Loading...
HomeMy WebLinkAboutDRB150486_A6-2_1446737340.pdfT.O. CONCRETE WALL 0" - 0' SLOPE TO DRAIN GARAGE EXTERIOR CONC. SLAB W/ IN-FLOOR RADIANT HEAT SLOPED PER PLANS 10 MIL. VAPOR BARRIER TURNS UP WALL MECH. FASTEN AND SEAL TO WALL. SEAL ALL JOINTS AND PENETRATIONS TYP. RE: SPEC MIN R-10 RIGID FOAM INSULATION PANEL @ GARAGE LOCATIONS LESS THAN 1' - 0" BELOW GRADE RE: SPEC OVER WATERPROOF MEMBRANE. ALTERNATE COMBINATION INSULATION / DRAINAGE MEDIUM MAY BE PROPOSED PER SPEC. GRAVEL BED PER SOILS ENGINEER, STRUCT AND CIVIL DRAWINGS SMART MEMBRANE VAPOR BARRIER RE: SPEC W.P. EPOXY LIQUID GRANITE FLOORING OVER CONC. SLAB AND TURNS UP WALL MIN. 6" RE: SPEC 5/8" GYP SHEATHING OR MOISTURE RESISTANT DRYWALL OUTSWING DOOR RE: DOOR SCHEDULE. POUR SLAB AFTER ELECTRIC CONDUIT IS INSTALLED P.T. PLYWOOD OVER FOUNDATION WATERPROOFING OVER CONCRETE FOUNDATION & WITHIN 6" OF GRADE RE:SPEC ELECTRIC CLOSET 1/2" EXPANSION JOINT NOTE: SEE 1 / A6.1 FOR TYPICAL FOUNDATION NOTES 5" RE: STRUCT. CONC. FOUNDATION BEYOND 1/2" P.T. PLYWOOD RAMSET TO CONCRETE NON PAPER-FACED GYP. SHEATHING OVER CONCRETE RE: STRUCT. RE: STRUCT. GRID LINE GRID LINE T.O. PLYWOOD RE: PLANS INTERIOR INTERIOR GARAGE GRID LINE 8" 2 1/4" RE: STRUCT. SEE 1 / A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY T.O. CONC. RE: PLANS T.O. CONC. RE: PLANS SEE 2/A6.1 FOR TYP. GARAGE SLAB AND INT. WALL ASSEMBLY SLOPE 5/8" TYPE X GWB @ GARAGE LEDGER RE: STRUCT. RE: STRUCT. 3" 5" SLOPE 1" T.O. PLYWOOD RE: PLANS INTERIOR INTERIOR EXTERIOR GRID LINE STRUCTURAL SLAB RE: STRUCT. 1' - 1" 2 1/4" RE: STRUCT. SLOPE PER PLANS SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY T.O. CONC. RE: PLANS T.O. CONC. RE: PLANS LIFT AND SLIDE DOOR RE: WINDOW SCHEDULE W.P. MEMBRANE CONT. UNDER DOOR SILL TURNS UP 1" VERTICAL OVER METAL FLASHING @ BACK EDGE OF DOOR SILL CONTINUES 3' OUT OVER CONC. SLAB @ PATIO METAL FLASHING UP CONC. WALL, UNDER DOOR SILL AND TURNS UP 1" VERTICAL @ BACK EDGE OF DOOR SILL SEE 2/A6.1 FOR TYP. PATIO ASSEMBLY RE: STRUCT. LEDGER RE: STRUCT. 7 1/2" 5 1/2" CENTOR SCREEN RE: WINDOW SCHEDULE INSULATION PANEL RE: SPEC AND COVER SHEET A6.5 3 SLOPE 7" 6" 1" AIR SPACE TYP. 2X4 WALL TYP. 1/2" 1" EXTERIOR 6" THICKEND CONC. SLAB EDGE SLOPED PER SITEPLAN 2" RIGID R-10 INSULATION UNDER SLAB RE: SPEC APPROX. 