Loading...
HomeMy WebLinkAboutDRB150249_A5.0_1446736620.pdf6" 3' - 1 1/8" 3' - 9 7/8" 3' - 6" 5 3/4" 2' - 2 3/4" 5' - 10 3/8" 6' - 8 7/8" 3' - 6 5/8" 6 3/8" 3' - 6" 3' - 6" 7 5/8" 3' - 6" 7/8" 8415' - 3 5/16" 8411' - 7 3/4" 8408' - 0 1/2" 2' - 9 7/8" 4' - 5" 11" 4' - 8 5/16" 6' - 0" EXTERIOR LIGHT FIXTURE (TYP.) E301 2' - 4 1/4" 2 3/4" 3' - 3 7/16" W11 W10 W13 W12 4' - 9" 7' - 0" 6' - 3 1/8" W05 W04 6' - 0" 1' - 10 3/8" 25'-0" RADIUS 8405' - 7" 8" 6' - 0" 7" 6' - 2 1/2" W300 W38 W39 2' - 6 13/16" 3' - 6 11/16" 3' - 7 5/8" 4' - 8 1/16" STUCCO SIDING (RE: ELEVS) OVER THERMAL AND AIR-INFILTRATION BARRIER OVER PLYWOOD SHEATHING WATERPROOF MEMBRANE WINDOW TAPE OVER NAILING FLANGE SEALANT BEHIND NAILING FLANGE 5/8" GWB OVER VAPOR RETARDER OVER 2X6 EXTERIOR WALL STUDS CAVITY INSULATION RE: SECTIONS PRE-FAB INSULATED HEADER WOOD CASING PROFILE TBD BACKER ROD AND SEALANT SHIM SPACE WOOD CASING PROFILE TBD BACKER ROD AND SEALANT WATERPROOF MEMBRANE TAPE TO OVERLAP AIR - INFILTRATION BARRIER AND EXTEND OVER ROUGH SILL 5/8" GWB OVER VAPOR RETARDER OVER 2X6 EXTERIOR WALL STUDS WATERPROOF MEMBRANE WINDOW TAPE EXTERIOR INTERIOR EXTERIOR STUCCO SIDING (RE: ELEVS) OVER THERMAL AND AIR-INFILTRATION BARRIER OVER PLYWOOD SHEATHING WOOD SIDING (RE: ELEVS) OVER THERMAL AND AIR-INFILTRATION BARRIER OVER PLYWOOD SHEATHING FLASHING 2X_ WOOD HEADER (RE: ELEVS) W/ SLOPED TOP WATERPROOF MEMBRANE WINDOW TAPE OVER NAILING FLANGE SEALANT BEHIND NAILING FLANGE 5/8" GWB OVER VAPOR RETARDER OVER 2X6 EXTERIOR WALL STUDS CAVITY INSULATION RE: SECTIONS PRE-FAB INSULATED HEADER WOOD CASING PROFILE TBD BACKER ROD AND SEALANT SHIM SPACE 2X_ WOOD SILL (RE: ELEVS) W/ SLOPED TOP DRIP NOTCH WOOD CASING PROFILE TBD BACKER ROD AND SEALANT WATERPROOF MEMBRANE TAPE TO OVERLAP AIR - INFILTRATION BARRIER AND EXTEND OVER ROUGH SILL 5/8" GWB OVER VAPOR RETARDER OVER 2X6 EXTERIOR WALL STUDS 2X_ WOOD SILL (RE: ELEVS) WATERPROOF MEMBRANE WINDOW TAPE EXTERIOR INTERIOR EXTERIOR WOOD SIDING (RE: ELEVS) OVER THERMAL AND AIR-INFILTRATION BARRIER OVER PLYWOOD SHEATHING 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 6/22/2015 11:54:40 AM A5.0 SCHEDULES 1406 Katsos Ranch Renovation PERMIT SET 5-6-15 6-5-15 Katsos Ranch, LLC 3235 Katsos Ranch Road, Vail CO No. Description Date 1 REV1 - Vail Comments 5-18-15 2 REV2 - Owner Comments 6-4-15 WINDOW SCHEDULE Mark Ty pe Ma rk Family Type Width Height Comments E60 F Window-Casement 30x60 2' - 6" 5' - 0" E61 P Window-Picture 42x42 3' - 6" 3' - 6" E62 P Window-Picture 42x42 3' - 6" 3' - 6" W01 Z Window-Casement 42x60 3' - 6" 5' - 0" Egress W02 G Window-Picture 42x60 3' - 6" 5' - 0" W03 Z Window-Casement 42x60 3' - 6" 5' - 0" W04 K Window-Casement 36x48 3' - 0" 4' - 0" Egress W05 K Window-Casement 