Loading...
HomeMy WebLinkAboutDRB150337_A1_1438727520.pdfDN DN DN DN DN DN DN 49'-2" 48'-4" 47'-11" 48'-0" 47'-9" 48'-3" 8330 8340 8350 8320 8320 8330 8340 8360 8350 8360 8370 SEVERAL ASPEN TREES WILL BE REMOVED AT NEW DECK EXPANSION LANDSCAPE NOTE: NO LANDSCAPE IMPROVEMENTS PROPOSED APPROX LOCATION OF NEIGHBOR DRIVEWAY APPROX. LOCATION OF EXISTING RIP- RAP DRAINAGE SWALE NEW STONE WALL SEWER S S S S S S S S S S S S S S S S W W W W CONTRACTOR TO VERIFY EXACT LOCATION OF SEWER LINE BEFORE DIGGING NEW DECK FOUNDATIONS 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/23/2015 11:21:45 AM A1 COVER + SITE PLAN xxxx BRIAR PATCH IMPROVEMENTS PERMIT SET 7-23-15 7-23-15 BRIAR PATCH UNITS 1390 Briar Patch Ln, Vail, CO UNITS 1, 2, & 3 1" = 10'-0" 1 0. SITE PLAN N ILC INFORMATION BRIAR PATCH TOWNHOUSES EXTERIOR IMPROVEMENTS BRIAR PATCH MAP VICINITY MAP UNIT 1 GRFA: GRFA ALLOWED = 1,883.33 s.f. GRFA EXISTING = 2,256 s.f. GRFA AVAILABLE = 0 s.f. (NON-CONFORMING) GRFA INCREASE = 0 s.f SITE COVERAGE ALLOWED = 6,300 s.f. (ENTIRE TRIPLEX) SITE COVERAGE EXISTING = 4,389 s.f. SITE COVERAGE PROPOSED = 4,433 s.f. SITE COVERAGE INCREASE = +44 s.f. ZONING SUMMARY Multi-Family Townhouse located in Vail, Colorado Subdivision: Residences at Briar Patch Unit 1, Unit 2, Unit 3 Unit 1: Address: 1390 Briar Patch Lane Unit #1 Parcel: 2103-121-21-007 Owner: Christine Santucci and Gregory Hansen 1499 Blake St. Apt. 9E Denver, CO 80202-1360 Unit 2: Address: 1390 Briar Patch Lane Unit #2 Parcel: 2103-121-21-008 Owner: Thomas & Marina Bogard 920 Shady Oak Lane Castle Rock, CO 80108-8867 Unit 3: Address: 1390 Briar Patch Lane Unit #3 Parcel: 2103-121-21-009 Owner: Ralph E. Christoffersen QPR Trust 1995 Stony Hill Road Boulder, CO 80305-6824 PROJECT / CODE SUMMARY Class of Work: Adddition / Renovation Type of Construction: Type V-N Type of Occupancy: R1 (multi family) Levels: 2-story - over basement Sprinklers: No Automatic Sprinkler System Town of Vail Adopted Codes: 2012 International Building Code (IBC) including "Fire Resistance Design Manual" 2012 International Residential Code (IRC) including Appendix F & G 2012 International Fire Code MIN. LANDSCAPE AREA (NOT APPLICABLE) GRFA AND SITE COVERAGE NUMBERS ARE ASSIGNED BY PLAT DESCRIPTION. SEE THE PLAT DATED 8-24-11 AND NAMED "AMENDED FINAL PLAT - FIFTH AMENDEMENT TO THE RESIDENCES AT BRIAR PATCH" FOR FURTHER DESCRIPTION. ARCHITECTURAL SHEET LIST Sheet Number Sheet Name A1 COVER + SITE PLAN A2.1 BASEMENT FLOOR PLAN A2.2 MAIN LEVEL FLOOR PLAN A2.3 ENTRY LEVEL FLOOR PLAN A2.4 LOFT LEVEL FLOOR PLAN A3.1 WEST (FRONT) ELEVATION A3.2 EAST ELEVATION A3.3 SOUTH ELEVATION A3.4 NORTH ELEVATION A4.1 1. BUILDING SECTION A4.2 2. BUILDING SECTION A4.3 3. BUILDING SECTION A4.4 WALL SECTIONS A5.1 DETAILS & HEIGHT CALCS A6.1 AREA PLANS UNIT 3 UNIT 2 UNIT 1 SEE SHEET A5 FOR ALL AREA PLANS, SCHEDULES, AND CALCULATIONS UNIT 2 GRFA: GRFA ALLOWED = 2,642.33 s.f. GRFA EXISTING = 2,201 s.f. GRFA PROPOSED = 2,313 s.f. GRFA INCREASE = +112 s.f. UNIT 3 GRFA: GRFA ALLOWED = 2,642.33 s.f. GRFA EXISTING = 3,368 s.f. GRFA AVAILABLE = 0 s.f. (NON-CONFORMING) GRFA INCREASE = 0 s.f. UNIT 1 HEIGHT = 40'-0" (ALLOWED 33'-0") NON-CONFORMING UNIT 2 HEIGHT = 40'-0" (ALLOWED 33'-0") NON-CONFORMING UNIT 3 HEIGHT = 44'-0" (ALLOWED 33'-0") NON-CONFORMING EXISTING PHOTOS MATERIALS AND COLORS LIGHTING LEGEND COUNT: (20) WALL SCONCE LIGHT FIXTURES. COUNT: (4) RECESSED CANS IN SOFFIT. SEE RED CIRCLES ON SITE PLAN. SEE FIXTURES ON ELEVATIONS. HAMPTON BAY EXTERIOR WALL LANTERN "QUARRY" NATURAL SLATE, BRONZE, & FROSTED AMBER SHADE RETROFIT WITH SHIELD SHOWN SIZE: 6" W x 13.6" H x 8.8" D RETROFIT W/ SHIELD FOR DARK NIGHT SKY COMPLIANCE PROJECT NARRATIVE The Briar Patch Townhouses Consist of (3) Townhouse units. Collective Improvements: The front elevation (west) will see the addition of stone veneer, stone walls, metal canopies, and new garage doors. The other elevations will see the addition of new stucco, new composite siding, new wood fascias/soffits, and trim, new lighting fixtures, and new metal railings. Unit 1 Improvements: The lower deck will be expanded and will include an outdoor gas fireplace. A new stair on the north elevation will connect the main and lower level decks. Unit 2 Improvements: The Main level rear deck will be expanded and connected to the lower level deck via new spiral staircase. The Dining Room is expanded with a minor additions. The Basement Level Bedroom 2 is expanded via addition. Unit 3 Improvements: The Upper Level roof deck will be expanded to the south and a new solid railing will be added to the south on-grade stairs to mitigate snow/mud accumulation on the stairs. Some windows/doors will be replaced and will match white color (Unit 3 only). No. Description Date 1 Revision 1 Date 1 STRUCTURAL SHEET LIST S1.1 GENERAL NOTES S2.1 FOUNDATION PLAN S2.2 MAIN LEVEL FRAMING PLAN S2.3 ENTRY/GARAGE LEVEL FRAMING PLAN S2.4 LOFT LEVEL FRAMING PLAN S2.5 ROOF FRAMING PLAN S3.1 FOUNDATION & FRAMIN DETAILS DRB APPROVED 8/4/2015 12:00:00 AM