HomeMy WebLinkAboutDRB150486_A3-2_1446737280.pdfUP
DN
UP
E04'
E
E14'
E12')
LOT
LOT 7
GGG
8
10
8
4 6 8
6 8
4
4
10
8
4
4
8
8
8
10
10
12
14
12
6 8
E10'
A4.3
A4.4
1
1
A4.1
A4.2
1
1
FRIDGE DOUBLE OVEN
W/ WARMING
DRAWING
PANTRY
MUDROOM
113
GARAGE
114
BREAKFAST
NOOK
110
HEARTH ROOM
111
KITCHEN
108
MASTER
BEDROOM
105
MASTER BATH
103
MASTER CLOSET
102
FRONT ENTRY
101
STAIR
116
DINING ROOM
107
LIVING ROOM
106
POWDER
112
DRESSER
ELECTRICAL
CLOSET
115
LOWER LEVEL PATIO
BELOW
10'-3" X 11'-6"
5'-9" X 6'-0"
10'-0" X 19'-3"
10'-0" X 10'-3"
10'-0" X 9'-0"
15'-0" X 7'-3"
10'-6" X 10'-8"
16'-0" X 19'-0"
12'-0" X 19'-0"
14'-0" X 14'-0"
9'-10" X 11'-0"
SHOWER
11'-7" X 9'-1"
CLOSET
101B
OUTDOOR LIVING
ROOM
109
22'-0" X 18'-0"
B UI LDI NG SETB ACK
BU I L DIN G SET BAC K
BUI
LDI
NG SETBACK
22'-7" X 22'-11"(23'-1")
LINE OF ENTRY ROOF ABOVE
LINE OF DECK ABOVE
BEST VIEW OF THE GORE RANGE
14.0°
WATERFALL
CLIFFS
GORE RANGE
GORE RANGE
BUILDING FOOT PRINT OF EXISTING HOUSE
BUILDING
FOOTPRINT OF EXISTING HOUSE
13' - 2"TRASH
RECYCLE
RECYCLE
LINE OF DECK ABOVE
BENCH W/
CUBBIES ABOVE
T.O. FINISH 11' - 5 3/4"
T.O. FINISH 10' - 10 5/8"
7"
3/4"
1" 6"
6"
6"
3/4"
3/4"
16' - 4 5/8"
DW
RECYCLE
TRASH
23' - 6"
22' - 10"
10' - 4"13' - 2"
STEAM SHOWER
T.O. GYPCRETE 11' - 5"
T.O. PLYWOOD 11' - 2 3/4"
A4.5
1
A4.5
2
1
A5.5
1
A5.7
1
A5.6
2' - 7 3/4"
2
A5.5
4' - 0" 3' - 0"
A4.5
3
1
A5.1
15' - 9"
2%SLOPE
4
A5.5
2
A5.7
2
A6.1
3
A6.1
5
A6.1
6
A6.1
3
A6.2
2
A6.2
1
A6.3
1
A6.2
2
A6.3
4
A6.1
5
A6.1
5
A6.7
1
A6.1
2
A6.3
2
A6.3
A6.6
5
A6.5
2
7
A6.1
13
A6.6
4%
1
A5.2
1
A5.3
1
A5.4 2
A5.4
3
A5.5
1
A5.8
1
A5.9
?
2 RISERS @ 7"
1 TREAD @ 11"
9' - 8 3/4"
Q
Q
Q
Q
Q
Q
Q
Q
Q
Q
W.C.
104
101A
101B
102A
103A
105A
104A
112A
113C
108B
108A
113A 113B
115A
114A
103B
116A
TILE WOOD CARPET
WOOD
STONE
WOOD
TILE
WOOD
EPOXYTILE
5
A6.7
SOILS TEST BORING #1
FREE WATER @ 8299.8'
ON 6/10/15
+7.8
GAS METER PAINTED
TO MATCH STONE VENEER
SOILS TEST BORING #2
FREE WATER @ 8300.9'
ON 6/10/15
+7.9
FD
FD
1/8" : 1'-0"
1/8" : 1'-0"
J-BOX
DS
DS
DS
DS
DS
DS
DS
DS
1
1
2
2
3
3
4
4
5
5
4 1/4"
1 5/16"
6
6 7
7 8
8 9
9
10
10 11
11 12
12
A
A
B
B
C
C
D
D
E
E
F
F
G
G
J
J
K
K
L
L
G1
G4
GD
GD
GC
GC
GA
GA
GB
GB
H H
I I
G5
G2
101
102
105
107
108 109
110
111 112
114
115
116
117
118
119
2' - 4" 3' - 6 1/2" 4' - 5 1/2" 14' - 11 1/2" 1' - 0 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 1' - 10"
80' - 8"
1
7' - 4 1/2"
5' - 5 1/2"
1' - 2"
5' - 5 1/2"
29' - 5 1/2"
1' - 9 1/2"8' - 6 1/2"13' - 2"
23' - 6"
1' - 2"
1' - 0" 1' - 4"10"
12' - 3" 3' - 6" 1' - 7" 6' - 0" 2' - 0 7/8" 4' - 11 1/8" 3' - 0" 37' - 8"
Q
Q
Q
Q
Q
Q MICROWAVE
TV ABOVE FIREPLACE
PROVIDE NICHE IN STONE VENEER
FOR TV BRACKET W/ POWER AND
CONNECTION
48" COOK TOP
G3
DS
DS
CENTOR SCREEN
BOILER FLUES TO BE VENTED
THRU CHIMNEY CAP IN 2X8 WALL
LINE OF BRIDGEWAY ABOVE
5
A6.2
9 1/2"
3
A5.7
106
9 1/2"
1' - 7 1/2" 1' - 7 1/2" 6' - 9 1/2"
7' - 0 3/8" AC UNIT
@MASTER
5' - 4 13/16"
7' - 6 1/2"
ROUGH IN FOR MAKE UP
AIR A/C AND WINE
ROOM COOLER
HB
HB
HB
HB
HO T AN D COLD W ATER HB
SURFACE
PARKING
(9' X 19')
SURFACE
PARKING
(9' X 19')
SU RFACEP ARKIN G
(9' X 19')FLOOR PLAN GENERAL NOTES:
1. DOWNSPOUTS - RUN IN SOLID PIPE BELOW GRADE TO
DAYLIGHT. (DO NOT CONNECT TO PERIMETER DRAIN
SYSTEM) PROVIDE HEAT TAPE TYPICAL.