36x48 3' - 0" 4' - 0" W06 D Window-Casement 36x54 3' - 0" 4' - 6" Egress W07 D Window-Casement 36x54 3' - 0" 4' - 6" W08 D Window-Casement 36x54 3' - 0" 4' - 6" Egress W09 D Window-Casement 36x54 3' - 0" 4' - 6" W10 Q Window-Picture 42x24 3' - 6" 2' - 0" W11 Q Window-Picture 42x24 3' - 6" 2' - 0" W12 G Window-Picture 42x60 3' - 6" 5' - 0" Tempered W13 G Window-Picture 42x60 3' - 6" 5' - 0" Tempered W14 G Window-Picture 42x60 3' - 6" 5' - 0" Tempered W15 G Window-Picture 42x60 3' - 6" 5' - 0" Tempered W16 R Window-Picture 54X72 4' - 6" 6' - 0" W17 R Window-Picture 54X72 4' - 6" 6' - 0" W18 R Window-Picture 54X72 4' - 6" 6' - 0" W19 R Window-Picture 54X72 4' - 6" 6' - 0" W20 S Window-Awning 54x20 4' - 6" 1' - 8" Tempered W21 S Window-Awning 54x20 4' - 6" 1' - 8" Tempered W22 S Window-Awning 54x20 4' - 6" 1' - 8" Tempered W23 S Window-Awning 54x20 4' - 6" 1' - 8" Tempered W24 T Window-Picture 54x36 4' - 6" 3' - 0" W25 T Window-Picture 54x36 4' - 6" 3' - 0" W26 T Window-Picture 54x36 4' - 6" 3' - 0" W27 T Window-Picture 54x36 4' - 6" 3' - 0" W28 H Window-Picture 36x60 3' - 0" 5' - 0" Tempered W29 H Window-Picture 36x60 3' - 0" 5' - 0" Tempered W30 H Window-Picture 36x60 3' - 0" 5' - 0" Tempered W31 H Window-Picture 36x60 3' - 0" 5' - 0" Tempered W32 H Window-Picture 36x60 3' - 0" 5' - 0" W33 H Window-Picture 36x60 3' - 0" 5' - 0" W34 A Window-Awning 36x24 3' - 0" 2' - 0" W35 A Window-Awning 36x24 3' - 0" 2' - 0" W36 A Window-Awning 36x24 3' - 0" 2' - 0" W37 A Window-Awning 36x24 3' - 0" 2' - 0" W38 C Window-Casement 36x60 3' - 0" 5' - 0" W39 C Window-Casement 36x60 3' - 0" 5' - 0" W41 U Window-Picture 30x24 2' - 6" 2' - 0" W42 U Window-Picture 30x24 2' - 6" 2' - 0" W43 U Window-Picture 30x24 2' - 6" 2' - 0" W45 V Window-Awning 30"X24" 2' - 6" 2' - 0" W46 V Window-Awning 30"X24" 2' - 6" 2' - 0" W47 V Window-Awning 30"X24" 2' - 6" 2' - 0" W48 W Window-Casement 30x72 2' - 6" 6' - 0" W49 W Window-Casement 30x72 2' - 6" 6' - 0" Egress W50 F Window-Picture 72x72 6' - 0" 6' - 0" W51 A Window-Awning 36x24 3' - 0" 2' - 0" Grand total: 111 363' - 6" 410' - 7" WINDOW SCHEDULE Mark Ty pe Ma rk Family Type Width Height Comments E01 B Window-Casement 36x65 3' - 0" 5' - 5" U-.32 typical E02 B Window-Casement 36x65 3' - 0" 5' - 5" E03 B Window-Casement 36x65 3' - 0" 5' - 5" E04 C Window-Casement 36x60 3' - 0" 5' - 0" Egress E05 C Window-Casement 36x60 3' - 0" 5' - 0" E06 C Window-Casement 36x60 3' - 0" 5' - 0" E07 D Window-Casement 36x54 3' - 0" 4' - 6" E08 D Window-Casement 36x54 3' - 0" 4' - 6" Egress E09 E Window-Picture 48x60 4' - 0" 5' - 0" E10 F Window-Awning 48X20 4' - 0" 1' - 8" Tempered E11 D Window-Picture 48x24 4' - 0" 2' - 0" E12 E Window-Picture 48x60 4' - 0" 5' - 0" E13 F Window-Awning 