HomeMy WebLinkAboutDRB150486_A3-1_1446737280.pdfUP
E04'
E14'
E12'
LOT 7
G
8
10
8
4 6 8
6 8
4
2
4
10
8
4
4
8
8
10
10
12
14
12
6 8
E10'
DN
UP
A4.3
A4.4
1
1
A4.1
A4.2
1
1
T.O. CONC. 0' - 11"
T.O. FINISH 0' - 11 3/4"
T.O. CONC. 2' - 8 3/4"
6' - 4"
7' - 0"
4' - 0"
4' - 0"
7' - 3" 6' - 0"
3' - 1"
3' - 5 3/8"
5' - 11"
BEDROOM #5
015
AV EQUIP. ROOM
012
STORAGE
009
LAUNDRY ROOM
006
POWDER
005
MECHANICAL
ROOM
008
W.C.
010
BATH
011
SHOWER ROOM
013
CLOSET
014
HALLWAY
007
WET STORAGE
004
WINE ROOM
003
STAIRS
002
WASHER
DRYER
EXERCISE AREA
BENCH
SHOWER
BENCH
3' - 0"
EXERCISE
EQUIPMENT
STORAGE
017
FD
BUNKBED
SELVING W/
MECHANICAL DUCTS
ABOVE
4 5/8"
4"
FD
FD
5' - 2"
5' - 3"
A4.5
1
A4.5
2
1
A5.5
1
A5.7
1
A5.6
2
A5.5
A4.5
3
FAMILY ROOM
001
1
A5.1
4
A5.5
1
A6.1
3
A6.1
1
A6.2
3
A6.2
2
A6.2
5
A6.2
4
A6.1
FD
5
A6.1
1
A6.3
2
A6.3
6
A6.1
3
A6.3
2
A6.3
2
A6.3
LINE OF WALL ABOVE
1
A5.2
1
A5.3
1
A5.4
2
A5.4
3
A5.5
1
A5.8
1
A5.9
008A
005A
006A
009A
011A
013A 010A
014A
012A
015A
017A
004A
004B
003A
013B
TILE
WOOD EPOXY
WOOD
TILE CARPET
CARPET WOOD
WOOD
WOOD
EPOXY
EPOXY
1
1
2
2
3
3
4
4
5
5 6
6 7
7 8
8 9
9
10
10 11
11 12
12
A
A
B
B
C
C
D
D
E
E
F
F
G
G
J
J
K
K
L
L
G1
G4
GD
GD
GC
GC
GA
GA
GB
GB
H H
I I
G5
G2
001
002
2' - 4" 3' - 6 1/2" 4' - 5 1/2" 14' - 11 1/2" 1' - 0 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 1' - 10"
80' - 8"
17' - 4 1/2"
5' - 5 1/2"
1' - 2"
5' - 5 1/2"
29' - 5 1/2"
1' - 9 1/2"8' - 6 1/2"13' - 2"
23' - 6"
1' - 2"
1' - 0" 1' - 4"10"
12' - 3" 3' - 6" 1' - 7" 6' - 0" 2' - 0 7/8" 4' - 11 1/8" 3' - 0" 37' - 8"
Q
Q
CONCRETE PATIO
CONCRETE
STAIRS
5 1/2"
7 1/2" 7 1/2" 5 1/2"
3
A6.3
NO INSULATION UNDER SLAB
IN WINE ROOM.
NO RADIANT HEAT IN WINE ROOM SLAB
NO FOUNDATION WALL
INSULATION @ WINE ROOM
T.O. CONC. 3' - 0 3/4" @ PERIMETER
G3
1
A6.1
2 3/16"
9 3/16"
3
A5.7
FD
HB
FLOOR DRAIN
FLOOR PLAN GENERAL NOTES:
1. DOWNSPOUTS - RUN IN SOLID PIPE BELOW GRADE TO
DAYLIGHT. (DO NOT CONNECT TO PERIMETER DRAIN
SYSTEM) PROVIDE HEAT TAPE TYPICAL.
2. SLOPE SLAB @ MECHANICAL, WET STORAGE, AND CONC.
MIN. 1/8":12" TO DRAINS ADJUST SLOPES AS REQUIRED
3. MOTORIZED SHADE WITH SHADE POCKETS TO BE
PROVIDE AT LIVING ROOM SOUTH WINDOWS, DOOR, ALL
BEDROOM WINDOWS, AND LARGE BATHROOM WINDOWS.
