HomeMy WebLinkAboutDRB150486_A6-2_1446737340.pdfT.O. CONCRETE WALL
0" - 0'
SLOPE TO DRAIN
GARAGE
EXTERIOR
CONC. SLAB W/ IN-FLOOR
RADIANT HEAT SLOPED
PER PLANS
10 MIL. VAPOR BARRIER TURNS UP
WALL MECH. FASTEN AND SEAL TO
WALL. SEAL ALL JOINTS AND
PENETRATIONS TYP. RE: SPEC
MIN R-10 RIGID FOAM INSULATION PANEL @
GARAGE LOCATIONS LESS THAN 1' - 0" BELOW
GRADE RE: SPEC OVER WATERPROOF
MEMBRANE. ALTERNATE COMBINATION
INSULATION / DRAINAGE MEDIUM MAY BE
PROPOSED PER SPEC.
GRAVEL BED PER SOILS ENGINEER, STRUCT
AND CIVIL DRAWINGS
SMART MEMBRANE VAPOR BARRIER RE: SPEC
W.P. EPOXY LIQUID GRANITE FLOORING
OVER CONC. SLAB AND TURNS UP WALL
MIN. 6"
RE: SPEC
5/8" GYP SHEATHING OR MOISTURE
RESISTANT DRYWALL
OUTSWING DOOR RE: DOOR SCHEDULE.
POUR SLAB AFTER ELECTRIC
CONDUIT IS INSTALLED
P.T. PLYWOOD OVER FOUNDATION
WATERPROOFING OVER CONCRETE
FOUNDATION & WITHIN 6" OF GRADE
RE:SPEC
ELECTRIC CLOSET
1/2" EXPANSION JOINT
NOTE: SEE 1 / A6.1 FOR TYPICAL
FOUNDATION NOTES
5"
RE: STRUCT.
CONC. FOUNDATION BEYOND
1/2" P.T. PLYWOOD RAMSET TO
CONCRETE
NON PAPER-FACED GYP. SHEATHING
OVER CONCRETE
RE: STRUCT.
RE: STRUCT.
GRID
LINE
GRID
LINE
T.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR
GARAGE
GRID
LINE
8"
2 1/4"
RE: STRUCT.
SEE 1 / A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS
SEE 2/A6.1 FOR TYP.
GARAGE SLAB AND INT.
WALL ASSEMBLY
SLOPE
5/8" TYPE X GWB @ GARAGE
LEDGER RE: STRUCT.
RE: STRUCT.
3" 5"
SLOPE
1"
T.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR
EXTERIOR
GRID
LINE
STRUCTURAL SLAB
RE: STRUCT.
1' - 1" 2 1/4"
RE: STRUCT.
SLOPE PER PLANS
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS
LIFT AND SLIDE DOOR RE: WINDOW SCHEDULE
W.P. MEMBRANE CONT. UNDER DOOR SILL
TURNS UP 1" VERTICAL OVER METAL
FLASHING @ BACK EDGE OF DOOR SILL
CONTINUES 3' OUT OVER CONC. SLAB @
PATIO
METAL FLASHING UP CONC. WALL, UNDER
DOOR SILL AND TURNS UP 1" VERTICAL @
BACK EDGE OF DOOR SILL
SEE 2/A6.1 FOR TYP. PATIO
ASSEMBLY
RE: STRUCT.
LEDGER RE: STRUCT.
7 1/2" 5 1/2"
CENTOR SCREEN RE: WINDOW SCHEDULE
INSULATION PANEL
RE: SPEC AND COVER SHEET
A6.5
3
SLOPE
7" 6"
1" AIR SPACE TYP.
2X4 WALL TYP.
1/2"
1"
EXTERIOR
6" THICKEND CONC.
SLAB EDGE SLOPED PER
SITEPLAN
2" RIGID R-10 INSULATION UNDER SLAB
RE: SPEC
APPROX. 1' - 6" CONC. APRON
VERIFY PAVER
THICKNESS W/ FINAL
SPECIFICATIONS SLOPE
2" SAND BED WITH RADIANT HEAT TUBING
(2) #5 REBAR
GROUT UNDER 11" SOLDIER
COURSE CONC. PAVER
BORDER
CONC. PAVER BORDER
6"
T.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR
EXTERIOR
GRID
LINE
RE: STRUCT
T.O. CONC.
8300' - 11"
T.O. CONC.
RE: PLANS
SLOPE
FINISHED FLOOR RE: PLANS AND SPEC OVER
GYPCRETE W/ IN-FLOOR RADIANT HEAT
RE: PLANS AND SPEC. TOTAL ASSEMBLY FOR
FINISH & GYPCRETE IS 2 1/4"
BLOWN IN INSULATION FILL JOIST CAVITY
RE: SPEC.