48X20 4' - 0" 1' - 8" Tempered E14 D Window-Picture 48x24 4' - 0" 2' - 0" E15 E Window-Picture 48x60 4' - 0" 5' - 0" E16 F Window-Awning 48X20 4' - 0" 1' - 8" Tempered E17 D Window-Picture 48x24 4' - 0" 2' - 0" E18 G Window-Awning 36x20 3' - 0" 1' - 8" Tempered E19 G Window-Awning 36x20 3' - 0" 1' - 8" Tempered E20 H Window-Picture 36x60 3' - 0" 5' - 0" Tempered E21 H Window-Picture 36x60 3' - 0" 5' - 0" Tempered E22 H Window-Picture 36x60 3' - 0" 5' - 0" Tempered E23 H Window-Picture 36x60 3' - 0" 5' - 0" Tempered E24 G Window-Awning 36x20 3' - 0" 1' - 8" E25 G Window-Awning 36x20 3' - 0" 1' - 8" E26 H Window-Picture 36x60 3' - 0" 5' - 0" E27 H Window-Picture 36x60 3' - 0" 5' - 0" E28 G Window-Picture 42x60 3' - 6" 5' - 0" E29 J Window-Awning 42x18 3' - 6" 1' - 6" E30 G Window-Picture 42x60 3' - 6" 5' - 0" E31 J Window-Awning 42x18 3' - 6" 1' - 6" E32 G Window-Picture 42x60 3' - 6" 5' - 0" E33 J Window-Awning 42x18 3' - 6" 1' - 6" E34 K Window-Casement 36x48 3' - 0" 4' - 0" Egress E35 K Window-Casement 36x48 3' - 0" 4' - 0" E36 L Window-Awning 24x24 2' - 0" 2' - 0" E37 L Window-Awning 24x24 2' - 0" 2' - 0" E38 L Window-Awning 24x24 2' - 0" 2' - 0" E39 L Window-Awning 24x24 2' - 0" 2' - 0" E40 L Window-Awning 24x24 2' - 0" 2' - 0" E41 D Window-Casement 36x54 3' - 0" 4' - 6" Egress E42 L Window-Awning 24x24 2' - 0" 2' - 0" E43 L Window-Awning 24x24 2' - 0" 2' - 0" E44 L Window-Awning 24x24 2' - 0" 2' - 0" E45 D Window-Casement 36x54 3' - 0" 4' - 6" E46 Q Window-Picture 30x60 2' - 6" 5' - 0" E47 F Window-Casement 30x60 2' - 6" 5' - 0" Egress E48 D Window-Casement 36x54 3' - 0" 4' - 6" Egress E49 A Window-Awning 36x24 3' - 0" 2' - 0" E50 N Window-Casement 45" x 60 3' - 9" 5' - 0" Egress E51 N Window-Casement 45" x 60 3' - 9" 5' - 0" E52 G Window-Picture 42x60 3' - 6" 5' - 0" E53 P Window-Picture 42x42 3' - 6" 3' - 6" E54 P Window-Picture 42x42 3' - 6" 3' - 6" E55 P Window-Picture 42x42 3' - 6" 3' - 6" E56 G Window-Picture 42x60 3' - 6" 5' - 0" E57 J Window-Awning 42x18 3' - 6" 1' - 6" Tempered E58 P Window-Picture 42x42 3' - 6" 3' - 6" E59 P Window-Picture 42x42 3' - 6" 3' - 6" EAST UNIT NEW WINDOWS WEST UNIT NEW WINDOWS EXISTING WINDOWS Mark Family Width Height Comments EX1 Window-Casement 2' - 0" 3' - 6" EX2 Window-Casement 3' - 0" 5' - 0" EX3 Window-Picture 5' - 1" 5' - 6" EX5 Window-Picture 5' - 1" 5' - 6" WX1 Window-Picture 3' - 6" 6' - 6" WX2 Window-Picture 3' - 6" 6' - 6" Grand total: 6 22' - 2" 32' - 6" DOOR SCHEDULE Mark Width Height Comments E200 7' - 0" 8' - 0" E202 2' - 4" 7' - 0" E203 2' - 8" 7' - 0" E204 2' - 4" 7' - 0" E205 2' - 8" 7' - 0" E206 3' - 0" 4' - 0" E207 2' - 8" 7' - 0" E209 E210 E300 18' - 0" 7' - 0" E301 6' - 0" 8' - 0" E302 2' - 4" 7' - 0" E303 7' - 0" 8' - 