2. SLOPE SLAB @ MECHANICAL, WET STORAGE, AND CONC.
MIN. 1/8":12" TO DRAINS ADJUST SLOPES AS REQUIRED
3. MOTORIZED SHADE WITH SHADE POCKETS TO BE
PROVIDE AT LIVING ROOM SOUTH WINDOWS, DOOR, ALL
BEDROOM WINDOWS, AND LARGE BATHROOM WINDOWS.
4. SEE A10.1-A10.3 FOR RCPs WITH SHADE VALANCE DETAIL
CALL OUTS.
5. PROVIDE PERFORATED DRAIN @ PERIMETER AS SHOWN
IN SECTION, DETAIL, SPEC, & SOILS REPORT RUN TO
DAYLIGHT
6. RE: WINDOW SCHEDULE FOR WINDOWS AND DOORS W/
SHADE POCKET ABOVE.
7. SEE INTERIOR ELEVATION SHEETS FOR 1/2" = 1'-0" PLANS
AND ELEVATIONS OF KITCHEN, BATHROOMS AND BUILT-
INS.
PROPOSED SQUARE FOOTAGE ANALYSIS:
3090 Booth Creek Drive, VAIL, CO
Zone District: Two-Family Primary/Secondary Residential ( PS )
Lot is .3.28 acres, equal to 14,288 SF
Allowable GRFA
.46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.46 equals 4,600 SF
.38 SF per 1 SF of site area > 10,000 SF of site area 5,000 x 0.38 equals 1,629 SF
.13 SF per 1 SF of site area > 10,000 SF of site area 6,026 x 0.13 equals 0 SF
_______________________________________________________________________________
Total Allowed Gross Residential Floor Area (GRFA) for entire lot 6,229 SF
Proposed Square Footage Summary (Both Sides of Duplex Combined)
Habitable SF GRFA
Lower Level 2,247.25 SF 902.5 SF *1
Main Level 2,258.5 SF 2,258.5 SF
Upper Level 2,139.5 SF 2,139.5 SF
Garage area over 600 SF 0 SF
Double height space___________________________649 SF___________
Total 6645.25 SF 5949.5 SF
Total Remaining GRFA 279.5 SF
*1 59% of the Lower Level wall is above existing or finished grade whichever was more
restrictive,
therefore 41% of the Lower Level SF is counted as GRFA (LOWER LEVEL HABITABLE 2,247 SF
* .41 = 902.5 SF) NOTE- THESE NUMBER ARE APPROXIMATE UNTIL SUBGRADE AREA CALCS
ARE COMPLETED
Site Coverage
Allowable Site Coverage is 20% of the lot 2,858 SF
Proposed Site Coverage 2,810.5 SF
Proposed Site Coverage for Roofs beyod 4' 34.00 SF
Total Proposed Site Coverage 2,844.5 SF
Total Remaining Site Coverage both sides 13.5 SF
Landscape Area
Lot Size 14,288 SF
60% Landscape Area Requirement 8,572.8 SF
Lot Size 14,288 SF
LESS
Building Footprint / Driveway -5,092.5 SF
Total Landscape Area 9,195.5 SF
Total Hardscape Area Provided (8.3%) 1,666 SF
Total Softscape Area Provided 7,529 SF
Proposed driveway with snowmelt 2,282 SF
Proposed snowmelt @ south patio/ Firepit 253.5 SF
Proposed snowmelt zone to lower level 299 SF
Setbacks
20' from front
15' from sides
15' from rear
Patio can extend to 1/2 the distance of the setback
Decks can encroach set back 5'
Roof or architectural projections can encroach 4'
Height
Flat or mansard roofs not to exceed 30'
Sloping roof not to exceed 33'
Garage
Allow 600 sq. ft. per unit. before area counts towards GRFA
552 SF is provided.
Parking Required per Chapter 10
Primary dwelling unit is more than 5,500 SF GRFA 5 spaces are required. 2 covered 9' x 18' (in
garage) and 3 uncovered 9' x 19' parking spaces are provided.
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
10/12/2015
11:39:29 AM
A3.2
MAIN LEVEL
FLOOR
PLAN
CWF
HB
REIMERS
RESIDENCE
10/12/2015
3090
BOOTH
CREEK DR. VAIL, CO
TOV FINAL DRB
SUBMITTAL
0' 2' 4' 8' 16'
1/4" = 1'-0"
1
MAIN LEVEL FLOOR PLAN
NORTH
No. Revision Date
Revision
Description
DRB
APPROVED
11/4/2015
12:00:00 AM