Loading...
HomeMy WebLinkAboutDRB150486_A3-1_1446737280.pdfUP E04' E14' E12' LOT 7 G 8 10 8 4 6 8 6 8 4 2 4 10 8 4 4 8 8 10 10 12 14 12 6 8 E10' DN UP A4.3 A4.4 1 1 A4.1 A4.2 1 1 T.O. CONC. 0' - 11" T.O. FINISH 0' - 11 3/4" T.O. CONC. 2' - 8 3/4" 6' - 4" 7' - 0" 4' - 0" 4' - 0" 7' - 3" 6' - 0" 3' - 1" 3' - 5 3/8" 5' - 11" BEDROOM #5 015 AV EQUIP. ROOM 012 STORAGE 009 LAUNDRY ROOM 006 POWDER 005 MECHANICAL ROOM 008 W.C. 010 BATH 011 SHOWER ROOM 013 CLOSET 014 HALLWAY 007 WET STORAGE 004 WINE ROOM 003 STAIRS 002 WASHER DRYER EXERCISE AREA BENCH SHOWER BENCH 3' - 0" EXERCISE EQUIPMENT STORAGE 017 FD BUNKBED SELVING W/ MECHANICAL DUCTS ABOVE 4 5/8" 4" FD FD 5' - 2" 5' - 3" A4.5 1 A4.5 2 1 A5.5 1 A5.7 1 A5.6 2 A5.5 A4.5 3 FAMILY ROOM 001 1 A5.1 4 A5.5 1 A6.1 3 A6.1 1 A6.2 3 A6.2 2 A6.2 5 A6.2 4 A6.1 FD 5 A6.1 1 A6.3 2 A6.3 6 A6.1 3 A6.3 2 A6.3 2 A6.3 LINE OF WALL ABOVE 1 A5.2 1 A5.3 1 A5.4 2 A5.4 3 A5.5 1 A5.8 1 A5.9 008A 005A 006A 009A 011A 013A 010A 014A 012A 015A 017A 004A 004B 003A 013B TILE WOOD EPOXY WOOD TILE CARPET CARPET WOOD WOOD WOOD EPOXY EPOXY 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 A A B B C C D D E E F F G G J J K K L L G1 G4 GD GD GC GC GA GA GB GB H H I I G5 G2 001 002 2' - 4" 3' - 6 1/2" 4' - 5 1/2" 14' - 11 1/2" 1' - 0 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 1' - 10" 80' - 8" 17' - 4 1/2" 5' - 5 1/2" 1' - 2" 5' - 5 1/2" 29' - 5 1/2" 1' - 9 1/2"8' - 6 1/2"13' - 2" 23' - 6" 1' - 2" 1' - 0" 1' - 4"10" 12' - 3" 3' - 6" 1' - 7" 6' - 0" 2' - 0 7/8" 4' - 11 1/8" 3' - 0" 37' - 8" Q Q CONCRETE PATIO CONCRETE STAIRS 5 1/2" 7 1/2" 7 1/2" 5 1/2" 3 A6.3 NO INSULATION UNDER SLAB IN WINE ROOM. NO RADIANT HEAT IN WINE ROOM SLAB NO FOUNDATION WALL INSULATION @ WINE ROOM T.O. CONC. 3' - 0 3/4" @ PERIMETER G3 1 A6.1 2 3/16" 9 3/16" 3 A5.7 FD HB FLOOR DRAIN FLOOR PLAN GENERAL NOTES: 1. DOWNSPOUTS - RUN IN SOLID PIPE BELOW GRADE TO DAYLIGHT. (DO NOT CONNECT TO PERIMETER DRAIN SYSTEM) PROVIDE HEAT TAPE TYPICAL. 2. SLOPE SLAB @ MECHANICAL, WET STORAGE, AND CONC. MIN. 1/8":12" TO DRAINS ADJUST SLOPES AS REQUIRED 3. MOTORIZED SHADE WITH SHADE POCKETS TO BE PROVIDE AT LIVING ROOM SOUTH WINDOWS, DOOR, ALL BEDROOM WINDOWS, AND LARGE BATHROOM WINDOWS. 4. SEE A10.1-A10.3 FOR RCPs WITH SHADE VALANCE DETAIL CALL OUTS. 5. PROVIDE PERFORATED DRAIN @ PERIMETER AS SHOWN IN SECTION, DETAIL, SPEC, & SOILS REPORT RUN TO DAYLIGHT 6. RE: WINDOW SCHEDULE FOR WINDOWS AND DOORS W/ SHADE POCKET ABOVE. 