Loading...
HomeMy WebLinkAboutDRB150486_A3-2_1446737280.pdfUP DN UP E04' E E14' E12') LOT LOT 7 GGG 8 10 8 4 6 8 6 8 4 4 10 8 4 4 8 8 8 10 10 12 14 12 6 8 E10' A4.3 A4.4 1 1 A4.1 A4.2 1 1 FRIDGE DOUBLE OVEN W/ WARMING DRAWING PANTRY MUDROOM 113 GARAGE 114 BREAKFAST NOOK 110 HEARTH ROOM 111 KITCHEN 108 MASTER BEDROOM 105 MASTER BATH 103 MASTER CLOSET 102 FRONT ENTRY 101 STAIR 116 DINING ROOM 107 LIVING ROOM 106 POWDER 112 DRESSER ELECTRICAL CLOSET 115 LOWER LEVEL PATIO BELOW 10'-3" X 11'-6" 5'-9" X 6'-0" 10'-0" X 19'-3" 10'-0" X 10'-3" 10'-0" X 9'-0" 15'-0" X 7'-3" 10'-6" X 10'-8" 16'-0" X 19'-0" 12'-0" X 19'-0" 14'-0" X 14'-0" 9'-10" X 11'-0" SHOWER 11'-7" X 9'-1" CLOSET 101B OUTDOOR LIVING ROOM 109 22'-0" X 18'-0" B UI LDI NG SETB ACK BU I L DIN G SET BAC K BUI LDI NG SETBACK 22'-7" X 22'-11"(23'-1") LINE OF ENTRY ROOF ABOVE LINE OF DECK ABOVE BEST VIEW OF THE GORE RANGE 14.0° WATERFALL CLIFFS GORE RANGE GORE RANGE BUILDING FOOT PRINT OF EXISTING HOUSE BUILDING FOOTPRINT OF EXISTING HOUSE 13' - 2"TRASH RECYCLE RECYCLE LINE OF DECK ABOVE BENCH W/ CUBBIES ABOVE T.O. FINISH 11' - 5 3/4" T.O. FINISH 10' - 10 5/8" 7" 3/4" 1" 6" 6" 6" 3/4" 3/4" 16' - 4 5/8" DW RECYCLE TRASH 23' - 6" 22' - 10" 10' - 4"13' - 2" STEAM SHOWER T.O. GYPCRETE 11' - 5" T.O. PLYWOOD 11' - 2 3/4" A4.5 1 A4.5 2 1 A5.5 1 A5.7 1 A5.6 2' - 7 3/4" 2 A5.5 4' - 0" 3' - 0" A4.5 3 1 A5.1 15' - 9" 2%SLOPE 4 A5.5 2 A5.7 2 A6.1 3 A6.1 5 A6.1 6 A6.1 3 A6.2 2 A6.2 1 A6.3 1 A6.2 2 A6.3 4 A6.1 5 A6.1 5 A6.7 1 A6.1 2 A6.3 2 A6.3 A6.6 5 A6.5 2 7 A6.1 13 A6.6 4% 1 A5.2 1 A5.3 1 A5.4 2 A5.4 3 A5.5 1 A5.8 1 A5.9 ? 2 RISERS @ 7" 1 TREAD @ 11" 9' - 8 3/4" Q Q Q Q Q Q Q Q Q Q W.C. 104 101A 101B 102A 103A 105A 104A 112A 113C 108B 108A 113A 113B 115A 114A 103B 116A TILE WOOD CARPET WOOD STONE WOOD TILE WOOD EPOXYTILE 5 A6.7 SOILS TEST BORING #1 FREE WATER @ 8299.8' ON 6/10/15 +7.8 GAS METER PAINTED TO MATCH STONE VENEER SOILS TEST BORING #2 FREE WATER @ 8300.9' ON 6/10/15 +7.9 FD FD 1/8" : 1'-0" 1/8" : 1'-0" J-BOX DS DS DS DS DS DS DS DS 1 1 2 2 3 3 4 4 5 5 4 1/4" 1 5/16" 6 6 7 7 8 8 9 9 10 10 11 11 12 12 A A B B C C D D E E F F G G J J K K L L G1 G4 GD GD GC GC GA GA GB GB H H I I G5 G2 101 102 105 107 108 109 110 111 112 114 115 116 117 118 119 2' - 4" 3' - 6 1/2" 4' - 5 1/2" 14' - 11 1/2" 1' - 0 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 1' - 10" 80' - 8" 1 7' - 4 1/2" 5' - 5 1/2" 1' - 2" 5' - 5 1/2" 29' - 5 1/2" 1' - 9 1/2"8' - 6 1/2"13' - 2" 23' - 6" 1' - 2" 1' - 0" 1' - 4"10" 12' - 3" 3' - 6" 1' - 7" 6' - 0" 2' - 0 7/8" 4' - 11 1/8" 3' - 0" 37' - 8" Q Q Q Q Q Q MICROWAVE TV ABOVE FIREPLACE PROVIDE NICHE IN STONE VENEER FOR TV BRACKET W/ POWER AND CONNECTION 48" COOK TOP G3 DS DS CENTOR SCREEN BOILER FLUES TO BE VENTED THRU CHIMNEY CAP IN 2X8 WALL LINE OF BRIDGEWAY ABOVE 5 A6.2 9 1/2" 3 A5.7 106 9 1/2" 1' - 7 1/2" 1' - 7 1/2" 6' - 9 1/2" 7' - 0 3/8" AC UNIT @MASTER 5' - 4 13/16" 7' - 6 1/2" ROUGH IN FOR MAKE UP AIR A/C AND WINE ROOM COOLER HB HB HB HB HO T AN D COLD W ATER HB SURFACE PARKING (9' X 19') SURFACE PARKING (9' X 19') SU RFACEP ARKIN G (9' X 19')FLOOR PLAN GENERAL NOTES: 1. DOWNSPOUTS - RUN IN SOLID PIPE BELOW GRADE TO DAYLIGHT. (DO NOT CONNECT TO PERIMETER DRAIN SYSTEM) PROVIDE HEAT TAPE TYPICAL. 