Loading...
HomeMy WebLinkAboutDRB150199_A2.2_1434149580.pdfD W 24 28 25 22 18 28 23 23 35.9 35.9 36.25 4'-0" CONCRETE PAN WITH 2" FLOW CHANNEL 35.7 33.4 33.04'-0" CONCRETE PAN WITH 2" FLOW CHANNEL 31.8 31.8 32.2 32.0 31.0 29 35.5 3432 36 38 35.8 35.8 35.9 32 31.9 FINISH 32.5 FINISH 31.7 40 38 36 36 8010 30 N67°56'23"W - 100.00' S63°16'15"E 60.09' 4 6 5.5 8034.4 8033.4 8032.6 803 7.5' UTILITY EASEMENT (RECEPTION N 800010" 8 00080008000REF. UP UP E209A 7' - 7" 17' - 2" 8021' - 0" E208A B46 B33 B32 16' - 0" 17' - 0" 9' - 0" 11' - 1" 8' - 4 1/2" 16' - 4" 12' - 0" 15' - 1" 20' - 1 5/8" 8' - 5 3/8" 8' - 6 5/8" 3' - 0" 7' - 6" 8026' - 0" 13' - 11" 3' - 11" 4' - 1" 12' - 1" 1' - 0" W203A 4' - 5" 3' - 9" 3' - 10" 2' - 10" 4' - 8 1/2" 4' - 8 1/2" 2' - 10" 4' - 1 1/2" 5' - 0" 5' - 0" 3' - 0" 6' - 8" 27' - 6" 4' - 2" 5 1/2" 4' - 2" 5' - 4 1/2" 12' - 0 1/2" Access door to crawl space under Landing and Master 13' - 0 1/2" 17' - 1" W204A 14' - 0" 2' - 0" 5' - 2" 3' - 2 1/2" 4' - 3" 3' - 4 1/2" 7' - 0" 8' - 0" W207A W208A 2' - 6" 35' - 0" 8021' - 0" 1' - 0" 13' - 0" 7' - 6" 6' - 6 1/2" 4 A4.2 2 A4.1 5 A4.1 4 A4.1 3 A4.2 2 A4.2 1 A4.2 8023' - 2" 8022' - 2" + 8 01 3 '-6 " + 8 0 2 1 ' 8015'-9" + 8021' + 8 030' + + 8031' 1 A4.1 Bedroom W-201 Closet W-202 Closet W-204 Bath W-203 Bedroom W-205 Family W-206 Stair A W-1 Laundry W-207 Mech W-208 Landing W-209 Master Bedroom W-210 His Closet W-211 ? ? Her Closet W-214 Landing W-209 Great Room E-201 Dining E-202 Kitchen E-203 Stair A E-2 Pantry E-205 Powder E-206 Master Bedroom E-207 Closet E-208 WC E-209 Master Bath E-210 Hall E-204 3' - 0" 3 A4.1 6 A4.1 3 A3.1 3 A3.1 W206A 1' - 4" 3' - 8 1/2" 9' - 4" 15' - 1" 2' - 0" 1' - 0 1/2" 8' - 4 1/2" 5 1/2" 8' - 0" 3 1/2" 6' - 2 1/2" 9 1/2" 8' - 11 1/2" 5 1/2" 14' - 2 1/2" 6" 7" WC W-212 6' - 11" 3 1/2" 6' - 3 1/2" 21' - 5" 25' - 3" 11' - 3 1/2" 12' - 2" 20' - 1 5/8" W206B 7' - 0 1/2" 10' - 0" 3' - 2" WET BAR 8 A4.2 6 A4.2 5 A4.2 17' - 0" 4' - 0 1/2" 15' - 7" 7" 1 A5.1 3 A5.1 A5.1 4 11 10 8 7 12 13 13 3 3 4 6 5 2 1 1 9 9 A A B B DF E E G G.1 H H.1 I I J K L M M C 9 1/2" 6 1/2" 8" 1 1/2" 6 1/2" 2 A5.1 R @ 7 1/4" 10 7' - 8" 2' - 8" 14' - 1 1/2" 14' - 4 1/2" 9' - 3 1/2" 3' - 11 1/2" 5 1/2" 3' - 11 1/2" 4" CONCRETE WALL IS 4" SOUTH OF CENTERLINE 5. FACE OF FRAMED WALL ABOVE TO ALIGN WITH CENTERLINE 5 1' - 0" 2' - 6" 7' - 4" 4' - 9" 8' - 0" 9' - 6" 4' - 5" A17 A16 W202A 3' - 6 1/2" 4' - 0 1/2" 5' - 6" E207A E210A W213A W203B W205A W203C W201A E201A W210A W211A W214A W212A ELEC PANELS 92% EFF (min) BOILER 8020' - 6" HOT TUB DISCONNECT B29 B31 B45 B30 B20 B23 A40 A39 A42 A41 B43 A31 A30 A29 A33 A34 B16 B17 B28 B27 B54 B18 B21 B19 B22 A26 A27 A28 7' - 