HomeMy WebLinkAboutDRB150231_PV-E3_1434482220.pdfPREPARED BY:
Doni Nicoll
PROJECT ADDRESS:
1550 Matterhorn Circle
Vail, CO 81631
STAMP (if applicable)
DATE ISSUE DESIGNER
6/3/2015 Permit DJN
SUNSENSE REPRESENTATIVE:
Cristian Basso
Site Plan - Exploded View
SCALE: NTS
SHEET NUMBER:
PV-E3
KEY:
RESERVED FOR TOWN OF VAIL APPROVAL
JB
CT
IN
V
JB
MDP
Property Boundary48'-0"
Dwelling Outline
NOT IN SCOPE OF WORK
Rooftop J-Box
Transition from USE-2 / PV Wire to
THWN-2, Conductors are in 3
4" EMT/FMT.
AC Disconnect
(Non-Fused)
(Utility Accessible & Req'd)
Grid-tied Inverter
(Exterior)
Conduit Run
(Externally Ran)
Solar Electric Modules w/ Optimizers
(24 Modules & 24 Optimizers)
CT Cabinet & Utility Meter Enclosure
Combination Panel
(Existing and Exterior)
400A Rated
Multi-Dwelling
Building Outline
Main Electrical Distribution Panel
(Existing and Interior)
400A Main / 400A Rated
*POINT OF INTERCONNECTION
BACK-FED SYSTEM
S
N
E
W
Building
Outline
PV Modules
Slope
Electrical
Components
Area of
Work
JB
Racking
DRB
APPROVED
6/16/2015
12:00:00 AM