Loading...
HomeMy WebLinkAboutDRB150249_A2.3_1446736620.pdfUP UP UP DN A3.1 A3.2 A3.4 1 A3.3 1 1 1 3 A4.1 1 A4.1 2 A4.5 4 A4.1 GROTTO PATIO KITCHENETTE 5' - 3 1/8" 11' - 4 1/4" 26' - 11 1/8" 8' - 7" 26' - 0" 39' - 1 1/2" 6' - 0" 17' - 8 7/8" HOT TUB ROOF BELOW HOT TUB 13' - 11" ROOF BELOW 14' - 7" 14' - 10" 12' - 1" 2 A4.2 OWNER CLOSET 8394' - 6" CRAWLSPACE TO MEET T.O.VAIL REQ'S FOR N0N-GRFA CONSTRUCTED SPACE - MAX. 5'-0" EXISTING FOUNDATION WALL EXISTING FOUNDATION WALL EXISTING FOUNDATION WALL EXISTING FOUNDATION WALL EXISTING CRAWLSPACE UNDER GARAGE SLAB MEETS T.O.VAIL REQ'S FOR N0N- GRFA CONSTRUCTED SPACE EXISTING SLAB EXISTING SLAB EXISTING SLAB ON-GRADE PATIO ON-GRADE PATIO EXISTING STAIRS NEW STAIRS 1 A4.2 0' 2' 4' 8' 16' 3'-0"x4'-0" ACCESS DOOR (12 S.F. MAX. FOR GRFA CRAWLSPACE RESTRICTIONS) 12' - 8 1/4" 14' - 1 1/2" 4' - 6" 29' - 8" 13' - 8" 25' - 4" 1 1/2" 1 1/2" 9' - 8 1/2" 15' - 3 1/2" 7' - 9" 5' - 8 1/2" 14' - 4" 3' - 0" 16' - 0" 8' - 11 1/4" W205 E200 W209 W36 W37 W204 W200 E202 E06 E05 E04 W08 W09 W06 W07 E209 E210 E203 E207 E205 E204 E03 E01 E02 E07 E08 W201 W31 W12 W13 W29 W30 W28 W15 W14 FAMILY ROOM W200 BATH 2 W211 ELEV W204 7' - 9" 9' - 8" 7' - 5 1/2" 7" 24' - 10 1/2" DIRECT VENT GAS APPLIANCE FIREPLACE 12' - 6 1/2" 10' - 9 7/8" 13' - 7" 8" SETBACK SMOKE DETECTOR BATH VAN S 4' - 5 1/2" 3' - 11 3/4" 5 1/2" 4' - 9 1/4" 3' - 9" FAMILY ROOM E200 HALL E201 CLOSET E202 BEDROOM 2 E203 BATH 2 E204 LAUNDRY E205 STORAGE E206 BEDROOM 1 E207 CLOSET E209 CLOSET E210 5' - 0" 4' - 10" 3' - 1 1/2" 5' - 2" 7' - 0" 7' - 3" 7' - 1" (2) AIR-CONDITIONER CONDENSOR UNITS ON CONC. PAD W207 11' - 1" 3 1/2" 13' - 6" 1' - 2" BEDROOM 1 W201 W202 W206 W208 12' - 0" 8387' - 4" 8387' - 6" 8" 8' - 11 1/2" 6' - 4 1/2" 3' - 0" S S S S F F S 8387' - 6" F S 2' - 0" 2' - 6" 12' - 8" 8' - 2" 11' - 8 3/4" 20' - 11" 8" SLOPED 12' - 0" 8' - 0" 7' - 2" 12' - 11" SLOPED STONE WALL WITH CAP R @ 7 5/16" 12 R @ 7 1/2" 20 R @ 7 9/16" 16 2 A4.3 1 A4.3 3 A4.2 3 A4.2 3 A4.4 LINE OF CONC. SLAB 2 A4.4 1 A4.4 5 A4.1 8387' - 6" 1 A4.6 2 A4.1 1 A4.5 3' - 0" 8" 8" 3 1/2" 6' - 1" 3 1/2" 3' - 6" 3 1/2" 12' - 2" 5 1/2" F CONC. SHELF AT EXISTING FOOTING BATH 1 E208 F EXISTING FOOTING CREATES 8" CAVITY 8391' - 7" VERIFY STAIR OVERHANG ABOVE 1' - 0" 3 A4.5 2 A4.6 LEDGE AT EXIST FTG. 3 A4.6 REMOVE EXISTING CONC. WALL CHASE FOR FORCED AIR RADON PIPE 4 A4.6 HIGH-EFFICIENCY (MIN. 92%) DIRECT VENT, SEALED COMBUSTION FORCE-AIR FURNACE. WITH HEAT EXCHANGER FOR INDIRECT WATER HEATER. INTAKE AND EXHAUST: 2 PVC PIPES. INDIRECT WATER HEATER "SIDE-ARM" WATER STORAGE TANK WRAP W/ TANK INSULATION. RADON PIPE W/ CONNECTION FOR FAN 5 A4.6 2' - 4" 12' - 1" W203 BEDROOM 2 W203 CLOSET W112 BATH 1 W205 LAUNDRY W208 MECH W210 CLOSET W202 11 5/8" 4' - 6" 3 1/2" 4' - 11 3/4" 5 1/2" 2' - 0" 6' - 0 5/8" 5 1/2" 5' - 1" 11 1/2" W D W.H. FURNACE MECH. E212 HIGH-EFFICIENCY (MIN. 92%) DIRECT VENT, SEALED COMBUSTION BOILER FOR HEATED DRIVEWAY. INTAKE AND EXHAUST: 2 PVC PIPES. E206 TV ON WALL WINE-DISPLAY BACK-LIT DESIGN BY OTHERS 2 3' - 6" 3 1/2" 2 2 NEW FOUNDATION WALL 3 1/2" 3' - 6" 3 1/2" 8' - 7" 11 1/2" 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS PERMIT SUBMITTAL 5-6-15 6/22/2015 11:50:27 AM A2.3 LOWER LEVEL FLOOR PLAN 1406 Katsos Ranch Renovation PERMIT SET 5-6-15 6-5-15 Katsos Ranch, LLC 3235 Katsos Ranch Road, Vail CO 1/4" = 1'-0" 1 0. LOWER LEVEL No. Description Date 2 REV2 - Owner Comments 6-4-15 DRB APPROVED 11/4/2015 12:00:00 AM