6" 11' - 2 1/2" 5' - 4" 5' - 4" 3' - 7 1/2" 9" 3' - 1 1/2" 5' - 4" 3' - 7" R @ 7" 9 R @ 7 1/4" 10 HALF WALL GUARD (3'-6" ABOVE TREAD NOSING) SLOPE UNDER SIDE OF STAIR ABOVE B44 7 1/2" B42 3' - 5" 3' - 2" 4' - 6" 3' - 9" 4' - 2" 4' - 2 1/2" 4' - 2 1/2" 3' - 9" 7 1/2" 6" 12' - 6" 1' - 2" WOOD FRAMED STEP WITH STONE FINISH. PROVIDE WATERPROOFING MEMBRANE AT WALL EXTENDING UP THE WALL 24" TV B-VENT GAS FIREPLACE APPLIANCE TO BE SECTED BY CONTRACTOR 3' - 0" 7" 7' - 7 1/2" 3' - 8 1/2" 12' - 2 1/2" 1' - 1 1/2" 11' - 8" 2' - 6" 4' - 8 1/2" 4' - 6 1/2" RADON SYSTEM PIPING RADON SYSTEM PIPING 2' - 0 1/2" 2' - 0" 14' - 6" 13' - 6 1/2" 25' - 2" 53' - 2 1/2" 68' - 9 1/2" 3' - 11" 7' - 6" 20' - 0" 1' - 5" 4' - 1" 3' - 4 1/2" 4' - 0 1/2" 4' - 6" 4' - 0" 12' - 6 1/2" 80 gal SM CO SMOKE DETECTOR CO DETECTOR LEGEND SM SM SM SM SM SM CO CO SM COOKTOP HOOD CFM 400 CFM FD FD WEST-UNIT B EAST-UNIT A WEST-UNIT B EAST-UNIT A 12' - 0"5' - 0" 5' - 10 1/4" 7' - 4" SM 5' - 6" 5' - 0" E206A 2' - 2" 4' - 5 1/2" 5' - 6" 6' - 9" 5' - 6" 8' - 4 1/2" 6' - 0" SM CO 3 1/2" 3' - 3" E205A tall pantry cabinets 8' - 2 3/4" 6' - 7 1/2" 17' - 9" 14' - 4" 1' - 3" 1' - 6 3/4" 4' - 6" 3' - 0" 1' - 0" 5' - 7" 2' - 5" 1' - 0" 18' - 1 7/8" 15' - 10 1/2" 8016' 8014' 8010' 8012' 8008' 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date ConsultantAddress Address Phone Fax e-mail Consultant Address Address Phone Fax e-mail Consultant Address Address Phone Fax e-mail REVISIONS 5/15/2015 10:40:24 AM A2.2 Main Level Floor Plan 1220 Duplex at Snowberry PERMIT SET 10.11.14 Mountain C.I. Holdings Lot 9, Block 9, Vail Intermountain 2801 Snowberry Drive, West Vail, CO 81657 1/4" = 1'-0" 1 A2.0 Main Floor No. Description Date 1 REV #1 SNOW CLIPS AND FUNDATION WALL THICKNESS 10-01-12 4 Revision 4 roof ht west unit 09-20-13 ALL FOUNDATION WALLS ARE TO HAVE 4" PERFORATED PERIMETER DRAIN PIPING WITH FILTER FABRIC SLEEVE. REFER TO THE SOILS INVESTIGATION REPORT. IN ADDITION, THE TALL FOUNDATIO WALLS ARE TO HAVE 4" PERFORATED DRAIN PIPING WITH FILTER FABRIC SLEEVE AT 10'-0" SPACING ON THE UPHILL SIDE. ALL PERIMETER DRAIN SYSTEMS ARE TO BE COLLECTED AND TRANSFER TO A SOLID PIPIE AND EXTEND TO DAYLIGHT. ALL GUTTERS, DOWNSPOUTS ON THE SOUTH SIDE OF THE BUILDING ARE TO BE COLLECTED WITHIN A 4" SOLID PIPE UNDERGROUND COLLECTION SYSTEM. THIS SYSTEM IS TO BE LOCATED 4'-0" BELOW FINISHED SURFACE. DOWNSPOUTS ARE TO BE HEAT TAPED AND EXTEND 4'-0" BELOW FINISH SURFACE. UNDERGROUND COLLECTION SYSTEM IS TO EXTEND TO DAYLIGHT AWAY FROM THE BUILDING. FOUNDATION PERIMETER DRAIN SYSTEM: DOWNSPOUT UNDERGROUND UNDERDRAIN COLLECTION SYSTEM: EXISTING PLAN DRB APPROVED 6/12/2015 12:00:00 AM