Loading...
HomeMy WebLinkAboutDRB150231_PV-E4_1434482220.pdfPREPARED BY: Doni Nicoll PROJECT ADDRESS: 1550 Matterhorn Circle Vail, CO 81631 STAMP (if applicable) DATE ISSUE DESIGNER 6/3/2015 Permit DJN SUNSENSE REPRESENTATIVE: Cristian Basso Electrical Schematic & Calculations SCALE: NTS SHEET NUMBER: PV-E4 RESERVED FOR TOWN OF VAIL APPROVAL 6 1A (1) STRING OF (12) MODULES CONDUCTORS EXPOSED TO FREE AIR OR IN EMT (4) 10 AWG USE-2, CU PV-WIRE CONDUCTORS & (1) #6 BARE CU GRND 3 1B (1) STRING OF (12) MODULES 2 4 Transition Box NEMA 3 (or equivalent) Inverter w/ Integrated DC Disconnect & Dual MPPT (Installed Exterior of Main Dwelling - See details on Sheet PV-E1 & PV-E2) 8 Main Electrical Distribution Panel 400A Main / 400A Buss EXISTING and INTERIOR *Point of Interconnection M Required Utility Accessible PV/AC Disconnect Lockable, with visible open (i.e. Knife Blade) 60A General Duty 240V / 2-Pole Non-Fused 11 CAT5 ETHERNET TO ONSITE ROUTER HOMEOWNER TO PROVIDE CAT5 CABLE TO INVERTER LOCATION. (IF APPLICABLE) OPTIONAL - FOR MONITORING AC Disco. Labeled: "PHOTOVOLTAIC SYSTEM DISCONNECT" 35A 400A UTILITY GRID (HCE) 120/240V, 1-Phase, 3 Wire Labeled: "WARNING! PHOTOVOLTAIC SYSTEM CONNECTED" CT Cabinet EXISTING & EXTERIOR (Feeds Main Distribution Panel inside) 9 10 400A 7 5 7 Sunsense to perform all DC Electrical Scope of Work On-Site Electrician to perform all AC Electrical Scope of Work DRB APPROVED 6/16/2015 12:00:00 AM