4. SEE A10.1-A10.3 FOR RCPs WITH SHADE VALANCE DETAIL
CALL OUTS.
5. PROVIDE PERFORATED DRAIN @ PERIMETER AS SHOWN
IN SECTION, DETAIL, SPEC, & SOILS REPORT RUN TO
DAYLIGHT
6. RE: WINDOW SCHEDULE FOR WINDOWS AND DOORS W/
SHADE POCKET ABOVE.
7. SEE INTERIOR ELEVATION SHEETS FOR 1/2" = 1'-0" PLANS
AND ELEVATIONS OF KITCHEN, BATHROOMS AND BUILT-
INS.
PROPOSED SQUARE FOOTAGE ANALYSIS:
3090 Booth Creek Drive, VAIL, CO
Zone District: Two-Family Primary/Secondary Residential ( PS )
Lot is .3.28 acres, equal to 14,288 SF
Allowable GRFA
.46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.46 equals 4,600 SF
.38 SF per 1 SF of site area > 10,000 SF of site area 5,000 x 0.38 equals 1,629 SF
.13 SF per 1 SF of site area > 10,000 SF of site area 6,026 x 0.13 equals 0 SF
_______________________________________________________________________________
Total Allowed Gross Residential Floor Area (GRFA) for entire lot 6,229 SF
Proposed Square Footage Summary (Both Sides of Duplex Combined)
Habitable SF GRFA
Lower Level 2,247.25 SF 902.5 SF *1
Main Level 2,258.5 SF 2,258.5 SF
Upper Level 2,139.5 SF 2,139.5 SF
Garage area over 600 SF 0 SF
Double height space___________________________649 SF___________
Total 6645.25 SF 5949.5 SF
Total Remaining GRFA 279.5 SF
*1 59% of the Lower Level wall is above existing or finished grade whichever was more
restrictive,
therefore 41% of the Lower Level SF is counted as GRFA (LOWER LEVEL HABITABLE 2,247 SF
* .41 = 902.5 SF) NOTE- THESE NUMBER ARE APPROXIMATE UNTIL SUBGRADE AREA CALCS
ARE COMPLETED
Site Coverage
Allowable Site Coverage is 20% of the lot 2,858 SF
Proposed Site Coverage 2,810.5 SF
Proposed Site Coverage for Roofs beyod 4' 34.00 SF
Total Proposed Site Coverage 2,844.5 SF
Total Remaining Site Coverage both sides 13.5 SF
Landscape Area
Lot Size 14,288 SF
60% Landscape Area Requirement 8,572.8 SF
Lot Size 14,288 SF
LESS
Building Footprint / Driveway -5,092.5 SF
Total Landscape Area 9,195.5 SF
Total Hardscape Area Provided (8.3%) 1,666 SF
Total Softscape Area Provided 7,529 SF
Proposed driveway with snowmelt 2,282 SF
Proposed snowmelt @ south patio/ Firepit 253.5 SF
Proposed snowmelt zone to lower level 299 SF
Setbacks
20' from front
15' from sides
15' from rear
Patio can extend to 1/2 the distance of the setback
Decks can encroach set back 5'
Roof or architectural projections can encroach 4'
Height
Flat or mansard roofs not to exceed 30'
Sloping roof not to exceed 33'
Garage
Allow 600 sq. ft. per unit. before area counts towards GRFA
552 SF is provided.
Parking Required per Chapter 10
Primary dwelling unit is more than 5,500 SF GRFA 5 spaces are required. 2 covered 9' x 18' (in
garage) and 3 uncovered 9' x 19' parking spaces are provided.
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
10/12/2015
11:38:58 AM
A3.1
LOWER
LEVEL
FLOOR
PLAN
CWF
HB
REIMERS
RESIDENCE
10/12/2015
3090
BOOTH
CREEK DR. VAIL, CO
TOV FINAL DRB
SUBMITTAL
0' 2' 4' 8' 16'
1/4" = 1'-0"
1
LOWER LEVEL FLOOR PLAN
NORTH
No. Revision Date
Revision
Description
DRB
APPROVED
11/4/2015
12:00:00 AM