1' - 6" CONC. APRON VERIFY PAVER THICKNESS W/ FINAL SPECIFICATIONS SLOPE 2" SAND BED WITH RADIANT HEAT TUBING (2) #5 REBAR GROUT UNDER 11" SOLDIER COURSE CONC. PAVER BORDER CONC. PAVER BORDER 6" T.O. PLYWOOD RE: PLANS INTERIOR INTERIOR EXTERIOR GRID LINE RE: STRUCT T.O. CONC. 8300' - 11" T.O. CONC. RE: PLANS SLOPE FINISHED FLOOR RE: PLANS AND SPEC OVER GYPCRETE W/ IN-FLOOR RADIANT HEAT RE: PLANS AND SPEC. TOTAL ASSEMBLY FOR FINISH & GYPCRETE IS 2 1/4" BLOWN IN INSULATION FILL JOIST CAVITY RE: SPEC. P.T. 2X PLATE 5" CONC. SLAB W/ IN-FLOOR RADIANT HEAT RE: STRUCTURAL DRAWINGS 2" RIGID INSULATION UNDER CONC. SLAB RE: SPEC AND COVER SHEET 13" CONC. WALL RE: STRUCTURAL LEDGER RE: STRUCT. PRESSURE TREATED PLATE SWELL TYPE WATER STOP RE: SPEC 5/8" EXT. GWB SHEATHING NON PAPER FACED MOISTURE RESISTANT @ BASEMENT WALLS TYP. W.P. MEMBRANE CONT. FROM B.O. FOOTING TO T.O. CONC. WALL 6" DIAMETER PERFORATED PERIMETER DRAIN PIPE IN GRAVEL BED TO DAYLIGHT PER SOILS REPORT, SPEC, AND AND SITE PLAN CONC. MAT SLAB RE: STRUCT. SLOPED TOPPING SLAB TO INTERIOR SUMP PUMP GRAVEL PREPRUFE 300R SYSTEM AMERICAN HYDROTECH 6125FR, 215 MIL , FABRIC REINFORCED , HOT FLUID APPLIED WATERPROOFING SYSTEM 12" NEOPRENE FLASHING CCW 711-90 FLASHING 12" STRIP 6" MIN. LAP ON TOP AND FACE OF FOOTING OVER BITUTHENE BITUTHENE 4000 12" STRIP BITUTHENE LIQUID MEMBRANE TERMINATION MIRA DRAIN DRAINAGE MEDIUM CONT. AGAINST WALLS DOWN TO SLOPED TOPPING SLAB RE: SPEC. HIGH DENSITY, 2.0 PCF CLOSED CELL POLYURETHANE FOAM INSULATION; INSTALL IN CONT. MANNER MIRA DRAIN DRAINAGE MEDIUM OVER 2" RIGID INSULATION MIN. R-10 3"-4" THICK CONC. RAT SLAB 2X4 P.T. STUDS TYP. @ LOWER LEVEL T.O. CONC. @ RE: PLANS WATERPROOF MEMBRANE RE: SPEC. FOR PREPRUFE 300R SYSTEM 10 MIL VAPOR BARRIER EXTEND UP PAST T.O. CONC. SLAB 6" MIN; TAPE TO DRAINAGE MATT HOLD DRAINAGE MEDIUM DOWN 3" FROM LEDGER. SEAL TOP WITH SPRAY FOAM INSULATION INJECTO TUBE GROUTABLE HOSE WATERSTOP SYSTEM STONE VENEER OVER 3D DRAINAGE MATERIAL OVER AIR AND WATER INFILTRATION BARRIER CONT. @ WALL. LAP OVER BITUTHANE FLASHING, CONC. LEDGE, & MIRADRAIN DRAINAGE MEDIUM @ FOUNDATION. DRAINAGE MEDIUM CONT. UNDER B.O. STONE OR PROVIDE WEEP SO THAT DRAINAGE MEDIUM CAN DRAIN AT BO WALL. 1' - 1" RE: STRUCT BORING #1 FREE WATER ON 6/10/15 8299.8' BORING #2 FREE WATER ON 6/10/15 8301.9' 11 13/16" 1' - 0 1/2" SLOPE 1/2" 7 1/2" 5 1/2" 6" MIN 6" MAX Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1 1/2" = 1'-0" 10/12/2015 11:44:22 AM A6.2 FOUNDATION DETAILS CWF HB REIMERS RESIDENCE 10/12/2015 3090 BOOTH CREEK DR. VAIL, CO TOV FINAL DRB SUBMITTAL No. Revision Date Revision Description 1 1/2" = 1'-0" 2 FOUNDATION DETAIL @ ELECTRICAL CLOSET 1 1/2" = 1'-0" 1 FOUNDATION DETAIL @ GARAGE AND LOWER LEVEL 1 1/2" = 1'-0" 3 FOUNDATION DETAIL @ LIFT AND SLIDE DOOR THRESHOLD 1 1/2" = 1'-0" 4 SAND SET PAVER DRIVEWAY BORDER DETAIL 1 1/2" = 1'-0" 5 FOUNDATION DETAIL W/ JOIST BEARING ON CONC. WALL DRB APPROVED 11/4/2015 12:00:00 AM