0" E305 2' - 10" 7' - 0" REPLACE E307 2' - 4" 7' - 0" E308 3' - 0" 7' - 0" E401 4' - 8" E402 2' - 4" 7' - 0" E403 2' - 4" 7' - 0" E405 2' - 4" 7' - 0" E406 2' - 4" 7' - 0" E407 2' - 8" 7' - 0" E408 2' - 8" 7' - 0" E410 2' - 8" 7' - 0" E411 2' - 4" 7' - 0" E412 E413 2' - 8" 7' - 0" E414 2' - 4" 7' - 0" E415 2' - 6" 7' - 0" W001 3' - 0" 7' - 0" W002 5' - 0" 8' - 0" W003 W004 3' - 0" 7' - 0" W005 3' - 0" 7' - 0" W006 2' - 6" 7' - 0" W100 3' - 0" 7' - 0" W101 3' - 0" 7' - 0" W102 3' - 0" 7' - 0" W104 3' - 0" 7' - 0" W105 2' - 6" 7' - 0" W106 2' - 6" 7' - 0" W107 3' - 0" 0" W108 2' - 6" 7' - 0" W108a 3' - 0" 7' - 0" W108b 3' - 0" 7' - 0" W110 W111 W112 2' - 8" 7' - 0" W113 3' - 0" 8' - 0" W114 W200 3' - 0" 8' - 0" W201 2' - 8" 7' - 0" W202 2' - 8" 7' - 0" W203 2' - 6" 7' - 0" W204 3' - 0" 7' - 0" W205 5' - 0" 7' - 0" W206 2' - 8" 7' - 0" W207 2' - 4" 7' - 0" W208 5' - 0" 7' - 0" W209 2' - 6" 7' - 0" W300 6' - 2 1/2" 8' - 0" W301 6' - 2 1/2" 8' - 0" W302 3' - 0" 7' - 0" W303 3' - 0" 7' - 0" W304 3' - 0" 7' - 0" W305 W307 2' - 0" 7' - 0" USE EXISTING - VERIFY W308 2' - 4" 7' - 0" Grand total: 68 203' - 9" 411' - 0" 1/2" = 1'-0" 1 ENL. WINDOW ELEVATION - EAST 1 1/2" = 1'-0" 2 ENL. WINDOW ELEVATION - EAST 2 1/2" = 1'-0" 4 ENL. WINDOW ELEVATION - SOUTH 1 1/2" = 1'-0" 5 ENL. WINDOW ELEVATION - SOUTH 2 1/2" = 1'-0" 3 ENL. WINDOW ELEVATION - WEST TOTAL NEW WINDOW = 146,364 SF TOTAL EXIST. WINDOW = 718 SF 1 1/2" = 1'-0" 6 WINDOW DETAIL STUCCO 1 1/2" = 1'-0" 7 WINDOW DETAIL WOOD INSULATION SUMMARY ALL MINIMUM INSULATION VALUES FROM IRC 2012 ROOF JOIST CAVITY = R-56 (NON-VENTED) (MIN. R-49) EXTERIOR WALL INSULATION = R-22 (MIN. R-20) BASEMENT WALL INSULATION = R-24 / R-19 (MIN. R-19) SLAB PERIMETER INSULATION = R-10 (MIN. R-10) UNDER-SLAB INSULATION = R-10/ R-15 (MIN. R-10) FLOOR OVER UNCONDITIONED = R-30 (MIN. R-30) WINDOWS U-VALUE MAX. = U-.30 (MAX. U-.32) INSULATION SUBCONTRACTOR MUST VERIFY THAT R-VALUES OF PROPRIETARY PRODUCTS MEET OR EXCEED THE R-VALUES LISTED ABOVE AND THAT INSTALLATION PERFORMED PER MANUFACTURER'S SPECIFICATIONS. ALL INSULATION SHALL COMPLETELY FILL STUD/JOIST SPACES AND HAVE PROPER AIR-BARRIER SHEATHING ON BOTH SIDES OF THE STUD/JOIST SPACES. WINDOW NOTES: 1. ALL WINDOWS SHALL BE DOUBLE-PANED WOOD WINDOWS W/ ALUM. CLADDING OR FIBERGLASS. 2. U-VALUE OF .32 MAXIMUM (SEE INSULATION SUMMARY BELOW). 3. ALL WINDOWS TO RECEIVE LOW-E TREATMENT. 4. ALL SIZES SHOWN ARE NOMINAL. CONTRACTOR TO VERIFY ROUGH-OPENING SIZES WITH CHOSEN WINDOW MANUFACTURER. 5. EXISTING WINDOWS IN EXISTING WALLS ONLY (NO RE-USE IN NEW WALLS). 6. WINDOWS MUST DISPLAY MANUFACTURER SPECS INCLUDING R-VALUES PRIOR TO T.O.VAIL INSPECTIONS. T2 T1 T3 T4 T5 T6 T7 T8 T10 T11 T12 1 2 DRB APPROVED 11/4/2015 12:00:00 AM