2. SLOPE SLAB @ MECHANICAL, WET STORAGE, AND CONC. MIN. 1/8":12" TO DRAINS ADJUST SLOPES AS REQUIRED 3. MOTORIZED SHADE WITH SHADE POCKETS TO BE PROVIDE AT LIVING ROOM SOUTH WINDOWS, DOOR, ALL BEDROOM WINDOWS, AND LARGE BATHROOM WINDOWS. 4. SEE A10.1-A10.3 FOR RCPs WITH SHADE VALANCE DETAIL CALL OUTS. 5. PROVIDE PERFORATED DRAIN @ PERIMETER AS SHOWN IN SECTION, DETAIL, SPEC, & SOILS REPORT RUN TO DAYLIGHT 6. RE: WINDOW SCHEDULE FOR WINDOWS AND DOORS W/ SHADE POCKET ABOVE. 7. SEE INTERIOR ELEVATION SHEETS FOR 1/2" = 1'-0" PLANS AND ELEVATIONS OF KITCHEN, BATHROOMS AND BUILT- INS. PROPOSED SQUARE FOOTAGE ANALYSIS: 3090 Booth Creek Drive, VAIL, CO Zone District: Two-Family Primary/Secondary Residential ( PS ) Lot is .3.28 acres, equal to 14,288 SF Allowable GRFA .46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.46 equals 4,600 SF .38 SF per 1 SF of site area > 10,000 SF of site area 5,000 x 0.38 equals 1,629 SF .13 SF per 1 SF of site area > 10,000 SF of site area 6,026 x 0.13 equals 0 SF _______________________________________________________________________________ Total Allowed Gross Residential Floor Area (GRFA) for entire lot 6,229 SF Proposed Square Footage Summary (Both Sides of Duplex Combined) Habitable SF GRFA Lower Level 2,247.25 SF 902.5 SF *1 Main Level 2,258.5 SF 2,258.5 SF Upper Level 2,139.5 SF 2,139.5 SF Garage area over 600 SF 0 SF Double height space___________________________649 SF___________ Total 6645.25 SF 5949.5 SF Total Remaining GRFA 279.5 SF *1 59% of the Lower Level wall is above existing or finished grade whichever was more restrictive, therefore 41% of the Lower Level SF is counted as GRFA (LOWER LEVEL HABITABLE 2,247 SF * .41 = 902.5 SF) NOTE- THESE NUMBER ARE APPROXIMATE UNTIL SUBGRADE AREA CALCS ARE COMPLETED Site Coverage Allowable Site Coverage is 20% of the lot 2,858 SF Proposed Site Coverage 2,810.5 SF Proposed Site Coverage for Roofs beyod 4' 34.00 SF Total Proposed Site Coverage 2,844.5 SF Total Remaining Site Coverage both sides 13.5 SF Landscape Area Lot Size 14,288 SF 60% Landscape Area Requirement 8,572.8 SF Lot Size 14,288 SF LESS Building Footprint / Driveway -5,092.5 SF Total Landscape Area 9,195.5 SF Total Hardscape Area Provided (8.3%) 1,666 SF Total Softscape Area Provided 7,529 SF Proposed driveway with snowmelt 2,282 SF Proposed snowmelt @ south patio/ Firepit 253.5 SF Proposed snowmelt zone to lower level 299 SF Setbacks 20' from front 15' from sides 15' from rear Patio can extend to 1/2 the distance of the setback Decks can encroach set back 5' Roof or architectural projections can encroach 4' Height Flat or mansard roofs not to exceed 30' Sloping roof not to exceed 33' Garage Allow 600 sq. ft. per unit. before area counts towards GRFA 552 SF is provided. Parking Required per Chapter 10 Primary dwelling unit is more than 5,500 SF GRFA 5 spaces are required. 2 covered 9' x 18' (in garage) and 3 uncovered 9' x 19' parking spaces are provided. Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 10/12/2015 11:39:29 AM A3.2 MAIN LEVEL FLOOR PLAN CWF HB REIMERS RESIDENCE 10/12/2015 3090 BOOTH CREEK DR. VAIL, CO TOV FINAL DRB SUBMITTAL 0' 2' 4' 8' 16' 1/4" = 1'-0" 1 MAIN LEVEL FLOOR PLAN NORTH No. Revision Date Revision Description DRB APPROVED 11/4/2015 12:00:00 AM