7. SEE INTERIOR ELEVATION SHEETS FOR 1/2" = 1'-0" PLANS AND ELEVATIONS OF KITCHEN, BATHROOMS AND BUILT- INS. PROPOSED SQUARE FOOTAGE ANALYSIS: 3090 Booth Creek Drive, VAIL, CO Zone District: Two-Family Primary/Secondary Residential ( PS ) Lot is .3.28 acres, equal to 14,288 SF Allowable GRFA .46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.46 equals 4,600 SF .38 SF per 1 SF of site area > 10,000 SF of site area 5,000 x 0.38 equals 1,629 SF .13 SF per 1 SF of site area > 10,000 SF of site area 6,026 x 0.13 equals 0 SF _______________________________________________________________________________ Total Allowed Gross Residential Floor Area (GRFA) for entire lot 6,229 SF Proposed Square Footage Summary (Both Sides of Duplex Combined) Habitable SF GRFA Lower Level 2,247.25 SF 902.5 SF *1 Main Level 2,258.5 SF 2,258.5 SF Upper Level 2,139.5 SF 2,139.5 SF Garage area over 600 SF 0 SF Double height space___________________________649 SF___________ Total 6645.25 SF 5949.5 SF Total Remaining GRFA 279.5 SF *1 59% of the Lower Level wall is above existing or finished grade whichever was more restrictive, therefore 41% of the Lower Level SF is counted as GRFA (LOWER LEVEL HABITABLE 2,247 SF * .41 = 902.5 SF) NOTE- THESE NUMBER ARE APPROXIMATE UNTIL SUBGRADE AREA CALCS ARE COMPLETED Site Coverage Allowable Site Coverage is 20% of the lot 2,858 SF Proposed Site Coverage 2,810.5 SF Proposed Site Coverage for Roofs beyod 4' 34.00 SF Total Proposed Site Coverage 2,844.5 SF Total Remaining Site Coverage both sides 13.5 SF Landscape Area Lot Size 14,288 SF 60% Landscape Area Requirement 8,572.8 SF Lot Size 14,288 SF LESS Building Footprint / Driveway -5,092.5 SF Total Landscape Area 9,195.5 SF Total Hardscape Area Provided (8.3%) 1,666 SF Total Softscape Area Provided 7,529 SF Proposed driveway with snowmelt 2,282 SF Proposed snowmelt @ south patio/ Firepit 253.5 SF Proposed snowmelt zone to lower level 299 SF Setbacks 20' from front 15' from sides 15' from rear Patio can extend to 1/2 the distance of the setback Decks can encroach set back 5' Roof or architectural projections can encroach 4' Height Flat or mansard roofs not to exceed 30' Sloping roof not to exceed 33' Garage Allow 600 sq. ft. per unit. before area counts towards GRFA 552 SF is provided. Parking Required per Chapter 10 Primary dwelling unit is more than 5,500 SF GRFA 5 spaces are required. 2 covered 9' x 18' (in garage) and 3 uncovered 9' x 19' parking spaces are provided. Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 10/12/2015 11:38:58 AM A3.1 LOWER LEVEL FLOOR PLAN CWF HB REIMERS RESIDENCE 10/12/2015 3090 BOOTH CREEK DR. VAIL, CO TOV FINAL DRB SUBMITTAL 0' 2' 4' 8' 16' 1/4" = 1'-0" 1 LOWER LEVEL FLOOR PLAN NORTH No. Revision Date Revision Description DRB APPROVED 11/4/2015 12:00:00 AM