" shank, 9/32" heads,
8" o.c. Joints in inner layer need not be taped.
INNER LAYER: 5/8" type x gypsum wallboard applied
parallel with 6d coated nails, 1 7/8" long, 0.0915" shank, 1/4"
heads, 8" o.c. Joints in inner layer need not be taped.
SECOND WALL: duplicate of first wall and seperated by
1 3/4" (substitute from 1") space. walls independently loaded.
SOUND TESTED: with 3 1/2 " glass fiber insulation, 0.75 pcf,
friction fit in stud spaces (substitute w/ 5 1/2" BIBS).
EXTERIOR 5/8" GWB
APPLIED TO THE UNDER
SIDE OF ROOF SOFFIT AND
COVERED WITH 1x6 WOOD
T&G SOFFIT MATERIAL
5/8" GWB APPLIED TO THE
UNDER SIDE OF ROOF
SHEATHING FOR A DISTANCE OF
4'-0" FROM PARTY WALL
WATERPROOF MEMBRANE FROM ROOF
TO RUN UP WALL 24" MIN.
STEP FLASHING AND COUNTER FLASHING.
SIDING TO BE KEPT OFF ROOF SURFACE BY 4"
5 1/2"
1 1/2"
1 1/2"
5 1/2"
1' - 2"
LOT-SPLIT LINE
(CENTERLINE)
LOT SPLIT LINE NOTES:
NO PARALLEL OPENINGS WITHIN 36" OF LOT
LINE.
KEEP BOTH SIDES STRUCTURALLY
INDEPENDENT OF EACH OTHER FROM
FOUNDATION TO ROOF.
NO ENCROACHMENTS WITHOUT PROPER FIRE
SEPARATION AND LEGAL OWNER AGREEMENTS.
1
1. MAIN LEVEL
8397' - 7"
2. UPPER LEVEL
8410' - 6 1/2"
PLATE HT.
8418' - 7 1/2"
0. LOWER LEVEL
8387' - 6"
1.1 GARAGE /
ENTRY
8401' - 2 1/2"
EAST MAIN LEVEL
8400' - 0 1/2"
INSTALL 90 DEGREE FITTING AND 4 FT. TAIL
OF 4 IN. DRAIN TILE EMBEDDED IN FREE
DRAINING GRAVEL.
NOTE: ALL CONTROL JOINTS, ISOLOATION
JOINTS, CONSTRUCTION JOINTS AND ANY
OTHER JOINTS IN THE CONCRETED SLABS, OR
BETWEEN SLABS AND FOUNDATION WALLS
SHALL BE SEALED WITH A CAULK OR SEALEANT.
GAPS AND JOINTS SHALL BE CLEARED OF
LOOSE MATERIAL AND FILLED WITH
POLYUERETHANE CAULK OR OTHER
ELASTOMERIC SEALANT APPLIED IN
ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS.
PIPING TO RUN HORIZONTALLY WITHIN
THE GRAVEL OF EXISTING CRAWLSPACE.
ROUTE 4" ABS, PVC, OR EQUIVILENT GAS-
TIGHT, SUBSLAB PASSIVE SLAB
DEPRESSURIZATION VENT FROM BASEMENT
TO ROOF THROUGH INTERIOR CHASE.
ALLOW FOR THE FUTURE INSTALLATION OF AN
IN-LINE FAN.
PROVIDE A 110 VOLT RECEPTACLE AT THE FAN
LOCATION .
PLACE LABELS ON VENT AT EACH LEVEL:
"RADON MITIGATION SYSTEM".
EXTEND VENT PIPE 12" ABOVE ROOF.
F
A
N
MECH
E408
EXISTING 2 CAR
GARAGE
E300
1. MAIN LEVEL
8397' - 7"
0. LOWER LEVEL
8387' - 6"
SEE WALL SECTION -
EAST RADON
FOR NOTES
F
A
N
AIR INTAKE AND EXHAUST
PIPES FROM FURNACE
METAL RAILING
PAINTED TO MATCH
DARK BRONZE
PLATE BOLTED
TO WOOD POST 3' - 1"
2 1/2" 4" 1 1/2"
970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631
www.martinmanleyarchitects.com
Project number Date REVISIONS
5/18/2015 12:05:29 PM
A4.6 WALL & DECK SECTIONS 1406 Katsos Ranch Renovation
PERMIT SET 5-6-15 5-18-15 Katsos Ranch, LLC 3235 Katsos Ranch Road, Vail CO
No. Description Date
1 REV1 - Vail Comments
5-18-15
3/8" = 1'-0" 1
WALL SECTION - WEST - DECK 1
3/8" = 1'-0" 2
WALL SECTION - EAST DECK 1
1/2" = 1'-0"
3
WALL SECTION - PARTY WALL
1/4" = 1'-0" 4
WALL SECTION - EAST RADON
1/4" = 1'-0" 5
WALL SECTION - WEST RADON 1
SEE ELEVATOR SECTION FOR RADON 2
3/4" = 1'-0" 6
RAILING DETAIL
DRB
APPROVED
5/22/2015
12:00:00 AM