P.T. 2X PLATE
5" CONC. SLAB W/ IN-FLOOR
RADIANT HEAT
RE: STRUCTURAL DRAWINGS
2" RIGID INSULATION UNDER
CONC. SLAB
RE: SPEC AND COVER SHEET
13" CONC. WALL
RE: STRUCTURAL
LEDGER RE: STRUCT.
PRESSURE TREATED PLATE
SWELL TYPE WATER STOP
RE: SPEC
5/8" EXT. GWB SHEATHING NON PAPER
FACED MOISTURE RESISTANT @
BASEMENT WALLS TYP.
W.P. MEMBRANE CONT. FROM B.O.
FOOTING TO T.O. CONC. WALL
6" DIAMETER PERFORATED
PERIMETER DRAIN PIPE IN
GRAVEL BED TO DAYLIGHT PER
SOILS REPORT, SPEC, AND AND
SITE PLAN
CONC. MAT SLAB RE: STRUCT.
SLOPED TOPPING SLAB TO INTERIOR
SUMP PUMP
GRAVEL
PREPRUFE 300R SYSTEM
AMERICAN HYDROTECH 6125FR, 215 MIL ,
FABRIC REINFORCED , HOT FLUID APPLIED
WATERPROOFING SYSTEM
12" NEOPRENE FLASHING
CCW 711-90 FLASHING 12" STRIP
6" MIN. LAP ON TOP AND FACE
OF FOOTING OVER BITUTHENE
BITUTHENE 4000 12" STRIP
BITUTHENE LIQUID
MEMBRANE TERMINATION
MIRA DRAIN DRAINAGE MEDIUM CONT.
AGAINST WALLS DOWN TO SLOPED TOPPING
SLAB RE: SPEC.
HIGH DENSITY, 2.0 PCF CLOSED CELL
POLYURETHANE FOAM INSULATION; INSTALL IN
CONT. MANNER
MIRA DRAIN DRAINAGE MEDIUM OVER 2" RIGID
INSULATION MIN. R-10
3"-4" THICK CONC. RAT SLAB
2X4 P.T. STUDS TYP. @ LOWER LEVEL
T.O. CONC. @
RE: PLANS
WATERPROOF MEMBRANE RE: SPEC. FOR
PREPRUFE 300R SYSTEM
10 MIL VAPOR BARRIER EXTEND UP PAST
T.O. CONC. SLAB 6" MIN; TAPE TO DRAINAGE
MATT
HOLD DRAINAGE MEDIUM DOWN 3" FROM
LEDGER. SEAL TOP WITH SPRAY FOAM
INSULATION
INJECTO TUBE GROUTABLE HOSE
WATERSTOP SYSTEM
STONE VENEER OVER 3D DRAINAGE MATERIAL OVER AIR
AND WATER INFILTRATION BARRIER CONT. @ WALL. LAP
OVER BITUTHANE FLASHING, CONC. LEDGE, & MIRADRAIN
DRAINAGE MEDIUM @ FOUNDATION. DRAINAGE MEDIUM
CONT. UNDER B.O. STONE OR PROVIDE WEEP SO THAT
DRAINAGE MEDIUM CAN DRAIN AT BO WALL.
1' - 1" RE: STRUCT
BORING #1 FREE WATER ON 6/10/15
8299.8'
BORING #2 FREE WATER ON 6/10/15
8301.9' 11 13/16"
1' - 0 1/2" SLOPE
1/2"
7 1/2" 5 1/2"
6" MIN
6" MAX Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1 1/2" = 1'-0"
10/12/2015
11:44:22 AM
A6.2
FOUNDATION
DETAILS
CWF
HB
REIMERS
RESIDENCE
10/12/2015
3090
BOOTH
CREEK DR. VAIL, CO
TOV FINAL DRB
SUBMITTAL
No. Revision Date
Revision
Description
1 1/2" = 1'-0"
2
FOUNDATION DETAIL @ ELECTRICAL
CLOSET
1 1/2" = 1'-0"
1
FOUNDATION DETAIL @ GARAGE AND
LOWER LEVEL
1 1/2" = 1'-0"
3
FOUNDATION DETAIL @ LIFT AND SLIDE
DOOR THRESHOLD
1 1/2" = 1'-0"
4
SAND SET PAVER DRIVEWAY BORDER
DETAIL
1 1/2" = 1'-0"
5
FOUNDATION DETAIL W/ JOIST BEARING
ON CONC. WALL
DRB
APPROVED
11/4/2015
12:00:00 AM